Asha Prasad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Asha Prasad has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Sundarrajan Asokan
Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
4 shared publications - S. Srivatzen
Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
2 shared publications Suneetha Sebastian
Department of Instrumentation and Applied Physics, DST-INSPIRE Faculty, Indian Institute of Science, Bengaluru, India
2 shared publications- Kavitha Srinivasan
Optoelectronics Research Centre, University of Southampton, Southampton, U.K.
1 shared publication - Shweta Pant
Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
1 shared publication
Latest Publications
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (9) , 14253-14260
L-Cysteine Modified Gold Nanoparticles for Copper (II) Ion Detection Using Etched Fiber Bragg Grating Sensor
A highly sensitive and selective optical detection of copper (II) (Cu 2+ ) concentration in water has been proposed using L-cysteine functionalized gold nanoparticles (AuNPs) using an etched Fiber Bragg grating sensor (eFBG). The eFBG sensor produces a Bragg wavelength shift (ΔλB) in correspondence to the added Cu 2+ concentration. The amino acid L-Cysteine facilitates the formation of core-satellite nanoassemblies of gold in the presence of Cu 2+ . A linear wavelength shift is observed in accordance with the mediating Cu 2+ concentration. The sensor’s detection limit is found to be 1picomolar (pM) which is well within the world health organization (WHO) acceptable limit for safe drinking water and the dynamic range of the sensor lies between 1pM to 100 μM. The sensor is highly sensitive and selective to Cu 2+ with sensitivity of 230 pm 10 -1 M. The sensor has proven its capability as an ideal probe for onsite, real-time measurement of Cu 2+ in drinking water by giving a recovery percentage of >90% in real water sample additional to good reproducibility (standard error< 20 pm), high sensitivity, portability and specificity.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (9) , 14253-14260
L-Cysteine Modified Gold Nanoparticles for Copper (II) Ion Detection Using Etched Fiber Bragg Grating Sensor
A highly sensitive and selective optical detection of copper (II) (Cu 2+ ) concentration in water has been proposed using L-cysteine functionalized gold nanoparticles (AuNPs) using an etched Fiber Bragg grating sensor (eFBG). The eFBG sensor produces a Bragg wavelength shift (ΔλB) in correspondence to the added Cu 2+ concentration. The amino acid L-Cysteine facilitates the formation of core-satellite nanoassemblies of gold in the presence of Cu 2+ . A linear wavelength shift is observed in accordance with the mediating Cu 2+ concentration. The sensor’s detection limit is found to be 1picomolar (pM) which is well within the world health organization (WHO) acceptable limit for safe drinking water and the dynamic range of the sensor lies between 1pM to 100 μM. The sensor is highly sensitive and selective to Cu 2+ with sensitivity of 230 pm 10 -1 M. The sensor has proven its capability as an ideal probe for onsite, real-time measurement of Cu 2+ in drinking water by giving a recovery percentage of >90% in real water sample additional to good reproducibility (standard error< 20 pm), high sensitivity, portability and specificity.
- 10 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (21) , 24106-24113
A Non-Invasive Breast Cancer Detection System Using FBG Thermal Sensor Array: A Feasibility Study
Breast cancer is one of the most challenging health problems in women worldwide. Early detection and regular breast cancer screening can considerably improve the survival rate. Many advanced imaging technologies are currently being used in the detection of breast malignancy. However, these methods are costly, uncomfortable, and time-consuming. Therefore, in this work, a simple and noninvasive thermographic technique, based on a Fiber Bragg Grating (FBG) thermal sensor array, has been developed to detect breast cancer. Breast tissue is simulated using agar gel phantom, and the heaters are embedded inside the phantom in different locations to mimic the tumors. FBG thermal sensor array is employed to acquire the surface temperature distribution of the simulated breast phantom. Also, modeling of the tissue-mimicking phantom and tumor in COMSOL Multiphysics software is carried out to provide a detailed 3D thermal view of the proposed prototype. Both experimental and simulated results are found to be in agreement and display the same trend as expected. Experimental results show that a temperature variation of ≥ 0.3°C is detected at the location of the tumor’s presence, which can be easily picked up by FBG interrogators which have sensitivity of ~ 1 pm, indicating the efficacy of the proposed sensing prototype as a potential screening tool for the diagnosis of breast cancer.
- 10 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (21) , 24106-24113
A Non-Invasive Breast Cancer Detection System Using FBG Thermal Sensor Array: A Feasibility Study
Breast cancer is one of the most challenging health problems in women worldwide. Early detection and regular breast cancer screening can considerably improve the survival rate. Many advanced imaging technologies are currently being used in the detection of breast malignancy. However, these methods are costly, uncomfortable, and time-consuming. Therefore, in this work, a simple and noninvasive thermographic technique, based on a Fiber Bragg Grating (FBG) thermal sensor array, has been developed to detect breast cancer. Breast tissue is simulated using agar gel phantom, and the heaters are embedded inside the phantom in different locations to mimic the tumors. FBG thermal sensor array is employed to acquire the surface temperature distribution of the simulated breast phantom. Also, modeling of the tissue-mimicking phantom and tumor in COMSOL Multiphysics software is carried out to provide a detailed 3D thermal view of the proposed prototype. Both experimental and simulated results are found to be in agreement and display the same trend as expected. Experimental results show that a temperature variation of ≥ 0.3°C is detected at the location of the tumor’s presence, which can be easily picked up by FBG interrogators which have sensitivity of ~ 1 pm, indicating the efficacy of the proposed sensing prototype as a potential screening tool for the diagnosis of breast cancer.
- 19 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (9) , 10695-10702
FBG Tactile Sensor for Surface Thickness and Shape Measurement
In recent years, numerous measurement techniques have been employed to characterize surface textures in the micrometer and nanometer range. Although these techniques have enabled significant advances in surface metrology, larger surface details are not easily measurable with such techniques. We propose a simple and reliable fiber Bragg grating (FBG) based tactile displacement sensor to measure a wide range of displacements that vary from 0.2 μm to 2mm. The device adopts a novel multi-pivot mechanical lever-based amplification mechanism to achieve a wide measurement range. Experimental results show that the sensor can measure both 219nm thick, thin-film coating and 1.22mm glass slide by selecting an appropriate pivot position. Further, the device is employed to identify topographies of three different surfaces of different dimensions. The sensor's optimized configuration demonstrates an excellent displacement sensitivity of 63926pm/mm with a high resolution of 15.64nm. The repeatability of the sensor in this configuration is 2.44%.
- 19 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (9) , 10695-10702
FBG Tactile Sensor for Surface Thickness and Shape Measurement
In recent years, numerous measurement techniques have been employed to characterize surface textures in the micrometer and nanometer range. Although these techniques have enabled significant advances in surface metrology, larger surface details are not easily measurable with such techniques. We propose a simple and reliable fiber Bragg grating (FBG) based tactile displacement sensor to measure a wide range of displacements that vary from 0.2 μm to 2mm. The device adopts a novel multi-pivot mechanical lever-based amplification mechanism to achieve a wide measurement range. Experimental results show that the sensor can measure both 219nm thick, thin-film coating and 1.22mm glass slide by selecting an appropriate pivot position. Further, the device is employed to identify topographies of three different surfaces of different dimensions. The sensor's optimized configuration demonstrates an excellent displacement sensitivity of 63926pm/mm with a high resolution of 15.64nm. The repeatability of the sensor in this configuration is 2.44%.
- 21 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (12) , 6394-6399
Diaphragm-Micro-Stylus-Based Fiber Bragg Grating Tactile Sensor
!We propose a simple and novel circular diaphragm–micro-stylus based single fiber Bragg grating (FBG) tactile sensor for reading Standard English Grade-1 Braille cells. The surface protrusions on the cells are transduced into strain variations on the FBG sensor, bonded along the line of symmetry of the diaphragm, by a free, vertically moving Micro-Stylus (MS). The tension mode of the diaphragm and the mass of the micro-styli are varied to optimize the sensing properties of the system. The maximum sensitivity of 1.786nm/mm is exhibited by the sensor system with the highest mass of the MS (MS-1; 167mg) in the highest tension mode (770με). The repeatability error and resolution of the sensor in the aforementioned configurations are found to be 0.028nm and 559nm respectively. The proposed sensor system displayed good linearity, repeatability, high resolution, and easily adjustable sensitivity in the present scenario.
- 21 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (12) , 6394-6399
Diaphragm-Micro-Stylus-Based Fiber Bragg Grating Tactile Sensor
!We propose a simple and novel circular diaphragm–micro-stylus based single fiber Bragg grating (FBG) tactile sensor for reading Standard English Grade-1 Braille cells. The surface protrusions on the cells are transduced into strain variations on the FBG sensor, bonded along the line of symmetry of the diaphragm, by a free, vertically moving Micro-Stylus (MS). The tension mode of the diaphragm and the mass of the micro-styli are varied to optimize the sensing properties of the system. The maximum sensitivity of 1.786nm/mm is exhibited by the sensor system with the highest mass of the MS (MS-1; 167mg) in the highest tension mode (770με). The repeatability error and resolution of the sensor in the aforementioned configurations are found to be 0.028nm and 559nm respectively. The proposed sensor system displayed good linearity, repeatability, high resolution, and easily adjustable sensitivity in the present scenario.