Shota Masuda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shota Masuda has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Kazuya Minamishima
Office of Radiological Technology, Keio University Hospital, Tokyo, Japan
2 shared publicationsMasahiro Jinzaki
Department of Radiology, Keio University School of Medicine, Tokyo, Japan
2 shared publications- Yoshitake Yamada
Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
2 shared publications Akihisa Yamazaki
Office of Radiological Technology, Keio University Hospital, Tokyo, Japan
1 shared publication- Akihisa Yamazaki
Office of Radiological Technology, Keio University Hospital, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
1 shared publication Akiko Nakahara
Department of Radiology, Tokyo Metropolitan Health and Medical Treatment Corporation Toshima Hospital, 33-1 Sakaecho, Itabashi, Tokyo 173 0015, Japan
1 shared publication
Latest Publications
- 5 February 2022
- Published by Elsevier in European Journal of Radiology
- Vol. 149, 110198
Impact of noise reduction on radiation dose reduction potential of virtual monochromatic spectral images: Comparison of phantom images with conventional 120 kVp images using deep learning image reconstruction and hybrid iterative reconstruction
- 5 February 2022
- Published by Elsevier in European Journal of Radiology
- Vol. 149, 110198
Impact of noise reduction on radiation dose reduction potential of virtual monochromatic spectral images: Comparison of phantom images with conventional 120 kVp images using deep learning image reconstruction and hybrid iterative reconstruction
- 5 January 2021
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 14 (1) , 41-49
Assessment of the image quality of virtual monochromatic spectral computed tomography images: a phantom study considering object contrast, radiation dose, and frequency characteristics
Fast kilovoltage (kVp)-switching technology cannot obtain conventional 120 kVp images; thus, 70 keV virtual monochromatic spectral computed tomography (CT) images (VMSI) are generally used. The contrast-to-noise ratio (CNR) is used to evaluate the image quality of VMSI; however, CNR does not include frequency characteristics. The present study aimed to investigate the evaluation methods of VMSI considering frequency characteristics by comparing the image quality of 70 keV VMSI with that of conventional 120 kVp images. The evaluated object contrasts were 70 and 300 Hounsfield units (HU). Scans used two radiation dose levels: low (LD) and standard (SD). The volume CT dose index of LD and SD was 4.8- and 12 mGy, respectively. Images were reconstructed by filtered back projection, evaluating CNR, noise power spectrum (NPS), task transfer function (TTF), and system performance (SP) function calculated as TTF2/ NPS. The total NPS values (spatial frequency range: 0.2 ~ 0.4 mm−1) of 70 keV VMSI were higher than those of 120 kVp images. The spatial frequency TTF values that reached 10% (f10%) of the 70 keV VMSI changed based on object contrast. For the low-contrast condition, a lower f10% was observed with 70 keV VMSI. The CNR of 70 keV VMSI was comparable to that of 120 kVp images in low- and high-contrast conditions. However, for 70 keV VMSI, SP of low-contrast was low, and SP of high-contrast was high, compared with those of 120 kVp images. This study suggested that only CNR was not sufficient to evaluate the image quality of VMSI; thus, evaluation methods considering frequency characteristics should be used.
- 5 January 2021
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 14 (1) , 41-49
Assessment of the image quality of virtual monochromatic spectral computed tomography images: a phantom study considering object contrast, radiation dose, and frequency characteristics
Fast kilovoltage (kVp)-switching technology cannot obtain conventional 120 kVp images; thus, 70 keV virtual monochromatic spectral computed tomography (CT) images (VMSI) are generally used. The contrast-to-noise ratio (CNR) is used to evaluate the image quality of VMSI; however, CNR does not include frequency characteristics. The present study aimed to investigate the evaluation methods of VMSI considering frequency characteristics by comparing the image quality of 70 keV VMSI with that of conventional 120 kVp images. The evaluated object contrasts were 70 and 300 Hounsfield units (HU). Scans used two radiation dose levels: low (LD) and standard (SD). The volume CT dose index of LD and SD was 4.8- and 12 mGy, respectively. Images were reconstructed by filtered back projection, evaluating CNR, noise power spectrum (NPS), task transfer function (TTF), and system performance (SP) function calculated as TTF2/ NPS. The total NPS values (spatial frequency range: 0.2 ~ 0.4 mm−1) of 70 keV VMSI were higher than those of 120 kVp images. The spatial frequency TTF values that reached 10% (f10%) of the 70 keV VMSI changed based on object contrast. For the low-contrast condition, a lower f10% was observed with 70 keV VMSI. The CNR of 70 keV VMSI was comparable to that of 120 kVp images in low- and high-contrast conditions. However, for 70 keV VMSI, SP of low-contrast was low, and SP of high-contrast was high, compared with those of 120 kVp images. This study suggested that only CNR was not sufficient to evaluate the image quality of VMSI; thus, evaluation methods considering frequency characteristics should be used.
- 1 June 2020
- Published by Elsevier in Physica Medica
- Vol. 74, 47-55
Spatial resolution compensation by adjusting the reconstruction kernels for iterative reconstruction images of computed tomography
- 1 June 2020
- Published by Elsevier in Physica Medica
- Vol. 74, 47-55
Spatial resolution compensation by adjusting the reconstruction kernels for iterative reconstruction images of computed tomography