FFFan Feng

Fan Feng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fan Feng has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Closed-Loop Trajectory Tracking Control of a Cable-Driven Continuum Robot With Integrated Draw Tower Grating Sensor Feedback

    by Yongfeng Cao, Fan Feng, Zefeng Liu, Le Xie

    Due to the inherent deformability of continuum robots (CRs), closed-loop control strategies of CRs come with some challenges, including sensor integration within a limited dimension and uncertainties with the CR system. In this paper, to obtain the spatial shape information and tip position of a cable-driven CR, a draw tower grating (DTG) sensor is integrated. A shape sensing algorithm is proposed to reconstruct the shape of the CR based on the relation between the DTG sensor and the CR centerline. Then, with the feedback information of the DTG sensor, a damped least-squares (DLS)-based closed-loop controller is implemented to improve the trajectory tracking performance of the CR. To verify the effectiveness of the proposed scheme, comparative experiments are performed.


  • A Two-Segment Continuum Robot With Piecewise Stiffness for Maxillary Sinus Surgery and Its Decoupling Method

    by Wuzhou Hong, Fan Feng, Le Xie, Guang-Zhong Yang

    With the use of tendon-driven continuum manipulators, it is possible to reach deep-seated small lesions in a constrained anatomical space. This circumvents the difficulties encountered by existing straight endoscopes and surgical instruments, which require direct line of sight access during inspection and operation. However, maintaining adequate stiffness while ensuring smoothness and flexibility during operation for a continuum robot with a small diameter is difficult. In this article, we present the design, modeling, and validation of a new two-segment continuum robot for maxillary sinus surgery. It addresses the coupling effects that can affect the safety and precise operation within the maxillary sinus. To overcome potential distal-to-proximal deviations, a piecewise stiffness structure for the continuum manipulator is proposed. Modified kinematics, based on variable curvature continuum kinematics, is used to resolve motion coupling, and a model of the continuum manipulator with varying stiffness is proposed, with due consideration of tension coupling. Experiments are carried out to validate the proposed design, modeling, and compensation schemes. Results show that the proposed manipulator can flexibly and accurately reach the target positions in the maxillary sinus model. Comparisons of continuum robots with and without the proposed compensation schemes demonstrate the practical value and potential clinical use of the proposed method.


  • Development and experiments of a continuum robotic system for transoral laryngeal surgery

    by Fan Feng, Yuan Zhou, Wuzhou Hong, KeYong Li, Le Xie

    Purpose Currently, self-retaining laryngoscopic surgery is not suitable for some patients, and there are dead zones relating to surgical field exposure and operation. The quality of the surgery can also be affected by the long periods of time required to complete it. Teleoperated continuum robots with flexible joints are expected to solve these issues. However, at the current stage of developing transoral robotic surgery systems, their large size affects the precision of surgical operative actions and there are high development and treatment costs. Methods We fabricated a flexible joint based on selective laser melting technology and designed a shallow neural network-based kinematic modeling approach for a continuum surgical robot. Then, human model and animal experiments were completed by master–slave teleoperation to verify the force capability and dexterity of the robot, respectively. Results As verified by human model and animal experiments, the designed continuum robot was demonstrated to achieve transoral laryngeal surgical field exposure without laryngoscope assistance, with sufficient load capability to finish the biopsy of vocal fold tissue in living animals. Conclusion The designed continuum robotic system allows the biopsy of vocal fold tissue without laryngoscope assistance. Its stiffness and dexterity indicate the system’s potential for applications in the diagnosis and treatment of vocal fold nodules and polyps. The limitations of this robotic system as shown in the experiments were also analyzed.


  • Development and validation of a two‐segment continuum robot for maxillary sinus surgery

    by Wuzhou Hong, Yuan Zhou, Yongfeng Cao, Fan Feng, Zefeng Liu, Keyong Li, Le Xie

    Background: Existing rigid instruments have difficulties in backward inspection and operation. Moreover, the pathway to the maxillary sinus is curved and narrow, resulting in complex and repetitive manual operations. There is a necessity to develop a retro‐flexing robot and achieve path‐following motion.Methods: A continuum robotic system is developed for maxillary sinus surgery (MSS). And the system adopts an anatomical constraint‐based optimization of the follow‐the‐leader strategy to generate a safe control scheme along a given path.Results: The accuracy of the system is evaluated, and the task of reaching deep‐seated targets is performed in a constrained anatomical space. The simulations and experiments of the path‐following motion have validated the feasibility of the proposed method. Furthermore, a preliminary porcine study is performed to assess the capability of instruments.Conclusions: The developed continuum robotic system can meet the requirements of MSS.


  • Open Access

    Design of 3D-Printed Flexible Joints With Presettable Stiffness for Surgical Robots

    by Fan Feng, Wuzhou Hong, Le Xie

    Continuum manipulators have been widely used in minimally invasive surgery due to their high dexterity. However, different surgeries have different stiffness and dexterity requirements. This paper describes a continuum manipulator for robot-assisted surgery. The flexible part is a joint that can be 3D-printed using various materials. The flexible joints made of each material are of the same size but have different stiffness and dexterity. In this way, the appropriate stiffness can be preset by selecting a suitable manufacturing material according to specific surgical needs. Kinematic and static models of the proposed flexible joints were designed. A finite element analysis method was used to calculate the correction factors. We analyzed the workspace and stiffness differences between flexible joints made of different materials quantitatively and qualitatively, respectively. We conducted experiments to verify the accuracy of the static model and the stiffness differences between the flexible joints. Finally, several design variations were introduced, which demonstrate the unique advantages of these flexible joints in the field of surgical robotics.