JCJae-Wook Choi

Jae-Wook Choi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jae-Wook Choi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reduced Copper Piping Corrosion in Sprinkler Facilities

    by Chul-Hwan Mun, Yu-Jung Choi, Jae-Wook Choi

    Copper pipes used in fire sprinkler systems are somewhat superior to steel pipes in terms of corrosion resistance. They have been widely used in apartments since 2010, but their firefighting performance has not been firmly established due to leakage caused by pitting. In order to solve this problem, copper pipes need to be replaced by pipes made of other materials such as STS or C-PVC, which, however, would impose an economic burden on the party responsible for maintenance, as well as economic loss to other relevant parties and inconvenience to residents. Although 27 leakages occurred in the E region in 2018, it was found that the number of incidents was reduced to just one case after an application of corrosion inhibitor. Therefore, for 2 months beginning in October 2020, a second project to reduce piping corrosion was conducted with 2,000 households in five regions nationwide. During this period, the standing fire water of five apartment buildings in the A region was measured as having a pH 8.34–9.08, an ORP -94.9–-135.8 mV, and an EC 0.097–0.137 ms/cm, which indicated a need for improvement. Subsequently, a corrosion inhibitor was poured into the fire water, resulting in improved values of pH 11.13–11.26, ORP -257–-265.5 mV, and EC 4.189–5.769 ms/cm, which demonstrated the effect of preventing pipe corrosion. It was evident that water-soluble silicate was adsorbed on the metal pipe of the anode to form a thin monolayer, which induced basicity by increasing the pH and by decreasing the ORP, which eventually minimized corrosion.


  • Open Access

    Study on the Risk Assessment of Spontaneous Ignition and of Perilla Oil Cakes Associated Activation Energy

    by Sung-Ho Byun, Yu-Jung Choi, Jae-Hoon Jeong, Jae-Wook Choi

    Perilla oil cakes are the residues of oil pressing processes, and used as fertilizers, feedstuff, food, etc. However, according to recent reports, perilla oil cakes often ignite spontaneously due to scorching heat, particularly in rice mills, general mills, and oil mills where large amounts of perilla oil cakes are stored. Thus, in this study, we attempted to elucidate the risk of spontaneous ignition of perilla oil cakes. For this purpose, thermogravimetry/differential thermal analysis (TG-DTA) was performed to identify thermal properties like weight reduction and heat generation, and spontaneous ignition was conducted for sample vessels of different thicknesses. The results showed that the ignition temperature of perilla oil cakes was 115 ℃ for the small (20 cm × 20 cm × 3 cm) vessel. The apparent activation energy associated with the critical ignition temperature was 60.74 kJ/mol. The ignition delay time and the time to reach maximum temperature were both found to increase with increasing vessel thickness. It was concluded that proper protection against heat must be in place because fire risk increases and spontaneous ignition can occur when large amounts of perilla oil cakes are accumulated.

  • Open Access

    A Study on the Relationship between Firefighters Disease and Health Status

    by Ho-Jung Kang, Sung-Ho Byun, Chul-Hwan Mun, Yu-Jung Choi, Jae-Wook Choi

    Considering the age and longer service time of firefighters who have a substantial amount of field activities, they are exposed to chemical and biological risk factors, physical and mental stress, diverse and complex work environments, and repetitive motions, which may increase the rates of gastrointestinal disorders, musculoskeletal diseases, cancers, and cardiovascular diseases. Therefore, based on the regular specific health examination results for 215 firefighters who were working in the N fire department located in B metropolitan city, an analysis of occupational diseases was performed, which showed that the most common chronic disease was diabetes mellitus (28.8%), followed by hyperlipidemia (27.9%) and thoracic diseases (19.5%). This trend appears to be consistent with the incidence rates reported in a representative study of adult diseases in Korea. In addition, it was found that 82 officers maintained healthy states, while those who needed further medical inspection and those with clinical symptoms were more frequently exposed to disease when they were older and had longer service time; moreover, the fire captain and lieutenant had higher rates of disease.


  • Open Access

    A Study on the Application of Hydraulic Calculations considering the Corrosion Coefficient of Steel Piping for Fire Protection

    by Chul-Hwan Mun, Ho-Jung Kang, Jae-Wook Choi

    With the recent enlargement and complication of buildings, damage caused by the incidents of fires breaking out are escalating. Consequently, the use of sprinkler facilities is increasing among water-based fire extinguishing systems. Piping materials used in fire prevention systems include carbon steel (for general or pressure pipeline), CPVC, copper, and stainless-steel. Among these, the steel and CPVC pipes, which are commonly employed in fire prevention, were considered for testing the reliability of the water-based systems. This analysis was performed using the PIPENET software to perform hydraulic calculations in order to examine the flow and pressure at the terminal head when the corrosion coefficient was applied; this coefficient was applied considering the aging of pipes. Assuming a uniform pipe diameter in the steel pipes, the rated flow in the pump installed on the first floor of the basement was reduced by over 10% after 20 years had passed (C value of 90); moreover, the reduction in pressure and flow at its terminal head exceeded 30% and 16.5%, respectively. The results indicate that it is difficult to ensure the reliability of these fire prevention facilities. Furthermore, according to our estimation, considering 30 years had passed (C value of 80), the rated flow of the pump was reduced by over 15%, and the corresponding reduction in pressure and flow at its terminal head exceeded 42% and 24%, respectively.


  • Open Access

    Analysis of Cause of Fire and Explosion in Internal Floating Roof Tank: Focusing on Fire and Explosion Accidents at the OO Oil Pipeline Corporation

    by Chae-Chil Koo, Jae-Wook Choi

    This study aims to maintain the safety of an outdoor storage tank through the fundamental case analysis of explosion and fire accidents in the storage tank. We consider an accident caused by the explosion of fire inside the tank, as a result of the gradual spreading of the residual fire generated by wind lamps flying off a workplace in the storage tank yard. To determine the cause of the accident, atmospheric diffusion conditions were derived through CCTV image analysis, and the wind direction was analyzed using computational fluid dynamics. Additionally, the amount of oil vapor inside the tank when the floating roof was at the lowest position, and the behavior of the vapor inside the tank when the floating roof was at the highest position were investigated. If the cause of the explosion in the storage tank is identified and the level of the storage tank is maintained below the internal floating roof, dangerous liquid fills the storage tank, and the vapor in the space may stagnate on the internal floating roof. We intend to improve the operation procedure such that the level of the storage tank is not under the Pontoon support, as well as provide measures to prevent flames from entering the storage tank by installing a flame arrester in the open vent of the tank.