Chang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Chang Liu has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Kai Wei
Beihang University
5 shared publications - Zitong Xu
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
5 shared publications - Dinghui Gong
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
4 shared publications - Wei Quan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
4 shared publications - Xiaofei Huang
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
4 shared publications - Xing Heng
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
4 shared publications
Latest Publications
- 24 August 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (8)
In situ decoupling of pump-induced spin polarization noise in atomic spin sensors
In atomic spin sensors based on optical pumping, pump beam instabilities can drive atomic spin polarization fluctuations, referred to here as pump-induced spin polarization noise, which may limit sensitivity and long-term stability. Because the local pump field inside the cell can differ from that inferred from external optical diagnostics, it remains difficult to directly quantify the actual in situ spin polarization noise and to evaluate and suppress its contribution to the sensor noise floor. Here, we propose an in situ decoupling method based on spin dynamics, in which a large longitudinal detuning field suppresses magnetic field and rotation responses, while a transverse projection field converts pump-induced fluctuations in longitudinal spin polarization into a measurable transverse spin signal. Demonstrated in a K-Rb-21Ne spin exchange relaxation free (SERF) comagnetometer, the proposed method suppresses the magnetic-field response by approximately 180-fold and enhances the pump-power-noise response by approximately 380-fold, thereby enabling effective separation and evaluation of pump-induced spin polarization noise. The method employs the atomic ensemble as an in situ probe of the spin dynamic response to the local pump optical field. It enables quantitative identification of pump fluctuation associated noise and direct evaluation of optical field stability under actual operating conditions, thereby providing an experimental basis for optical field stabilization and noise suppression assessment in SERF comagnetometers and related alkali atomic spin sensors.
- 24 August 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (8)
In situ decoupling of pump-induced spin polarization noise in atomic spin sensors
In atomic spin sensors based on optical pumping, pump beam instabilities can drive atomic spin polarization fluctuations, referred to here as pump-induced spin polarization noise, which may limit sensitivity and long-term stability. Because the local pump field inside the cell can differ from that inferred from external optical diagnostics, it remains difficult to directly quantify the actual in situ spin polarization noise and to evaluate and suppress its contribution to the sensor noise floor. Here, we propose an in situ decoupling method based on spin dynamics, in which a large longitudinal detuning field suppresses magnetic field and rotation responses, while a transverse projection field converts pump-induced fluctuations in longitudinal spin polarization into a measurable transverse spin signal. Demonstrated in a K-Rb-21Ne spin exchange relaxation free (SERF) comagnetometer, the proposed method suppresses the magnetic-field response by approximately 180-fold and enhances the pump-power-noise response by approximately 380-fold, thereby enabling effective separation and evaluation of pump-induced spin polarization noise. The method employs the atomic ensemble as an in situ probe of the spin dynamic response to the local pump optical field. It enables quantitative identification of pump fluctuation associated noise and direct evaluation of optical field stability under actual operating conditions, thereby providing an experimental basis for optical field stabilization and noise suppression assessment in SERF comagnetometers and related alkali atomic spin sensors.
- 30 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Decoupling Method of Triaxial Magnetic Field Compensation and Multiparameter Measurement in Comagnetometers
Spin exchange relaxation free (SERF) comagnetometers possess considerable potential for applications in fundamental physics research and inertial navigation. Operating comagnetometers at the magnetic field compensation point and performing multi-parameter measurement are fundamental to reducing the magnetic noise and maintaining high performance. However, the crosstalk among the triaxial magnetic fields diminishes the effectiveness and accuracy of magnetic field compensation and multi-parameter measurement. To address this limitation, we propose a novel method for in-situ rapid and accurate magnetic field compensation and multi-parameter measurement. The decoupling of the triaxial magnetic fields, achieved experimentally through first-order and second-order approximations based on the modulation dynamics of coupled electronic-nuclear spins, enables the direct determination of the magnetic field compensation point. Additionally, the method facilitates the derivation of both the scale factor and the electronic spin relaxation rate. The proposed method addresses the issue of triaxial magnetic field coupling, enhancing the accuracy and efficiency of magnetic compensation and multi-parameter measurement. The proposed method saves more than 70compared to the non-decoupled method, maintaining magnetic field compensation accuracy within 0.2 nT. It demonstrates promising potential for precise magnetic field manipulation and real-time closed-loop control of comagnetometers.
- 30 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Decoupling Method of Triaxial Magnetic Field Compensation and Multiparameter Measurement in Comagnetometers
Spin exchange relaxation free (SERF) comagnetometers possess considerable potential for applications in fundamental physics research and inertial navigation. Operating comagnetometers at the magnetic field compensation point and performing multi-parameter measurement are fundamental to reducing the magnetic noise and maintaining high performance. However, the crosstalk among the triaxial magnetic fields diminishes the effectiveness and accuracy of magnetic field compensation and multi-parameter measurement. To address this limitation, we propose a novel method for in-situ rapid and accurate magnetic field compensation and multi-parameter measurement. The decoupling of the triaxial magnetic fields, achieved experimentally through first-order and second-order approximations based on the modulation dynamics of coupled electronic-nuclear spins, enables the direct determination of the magnetic field compensation point. Additionally, the method facilitates the derivation of both the scale factor and the electronic spin relaxation rate. The proposed method addresses the issue of triaxial magnetic field coupling, enhancing the accuracy and efficiency of magnetic compensation and multi-parameter measurement. The proposed method saves more than 70compared to the non-decoupled method, maintaining magnetic field compensation accuracy within 0.2 nT. It demonstrates promising potential for precise magnetic field manipulation and real-time closed-loop control of comagnetometers.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Analysis and Suppression for Critical Optical Nonorthogonal Noise in SERF Comagnetometers
Ultrasensitive atomic comagnetometers have proven to be valuable tools for precise measurement and search for new physics. Besides, comagnetometers have potential for inertial navigation and quantum information. Despite their great potential, sensitivity improvement has been limited by different types of noise. To address this issue, the sources and magnitudes of noises are comprehensively analyzed and a suppression method is proposed for the most critical noise source, optical nonorthogonality. The optical nonorthogonality leads to critical transverse pumping effect, thus transverse light shift, and transverse effective magnetic noise. A direct correlation between the optical nonorthogonality and the electronic spin transverse relaxation rate is found, and a method for suppression of the optical nonorthogonality is proposed accordingly. Finally, the optical nonorthogonal noise is suppressed by 3.1 dB. Besides, an increase of 5.2 dB in the scale factor is achieved. With the combined effect of noise suppression and scale factor enhancement, the resulting inertial rotation sensitivity of $2.4 \times 10^{-8}$ rad/s/Hz $^{1/2}$ in the frequency range from 1 to 3 Hz is among the most sensitive comagnetometers, which opens up promising opportunities for new physics measurements, such as the search for ultralight dark matter and the fifth force.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Analysis and Suppression for Critical Optical Nonorthogonal Noise in SERF Comagnetometers
Ultrasensitive atomic comagnetometers have proven to be valuable tools for precise measurement and search for new physics. Besides, comagnetometers have potential for inertial navigation and quantum information. Despite their great potential, sensitivity improvement has been limited by different types of noise. To address this issue, the sources and magnitudes of noises are comprehensively analyzed and a suppression method is proposed for the most critical noise source, optical nonorthogonality. The optical nonorthogonality leads to critical transverse pumping effect, thus transverse light shift, and transverse effective magnetic noise. A direct correlation between the optical nonorthogonality and the electronic spin transverse relaxation rate is found, and a method for suppression of the optical nonorthogonality is proposed accordingly. Finally, the optical nonorthogonal noise is suppressed by 3.1 dB. Besides, an increase of 5.2 dB in the scale factor is achieved. With the combined effect of noise suppression and scale factor enhancement, the resulting inertial rotation sensitivity of $2.4 \times 10^{-8}$ rad/s/Hz $^{1/2}$ in the frequency range from 1 to 3 Hz is among the most sensitive comagnetometers, which opens up promising opportunities for new physics measurements, such as the search for ultralight dark matter and the fifth force.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Balanced Light-Assisted Hybrid Spin Exchange Optical Pumping in SERF Comagnetometers
Ultrasensitive SERF comagnetometers have been widely applied in various new physics experiments and show great potential for inertial navigation. However, the spatially non-uniform spin polarization of alkali metal and noble gas atoms results in an effective magnetic field gradient on the order of 100 nT/cm which is much larger than that is produced by the coils and remanence on the magnitude of 1 nT/cm, thereby reducing the suppression ability of the magnetic noise and limiting the scale factor and noise floor of the comagnetometers. In this study, we establish a model of the effective magnetic field gradient caused by uneven spin polarization and analyze the influencing factors. Our results indicate that optimizing the density ratio of hybird alkali metal atoms can suppress the effective magnetic field gradient. Nevertheless, the available pump light power imposes a limitation on the density ratio. To further address this issue, we propose a balanced light-assisted hybrid spin exchange optical pumping method. Our experimental results confirm the effectiveness of the mentioned approach, with 67% suppression of the nuclear transverse relaxation rate and a nearly 3-fold increase in the scale factor. Furthermore, the optimal density ratio in experimental applications can be reduced from 200 to below 80, thereby overcoming the limitation of laser power in SERF comagnetometers and providing the possibility for wider applications. Finally, the suppression factor of magnetic noise is enhanced by 89% by optimizing the density ratio and the balanced light-assisted hybrid spin exchange optical pumping method. This research sheds light on the fundamental physics experiments and potential for inertial navigation.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Balanced Light-Assisted Hybrid Spin Exchange Optical Pumping in SERF Comagnetometers
Ultrasensitive SERF comagnetometers have been widely applied in various new physics experiments and show great potential for inertial navigation. However, the spatially non-uniform spin polarization of alkali metal and noble gas atoms results in an effective magnetic field gradient on the order of 100 nT/cm which is much larger than that is produced by the coils and remanence on the magnitude of 1 nT/cm, thereby reducing the suppression ability of the magnetic noise and limiting the scale factor and noise floor of the comagnetometers. In this study, we establish a model of the effective magnetic field gradient caused by uneven spin polarization and analyze the influencing factors. Our results indicate that optimizing the density ratio of hybird alkali metal atoms can suppress the effective magnetic field gradient. Nevertheless, the available pump light power imposes a limitation on the density ratio. To further address this issue, we propose a balanced light-assisted hybrid spin exchange optical pumping method. Our experimental results confirm the effectiveness of the mentioned approach, with 67% suppression of the nuclear transverse relaxation rate and a nearly 3-fold increase in the scale factor. Furthermore, the optimal density ratio in experimental applications can be reduced from 200 to below 80, thereby overcoming the limitation of laser power in SERF comagnetometers and providing the possibility for wider applications. Finally, the suppression factor of magnetic noise is enhanced by 89% by optimizing the density ratio and the balanced light-assisted hybrid spin exchange optical pumping method. This research sheds light on the fundamental physics experiments and potential for inertial navigation.
- 26 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Investigation on the Effects of Microvibration on the Atomic Comagnetometer
Precision measurements utilizing atomic spins are widely used in fundamental physics research, inertial sensing, biomagnetism, and the generation of standard quantities. These precision measurements based on quantum sensors have long been disturbed by micro-vibration. In this work, we study the influence of micro-vibration on spin ensembles and perform the experiment on atomic comagnetometer for the first time, which is a powerful tool for search for dark matter and new force, as well as inertial navigation. The model of the effects of micro-vibration on the atomic comagnetometer is established, which considers the transfer characteristics of micro-vibration and the response characteristics of the atomic spin ensembles to the vibration. Moreover, we develop a vibration isolation system, which is a combination of air-floating passive vibration isolators and active feedback systems, to suppress the influence of micro-vibration. Based on the established model and the vibration isolator, we achieve an ultrahigh sensitive comagnetometer, which is among the most sensitive comagnetometer. This work is of wide interest in precision measurement based on quantum sensors and could pave the way for the design of combined vibration isolation systems for such experiments to further improve the sensitivity.
- 26 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Investigation on the Effects of Microvibration on the Atomic Comagnetometer
Precision measurements utilizing atomic spins are widely used in fundamental physics research, inertial sensing, biomagnetism, and the generation of standard quantities. These precision measurements based on quantum sensors have long been disturbed by micro-vibration. In this work, we study the influence of micro-vibration on spin ensembles and perform the experiment on atomic comagnetometer for the first time, which is a powerful tool for search for dark matter and new force, as well as inertial navigation. The model of the effects of micro-vibration on the atomic comagnetometer is established, which considers the transfer characteristics of micro-vibration and the response characteristics of the atomic spin ensembles to the vibration. Moreover, we develop a vibration isolation system, which is a combination of air-floating passive vibration isolators and active feedback systems, to suppress the influence of micro-vibration. Based on the established model and the vibration isolator, we achieve an ultrahigh sensitive comagnetometer, which is among the most sensitive comagnetometer. This work is of wide interest in precision measurement based on quantum sensors and could pave the way for the design of combined vibration isolation systems for such experiments to further improve the sensitivity.
- 15 July 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (15) , 28067-28078
Spin polarization characteristics of hybrid optically pumped comagnetometers with different density ratios
We investigate the effects of the density ratio of K-Rb hybrid cells on the alkali metal-noble gas comagnetometers. Bloch equations simplified with the density ratio and average-pumping-rate model are presented for numerical simulation, which simplifies equations of complete hybrid spin ensemble and problem of polarization gradient. The spin polarizations of electron and nucleon, total electronic relaxation rates, and the spin-exchange efficiencies are measured with cells of different density ratios. The results are in good agreement with our equivalent model. Based on our theoretical analysis, the K-Rb-21Ne comagnetometer achieves maximum output signal by optimizing the combination of density ratio and optical power density. The density ratio is critical to the homogeneity of spin polarization and efficiency of hyperpolarization. The method in this work finds a way to optimize the sensitivity of comagnetometers, which is significant for angular-rotation sensors and new physics research.
- 15 July 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (15) , 28067-28078
Spin polarization characteristics of hybrid optically pumped comagnetometers with different density ratios
We investigate the effects of the density ratio of K-Rb hybrid cells on the alkali metal-noble gas comagnetometers. Bloch equations simplified with the density ratio and average-pumping-rate model are presented for numerical simulation, which simplifies equations of complete hybrid spin ensemble and problem of polarization gradient. The spin polarizations of electron and nucleon, total electronic relaxation rates, and the spin-exchange efficiencies are measured with cells of different density ratios. The results are in good agreement with our equivalent model. Based on our theoretical analysis, the K-Rb-21Ne comagnetometer achieves maximum output signal by optimizing the combination of density ratio and optical power density. The density ratio is critical to the homogeneity of spin polarization and efficiency of hyperpolarization. The method in this work finds a way to optimize the sensitivity of comagnetometers, which is significant for angular-rotation sensors and new physics research.
- 21 June 2022
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 55 (35) , 355106
Design of real time magnetic field compensation system based on fuzzy PI control algorithm for comagnetometer
Alkali-metal-noble-gas comagnetometers operating in the spin exchange relaxation free regime have been widely used in frontier science research and navigation technology. Under normal circumstances, the comagnetometer operates at the compensation point so that any interfering external magnetic field is tracked and suppressed by the nuclear spin. This in turn can greatly diminish the comagnetometer’s sensitivity to the magnetic field; however, its sensitivity to rotations and to anomalous fields is still maintained. The compensation point is typically adjusted manually, which leads to low accuracy and compensation speed, in addition to only allowing short-term magnetic field stability. In order to account for these problems, we designed a three-axis magnetic field compensation system in real time based on LabVIEW, and employed it to a K−Rb − 21 Ne comagnetometer. Our study shows that by using a fuzzy proportional-integral (PI) controller, the compensation point can be tracked in real time and with higher precision when compared with manually adjusted methods, therefore improving the magnetic field stability and sensitivity of the comagnetometer.
- 21 June 2022
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 55 (35) , 355106
Design of real time magnetic field compensation system based on fuzzy PI control algorithm for comagnetometer
Alkali-metal-noble-gas comagnetometers operating in the spin exchange relaxation free regime have been widely used in frontier science research and navigation technology. Under normal circumstances, the comagnetometer operates at the compensation point so that any interfering external magnetic field is tracked and suppressed by the nuclear spin. This in turn can greatly diminish the comagnetometer’s sensitivity to the magnetic field; however, its sensitivity to rotations and to anomalous fields is still maintained. The compensation point is typically adjusted manually, which leads to low accuracy and compensation speed, in addition to only allowing short-term magnetic field stability. In order to account for these problems, we designed a three-axis magnetic field compensation system in real time based on LabVIEW, and employed it to a K−Rb − 21 Ne comagnetometer. Our study shows that by using a fuzzy proportional-integral (PI) controller, the compensation point can be tracked in real time and with higher precision when compared with manually adjusted methods, therefore improving the magnetic field stability and sensitivity of the comagnetometer.
- 3 February 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (5) , 1133-1138
Pulsed light power stabilization of a semiconductor laser using a mixed analog-digital method with an acousto-optic modulator
Diffraction beams produced by an acousto-optic modulator are widely used in various optical experiments, some of which need to modulate the radio-frequency drive signal to change the diffraction beams from continuous light to pulsed light. The generation of such pulsed light is open-loop, and long-term stability of the power is disregarded. In this paper, we introduce a method to suppress the pulsed light power drift of a semiconductor laser. By using the servo system, the low frequency power drift of 1–60 kHz pulsed light can be suppressed. This pulsed light power stabilization method can be applied to optical rotation detection and pulse pumping.
- 3 February 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (5) , 1133-1138
Pulsed light power stabilization of a semiconductor laser using a mixed analog-digital method with an acousto-optic modulator
Diffraction beams produced by an acousto-optic modulator are widely used in various optical experiments, some of which need to modulate the radio-frequency drive signal to change the diffraction beams from continuous light to pulsed light. The generation of such pulsed light is open-loop, and long-term stability of the power is disregarded. In this paper, we introduce a method to suppress the pulsed light power drift of a semiconductor laser. By using the servo system, the low frequency power drift of 1–60 kHz pulsed light can be suppressed. This pulsed light power stabilization method can be applied to optical rotation detection and pulse pumping.
- Open Access
- 7 May 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (9) , 3255
Far Off-Resonance Laser Frequency Stabilization Technology
In atomic physics experiments, a frequency-stabilized or ‘locked’ laser source is commonly required. Many established techniques are available for locking close to an atomic resonance. However, in many instances, such as atomic magnetometer and magic wavelength optical lattices in ultra-cold atoms, it is desirable to lock the frequency of the laser far away from the resonance. This review presents several far off-resonance laser frequency stabilization methods, by which the frequency of the probe beam can be locked on the detuning as far as several tens of gigahertz (GHz) away from atomic resonance line, and discusses existing challenges and possible future directions in this field.
- 7 May 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (9) , 3255
Open AccessFar Off-Resonance Laser Frequency Stabilization Technology
In atomic physics experiments, a frequency-stabilized or ‘locked’ laser source is commonly required. Many established techniques are available for locking close to an atomic resonance. However, in many instances, such as atomic magnetometer and magic wavelength optical lattices in ultra-cold atoms, it is desirable to lock the frequency of the laser far away from the resonance. This review presents several far off-resonance laser frequency stabilization methods, by which the frequency of the probe beam can be locked on the detuning as far as several tens of gigahertz (GHz) away from atomic resonance line, and discusses existing challenges and possible future directions in this field.