Dinghui Gong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dinghui Gong has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Kai Wei
Beihang University
7 shared publications - Xiaofei Huang
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
7 shared publications - Wei Quan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
6 shared publications - Xing Heng
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
5 shared publications - Chang Liu
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
4 shared publications - Di Gong
Hangzhou Institute of Extremely-Weak Magnetic Field Major National Science and Technology Infrastructure, Hangzhou, China
4 shared publications
Latest Publications
- 24 August 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (8)
In situ decoupling of pump-induced spin polarization noise in atomic spin sensors
In atomic spin sensors based on optical pumping, pump beam instabilities can drive atomic spin polarization fluctuations, referred to here as pump-induced spin polarization noise, which may limit sensitivity and long-term stability. Because the local pump field inside the cell can differ from that inferred from external optical diagnostics, it remains difficult to directly quantify the actual in situ spin polarization noise and to evaluate and suppress its contribution to the sensor noise floor. Here, we propose an in situ decoupling method based on spin dynamics, in which a large longitudinal detuning field suppresses magnetic field and rotation responses, while a transverse projection field converts pump-induced fluctuations in longitudinal spin polarization into a measurable transverse spin signal. Demonstrated in a K-Rb-21Ne spin exchange relaxation free (SERF) comagnetometer, the proposed method suppresses the magnetic-field response by approximately 180-fold and enhances the pump-power-noise response by approximately 380-fold, thereby enabling effective separation and evaluation of pump-induced spin polarization noise. The method employs the atomic ensemble as an in situ probe of the spin dynamic response to the local pump optical field. It enables quantitative identification of pump fluctuation associated noise and direct evaluation of optical field stability under actual operating conditions, thereby providing an experimental basis for optical field stabilization and noise suppression assessment in SERF comagnetometers and related alkali atomic spin sensors.
- 24 August 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (8)
In situ decoupling of pump-induced spin polarization noise in atomic spin sensors
In atomic spin sensors based on optical pumping, pump beam instabilities can drive atomic spin polarization fluctuations, referred to here as pump-induced spin polarization noise, which may limit sensitivity and long-term stability. Because the local pump field inside the cell can differ from that inferred from external optical diagnostics, it remains difficult to directly quantify the actual in situ spin polarization noise and to evaluate and suppress its contribution to the sensor noise floor. Here, we propose an in situ decoupling method based on spin dynamics, in which a large longitudinal detuning field suppresses magnetic field and rotation responses, while a transverse projection field converts pump-induced fluctuations in longitudinal spin polarization into a measurable transverse spin signal. Demonstrated in a K-Rb-21Ne spin exchange relaxation free (SERF) comagnetometer, the proposed method suppresses the magnetic-field response by approximately 180-fold and enhances the pump-power-noise response by approximately 380-fold, thereby enabling effective separation and evaluation of pump-induced spin polarization noise. The method employs the atomic ensemble as an in situ probe of the spin dynamic response to the local pump optical field. It enables quantitative identification of pump fluctuation associated noise and direct evaluation of optical field stability under actual operating conditions, thereby providing an experimental basis for optical field stabilization and noise suppression assessment in SERF comagnetometers and related alkali atomic spin sensors.
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
Identification and Analysis of Thermal–Magnetic Coupling Noise in SERF Comagnetometer
The ultrahigh sensitivity of spin-exchange relaxation-free (SERF) magnetometers and comagnetometers plays a crucial role in tests of fundamental physics, biomagnetic measurement, and quantum navigation. The high atomic number density is essential for achieving the SERF regime, making the heating system an indispensable component. However, thermal-magnetic coupling noise generated by the heating system represents a primary source of perturbation for precision measurement based on thermal atomic ensemble. We identify the main sources of thermal-magnetic coupling noise based on a K-Rb-21Ne SERF comagnetometer. By optimizing the operating mode of the heating system, the low-frequency noise at 0.5 Hz is improved by approximately one order of magnitude, thereby enhancing the low-frequency sensitivity of the SERF comagnetometer. Our research advances the long-term stability of atomic sensors and supports their application in probing new physics beyond the Standard Model in the low-energy regime.
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
Identification and Analysis of Thermal–Magnetic Coupling Noise in SERF Comagnetometer
The ultrahigh sensitivity of spin-exchange relaxation-free (SERF) magnetometers and comagnetometers plays a crucial role in tests of fundamental physics, biomagnetic measurement, and quantum navigation. The high atomic number density is essential for achieving the SERF regime, making the heating system an indispensable component. However, thermal-magnetic coupling noise generated by the heating system represents a primary source of perturbation for precision measurement based on thermal atomic ensemble. We identify the main sources of thermal-magnetic coupling noise based on a K-Rb-21Ne SERF comagnetometer. By optimizing the operating mode of the heating system, the low-frequency noise at 0.5 Hz is improved by approximately one order of magnitude, thereby enhancing the low-frequency sensitivity of the SERF comagnetometer. Our research advances the long-term stability of atomic sensors and supports their application in probing new physics beyond the Standard Model in the low-energy regime.
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
In Situ Suppression of Thermal–Magnetic Coupling Noise in Atomic Sensors
Spin-based sensors, such as magnetometers and comagnetometers, require precise control of thermal conditions and magnetic fields to achieve optimal performance. Thermal-magnetic coupling noise, induced by heating systems, is one of the limiting factors for sensitivity improvement. In this paper, the in-situ suppression method is proposed to eliminate thermal-magnetic coupling noise by employing the double-layer heater with dynamically adjustable current ratios. The in-situ method is verified across two distinct systems, including commercial magnetometer and the self-developed comagnetometer. For magnetometer system, the heating-induced magnetic interferences of the double-layer heater along three directions have been decreased over 2 orders compared to a conventional heater. Similarly, the total magnetic flux density has been suppressed by more than 78%. Furthermore, the thermal-magnetic coupling noise in K-Rb-21Ne comagnetometer equipped with the double-layer heater is in-situ suppressed to 6.54×10-9 °/s/Hz1/2 (0.01 fT/ Hz1/2) at 1 Hz, achieving a noise reduction of 22 dB compared to ex-situ method and 24 dB suppression relative to a conventional heater. Besides, the double-layer heater ensures a uniform and stable thermal field across the vapor cell, with a temperature variance less than 0.65 °C and a temperature fluctuation 65% lower than a conventional heater. This work advances ultra-sensitive quantum sensors by providing an effective method to in-situ suppress thermal-magnetic coupling noise.
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
In Situ Suppression of Thermal–Magnetic Coupling Noise in Atomic Sensors
Spin-based sensors, such as magnetometers and comagnetometers, require precise control of thermal conditions and magnetic fields to achieve optimal performance. Thermal-magnetic coupling noise, induced by heating systems, is one of the limiting factors for sensitivity improvement. In this paper, the in-situ suppression method is proposed to eliminate thermal-magnetic coupling noise by employing the double-layer heater with dynamically adjustable current ratios. The in-situ method is verified across two distinct systems, including commercial magnetometer and the self-developed comagnetometer. For magnetometer system, the heating-induced magnetic interferences of the double-layer heater along three directions have been decreased over 2 orders compared to a conventional heater. Similarly, the total magnetic flux density has been suppressed by more than 78%. Furthermore, the thermal-magnetic coupling noise in K-Rb-21Ne comagnetometer equipped with the double-layer heater is in-situ suppressed to 6.54×10-9 °/s/Hz1/2 (0.01 fT/ Hz1/2) at 1 Hz, achieving a noise reduction of 22 dB compared to ex-situ method and 24 dB suppression relative to a conventional heater. Besides, the double-layer heater ensures a uniform and stable thermal field across the vapor cell, with a temperature variance less than 0.65 °C and a temperature fluctuation 65% lower than a conventional heater. This work advances ultra-sensitive quantum sensors by providing an effective method to in-situ suppress thermal-magnetic coupling noise.
- Open Access
- 12 November 2025
- Published by Elsevier in Cell Reports Physical Science
- Vol. 6 (11)
Dynamically polarized atomic comagnetometer
- 12 November 2025
- Published by Elsevier in Cell Reports Physical Science
- Vol. 6 (11)
Open AccessDynamically polarized atomic comagnetometer
- 30 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Decoupling Method of Triaxial Magnetic Field Compensation and Multiparameter Measurement in Comagnetometers
Spin exchange relaxation free (SERF) comagnetometers possess considerable potential for applications in fundamental physics research and inertial navigation. Operating comagnetometers at the magnetic field compensation point and performing multi-parameter measurement are fundamental to reducing the magnetic noise and maintaining high performance. However, the crosstalk among the triaxial magnetic fields diminishes the effectiveness and accuracy of magnetic field compensation and multi-parameter measurement. To address this limitation, we propose a novel method for in-situ rapid and accurate magnetic field compensation and multi-parameter measurement. The decoupling of the triaxial magnetic fields, achieved experimentally through first-order and second-order approximations based on the modulation dynamics of coupled electronic-nuclear spins, enables the direct determination of the magnetic field compensation point. Additionally, the method facilitates the derivation of both the scale factor and the electronic spin relaxation rate. The proposed method addresses the issue of triaxial magnetic field coupling, enhancing the accuracy and efficiency of magnetic compensation and multi-parameter measurement. The proposed method saves more than 70compared to the non-decoupled method, maintaining magnetic field compensation accuracy within 0.2 nT. It demonstrates promising potential for precise magnetic field manipulation and real-time closed-loop control of comagnetometers.
- 30 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Decoupling Method of Triaxial Magnetic Field Compensation and Multiparameter Measurement in Comagnetometers
Spin exchange relaxation free (SERF) comagnetometers possess considerable potential for applications in fundamental physics research and inertial navigation. Operating comagnetometers at the magnetic field compensation point and performing multi-parameter measurement are fundamental to reducing the magnetic noise and maintaining high performance. However, the crosstalk among the triaxial magnetic fields diminishes the effectiveness and accuracy of magnetic field compensation and multi-parameter measurement. To address this limitation, we propose a novel method for in-situ rapid and accurate magnetic field compensation and multi-parameter measurement. The decoupling of the triaxial magnetic fields, achieved experimentally through first-order and second-order approximations based on the modulation dynamics of coupled electronic-nuclear spins, enables the direct determination of the magnetic field compensation point. Additionally, the method facilitates the derivation of both the scale factor and the electronic spin relaxation rate. The proposed method addresses the issue of triaxial magnetic field coupling, enhancing the accuracy and efficiency of magnetic compensation and multi-parameter measurement. The proposed method saves more than 70compared to the non-decoupled method, maintaining magnetic field compensation accuracy within 0.2 nT. It demonstrates promising potential for precise magnetic field manipulation and real-time closed-loop control of comagnetometers.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Analysis and Suppression for Critical Optical Nonorthogonal Noise in SERF Comagnetometers
Ultrasensitive atomic comagnetometers have proven to be valuable tools for precise measurement and search for new physics. Besides, comagnetometers have potential for inertial navigation and quantum information. Despite their great potential, sensitivity improvement has been limited by different types of noise. To address this issue, the sources and magnitudes of noises are comprehensively analyzed and a suppression method is proposed for the most critical noise source, optical nonorthogonality. The optical nonorthogonality leads to critical transverse pumping effect, thus transverse light shift, and transverse effective magnetic noise. A direct correlation between the optical nonorthogonality and the electronic spin transverse relaxation rate is found, and a method for suppression of the optical nonorthogonality is proposed accordingly. Finally, the optical nonorthogonal noise is suppressed by 3.1 dB. Besides, an increase of 5.2 dB in the scale factor is achieved. With the combined effect of noise suppression and scale factor enhancement, the resulting inertial rotation sensitivity of $2.4 \times 10^{-8}$ rad/s/Hz $^{1/2}$ in the frequency range from 1 to 3 Hz is among the most sensitive comagnetometers, which opens up promising opportunities for new physics measurements, such as the search for ultralight dark matter and the fifth force.
- 8 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Analysis and Suppression for Critical Optical Nonorthogonal Noise in SERF Comagnetometers
Ultrasensitive atomic comagnetometers have proven to be valuable tools for precise measurement and search for new physics. Besides, comagnetometers have potential for inertial navigation and quantum information. Despite their great potential, sensitivity improvement has been limited by different types of noise. To address this issue, the sources and magnitudes of noises are comprehensively analyzed and a suppression method is proposed for the most critical noise source, optical nonorthogonality. The optical nonorthogonality leads to critical transverse pumping effect, thus transverse light shift, and transverse effective magnetic noise. A direct correlation between the optical nonorthogonality and the electronic spin transverse relaxation rate is found, and a method for suppression of the optical nonorthogonality is proposed accordingly. Finally, the optical nonorthogonal noise is suppressed by 3.1 dB. Besides, an increase of 5.2 dB in the scale factor is achieved. With the combined effect of noise suppression and scale factor enhancement, the resulting inertial rotation sensitivity of $2.4 \times 10^{-8}$ rad/s/Hz $^{1/2}$ in the frequency range from 1 to 3 Hz is among the most sensitive comagnetometers, which opens up promising opportunities for new physics measurements, such as the search for ultralight dark matter and the fifth force.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Balanced Light-Assisted Hybrid Spin Exchange Optical Pumping in SERF Comagnetometers
Ultrasensitive SERF comagnetometers have been widely applied in various new physics experiments and show great potential for inertial navigation. However, the spatially non-uniform spin polarization of alkali metal and noble gas atoms results in an effective magnetic field gradient on the order of 100 nT/cm which is much larger than that is produced by the coils and remanence on the magnitude of 1 nT/cm, thereby reducing the suppression ability of the magnetic noise and limiting the scale factor and noise floor of the comagnetometers. In this study, we establish a model of the effective magnetic field gradient caused by uneven spin polarization and analyze the influencing factors. Our results indicate that optimizing the density ratio of hybird alkali metal atoms can suppress the effective magnetic field gradient. Nevertheless, the available pump light power imposes a limitation on the density ratio. To further address this issue, we propose a balanced light-assisted hybrid spin exchange optical pumping method. Our experimental results confirm the effectiveness of the mentioned approach, with 67% suppression of the nuclear transverse relaxation rate and a nearly 3-fold increase in the scale factor. Furthermore, the optimal density ratio in experimental applications can be reduced from 200 to below 80, thereby overcoming the limitation of laser power in SERF comagnetometers and providing the possibility for wider applications. Finally, the suppression factor of magnetic noise is enhanced by 89% by optimizing the density ratio and the balanced light-assisted hybrid spin exchange optical pumping method. This research sheds light on the fundamental physics experiments and potential for inertial navigation.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Balanced Light-Assisted Hybrid Spin Exchange Optical Pumping in SERF Comagnetometers
Ultrasensitive SERF comagnetometers have been widely applied in various new physics experiments and show great potential for inertial navigation. However, the spatially non-uniform spin polarization of alkali metal and noble gas atoms results in an effective magnetic field gradient on the order of 100 nT/cm which is much larger than that is produced by the coils and remanence on the magnitude of 1 nT/cm, thereby reducing the suppression ability of the magnetic noise and limiting the scale factor and noise floor of the comagnetometers. In this study, we establish a model of the effective magnetic field gradient caused by uneven spin polarization and analyze the influencing factors. Our results indicate that optimizing the density ratio of hybird alkali metal atoms can suppress the effective magnetic field gradient. Nevertheless, the available pump light power imposes a limitation on the density ratio. To further address this issue, we propose a balanced light-assisted hybrid spin exchange optical pumping method. Our experimental results confirm the effectiveness of the mentioned approach, with 67% suppression of the nuclear transverse relaxation rate and a nearly 3-fold increase in the scale factor. Furthermore, the optimal density ratio in experimental applications can be reduced from 200 to below 80, thereby overcoming the limitation of laser power in SERF comagnetometers and providing the possibility for wider applications. Finally, the suppression factor of magnetic noise is enhanced by 89% by optimizing the density ratio and the balanced light-assisted hybrid spin exchange optical pumping method. This research sheds light on the fundamental physics experiments and potential for inertial navigation.