Ang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ang Li has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Qingguo Xie
Huazhong University of Science and Technology
7 shared publications - Peng Xiao
Huazhong University of Science and Technology
5 shared publications Bingxuan Li
4 shared publications- Bingxuan Li
Institute of Artificial Intelligence, Hefei Comprehensive National Science Center, Hefei, China
4 shared publications - Lei Fang
Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China
4 shared publications Bo Zhang
Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, China
3 shared publications
Latest Publications
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
Performance Evaluation of a High-Sensitivity Preclinical PET/CT Scanner
The Trans-PET Explorist 180 Positron Emission Tomography/Computed Tomography (PET/CT) (E180) represents the most recent generation of the RAYCAN preclinical Trans-PET series, incorporating multi voltage threshold (MVT) readout technology. It features a transaxial field of view (FOV) of 160 mm and an axial FOV of 200 mm. This study aims to evaluate the performance of the E180 system according to the National Electrical Manufacturers Association (NEMA) NU4-2008 standards, alongside multi-phantom and animal studies to assess its performance in high-throughput scenarios. Employing 2D-filtered back projection (FBP) reconstruction, the system achieved a transaxial full width at half maximum (FWHM) resolution of (1.69 ± 0.12) mm at the center of the FOV. Derenzo phantom imaging resolved 1.20 mm size features. The peak absolute sensitivity was (7.6 ± 0.16)% within a 350 to 650 keV energy window. Scatter fractions were measured at (16 ± 1.3)%, (28 ± 1.8)%, and (47.0 ± 2.6)%, while peak noise equivalent count rates (NECRs) achieved (1540± 21) kcps at (129±3) MBq, (727±17) kcps at (94±4) MBq, and (100± 11) kcps at (114 ± 2) MBq for mouse-, rat-, and monkey-like phantoms, respectively. In the image quality phantom study, recovery coefficients (RCs) for the 1 mm to 5 mm rods ranged from (11.0±1.7)% to (113.8±2.8)%, with image uniformity of (7.0 ± 0.4)% and spill-over ratios (SORs) of (5.1 ± 1.3)% and (4.2 ± 0.9)% for the water- and air-filled regions, respectively. Dynamic imaging in both individual and multiple mice enabled clear visualization of ¹⁸F-FDG uptake kinetics within major organs, such as the brain and myocardium. Concurrent imaging of two and four image quality phantoms, alongside four mice, demonstrated the system's capability for simultaneous multi-target imaging. These features render the E180 exceptionally suitable for high-throughput dynamic imaging of experimental animals.
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
Performance Evaluation of a High-Sensitivity Preclinical PET/CT Scanner
The Trans-PET Explorist 180 Positron Emission Tomography/Computed Tomography (PET/CT) (E180) represents the most recent generation of the RAYCAN preclinical Trans-PET series, incorporating multi voltage threshold (MVT) readout technology. It features a transaxial field of view (FOV) of 160 mm and an axial FOV of 200 mm. This study aims to evaluate the performance of the E180 system according to the National Electrical Manufacturers Association (NEMA) NU4-2008 standards, alongside multi-phantom and animal studies to assess its performance in high-throughput scenarios. Employing 2D-filtered back projection (FBP) reconstruction, the system achieved a transaxial full width at half maximum (FWHM) resolution of (1.69 ± 0.12) mm at the center of the FOV. Derenzo phantom imaging resolved 1.20 mm size features. The peak absolute sensitivity was (7.6 ± 0.16)% within a 350 to 650 keV energy window. Scatter fractions were measured at (16 ± 1.3)%, (28 ± 1.8)%, and (47.0 ± 2.6)%, while peak noise equivalent count rates (NECRs) achieved (1540± 21) kcps at (129±3) MBq, (727±17) kcps at (94±4) MBq, and (100± 11) kcps at (114 ± 2) MBq for mouse-, rat-, and monkey-like phantoms, respectively. In the image quality phantom study, recovery coefficients (RCs) for the 1 mm to 5 mm rods ranged from (11.0±1.7)% to (113.8±2.8)%, with image uniformity of (7.0 ± 0.4)% and spill-over ratios (SORs) of (5.1 ± 1.3)% and (4.2 ± 0.9)% for the water- and air-filled regions, respectively. Dynamic imaging in both individual and multiple mice enabled clear visualization of ¹⁸F-FDG uptake kinetics within major organs, such as the brain and myocardium. Concurrent imaging of two and four image quality phantoms, alongside four mice, demonstrated the system's capability for simultaneous multi-target imaging. These features render the E180 exceptionally suitable for high-throughput dynamic imaging of experimental animals.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (5) , 779-788
Head-to-Head Comparison of Brain Imaging Quality Between Brain-Dedicated PET and Whole-Body PET Based on Phantom and Clinical Data
A comprehensive comparison of imaging quality between the brain-dedicated all-digital PET system, DigitMI i30, and the whole-body DigitMI 930 system was performed using a series of phantom studies and clinical evaluations. Image quality was assessed with the point source and Derenzo phantom for spatial resolution, the National Electrical Manufacturers Association (NEMA) image quality phantom for contrast recovery coefficient and background variability, and the Hoffman phantom for gray-white matter contrast, signal-to-noise ratio (SNR), and coefficient of variation (COV). Clinical data were further analyzed to evaluate gray-white matter contrast, SNR, COV, and image sharpness. The DigitMI i30 achieved finer central spatial resolution (2.0 mm vs. 2.4 mm), although its resolution degraded faster than the DigitMI 930 with radial offset. In NEMA image quality tests, the DigitMI i30 exhibited higher contrast recovery coefficient (77.2% vs. 64.9%) and lower background variability (6.5% vs. 7.2%) for the 10 mm sphere. Hoffman phantom results and clinical data further confirmed its advantages, revealing sharper anatomical detail and improved gray-white matter contrast. These findings demonstrate that the physical advantages of a brain-dedicated PET system translate into clinically meaningful improvements, supporting its value as a precise and reliable tool for neuroimaging.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (5) , 779-788
Head-to-Head Comparison of Brain Imaging Quality Between Brain-Dedicated PET and Whole-Body PET Based on Phantom and Clinical Data
A comprehensive comparison of imaging quality between the brain-dedicated all-digital PET system, DigitMI i30, and the whole-body DigitMI 930 system was performed using a series of phantom studies and clinical evaluations. Image quality was assessed with the point source and Derenzo phantom for spatial resolution, the National Electrical Manufacturers Association (NEMA) image quality phantom for contrast recovery coefficient and background variability, and the Hoffman phantom for gray-white matter contrast, signal-to-noise ratio (SNR), and coefficient of variation (COV). Clinical data were further analyzed to evaluate gray-white matter contrast, SNR, COV, and image sharpness. The DigitMI i30 achieved finer central spatial resolution (2.0 mm vs. 2.4 mm), although its resolution degraded faster than the DigitMI 930 with radial offset. In NEMA image quality tests, the DigitMI i30 exhibited higher contrast recovery coefficient (77.2% vs. 64.9%) and lower background variability (6.5% vs. 7.2%) for the 10 mm sphere. Hoffman phantom results and clinical data further confirmed its advantages, revealing sharper anatomical detail and improved gray-white matter contrast. These findings demonstrate that the physical advantages of a brain-dedicated PET system translate into clinically meaningful improvements, supporting its value as a precise and reliable tool for neuroimaging.
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (5) , 578-585
Performance Evaluation of New PET/CT DigitMI 930
The study evaluates the performance of the DigitMI 930 PET/CT system, featuring detector modules with a 1:1:1 coupling of the scintillation crystal, the photosensor, and the electronic readout channel, in adherence to the NEMA NU 2-2018 standard. Moreover, brain and whole-body images were used to assess image quality. The radial, tangential, and axial resolutions at a radial offset of 1 cm were 3.9, 3.9, and 3.7 mm, respectively. The average sensitivity was measured at 16.2 cps/kBq. The peak noise-equivalent count rate was calculated as 412.5 kcps at 34.5 kBq/mL. At an activity concentration of 5.3 kBq/mL, the scatter fraction was 37.5%, and the time-of-flight (TOF) resolution was 248.6 ps. The contrast recovery coefficient ranged from 70.6 to 87.7% with TOF reconstruction. Despite increased noise in shorter whole-body scans, critical lesions remained identifiable at 20-second durations per bed position. The DigitMI 930 PET/CT system demonstrates a strong overall performance, particularly noteworthy for its low spatial resolution to crystal size ratio in comparison to other clinical PET systems. Moreover, the clinical studies indicate that the DigitMI 930 PET/CT system is capable of generating high-quality clinical images with high sensitivity for detecting small lesions, even at low injection doses or short scanning times.
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (5) , 578-585
Performance Evaluation of New PET/CT DigitMI 930
The study evaluates the performance of the DigitMI 930 PET/CT system, featuring detector modules with a 1:1:1 coupling of the scintillation crystal, the photosensor, and the electronic readout channel, in adherence to the NEMA NU 2-2018 standard. Moreover, brain and whole-body images were used to assess image quality. The radial, tangential, and axial resolutions at a radial offset of 1 cm were 3.9, 3.9, and 3.7 mm, respectively. The average sensitivity was measured at 16.2 cps/kBq. The peak noise-equivalent count rate was calculated as 412.5 kcps at 34.5 kBq/mL. At an activity concentration of 5.3 kBq/mL, the scatter fraction was 37.5%, and the time-of-flight (TOF) resolution was 248.6 ps. The contrast recovery coefficient ranged from 70.6 to 87.7% with TOF reconstruction. Despite increased noise in shorter whole-body scans, critical lesions remained identifiable at 20-second durations per bed position. The DigitMI 930 PET/CT system demonstrates a strong overall performance, particularly noteworthy for its low spatial resolution to crystal size ratio in comparison to other clinical PET systems. Moreover, the clinical studies indicate that the DigitMI 930 PET/CT system is capable of generating high-quality clinical images with high sensitivity for detecting small lesions, even at low injection doses or short scanning times.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (3) , 347-361
Enhancing Energy-Based Scatter Estimation Using Energy Spectra Modification in PET
Energy-based scatter estimation methods have illustrated promising results in recent literature. Accurate estimation of energy probability density function of scattered photons (PDF-SC) is essential for precise scatter estimation and avoiding bias in reconstructed images. This paper presents a novel method, referred to as energy spectra modification (ESM), to precisely estimate position-dependent local PDF-SC, which improves the accuracy of scatter estimation. ESM involves an iterative process to deblur local energy spectra, with the starting point constructed using an initial PDF-SC derived from global energy spectra. The scattered component of the deblurred energy spectrum is re-blurred and normalized to estimate the local PDF-SC. We validated this approach through Monte Carlo simulations using a bladder phantom, an image quality phantom, and a cylindrical phantom. Comparative analyses were conducted against the traditional method employing global PDF-SC, a recent advancement, and the single scatter simulation method. The results demonstrated that our method effectively reduced activity bias of the global PDF-SC approach across various energy resolutions, windows, target size, and count levels. It achieved this with a comparable computational load and without hyper-parameter modification.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (3) , 347-361
Enhancing Energy-Based Scatter Estimation Using Energy Spectra Modification in PET
Energy-based scatter estimation methods have illustrated promising results in recent literature. Accurate estimation of energy probability density function of scattered photons (PDF-SC) is essential for precise scatter estimation and avoiding bias in reconstructed images. This paper presents a novel method, referred to as energy spectra modification (ESM), to precisely estimate position-dependent local PDF-SC, which improves the accuracy of scatter estimation. ESM involves an iterative process to deblur local energy spectra, with the starting point constructed using an initial PDF-SC derived from global energy spectra. The scattered component of the deblurred energy spectrum is re-blurred and normalized to estimate the local PDF-SC. We validated this approach through Monte Carlo simulations using a bladder phantom, an image quality phantom, and a cylindrical phantom. Comparative analyses were conducted against the traditional method employing global PDF-SC, a recent advancement, and the single scatter simulation method. The results demonstrated that our method effectively reduced activity bias of the global PDF-SC approach across various energy resolutions, windows, target size, and count levels. It achieved this with a comparable computational load and without hyper-parameter modification.
- 29 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175018
Timing offset calibration for TOF PET using stationary line source scans at multiple positions
Background. Accurate timing offset calibration is crucial for time-of-flight (TOF) positron emission tomography (PET) to mitigate image artifacts and improve quantitative accuracy. However, existing methods are often time-consuming, complex, or costly. Objective. This paper presents a method for TOF PET timing offset calibration that eliminates the need for costly equipment, phantoms, short-half-life sources, and precise source positioning. Approach. We estimate channel timing offsets using stationary scans of a 68Ge line source, typically used for routine quality control, at a minimum of three non-coplanar positions, with each position scanned for two minutes. The line source positions are accurately determined by applying a simple algorithm to their reconstructed images, allowing precise calculation of arrival time differences. Channel timing offsets are estimated by solving a least squares problem. This method is assessed through analyses of phantoms and patient images using a RAYSOLUTION DigitMI 930 scanner. Main results. The estimated timing offsets ranged from –500 ps to 500 ps across all channels. Calibration with a minimum of three scanned positions was sufficient to correct these offsets, achieving less than a 1% discrepancy across various metrics of the image quality (IQ) phantom compared to 12 positions. This calibration significantly reduced edge artifacts in TOF reconstruction of both phantoms and patients. Furthermore, the IQ phantom displayed a 14% increase in average contrast recovery, a 61% reduction in average background variability across all spheres, and a 90% reduction in average residual error. Consistent with the phantom results, patient data revealed enhancements in maximum standardized uptake values (SUVmax) from 14% to 55% for lesions measuring 6 mm to 14 mm. The calibration also improved lesion-to-background contrast and eliminated artifacts caused by the spillover effect of the kidneys and bladder. Significance. The proposed method is fast, user-friendly, and cost-effective, effectively improving lesion detection and diagnostic accuracy.
- 29 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175018
Timing offset calibration for TOF PET using stationary line source scans at multiple positions
Background. Accurate timing offset calibration is crucial for time-of-flight (TOF) positron emission tomography (PET) to mitigate image artifacts and improve quantitative accuracy. However, existing methods are often time-consuming, complex, or costly. Objective. This paper presents a method for TOF PET timing offset calibration that eliminates the need for costly equipment, phantoms, short-half-life sources, and precise source positioning. Approach. We estimate channel timing offsets using stationary scans of a 68Ge line source, typically used for routine quality control, at a minimum of three non-coplanar positions, with each position scanned for two minutes. The line source positions are accurately determined by applying a simple algorithm to their reconstructed images, allowing precise calculation of arrival time differences. Channel timing offsets are estimated by solving a least squares problem. This method is assessed through analyses of phantoms and patient images using a RAYSOLUTION DigitMI 930 scanner. Main results. The estimated timing offsets ranged from –500 ps to 500 ps across all channels. Calibration with a minimum of three scanned positions was sufficient to correct these offsets, achieving less than a 1% discrepancy across various metrics of the image quality (IQ) phantom compared to 12 positions. This calibration significantly reduced edge artifacts in TOF reconstruction of both phantoms and patients. Furthermore, the IQ phantom displayed a 14% increase in average contrast recovery, a 61% reduction in average background variability across all spheres, and a 90% reduction in average residual error. Consistent with the phantom results, patient data revealed enhancements in maximum standardized uptake values (SUVmax) from 14% to 55% for lesions measuring 6 mm to 14 mm. The calibration also improved lesion-to-background contrast and eliminated artifacts caused by the spillover effect of the kidneys and bladder. Significance. The proposed method is fast, user-friendly, and cost-effective, effectively improving lesion detection and diagnostic accuracy.
- Open Access
- 5 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (16) , 165019
Deep denoiser prior driven relaxed iterated Tikhonov method for low-count PET image restoration
Objective. Low-count positron emission tomography (PET) imaging is an efficient way to promote more widespread use of PET because of its short scan time and low injected activity. However, this often leads to low-quality PET images with clinical image reconstruction, due to high noise and blurring effects. Existing PET image restoration (IR) methods hinder their own restoration performance due to the semi-convergence property and the lack of suitable denoiser prior. Approach. To overcome these limitations, we propose a novel deep plug-and-play IR method called Deep denoiser Prior driven Relaxed Iterated Tikhonov method (DP-RI-Tikhonov). Specifically, we train a deep convolutional neural network denoiser to generate a flexible deep denoiser prior to handle high noise. Then, we plug the deep denoiser prior as a modular part into a novel iterative optimization algorithm to handle blurring effects and propose an adaptive parameter selection strategy for the iterative optimization algorithm. Main results. Simulation results show that the deep denoiser prior plays the role of reducing noise intensity, while the novel iterative optimization algorithm and adaptive parameter selection strategy can effectively eliminate the semi-convergence property. They enable DP-RI-Tikhonov to achieve an average quantitative result (normalized root mean square error, structural similarity) of (0.1364, 0.9574) at the stopping iteration, outperforming a conventional PET IR method with an average quantitative result of (0.1533, 0.9523) and a state-of-the-art deep plug-and-play IR method with an average quantitative result of (0.1404, 0.9554). Moreover, the advantage of DP-RI-Tikhonov becomes more obvious at the last iteration. Experiments on six clinical whole-body PET images further indicate that DP-RI-Tikhonov successfully reduces noise intensity and recovers fine details, recovering sharper and more uniform images than the comparison methods. Significance. DP-RI-Tikhonov’s ability to reduce noise intensity and effectively eliminate the semi-convergence property overcomes the limitations of existing methods. This advancement may have substantial implications for other medical IR.
- 5 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (16) , 165019
Open AccessDeep denoiser prior driven relaxed iterated Tikhonov method for low-count PET image restoration
Objective. Low-count positron emission tomography (PET) imaging is an efficient way to promote more widespread use of PET because of its short scan time and low injected activity. However, this often leads to low-quality PET images with clinical image reconstruction, due to high noise and blurring effects. Existing PET image restoration (IR) methods hinder their own restoration performance due to the semi-convergence property and the lack of suitable denoiser prior. Approach. To overcome these limitations, we propose a novel deep plug-and-play IR method called Deep denoiser Prior driven Relaxed Iterated Tikhonov method (DP-RI-Tikhonov). Specifically, we train a deep convolutional neural network denoiser to generate a flexible deep denoiser prior to handle high noise. Then, we plug the deep denoiser prior as a modular part into a novel iterative optimization algorithm to handle blurring effects and propose an adaptive parameter selection strategy for the iterative optimization algorithm. Main results. Simulation results show that the deep denoiser prior plays the role of reducing noise intensity, while the novel iterative optimization algorithm and adaptive parameter selection strategy can effectively eliminate the semi-convergence property. They enable DP-RI-Tikhonov to achieve an average quantitative result (normalized root mean square error, structural similarity) of (0.1364, 0.9574) at the stopping iteration, outperforming a conventional PET IR method with an average quantitative result of (0.1533, 0.9523) and a state-of-the-art deep plug-and-play IR method with an average quantitative result of (0.1404, 0.9554). Moreover, the advantage of DP-RI-Tikhonov becomes more obvious at the last iteration. Experiments on six clinical whole-body PET images further indicate that DP-RI-Tikhonov successfully reduces noise intensity and recovers fine details, recovering sharper and more uniform images than the comparison methods. Significance. DP-RI-Tikhonov’s ability to reduce noise intensity and effectively eliminate the semi-convergence property overcomes the limitations of existing methods. This advancement may have substantial implications for other medical IR.
- 12 January 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (2) , 025019
Development and evaluation of a new high-TOF-resolution all-digital brain PET system
Objective. Time-of-flight (TOF) capability and high sensitivity are essential for brain-dedicated positron emission tomography (PET) imaging, as they improve the contrast and the signal-to-noise ratio (SNR) enabling a precise localization of functional mechanisms in the different brain regions. Approach. We present a new brain PET system with transverse and axial field-of-view (FOV) of 320 mm and 255 mm, respectively. The system head is an array of 6 × 6 detection elements, each consisting of a 3.9 × 3.9 × 20 mm 3 lutetium–yttrium oxyorthosilicate crystal coupled with a 3.93 × 3.93 mm 2 SiPM. The SiPMs analog signals are individually digitized using the multi-voltage threshold (MVT) technology, employing a 1:1:1 coupling configuration. Main results. The brain PET system exhibits a TOF resolution of 249 ps at 5.3 kBq ml −1 , an average sensitivity of 22.1 cps kBq −1 , and a noise equivalent count rate (NECR) peak of 150.9 kcps at 8.36 kBq ml −1 . Furthermore, the mini-Derenzo phantom study demonstrated the system’s ability to distinguish rods with a diameter of 2.0 mm. Moreover, incorporating the TOF reconstruction algorithm in an image quality phantom study optimizes the background variability, resulting in reductions ranging from 44% (37 mm) to 75% (10 mm) with comparable contrast. In the human brain imaging study, the SNR improved by a factor of 1.7 with the inclusion of TOF, increasing from 27.07 to 46.05. Time-dynamic human brain imaging was performed, showing the distinctive traits of cortex and thalamus uptake, as well as of the arterial and venous flow with 2 s per time frame. Significance. The system exhibited a good TOF capability, which is coupled with the high sensitivity and count rate performance based on the MVT digital sampling technique. The developed TOF-enabled brain PET system opens the possibility of precise kinetic brain PET imaging, towards new quantitative predictive brain diagnostics.
- 12 January 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (2) , 025019
Development and evaluation of a new high-TOF-resolution all-digital brain PET system
Objective. Time-of-flight (TOF) capability and high sensitivity are essential for brain-dedicated positron emission tomography (PET) imaging, as they improve the contrast and the signal-to-noise ratio (SNR) enabling a precise localization of functional mechanisms in the different brain regions. Approach. We present a new brain PET system with transverse and axial field-of-view (FOV) of 320 mm and 255 mm, respectively. The system head is an array of 6 × 6 detection elements, each consisting of a 3.9 × 3.9 × 20 mm 3 lutetium–yttrium oxyorthosilicate crystal coupled with a 3.93 × 3.93 mm 2 SiPM. The SiPMs analog signals are individually digitized using the multi-voltage threshold (MVT) technology, employing a 1:1:1 coupling configuration. Main results. The brain PET system exhibits a TOF resolution of 249 ps at 5.3 kBq ml −1 , an average sensitivity of 22.1 cps kBq −1 , and a noise equivalent count rate (NECR) peak of 150.9 kcps at 8.36 kBq ml −1 . Furthermore, the mini-Derenzo phantom study demonstrated the system’s ability to distinguish rods with a diameter of 2.0 mm. Moreover, incorporating the TOF reconstruction algorithm in an image quality phantom study optimizes the background variability, resulting in reductions ranging from 44% (37 mm) to 75% (10 mm) with comparable contrast. In the human brain imaging study, the SNR improved by a factor of 1.7 with the inclusion of TOF, increasing from 27.07 to 46.05. Time-dynamic human brain imaging was performed, showing the distinctive traits of cortex and thalamus uptake, as well as of the arterial and venous flow with 2 s per time frame. Significance. The system exhibited a good TOF capability, which is coupled with the high sensitivity and count rate performance based on the MVT digital sampling technique. The developed TOF-enabled brain PET system opens the possibility of precise kinetic brain PET imaging, towards new quantitative predictive brain diagnostics.
- 7 June 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (4) , 045009
Evaluation of applying space-variant resolution modeling to attenuation correction in PET
Attenuation correction aims to recover the underestimated tracer uptake and improve the image contrast recovery in positron emission tomography (PET). However, traditional ray-tracing-based projection of attenuation maps is inaccurate as some physical effects are not considered, such as finite crystal size, inter-crystal penetration and inter-crystal scatter. In this study, we evaluated the effects of applying resolution modeling (RM) to attenuation correction by implementing space-variant RM to complement physical effects which are usually omitted in the traditional projection model. We verified this method on a brain PET scanner developed by our group, in both Monte Carlo simulation and real-world data, in comparison with space-invariant Gaussian RM, average-depth-of-interaction, and multi-ray tracing methods. The results indicate that the space-variant RM is superior in terms of artifacts reduction and contrast recovery.
- 7 June 2022
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (4) , 045009
Evaluation of applying space-variant resolution modeling to attenuation correction in PET
Attenuation correction aims to recover the underestimated tracer uptake and improve the image contrast recovery in positron emission tomography (PET). However, traditional ray-tracing-based projection of attenuation maps is inaccurate as some physical effects are not considered, such as finite crystal size, inter-crystal penetration and inter-crystal scatter. In this study, we evaluated the effects of applying resolution modeling (RM) to attenuation correction by implementing space-variant RM to complement physical effects which are usually omitted in the traditional projection model. We verified this method on a brain PET scanner developed by our group, in both Monte Carlo simulation and real-world data, in comparison with space-invariant Gaussian RM, average-depth-of-interaction, and multi-ray tracing methods. The results indicate that the space-variant RM is superior in terms of artifacts reduction and contrast recovery.