NCNam Hyun Cho

Nam Hyun Cho

*This is an algorithmically generated author record based on publicly available information.

Nam Hyun Cho has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sound-Driven Motion of Human Cochlear Structures Depends on Organ of Corti Integrity

    by Paul Secchia, Christopher I. McHugh, Nam Hyun Cho, Aleksandrs Zosuls, Andrew Tubelli, Sunil Puria, Hideko Heidi Nakajima

    Optical coherence tomography (OCT) was used to image and measure the passive sound-driven displacements of cochlear structures in situ through the intact round window membrane of fresh human cadaveric specimens at 12 to 30 hours postmortem. We find that the anatomical integrity of the organ of Corti (OoC) affects cochlear structural motion. OoC with high integrity (erect with supporting cells) have small osseous spiral lamina (OSL) motion. Conversely, OoC with low integrity (flattened without supporting cells) have large OSL motion. For the ratio of motion between the basilar membrane (BM) and OSL (BM/OSL), OoC with high integrity has large BM/OSL motion while a cochlear partition without OoC has small BM/OSL motion. Furthermore, the high-integrity OoC has reticular lamina surface motion that is lower than the BM, whereas low-integrity OoC has similar reticular lamina and BM motion. This relationship between OoC anatomical integrity and cochlear structural motion will have consequential effects on sound transduction. Statement of Significance: Acoustic vibrations are transformed into neural signals within the cochlea, the mammalian organ of hearing. Our understanding of cochlear mechanics has been limited to laboratory animals, whose cochleae have significant anatomical and functional differences from humans. To bridge this gap, we imaged and recorded the motion of cochlear structures in intact human cadaveric cochlear specimens without disturbing the interior of the cochlea. We determined how the anatomical integrity of the Organ of Corti (that contains structures for sound transduction) affects cochlear structural motion.

  • Open Access

    Anatomical integrity of the human cochlea estimated with optical coherence tomography for future clinical application

    by Paul Secchia, Christopher I McHugh, Nam Hyun Cho, Jennifer T O'MAlley, MengYu Zhu, Anbuselvan Dharmarajan, Aleksandrs Zosuls, Jingxin Jessica Feng, Yew Song Cheng, Sunil Puria, et al.

    The human cochlea is encased within the otic capsule, the densest bone in the body, posing significant challenges for anatomical imaging of cochlear structures. Because of difficult access and fragility of cochlear structures, our understanding of intracochlear anatomy has historically relied on postmortem histology. We thus have a limited understanding of human cochlear anatomy in its native, unfixed state. Clinical diagnostics for hearing loss, such as audiometry and otoacoustic emissions, offer functional assessments but fail to elucidate the often diverse underlying structural pathologies with any degree of precision. To address the critical need for assessing the human cochlear anatomy and associated pathologies without the risk of traumatizing cochlear structures, we imaged fresh cochleae in situ soon after death through the intact round window membrane with Optical Coherence Tomography (OCT) without inserting instruments inside or opening the cochlea. Micron-resolution OCT cross-sectional images of the human intracochlear structures were acquired and compared with corresponding histology systematically to aid in the identification of fine structural features and possible pathologies. With OCT imaging, we observed varied anatomy of the organ of Corti, and developed a cochlear ″integrity″ rating system to differentiate healthy appearing cochleae from various pathological states. These results demonstrate the capability of OCT to non-traumatically visualize cochlear integrity, highlighting its potential as a diagnostic tool. This work shows promise in translating the ability to determine the likelihood of existing or lack of hair cells and supporting cells in live patients, which would enable appropriate targeted treatments.

  • Open Access

    Development of the Rubber Removal Primer to Reduce Pavement Damage for Removal of Rubber Deposits in Runways

    by Young-Ung Kim, Kwang-Ho You, Nam-Hyun Cho

    Development of the Rubber Removal Primer to Reduce Pavement Damage for Removal of Rubber Deposits in Runways Rubber removal primer;Rubber deposit;Rubber removal;Pavement surface damage;High-pressure waterblast; Rubber deposited during aircraft landing is known as the main cause of reducing surface friction force on wet surfaces. Thus, rubber deposits are removed at regular intervals for sae airplane landing. The high-pressure waterblast method, widely used for the removal of rubber deposits, is regarded as the main cause for the loss of surface material because in this method, water hits the surface directly at a high pressure. In this study, a rubber removal primer is developed to reduce surface damage by lowering the pressure of waterblast relatively during the removal of rubber deposits such that the deposits are removed efficiently even with a lower water pressure. To achieve this, basic materials appropriate for the primer were selected and their performance, penetration rate, and site applicability were evaluated. Based on the evaluations, the proportion of additive required for improving the performance of the basic materials was first determined. Then, the optimum mix ratio was derived through the evaluation of the effect on pavements, and the development of the rubber removal primer was completed.


  • Pulse Analyzing System Using Optical Coherence Tomography for Oriental Medical Application

    by Unsang Jung, Mansik Jeon, Changho Lee, Namhyun Cho, Hyosang Jeong, Changsu Na, Jeehyun Kim

    In oriental medicine, the pulse wave of a radial artery is a critical diagnosis factor. An oriental doctor puts a finger on the radial artery to sense the pulse wave of a radial artery. The pulse wave plays an important role because its shape, pressure, and duration determine the pathological status of a patient. Chongumaekbeop, which is a traditional technique for measuring the pulse by using a finger, is sometimes believed to be not reproducible due to the subjective judgment of the measurement location and pulse signal, so we performed a clinical experiment with a developed diagnosis equipment to produce quantitative and reproducible results. In this study, we measured the pulse wave of the radial artery and quantified the speed, intensity, and power of the pulse wave using optical coherence tomography (OCT). We confirmed the applicability of the developed system through an analysis of the pulse wave. We used two OCT systems whose measurement parameters are different because of the measurement limitation and analysis of vector components of pulse movement. We gathered 25 volunteers, compared and analyzed the experiment results with four oriental medicine doctors' diagnosis. The results showed an agreement of 88% in pulse speed, 64% in pulse intensity, and 72% in pulse power when comparing traditional measurements with the system using OCT. We confirmed the dynamical motion detection through the two-dimensional image to ensure the reproducibility of the developed system. Thus, if the OCT system is applied to pulse measurement systems in oriental medicine, it may partially substitute for traditional measurement methods.