NPNguyen Hai Phong

Nguyen Hai Phong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nguyen Hai Phong has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electrochemical sensing of sildenafil in pharmaceutical formulations using an (S,N)-doped reduced graphene oxide-modified electrode

    by Nguyen Quang Man, Ngo Thi Thanh Xuan, Vo Thi Khanh Ly, Le Van Thanh Son, Le Duc Anh, Le Thi Hong Phong, Nguyen Hai Phong, Pham Khac Lieu, Le Lam Son, Dinh Quang Khieu

    In this work, (S,N)-co-doped reduced graphene oxide ((S,N)-rGO) was successfully synthesized via thermal treatment and thoroughly characterized by X-ray diffraction, high-resolution transmission electron microscopy, elemental mapping, photoluminescence, and Raman spectroscopy, confirming the successful incorporation of nitrogen and sulfur into the graphene framework. The obtained (S,N)-rGO was used to modify a glassy carbon electrode for the electrochemical determination of sildenafil (SDN). The modified electrode exhibited enhanced electrocatalytic activity toward SDN oxidation, providing a well-defined current response. Under optimized conditions, the sensor showed a good linear relationship between peak current and SDN concentration in the range of 0.25–4.98 µM, with a low limit of detection of 0.24 µM and a limit of quantification of 0.78 µM. The proposed sensor demonstrated satisfactory repeatability, reproducibility, and stability, as well as good selectivity in the presence of potential interfering substances. The applicability of the method was validated by the determination of SDN in pharmaceutical samples. The results were in good agreement with those from high-performance liquid chromatography, indicating that the proposed electrochemical method is reliable and suitable for practical analysis.

  • Open Access

    Electrochemical detection of illicit sibutramine adulteration in herbal weight-loss products using an AgNPs-ErGO modified electrode

    by Nguyen Dang Thuy Anh, Vo Thi Cam Le, Huynh Van Chung, Ngo Thi Thanh Xuan, Hoang Thi Minh Nguyet, Pham Thi Thanh Ha, Ha Thuy Trang, Le Hoang Hao, Dao Thi Cam Minh, Nguyen Hai Phong, et al.

    Background and purpose: Sibutramine is a synthetic anti-obesity drug that has been banned or restricted in many countries due to serious cardiovascular risks. However, its illegal adulteration in herbal weight-loss products remains a public health concern. This study aimed to develop a simple, sensitive, and reliable electrochemical method for the determination of sibutramine in herbal weight-loss products using a silver-nanoparticle-electrochemically reduced graphene oxide modified glassy carbon electrode. Experimental approach: Graphene oxide, electrochemically reduced graphene oxide, silver nanoparticles and AgNPs-ErGO nanocomposite were synthesized and characterized using X-ray diffraction, Fourier-transform infrared spectroscopy, scanning electron microscopy combined with energy dispersive X-ray spectroscopy, Raman spectroscopy and high-resolution transmission electron microscopy. The AgNPs-ErGO-modified glassy carbon electrode was fabricated and used for sibutramine detection by linear sweep voltammetry. Experimental parameters affecting the analytical signal were optimized. The method was validated according to AOAC guidelines and compared with an HPLC-DAD reference method. Key results: The AgNPs-ErGO/GCE exhibited improved electrochemical response toward sibutramine compared with bare and other modified electrodes. The developed method showed good selectivity, linearity, precision, accuracy, and sensitivity for sibutramine determination. Application to commercial herbal weight-loss samples demonstrated the suitability of the proposed method for real sample analysis, with results comparable to those obtained by HPLC-DAD. Conclusion: The AgNPs-ErGO/ /GCE-based electrochemical method provides a rapid, cost-effective, and reliable approach for detecting sibutramine adulteration in herbal weight-loss products. This work contributes to the development of practical analytical tools for quality control and consumer safety monitoring.

  • Open Access

    NiFe₂O₄/(S,N)-doped graphene oxide composite as efficient electrochemical sensor for determination of sibutramine in dietary supplements

    by Ngo Thi Thanh Xuan, Le Thi Thanh Nhi, Nguyen Quang Man, Vo Thi Khanh Ly, Le Thi Hong Phong, Nguyen Hai Phong, Pham Khac Lieu, Le Lam Son, Dinh Quang Khieu

    A novel electrochemical sensor based on a NiFe₂O₄/(S,N)-doped graphene oxide compo­site (NiF/GrO(S,N)) was developed to detect sibutramine (SBT). The composite material was successfully synthesized and characterized using X-ray diffraction, Raman spectroscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, nitrogen adsorption/ /desorption isotherms, and vibrating sample magnetometry. Results confirmed the forma­tion of a nanocrystalline NiFe₂O₄ structure uniformly dispersed on S,N-doped graphene sheets, providing a high surface area and numerous active sites. The NiF/GrO(S,N)-modified glassy carbon electrode (GCE) showed improved electrocatalytic activity toward SBT oxidation. Under optimized conditions, differential pulse voltammetry revealed two linear ranges from 0.5 to 8.9 µM and 8.9 to 19.6 µM, with a detection limit of 0.37 µM. The sensor also demonstrated good repeatability, reproducibility, and stability, along with effective anti-interference capabilities against common inorganic and organic substances. The practical applicability of the proposed sensor was successfully demonstrated by determining SBT in seven commercial dietary supplement samples. The obtained recoveries ranged from 96.38 to 104.83 %, and the results showed no statistically significant difference compared with those obtained using the standard HPLC method. These results suggest that the NiF/GrO(S,N)/GCE sensor is a promising platform for the rapid and reliable detection of SBT in real samples.

  • Larvicidal activity and component interactions of Leonotis nepetifolia essential oil against Aedes aegypti

    by Thong Quoc Nguyen, Prabodh Satyal, Thuong Thanh Vo, The Van Pham, Trung Thanh Nguyen, Mau Dang Trinh, Phong Hai Nguyen, Hung Huy Nguyen, William N. Setzer

  • Open Access

    Development of a modified electrode using magnesium ferrite/activated carbon from coffee shell for determination of paracetamol

    by Phan Thi Kim Thu, Phan Tu Quy, Nguyen Mau Thanh, Nguyen Quang Man, Nguyen Hai Phong, Dinh Quang Khieu

    This study aimed to develop a simple and effective electrochemical sensor for detecting para­ce­tamol (PAR) in pharmaceutical tablets. The goal was to synthesize and utilize a novel nano­com­posite of magnesium ferrite, MgFe2O4, and activated carbon derived from coffee shells (MF/AC) as a high-performance electrode modifier. The MF/AC nanocomposite was produced using a hydrothermal method. It was characterized with techniques such as scanning electron micro­scopy, Fourier transform infrared spectroscopy, X-ray diffraction, energy-dispersive X-ray spec­troscopy, nitrogen adsorption/desorption, Raman spectroscopy and a vibrating sample mag­netometer. The electrochemical activity of the MF/AC-modified glassy carbon electrode (MF/AC-GCE) for PAR oxidation was evaluated by cyclic voltammetry and differential pulse voltammetry, with parameters such as scan rate and pH examined. The optimized sensor demonstrated excellent performance with two linear detection ranges for PAR: 1.0 to 9.9 µM (R2 = 0.999), and 9.9 to 47.62 µM (R2 = 0.999), with a low detection limit of 0.29 µM. The method was successfully applied to analyse five commercial pharmaceutical products, showing high accuracy, acceptable recovery rates, and strong agreement with High-performance liquid chromatography validation results. The developed MF/AC-GCE sensor provides a simple, effective, and environmentally friendly approach for the electrochemical detection of paracetamol. Its impressive performance suggests potential applications in pharmaceutical quality control and clinical diagnostics, offering a practical alternative to more complex analytical techniques.


  • Open Access

    Electrochemical determination of paracetamol and chlorpheniramine using AuNPs-rGO modified glassy carbon electrode

    by Huynh Van Chung, Nguyen Hai Phong, Dao Thi Cam Minh, Ho Xuan Anh Vu, Pham Khac Lieu, Nguyen Thi Thanh Huyen, Trinh Ngoc Dat, Doan Manh Dung, Do Thi Duyen, Dinh Quang Khieu

    One of the significant durability challenges is the corrosion of reinforced concrete. A gold nanoparticle/reduced graphene oxide modified glassy carbon electrode (AuNPs-rGO-GCE) was fabricated using an electrochemical reduction method for the simultaneous determination of paracetamol (PAR) and chlorpheniramine maleate (CPM). AuNPs-rGO modified GC electrodes were prepared through direct electrochemical reduction of GO to rGO, followed by direct reduction of Au ions to Au on the rGO matrix. X-ray diffraction, scanning electron microscopy, Fourier-transform infrared spectra, Raman spectroscopy, energy dispersive X-ray spectroscopy, high-resolution transmission electron microscopy, electrochemical impedance spectroscopy, and X-ray photoelectron spectroscopy characterized the resulting AuNPs-rGO. It was found that AuNPs around 15.4 nm were highly dispersed on the rGO. The modification of GCE by AuNPs-rGO accelerates the electron transfer process and increases the conductivity of the electrode. The AuNPs-rGO modified electrode was used to simultaneously determine PAR and CPM using the square-wave anodic stripping voltammetry (SQW-ASV) method. Under suitable experimental conditions, the SQW-ASV method using AuNPs-rGO-GCE showed a wide linear range from 23.7 to 140.0 µM for PAR and from 7.5 to 54.0 µM for CPM. The limit of detection of PAR and CPM was 7.12 and 2.54 µM, respectively. The proposed SQW-ASV method was applied to analyze PAR and CPM in samples of herbal medicine simultaneously, and the results were compared with those of high-performance liquid chromatography, with no statistical difference.


  • Open Access

    XÁC ĐỊNH ĐỒNG THỜI PARACETAMOL, CLOPHENIRAMINE MALEATE, CINARIZIN, LORATADINE VÀ CETIRIZINE HYDROCLORIDE TRONG CHẾ PHẨM CÓ NGUỒN GỐC TỪ DƯỢC LIỆU BẰNG PHƯƠNG PHÁP SẮC KÝ LỎNG HIỆU NĂNG CAO

    by Văn Chung Huỳnh, Thị Cẩm Minh Đào, Thị Thu Thủy Trần, Hải Phong Nguyễn

    Bài báo này trình bày quá trình xây dựng phương pháp định lượng đồng thời paracetamol (PAR), clopheniramine maleate (CPM), cinarizin (CIN), loratadine (LOR) và cetirizine hydrocloride (CET) trong chế phẩm có nguồn gốc từ dược liệu bằng phương pháp sắc ký lỏng hiệu năng cao (HPLC) với đầu dò PDA. Phương pháp phân tích được thực hiện ở điều kiện sắc ký: cột InertSustainTM C18 (250 mm × 4,6 mm, 5 μm); pha động là hỗn hợp hai kênh ACN (A) và 5 mM NaH2PO4 (pH = 2,3) (B) theo chương trình gradient; tốc độ dòng: 1,0 mL/phút; thể tích tiêm mẫu: 20 μL; nhiệt độ cột: 40 °C; Bước sóng phát hiện: PAR: 245 nm, CPM: 225 nm, CET: 230 nm, LOR: 254 nm và CIN: 253 nm. Phương pháp phân tích đã được thẩm định theo hướng dẫn của ICH và AOAC. Giới hạn phát hiện của PAR, CPM, CET, LOR, và CIN lần lượt là 2,00, 2,00, 1,75, 1,00 và 0,50 µg/mL. Quy trình đã được ứng dụng để phân tích 32 mẫu chế phẩm đông dược khác nhau thu thập trên thị trường.

  • Open Access

    NGHIÊN CỨU XÁC ĐỊNH ĐỒNG THỜI CHÌ VÀ CADIMI TRONG MÔI TRƯỜNG NƯỚC BẰNG PHƯƠNG PHÁP VON-AMPE HÒA TAN SỬ DỤNG ĐIỆN CỰC BIẾN TÍNH BiF/ErGO-GCE

    by Nguyễn Đình Luyện, Hà Thùy Trang, Ho Xuan Anh Vu Vu, Nguyễn Hải Phong

    Hue Univsersity Journal of Science: Natural Science

  • Simultaneous determination of Pb(II) and Cd(II) by electrochemical method using ZnO/ErGO-modified electrode

    by Nguyen Dinh Luyen, Ha Thuy Trang, Pham Yen Khang, Nguyen Mau Thanh, Ho Xuan Anh Vu, Nguyen Hai Phong, Dinh Quang Khieu


  • Open Access

    Single versus Double Coffee-Ring Effect Patterns in Thin-Layer Chromatography Coupled with Surface-Enhanced Raman Spectroscopic Analysis of Anti-Diabetic Drugs Adulterated in Herbal Products

    by Dao Thi Cam Minh, Le Thi Bao Tram, Nguyen Hai Phong, Hoang Thi Lan Huong, Le Van Vu, Le Anh Thi, Nguyen Thi Kieu Anh, Pham Thi Thanh Ha

    In thin-layer chromatography coupled with surface-enhanced Raman spectroscopy (TLC-SERS), the coffee ring effect (CRE) describes the formation of a ring-shape spot (blank in the middle and darker on the edge) caused by the aggregation of silver nanoparticles (Ag NPs), alone (single CRE) or with the analytes (double CRE). In this work, the SCRE and DCRE were investigated in two anti-diabetic drugs, hydrophobic glibenclamide (GLB) and more hydrophilic metformin (MET). The SCRE occurred in GLB analysis, as opposed to the DCRE that occurred in MET. It was proven that for optimization of the TLC-SERS analytical procedure, it is necessary to distinguish the CRE patterns of analytes. Additionally, MET and GLB were analyzed with the developed TLC-SERS method and confirmed by another validated method using high-performance liquid chromatography. Four herbal products collected on the market were found to be adulterated with GLB or/and MET; among those, one product was adulterated with both MET and GLB, and two products were adulterated with GLB at a higher concentration than the usual GLB prescription dose. The TLC-SERS method provided a useful tool for the simultaneous detection of adulterated anti-diabetic herbal products, and the comparison of the SCRE and DCRE provided more evidence to predict CRE patterns in TLC-SERS.