KSKavitha Srinivasan

Kavitha Srinivasan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kavitha Srinivasan has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Purging and evacuation of hollow-core optical fibres through permeation of helium through the jacket

    by Peter Horak, Kavitha Srinivasan, Thomas W Kelly, Radan Slavík, Natalie V Wheeler

    We demonstrate a novel method to purge the core of long lengths of hollow-core optical fibres where the original gas content is pushed out by helium permeating through the fibre jacket along the full fibre length. Once helium has replaced the gas in the fibre, the fibre ends can be sealed, whereupon the helium is left to permeate back out through the glass, leaving an evacuated fibre. The viability and the limits of this technique are investigated by a numerical analysis whose accuracy is validated by proof-of-principle experiments. The model predicts that the evacuation times of hollow-core fibres of hundreds of metres to kilometres length can be reduced by orders of magnitude compared to traditional methods, from hundreds of days to about one day.


  • Rapid and Efficient Identification of Cd (II) Ions in Water With Functionalized Gold Nanoparticle Coated Etched FBG Sensors

    by Debojyoti Mondal, B. S. Kavitha, N. Vajresh Kumar, S. Asokan

    Cadmium (Cd (II)) is one of the important contributors to global water pollution, due to its prolonged biological half-life and carcinogenic nature. This study presents a selective and sensitive optical sensor based on an etched Fiber Bragg Grating (e-FBG) sensor coated with Mercaptosuccinic Acid (MSA) functionalized gold nanoparticles for the rapid identification of Cd (II). Carboxylic groups present in MSA self-assembles on gold nanoparticles to provide the selective binding sites for Cd (II), thereby inducing a Bragg wavelength shift (Δλ B ) with corresponding changes in Cd (II) concentrations. The present study demonstrates a linear dependency of Δλ B with the molar concentration of Cd (II), with a limit of detection (LOD) of 10 × 10 -15 Molar (fM, 0.00000112 ppb) and a dynamic range up to 100 × 10 -9 Molar (nM, 11.24 ppb). These values align comfortably within the World health organization (WHO) limits (26 × 10 -9 M or 3 ppb) for drinking water. The specificity of the sensor has been ascertained in the presence of other interfering metal ions like lead (Pb (II)), mercury (Hg (II)), arsenic (As (III)), sodium (Na (I)) and chromium (Cr (VI)). Further, the accuracy of the sensor (> 93 %), has been cross verified with Inductively Coupled Plasma Mass Spectroscopy (ICPMS). A good recovery percentage of > 95% obtained in drinking water samples, further highlights the sensors efficacy for practical applications. The linear response, good reproducibility (standard error ≤ 15 pm), portability and real-time monitoring capability, make the present sensor a promising candidate for on-site monitoring of Cd (II) in drinking water samples.


  • Functionalized Silver Nano Particle Coated e-FBG Sensor for Specific and Rapid Detection of Chromium in Drinking Water

    by Debojyoti Mondal, B. S. Kavitha, N. Vajresh Kumar, S. Asokan

    Hexavalent Chromium ( Cr (VI) ), a widely used material in industry has raised alarm due to its genotoxicity and carcinogenic nature. This study focuses on developing an effective optical sensor for determining Cr (VI) in drinking water, based on polyvinyl pyrrolidone (PVP) functionalized silver nanoparticles (AgNp) coated, clad etched Fibre Bragg Grating (e-FBG). The lone pair electrons present in Nitrogen (N) and Oxygen (O) present in PVP contribute towards the specific binding of Cr (VI) on the sensor surface, causing a shift in the Bragg wavelength (ΔλB) with Cr (VI) concentration. A liner relationship is observed in the current study indicates with molar concentration of Cr (VI) , with a detection limit (LOD) of 0.1 pM (0.0000052 ppb) and a working range of 0.1 pm to 100 μM (5.2 ppm), which is within the World Health Organization (WHO) permissible limit of 960 nM (50 ppb) in drinking water. The sensor is observed to be specific in nature when exposed to other interfering ions like arsenic ( AS(II) ), mercury ( Hg (II) ), lead ( Pb (II) ), magnesium ( Mg (II) ), sodium ( Na(I) ) and tri- valent chromium ( Cr (III) ). The sensor’s accuracy has been reconfirmed with Inductively Coupled Plasma Mass Spectroscopy (ICPMS), which showed an accuracy of (> 96%). A good recovery percentage (> 95%) for spiked drinking water samples highlights the sensor’s efficacy in case of real water sample analysis. A portable sensor with real time monitoring ability, combined with good reproducibility (S < 10 pM) and liner response make the present sensor, a potential onsite candidate for Cr (VI) determination in drinking water.


  • L-Cysteine Modified Gold Nanoparticles for Copper (II) Ion Detection Using Etched Fiber Bragg Grating Sensor

    by S. Srivatzen, B. S. Kavitha, Asha Prasad, Sundarrajan Asokan

    A highly sensitive and selective optical detection of copper (II) (Cu 2+ ) concentration in water has been proposed using L-cysteine functionalized gold nanoparticles (AuNPs) using an etched Fiber Bragg grating sensor (eFBG). The eFBG sensor produces a Bragg wavelength shift (ΔλB) in correspondence to the added Cu 2+ concentration. The amino acid L-Cysteine facilitates the formation of core-satellite nanoassemblies of gold in the presence of Cu 2+ . A linear wavelength shift is observed in accordance with the mediating Cu 2+ concentration. The sensor’s detection limit is found to be 1picomolar (pM) which is well within the world health organization (WHO) acceptable limit for safe drinking water and the dynamic range of the sensor lies between 1pM to 100 μM. The sensor is highly sensitive and selective to Cu 2+ with sensitivity of 230 pm 10 -1 M. The sensor has proven its capability as an ideal probe for onsite, real-time measurement of Cu 2+ in drinking water by giving a recovery percentage of >90% in real water sample additional to good reproducibility (standard error< 20 pm), high sensitivity, portability and specificity.


  • A Silver Nanoparticle Modified Etched Fiber Bragg Grating Sensor for Arsenic Detection

    by N. Vajresh Kumar, B. S. Kavitha, S. Asokan

    The global data on arsenic ( As ) contamination in drinking water, and the severity of As exposure, emphasize the utmost need for early and efficient detection of As in water. In this work, we report a quantitative optical detection of As in drinking water using silver nanoparticle (AgNP) functionalized etched-Fiber Bragg Grating (e-FBG) sensor. The selective attachment of As (III) to AgNP is applied here for the sensitive detection of As , which is exemplified as a Bragg wavelength shift (Δλ B ) in the functionalized e-FBG sensor. The detection limit is found to be 10 femtomolar (fM) with dynamic range up to 100 nanomolar (nM), which is less than the World Health Organization (WHO) standards for drinking water (not over 50.5 nM). The e-FBG sensor shows a good reproducibility (standard error < 10pm), specificity and sensitivity (86.13 pm/10 -1 M) to arsenic in real time at ambient conditions. The quantitative As value, with a 94 % recovery in tap water sample, makes the e-FBG sensor better than other methods.


  • Open Access

    Enhanced Optical Sensitivity of Polyvinyl Alcohol–Reduced Graphene Oxide Electrospun Nanofiber Coated Etched Fiber Bragg Grating Sensor for Detection of Myoglobin a Cardiac Biomarker

    by Kavitha B. Srinivasan, Vikram S. Raghavan, Munish Shorie, Priyanka Sabherwal, Sai S Gorthi, Sundarrajan Asokan, Ajay. K. Sood

    Etched fiber Bragg grating (eFBG) sensors have shown to be highly sensitive with the capability of giving accurate real‐time response to a variety of measurands such as pressure, gas, biomolecules, to name a few. These sensors have not shown their mettle as competitive products mainly due to nonreproducibility in results and inefficiency in upscaling for large‐scale production; the main reason being nonuniform and complicated coating procedures. Herein, the enhancement in refractive index (RI) sensitivity (≈4 times) obtained with electrospinning of polyvinyl alcohol–reduced graphene oxide (PVA–rGO) nanofibers onto eFBG sensor using a customized target and a unique sandwich arrangement is demonstrated. The enhancement in RI sensitivity has led to a lower detection limit and increased sensitivity and linear range for a case study using myoglobin (Mb), an early‐stage cardiac biomarker with high reproducible results (standard error ≤±2.3%). rGO embedded PVA nanofiber electrospun onto an eFBG sensor (PVA–rGO sensor) is the first of its kind and has significant importance in developing cost‐effective, label‐free, multianalyte, portable, real‐time, point‐of‐care (POC) kits at ambient conditions.


  • Highly sensitive and Rapid detection of mercury in water using functionalized etched fiber Bragg grating sensors

    by Kavitha B S, Sridevi S, Pandeeswar Makam, Debasis Ghosh, Thimmaiah Govindaraju, Asokan S, A K Sood


  • Etched Fiber Bragg Grating Sensor for Quantification of DNA

    by B. S. Kavitha, N. K. Radhika, Sai Siva Gorthi, S. Asokan

    The detection and quantification of DNA is of critical importance in various molecular biology processes and has applications in fields ranging from forensics to environmental monitoring. Here, the development of a highly sensitive and label-free technique for DNA detection is reported. This paper proposes a reduced graphene oxide (rGO) coated etched Fiber Bragg Grating (eFBG) sensor as a tool for the detection and quantification of dsDNA. The proposed sensor is found to have a limit of detection of 261.87 pg/μl and the sensor response is a linear function of the dsDNA concentration in the range between 1 ng/μl to 50 ng/μl with excellent stability and repeatability. The paper also proposes a technique to quantitatively measure the amount of DNA bound to the sensor and thus, the DNA binding efficacy of the rGO coating on the sensor, utilizing UV spectrometry.