Peng Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peng Xiao has a total of 145 co-authors. Here are the top co-authors by number of shared publications:
- Qingguo Xie
Huazhong University of Science and Technology
15 shared publications Qingguo Xie
Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan, Peoples R China
7 shared publications- Ang Li
Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China
5 shared publications - Bingxuan Li
Institute of Artificial Intelligence, Hefei Comprehensive National Science Center, Hefei, China
5 shared publications - Xun Chen
University of Science and Technology of China
5 shared publications Yu Liu
Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, PR China
5 shared publications
Latest Publications
- 20 August 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (16) , 165013
Estimation of dose and linear energy transfer for multi-spot single-energy proton probing beams using in-beam PET and neural network
Objective . In-beam positron emission tomography (PET) enables online measurements of proton-induced positron-emitting activity and has been widely investigated for in vivo range verification in proton therapy. This study proposes a neural network-based method for the simultaneous estimation of three-dimensional dose and linear energy transfer (LET) distributions from in-beam PET data following single-energy probing-beam irradiation. The performance and feasibility of the proposed method were investigated through Monte Carlo simulations and experimental measurements. Approach . Single-energy proton beams were delivered as probes to head computed tomography (CT) phantoms, with spot patterns of 3 × 3, 5 × 5, 7 × 7, and 9 × 9. Each individual spot delivered 2 × 10 7 protons, ensuring that the maximum physical dose per probing-beam irradiation remained below 0.5 Gy. A dual-panel in-beam PET system was simulated to reconstruct three-dimensional distributions of proton-induced positron-emitting activity. The reconstructed PET images, together with the corresponding CT images, served as inputs to neural network models that simultaneously predicted dose and LET distributions. The simulated datasets generated using nine CT phantoms were randomly divided into training (80%), validation (10%), and test (10%) sets. Model performance was quantitatively assessed using the mean relative error (MRE) and absolute range error (ARE). External generalization test and robustness evaluation were performed using two additional CT phantoms not included in model training. A preliminary feasibility evaluation using experimentally measured PET data was performed with an all-digital PET prototype and polymethyl methacrylate (PMMA) phantoms. Main results . Across all spot patterns, even under adverse perturbation conditions, the models generated reasonable dose and LET predictions. The maximum median ARE, dose MRE, and LET MRE were 0.97 mm, 1.68%, and 1.84%, respectively. For the experimentally measured data, the median ARE ranged from 0.38 mm to 2.37 mm, while the median dose and LET MRE varied from 2.05% to 4.06% and 2.06% to 3.02%, respectively. Significance . This study demonstrated the preliminary feasibility of simultaneously estimating three-dimensional dose and proton dose-averaged LET distributions from reconstructed in-beam PET and CT images under multi-spot single-energy probing-beam conditions. Further studies are required to establish quantitative dose-LET deviation criteria and to evaluate the additional value of the joint estimation framework for probing-beam delivery assessment.
- 20 August 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (16) , 165013
Estimation of dose and linear energy transfer for multi-spot single-energy proton probing beams using in-beam PET and neural network
Objective . In-beam positron emission tomography (PET) enables online measurements of proton-induced positron-emitting activity and has been widely investigated for in vivo range verification in proton therapy. This study proposes a neural network-based method for the simultaneous estimation of three-dimensional dose and linear energy transfer (LET) distributions from in-beam PET data following single-energy probing-beam irradiation. The performance and feasibility of the proposed method were investigated through Monte Carlo simulations and experimental measurements. Approach . Single-energy proton beams were delivered as probes to head computed tomography (CT) phantoms, with spot patterns of 3 × 3, 5 × 5, 7 × 7, and 9 × 9. Each individual spot delivered 2 × 10 7 protons, ensuring that the maximum physical dose per probing-beam irradiation remained below 0.5 Gy. A dual-panel in-beam PET system was simulated to reconstruct three-dimensional distributions of proton-induced positron-emitting activity. The reconstructed PET images, together with the corresponding CT images, served as inputs to neural network models that simultaneously predicted dose and LET distributions. The simulated datasets generated using nine CT phantoms were randomly divided into training (80%), validation (10%), and test (10%) sets. Model performance was quantitatively assessed using the mean relative error (MRE) and absolute range error (ARE). External generalization test and robustness evaluation were performed using two additional CT phantoms not included in model training. A preliminary feasibility evaluation using experimentally measured PET data was performed with an all-digital PET prototype and polymethyl methacrylate (PMMA) phantoms. Main results . Across all spot patterns, even under adverse perturbation conditions, the models generated reasonable dose and LET predictions. The maximum median ARE, dose MRE, and LET MRE were 0.97 mm, 1.68%, and 1.84%, respectively. For the experimentally measured data, the median ARE ranged from 0.38 mm to 2.37 mm, while the median dose and LET MRE varied from 2.05% to 4.06% and 2.06% to 3.02%, respectively. Significance . This study demonstrated the preliminary feasibility of simultaneously estimating three-dimensional dose and proton dose-averaged LET distributions from reconstructed in-beam PET and CT images under multi-spot single-energy probing-beam conditions. Further studies are required to establish quantitative dose-LET deviation criteria and to evaluate the additional value of the joint estimation framework for probing-beam delivery assessment.
- Open Access
- 19 June 2026
- Published by Springer Nature in Communications Biology
- Vol. 9 (1)
Sex-dependent neurobiological and metabolic dysfunction in an aged rat model of post-traumatic stress disorder
The neurobiological underpinnings of post-traumatic stress disorder (PTSD) in the elderly remain poorly characterized, particularly regarding sex-dependent vulnerabilities. This study systematically investigated sex-specific behavioral and metabolic alterations in 15-month-old rats using a single prolonged stress and footshock (SPS + FS) paradigm. A multimodal approach integrating behavioral analysis, 2-deoxy-2-[¹⁸F]fluoro-D-glucose positron emission tomography (FDG-PET) imaging, plasma endocrine profiling, and brain transcriptomics was employed to assess PTSD-related dysfunction. Behavioral assessments revealed that female rats exhibited more severe PTSD-like manifestations, indicating a higher susceptibility compared to males. Macroscopically, FDG-PET imaging identified prominent sex-specific alterations in glucose metabolism within the core fear circuitry, including the prefrontal cortex (PFC), hippocampus (Hipp), and amygdala (Amyg). In females, these metabolic shifts were more pronounced and strongly correlated with behavioral phenotypes. Dynamic PET further confirmed a general decline in the cerebral metabolic rate of glucose (CMRglu) across PTSD groups. Transcriptomic analysis validated these observations, revealing a systemic reprogramming of central metabolic networks in core brain regions. These neuroenergetic shifts appeared potentially associated with the dysregulation of key metabolic signaling networks, primarily the insulin and AMPK pathways, which exhibited notable sex-dependent spatial heterogeneity. These findings elucidate sex-specific metabolic and molecular abnormalities in aged PTSD models, advancing our understanding of elderly pathophysiology.
- 19 June 2026
- Published by Springer Nature in Communications Biology
- Vol. 9 (1)
Open AccessSex-dependent neurobiological and metabolic dysfunction in an aged rat model of post-traumatic stress disorder
The neurobiological underpinnings of post-traumatic stress disorder (PTSD) in the elderly remain poorly characterized, particularly regarding sex-dependent vulnerabilities. This study systematically investigated sex-specific behavioral and metabolic alterations in 15-month-old rats using a single prolonged stress and footshock (SPS + FS) paradigm. A multimodal approach integrating behavioral analysis, 2-deoxy-2-[¹⁸F]fluoro-D-glucose positron emission tomography (FDG-PET) imaging, plasma endocrine profiling, and brain transcriptomics was employed to assess PTSD-related dysfunction. Behavioral assessments revealed that female rats exhibited more severe PTSD-like manifestations, indicating a higher susceptibility compared to males. Macroscopically, FDG-PET imaging identified prominent sex-specific alterations in glucose metabolism within the core fear circuitry, including the prefrontal cortex (PFC), hippocampus (Hipp), and amygdala (Amyg). In females, these metabolic shifts were more pronounced and strongly correlated with behavioral phenotypes. Dynamic PET further confirmed a general decline in the cerebral metabolic rate of glucose (CMRglu) across PTSD groups. Transcriptomic analysis validated these observations, revealing a systemic reprogramming of central metabolic networks in core brain regions. These neuroenergetic shifts appeared potentially associated with the dysregulation of key metabolic signaling networks, primarily the insulin and AMPK pathways, which exhibited notable sex-dependent spatial heterogeneity. These findings elucidate sex-specific metabolic and molecular abnormalities in aged PTSD models, advancing our understanding of elderly pathophysiology.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (5) , 779-788
Head-to-Head Comparison of Brain Imaging Quality Between Brain-Dedicated PET and Whole-Body PET Based on Phantom and Clinical Data
A comprehensive comparison of imaging quality between the brain-dedicated all-digital PET system, DigitMI i30, and the whole-body DigitMI 930 system was performed using a series of phantom studies and clinical evaluations. Image quality was assessed with the point source and Derenzo phantom for spatial resolution, the National Electrical Manufacturers Association (NEMA) image quality phantom for contrast recovery coefficient and background variability, and the Hoffman phantom for gray-white matter contrast, signal-to-noise ratio (SNR), and coefficient of variation (COV). Clinical data were further analyzed to evaluate gray-white matter contrast, SNR, COV, and image sharpness. The DigitMI i30 achieved finer central spatial resolution (2.0 mm vs. 2.4 mm), although its resolution degraded faster than the DigitMI 930 with radial offset. In NEMA image quality tests, the DigitMI i30 exhibited higher contrast recovery coefficient (77.2% vs. 64.9%) and lower background variability (6.5% vs. 7.2%) for the 10 mm sphere. Hoffman phantom results and clinical data further confirmed its advantages, revealing sharper anatomical detail and improved gray-white matter contrast. These findings demonstrate that the physical advantages of a brain-dedicated PET system translate into clinically meaningful improvements, supporting its value as a precise and reliable tool for neuroimaging.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (5) , 779-788
Head-to-Head Comparison of Brain Imaging Quality Between Brain-Dedicated PET and Whole-Body PET Based on Phantom and Clinical Data
A comprehensive comparison of imaging quality between the brain-dedicated all-digital PET system, DigitMI i30, and the whole-body DigitMI 930 system was performed using a series of phantom studies and clinical evaluations. Image quality was assessed with the point source and Derenzo phantom for spatial resolution, the National Electrical Manufacturers Association (NEMA) image quality phantom for contrast recovery coefficient and background variability, and the Hoffman phantom for gray-white matter contrast, signal-to-noise ratio (SNR), and coefficient of variation (COV). Clinical data were further analyzed to evaluate gray-white matter contrast, SNR, COV, and image sharpness. The DigitMI i30 achieved finer central spatial resolution (2.0 mm vs. 2.4 mm), although its resolution degraded faster than the DigitMI 930 with radial offset. In NEMA image quality tests, the DigitMI i30 exhibited higher contrast recovery coefficient (77.2% vs. 64.9%) and lower background variability (6.5% vs. 7.2%) for the 10 mm sphere. Hoffman phantom results and clinical data further confirmed its advantages, revealing sharper anatomical detail and improved gray-white matter contrast. These findings demonstrate that the physical advantages of a brain-dedicated PET system translate into clinically meaningful improvements, supporting its value as a precise and reliable tool for neuroimaging.
- Open Access
- 21 December 2025
- Published by Association for Computing Machinery (ACM)
- p. 112-119
Application of a Domain Adaptation-Based Semi-Supervised Segmentation Framework for PET Imaging of GISTs
- 21 December 2025
- Published by Association for Computing Machinery (ACM)
- p. 112-119
Open AccessApplication of a Domain Adaptation-Based Semi-Supervised Segmentation Framework for PET Imaging of GISTs
- 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , P11007
Investigation of a variable multi-purpose preclinical PET system: a simulation study
Preclinical positron emission tomography (PET) has been widely applied in disease and biomedical research. Most existing preclinical PET systems are designed for imaging stationary small animals such as mice and rats. There is an increasing interest in systems that can accommodate imaging of animals of different sizes and freely moving subjects. In this study, we propose a variable multi-purpose preclinical PET system that enables gantry adaptation for imaging stationary animals of various sizes. By incorporating an optical motion tracking system and motion compensation techniques, the system also supports imaging of freely moving animals, accommodating diverse scenarios. Using GEANT4 application for tomographic emission (GATE) simulation software, we performed a preliminary evaluation of the PET system with three diameters: 102.4 mm (D100-PET), 204.8 mm (D200-PET), and 409.6 mm (D400-PET). The evaluation focused on sensitivity, spatial resolution, and imaging performance for both stationary and moving phantoms, with a depth-of-interaction (DOI) resolution of 3 mm. The D100-PET system achieved better sensitivity (16.0 % within 350–650 keV energy window) and radial resolution (1.39 mm (FWHM)) at the field of view (FOV) center. It also showed improved micro Derenzo phantom imaging. Under the simulated camera noise, the phantom's position was corrected in D400-PET system. The 1.2-mm rods remained visible in the motion-compensated images. These findings demonstrate the advantages of the system's variable gantry design and its capability for imaging freely moving targets, laying the foundation for future development of our real system.
- 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , P11007
Investigation of a variable multi-purpose preclinical PET system: a simulation study
Preclinical positron emission tomography (PET) has been widely applied in disease and biomedical research. Most existing preclinical PET systems are designed for imaging stationary small animals such as mice and rats. There is an increasing interest in systems that can accommodate imaging of animals of different sizes and freely moving subjects. In this study, we propose a variable multi-purpose preclinical PET system that enables gantry adaptation for imaging stationary animals of various sizes. By incorporating an optical motion tracking system and motion compensation techniques, the system also supports imaging of freely moving animals, accommodating diverse scenarios. Using GEANT4 application for tomographic emission (GATE) simulation software, we performed a preliminary evaluation of the PET system with three diameters: 102.4 mm (D100-PET), 204.8 mm (D200-PET), and 409.6 mm (D400-PET). The evaluation focused on sensitivity, spatial resolution, and imaging performance for both stationary and moving phantoms, with a depth-of-interaction (DOI) resolution of 3 mm. The D100-PET system achieved better sensitivity (16.0 % within 350–650 keV energy window) and radial resolution (1.39 mm (FWHM)) at the field of view (FOV) center. It also showed improved micro Derenzo phantom imaging. Under the simulated camera noise, the phantom's position was corrected in D400-PET system. The 1.2-mm rods remained visible in the motion-compensated images. These findings demonstrate the advantages of the system's variable gantry design and its capability for imaging freely moving targets, laying the foundation for future development of our real system.
- 30 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 582-592
Investigation of a Dual-Panel In-Beam PET Based on Digital Detectors for Proton Therapy Monitoring With Different Monitoring Strategies: A Simulation Study
In-beam positron emission tomography (PET) has shown great potential as a technology for proton therapy monitoring. Our group has developed a compact all-digital PET detector with high coincidence time resolution and energy resolution. Based on this detector, this study investigated the feasibility of a dual-panel in-beam PET (DiB-PET) system for proton therapy monitoring through Monte Carlo simulations. We designed a single-field treatment plan for an intracranial tumor and investigated three monitoring strategies: (1) monitoring the range of a single spot, (2) monitoring the range of a single midenergy layer, and (3) monitoring the range of a single-field plan. We introduced range deviations by varying the soft tissue density and evaluated the range verification accuracy by quantifying the linear relationship between activity range shift and dose range shift. With 120-second PET acquisition, DiB-PET achieved an average range verification accuracy of approximately 1.0 mm. This accuracy was consistent across all three monitoring strategies: on a spot-by-spot basis for both a single spot and a single mid-energy layer, as well as on a voxel-by-voxel basis for a single-field plan. These findings highlight DiB-PET’s high sensitivity and versatility, demonstrating its feasibility for proton therapy monitoring.
- 30 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 582-592
Investigation of a Dual-Panel In-Beam PET Based on Digital Detectors for Proton Therapy Monitoring With Different Monitoring Strategies: A Simulation Study
In-beam positron emission tomography (PET) has shown great potential as a technology for proton therapy monitoring. Our group has developed a compact all-digital PET detector with high coincidence time resolution and energy resolution. Based on this detector, this study investigated the feasibility of a dual-panel in-beam PET (DiB-PET) system for proton therapy monitoring through Monte Carlo simulations. We designed a single-field treatment plan for an intracranial tumor and investigated three monitoring strategies: (1) monitoring the range of a single spot, (2) monitoring the range of a single midenergy layer, and (3) monitoring the range of a single-field plan. We introduced range deviations by varying the soft tissue density and evaluated the range verification accuracy by quantifying the linear relationship between activity range shift and dose range shift. With 120-second PET acquisition, DiB-PET achieved an average range verification accuracy of approximately 1.0 mm. This accuracy was consistent across all three monitoring strategies: on a spot-by-spot basis for both a single spot and a single mid-energy layer, as well as on a voxel-by-voxel basis for a single-field plan. These findings highlight DiB-PET’s high sensitivity and versatility, demonstrating its feasibility for proton therapy monitoring.
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (2) , 218-228
Deep-Learning-Based PET Parallax Error Correction: A 2-D Simulation and Phantom Study
The parallax error (PE) significantly deteriorates the spatial resolution and imaging quality of positron emission tomography (PET) scanners. Existing PE correction methods either rely on depth decoding detectors in hardware which increases development costs, or optimize the system response matrix (SRM) in software providing limited compensation for PE. This work proposed a novel PE correction method in projection space based on deep learning (DL), consisting of two steps. First, the sinogram affected by PE was processed by a neural network (PEC-Net). The corrected sinogram output from the PEC-Net was then reconstructed to an improved image. To generate ideal PE-corrected labels, we synthesized training data using Monte Carlo (MC) simulation-based SRMs as forward projectors. The proposed method was validated using simulation data and real data. Experimental results show that the proposed method effectively eliminated artifacts caused by PE, and the reconstructed images of simulation data outperformed those obtained at 4 mm depth of interaction (DOI) resolution in terms of structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR). The PEC-Net may provide a low-cost, high-performance, software-based PE correction method for PET scanners without DOI measurement.
- 9 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (2) , 218-228
Deep-Learning-Based PET Parallax Error Correction: A 2-D Simulation and Phantom Study
The parallax error (PE) significantly deteriorates the spatial resolution and imaging quality of positron emission tomography (PET) scanners. Existing PE correction methods either rely on depth decoding detectors in hardware which increases development costs, or optimize the system response matrix (SRM) in software providing limited compensation for PE. This work proposed a novel PE correction method in projection space based on deep learning (DL), consisting of two steps. First, the sinogram affected by PE was processed by a neural network (PEC-Net). The corrected sinogram output from the PEC-Net was then reconstructed to an improved image. To generate ideal PE-corrected labels, we synthesized training data using Monte Carlo (MC) simulation-based SRMs as forward projectors. The proposed method was validated using simulation data and real data. Experimental results show that the proposed method effectively eliminated artifacts caused by PE, and the reconstructed images of simulation data outperformed those obtained at 4 mm depth of interaction (DOI) resolution in terms of structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR). The PEC-Net may provide a low-cost, high-performance, software-based PE correction method for PET scanners without DOI measurement.
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (5) , 578-585
Performance Evaluation of New PET/CT DigitMI 930
The study evaluates the performance of the DigitMI 930 PET/CT system, featuring detector modules with a 1:1:1 coupling of the scintillation crystal, the photosensor, and the electronic readout channel, in adherence to the NEMA NU 2-2018 standard. Moreover, brain and whole-body images were used to assess image quality. The radial, tangential, and axial resolutions at a radial offset of 1 cm were 3.9, 3.9, and 3.7 mm, respectively. The average sensitivity was measured at 16.2 cps/kBq. The peak noise-equivalent count rate was calculated as 412.5 kcps at 34.5 kBq/mL. At an activity concentration of 5.3 kBq/mL, the scatter fraction was 37.5%, and the time-of-flight (TOF) resolution was 248.6 ps. The contrast recovery coefficient ranged from 70.6 to 87.7% with TOF reconstruction. Despite increased noise in shorter whole-body scans, critical lesions remained identifiable at 20-second durations per bed position. The DigitMI 930 PET/CT system demonstrates a strong overall performance, particularly noteworthy for its low spatial resolution to crystal size ratio in comparison to other clinical PET systems. Moreover, the clinical studies indicate that the DigitMI 930 PET/CT system is capable of generating high-quality clinical images with high sensitivity for detecting small lesions, even at low injection doses or short scanning times.
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (5) , 578-585
Performance Evaluation of New PET/CT DigitMI 930
The study evaluates the performance of the DigitMI 930 PET/CT system, featuring detector modules with a 1:1:1 coupling of the scintillation crystal, the photosensor, and the electronic readout channel, in adherence to the NEMA NU 2-2018 standard. Moreover, brain and whole-body images were used to assess image quality. The radial, tangential, and axial resolutions at a radial offset of 1 cm were 3.9, 3.9, and 3.7 mm, respectively. The average sensitivity was measured at 16.2 cps/kBq. The peak noise-equivalent count rate was calculated as 412.5 kcps at 34.5 kBq/mL. At an activity concentration of 5.3 kBq/mL, the scatter fraction was 37.5%, and the time-of-flight (TOF) resolution was 248.6 ps. The contrast recovery coefficient ranged from 70.6 to 87.7% with TOF reconstruction. Despite increased noise in shorter whole-body scans, critical lesions remained identifiable at 20-second durations per bed position. The DigitMI 930 PET/CT system demonstrates a strong overall performance, particularly noteworthy for its low spatial resolution to crystal size ratio in comparison to other clinical PET systems. Moreover, the clinical studies indicate that the DigitMI 930 PET/CT system is capable of generating high-quality clinical images with high sensitivity for detecting small lesions, even at low injection doses or short scanning times.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (3) , 347-361
Enhancing Energy-Based Scatter Estimation Using Energy Spectra Modification in PET
Energy-based scatter estimation methods have illustrated promising results in recent literature. Accurate estimation of energy probability density function of scattered photons (PDF-SC) is essential for precise scatter estimation and avoiding bias in reconstructed images. This paper presents a novel method, referred to as energy spectra modification (ESM), to precisely estimate position-dependent local PDF-SC, which improves the accuracy of scatter estimation. ESM involves an iterative process to deblur local energy spectra, with the starting point constructed using an initial PDF-SC derived from global energy spectra. The scattered component of the deblurred energy spectrum is re-blurred and normalized to estimate the local PDF-SC. We validated this approach through Monte Carlo simulations using a bladder phantom, an image quality phantom, and a cylindrical phantom. Comparative analyses were conducted against the traditional method employing global PDF-SC, a recent advancement, and the single scatter simulation method. The results demonstrated that our method effectively reduced activity bias of the global PDF-SC approach across various energy resolutions, windows, target size, and count levels. It achieved this with a comparable computational load and without hyper-parameter modification.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (3) , 347-361
Enhancing Energy-Based Scatter Estimation Using Energy Spectra Modification in PET
Energy-based scatter estimation methods have illustrated promising results in recent literature. Accurate estimation of energy probability density function of scattered photons (PDF-SC) is essential for precise scatter estimation and avoiding bias in reconstructed images. This paper presents a novel method, referred to as energy spectra modification (ESM), to precisely estimate position-dependent local PDF-SC, which improves the accuracy of scatter estimation. ESM involves an iterative process to deblur local energy spectra, with the starting point constructed using an initial PDF-SC derived from global energy spectra. The scattered component of the deblurred energy spectrum is re-blurred and normalized to estimate the local PDF-SC. We validated this approach through Monte Carlo simulations using a bladder phantom, an image quality phantom, and a cylindrical phantom. Comparative analyses were conducted against the traditional method employing global PDF-SC, a recent advancement, and the single scatter simulation method. The results demonstrated that our method effectively reduced activity bias of the global PDF-SC approach across various energy resolutions, windows, target size, and count levels. It achieved this with a comparable computational load and without hyper-parameter modification.