Masume Khodsuz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Masume Khodsuz has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Seyyedmeysam Seyyedbarzegar
Department of Electrical Engineering, Shahrood University of Technology, Shahrood, Iran
3 shared publications - Mohammad Gholami
Department of Electrical and Computer Engineering University of Science and Technology of Mazandaran Behshahr Iran
2 shared publications Hassan Mahdavi
Department of Electrical and Computer Engineering Babol Noshirvani University of Technology Babol Iran
1 shared publicationHassan Nouri
School of Engineering Power Systems Research Laboratory University of the West of England Bristol UK
1 shared publicationMehdi Esmaieli
Faculty of Electrical and Computer Engineering University of Science and Technology of Mazandaran Behshahr Iran
1 shared publicationMohammad Haghjoo‐Haghighi
Department of Electrical and Computer Engineering University of Science and Technology of Mazandaran Behshahr Iran
1 shared publication
Latest Publications
- Open Access
- 19 October 2026
- Published by Institution of Engineering and Technology (IET) in Vector: The Journal of Engineering
- Vol. 2027 (1)
Islanding Detection in Power Distribution Systems Using a Hybrid Machine Learning Approach
The increasing integration of distributed generation units, especially synchronous generators, into modern power systems emphasises the critical need for reliable islanding detection methods. This paper proposes a hybrid islanding detection approach that combines passive monitoring of multiple electrical parameters—such as negative sequence voltage, generator field voltage, and the rate of change of positive sequence impedance—with intelligent machine learning techniques. To enhance detection accuracy, the approach incorporates feature standardisation, Adaptive Synthetic Sampling for data augmentation, Recursive Feature Elimination for optimal feature selection, and a stacking ensemble integrating XGBoost and Random Forest models. The method is evaluated under various network conditions, including load switching, capacitor bank operations, faults, and islanding events, using a modified IEEE 34‐bus distribution system. Simulation results demonstrate that the proposed hybrid method achieves high accuracy, robustness, and generalisability across diverse operating conditions, making it a promising solution for reliable islanding detection in distribution networks.
- 19 October 2026
- Published by Institution of Engineering and Technology (IET) in Vector: The Journal of Engineering
- Vol. 2027 (1)
Open AccessIslanding Detection in Power Distribution Systems Using a Hybrid Machine Learning Approach
The increasing integration of distributed generation units, especially synchronous generators, into modern power systems emphasises the critical need for reliable islanding detection methods. This paper proposes a hybrid islanding detection approach that combines passive monitoring of multiple electrical parameters—such as negative sequence voltage, generator field voltage, and the rate of change of positive sequence impedance—with intelligent machine learning techniques. To enhance detection accuracy, the approach incorporates feature standardisation, Adaptive Synthetic Sampling for data augmentation, Recursive Feature Elimination for optimal feature selection, and a stacking ensemble integrating XGBoost and Random Forest models. The method is evaluated under various network conditions, including load switching, capacitor bank operations, faults, and islanding events, using a modified IEEE 34‐bus distribution system. Simulation results demonstrate that the proposed hybrid method achieves high accuracy, robustness, and generalisability across diverse operating conditions, making it a promising solution for reliable islanding detection in distribution networks.
- Open Access
- 29 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Condition-based washing decision of high-voltage insulators using leakage current harmonic–phase analysis
- 29 August 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessCondition-based washing decision of high-voltage insulators using leakage current harmonic–phase analysis
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Operational Planning of Hydrogen Energy Storage Systems Using Risk‐Averse Stochastic Programming
This paper presents a scenario‐based stochastic optimization framework for mobile hydrogen energy storage systems (HESS) integrated with renewable generation and demand response. The model captures relocation dynamics across multiple buses and incorporates financial risk using conditional value‐at‐risk (CVaR). Key features include scenario reduction for wind and solar uncertainties, downside risk constraints, and temporal coupling between relocation and energy states. The objective function balances expected operating cost and risk exposure, enabling robust dispatch under uncertainty. Simulations on the IEEE 33‐bus system show that mobile HESS units outperform stationary hydrogen configurations, achieving up to 8.4% cost reduction despite relocation penalties. Benchmarking against mobile battery systems reveals that battery‐based setups yield lower operating costs—approximately 9.9% less—due to higher round‐trip efficiency. However, the spatial and long‐duration flexibility of HESS remains a strategic advantage, especially under extended congestion. The proposed framework advances mobile energy storage modelling by integrating mobility, uncertainty management, and risk‐aware dispatch. It offers a scalable solution for resilient energy planning and can be extended to include load‐dependent efficiency, probabilistic demand response, and multi‐carrier energy coordination.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessOperational Planning of Hydrogen Energy Storage Systems Using Risk‐Averse Stochastic Programming
This paper presents a scenario‐based stochastic optimization framework for mobile hydrogen energy storage systems (HESS) integrated with renewable generation and demand response. The model captures relocation dynamics across multiple buses and incorporates financial risk using conditional value‐at‐risk (CVaR). Key features include scenario reduction for wind and solar uncertainties, downside risk constraints, and temporal coupling between relocation and energy states. The objective function balances expected operating cost and risk exposure, enabling robust dispatch under uncertainty. Simulations on the IEEE 33‐bus system show that mobile HESS units outperform stationary hydrogen configurations, achieving up to 8.4% cost reduction despite relocation penalties. Benchmarking against mobile battery systems reveals that battery‐based setups yield lower operating costs—approximately 9.9% less—due to higher round‐trip efficiency. However, the spatial and long‐duration flexibility of HESS remains a strategic advantage, especially under extended congestion. The proposed framework advances mobile energy storage modelling by integrating mobility, uncertainty management, and risk‐aware dispatch. It offers a scalable solution for resilient energy planning and can be extended to include load‐dependent efficiency, probabilistic demand response, and multi‐carrier energy coordination.
- Open Access
- 30 January 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (5) , 1072-1089
New criteria for metal oxide surge arrester condition monitoring based on leakage current analysis: Considering non‐uniform pollution effect
The role of surge arresters is vital in power systems' protection against transient overvoltages, which can arise due to occurrences like lightning strikes or switching operations. Based on the performance of the surge arrester, assessing its condition is an essential requirement for early detection of any damage or deterioration. This article proposes innovative criteria based on the surge arresters’ leakage current analysis for the classification of uniform and non‐uniform pollution levels. The leakage current signal of clean, uniform, and non‐uniform polluted surge arresters has been examined under different contamination levels, humidity, and non‐uniformity degrees. Based on the experimental results analysis, a new criterion has been proposed for assessing the surge arrester condition, which has resulted from the fifth and first‐order harmonics ratio of resistive leakage current. Analysis of the proposed criterion demonstrates that this index has a significant correlation to the pollution level. The proposed criterion ability has been established based on random forest, support vector machine, decision tree algorithm, and multi‐layer perceptron in Python language. The obtained criterion based on experimental data in different conditions has been employed for classifier training, which can be applied in the power network for better condition monitoring of surge arresters ensuring fast and accurate outcomes.
- 30 January 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (5) , 1072-1089
Open AccessNew criteria for metal oxide surge arrester condition monitoring based on leakage current analysis: Considering non‐uniform pollution effect
The role of surge arresters is vital in power systems' protection against transient overvoltages, which can arise due to occurrences like lightning strikes or switching operations. Based on the performance of the surge arrester, assessing its condition is an essential requirement for early detection of any damage or deterioration. This article proposes innovative criteria based on the surge arresters’ leakage current analysis for the classification of uniform and non‐uniform pollution levels. The leakage current signal of clean, uniform, and non‐uniform polluted surge arresters has been examined under different contamination levels, humidity, and non‐uniformity degrees. Based on the experimental results analysis, a new criterion has been proposed for assessing the surge arrester condition, which has resulted from the fifth and first‐order harmonics ratio of resistive leakage current. Analysis of the proposed criterion demonstrates that this index has a significant correlation to the pollution level. The proposed criterion ability has been established based on random forest, support vector machine, decision tree algorithm, and multi‐layer perceptron in Python language. The obtained criterion based on experimental data in different conditions has been employed for classifier training, which can be applied in the power network for better condition monitoring of surge arresters ensuring fast and accurate outcomes.
- Open Access
- 28 December 2023
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 18 (4) , 163-181
Condition assessment criteria evaluation of asymmetric aged and fully aged silicone rubber insulators based on leakage current harmonics
The leakage current characteristic monitoring of transmission line insulators is considered a worthy technique for insulator state prediction. In this paper, the harmonic analysis of leakage current signals has been performed to analyze the composite insulator condition. Experimental studies of asymmetrically aged, fully aged, and virgin insulators have been conducted. The effects of different aging types, pollution, and humidity on leakage current components, such as harmonics and the phase differences with the applied voltage, have been investigated. The analysis of the results shows that the effect of asymmetric aging on leakage current components is non‐linear, and this non‐linearity increases with the degree of pollution. Also, the type of insulator aging can be determined by the ratio of the third‐ and fifth‐order leakage current harmonics. For instance, the classification of insulators into virgin, asymmetrically aged, and fully aged can be determined by examining the corresponding value ranges of 0–0.5, 0.5–0.9, and > 0.9, respectively. Similarly, the phase difference values of < 15% and those > 15% indicate the clean and polluted operating conditions individually.
- 28 December 2023
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 18 (4) , 163-181
Open AccessCondition assessment criteria evaluation of asymmetric aged and fully aged silicone rubber insulators based on leakage current harmonics
The leakage current characteristic monitoring of transmission line insulators is considered a worthy technique for insulator state prediction. In this paper, the harmonic analysis of leakage current signals has been performed to analyze the composite insulator condition. Experimental studies of asymmetrically aged, fully aged, and virgin insulators have been conducted. The effects of different aging types, pollution, and humidity on leakage current components, such as harmonics and the phase differences with the applied voltage, have been investigated. The analysis of the results shows that the effect of asymmetric aging on leakage current components is non‐linear, and this non‐linearity increases with the degree of pollution. Also, the type of insulator aging can be determined by the ratio of the third‐ and fifth‐order leakage current harmonics. For instance, the classification of insulators into virgin, asymmetrically aged, and fully aged can be determined by examining the corresponding value ranges of 0–0.5, 0.5–0.9, and > 0.9, respectively. Similarly, the phase difference values of < 15% and those > 15% indicate the clean and polluted operating conditions individually.
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1547-1556
Harmonic Analysis of Metal Oxide Surge Arrester Leakage Current Considering Fan-Shaped Type Pollution Effect
This paper investigates the leakage current (LC) analysis of metal oxide surge arresters (MOSA) under both uniform and fan-shape as a non-uniform pollution conditions and at different humidity levels (H), through experimental methods. The main contribution of the paper is examining the effect of fan-shape pollution on MOSA leakage current. Increasing the degree of non-uniformity (D) decreases the MOSA leakage current and its harmonic components. The experimental results show that D has a greater impact on reducing the harmonic components of the resistive leakage current, with a lesser effect on the fifth-order harmonic (Ir5) compared to the first (Ir1) and third-order harmonics (Ir3). The first, third, and fifth-order harmonics of the resistive leakage current demonstrate an approximate linear relationship with D. Therefore, D can influence on condition monitoring criteria, potentially leading to incorrect diagnosis of the MOSA condition. For instance, variation of pollution from uniform to D = 0.75 causes a two-fold decrease in the Ir3/Ir5 criterion.
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1547-1556
Harmonic Analysis of Metal Oxide Surge Arrester Leakage Current Considering Fan-Shaped Type Pollution Effect
This paper investigates the leakage current (LC) analysis of metal oxide surge arresters (MOSA) under both uniform and fan-shape as a non-uniform pollution conditions and at different humidity levels (H), through experimental methods. The main contribution of the paper is examining the effect of fan-shape pollution on MOSA leakage current. Increasing the degree of non-uniformity (D) decreases the MOSA leakage current and its harmonic components. The experimental results show that D has a greater impact on reducing the harmonic components of the resistive leakage current, with a lesser effect on the fifth-order harmonic (Ir5) compared to the first (Ir1) and third-order harmonics (Ir3). The first, third, and fifth-order harmonics of the resistive leakage current demonstrate an approximate linear relationship with D. Therefore, D can influence on condition monitoring criteria, potentially leading to incorrect diagnosis of the MOSA condition. For instance, variation of pollution from uniform to D = 0.75 causes a two-fold decrease in the Ir3/Ir5 criterion.
- Open Access
- 12 October 2023
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 17 (22) , 4975-4990
Externally gapped line arresters placement effect on transmission line lightning performance including the frequency response of the grounding system
This paper conducts the frequency‐dependent grounding system impact on externally gapped line arresters (EGLAs) operation and their placement effects on the lightning performance of a transmission line (TL). The study involves placing EGLAs at different phases of a 400‐kV double‐circuit TL with two downstream shield wires and selecting the optimal state with fewer back‐flashover incidents. The results show that using a non‐linear grounding system leads to a higher back return current from insulators or EGLAs, resulting in a higher flashover rate compared to the frequency grounding system (FGS). Installing four EGLAs in the middle and upper phases of the TL provides satisfactory lightning protection, and the flashover probability is zero and 4.2% for the FGS and the non‐linear grounding system, respectively. A sensitivity analysis including soil resistor variation, economic analysis, and grounding electrode configuration has been performed that confirms installing downstream shield wires and EGLAs is an effective and economical technique for lightning protection.
- 12 October 2023
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 17 (22) , 4975-4990
Open AccessExternally gapped line arresters placement effect on transmission line lightning performance including the frequency response of the grounding system
This paper conducts the frequency‐dependent grounding system impact on externally gapped line arresters (EGLAs) operation and their placement effects on the lightning performance of a transmission line (TL). The study involves placing EGLAs at different phases of a 400‐kV double‐circuit TL with two downstream shield wires and selecting the optimal state with fewer back‐flashover incidents. The results show that using a non‐linear grounding system leads to a higher back return current from insulators or EGLAs, resulting in a higher flashover rate compared to the frequency grounding system (FGS). Installing four EGLAs in the middle and upper phases of the TL provides satisfactory lightning protection, and the flashover probability is zero and 4.2% for the FGS and the non‐linear grounding system, respectively. A sensitivity analysis including soil resistor variation, economic analysis, and grounding electrode configuration has been performed that confirms installing downstream shield wires and EGLAs is an effective and economical technique for lightning protection.
- Open Access
Optimal Design of C-Type Filter in Harmonics Polluted Distribution Systems
This paper aims to find the optimal size of parameters of a C-type filter in a non-sinusoidal system using a new optimization method called the Archimedes optimization algorithm (AOA). The inductance and capacitance values of the filter are acquired in which the power loss in the Thevenin resistor and the power loss characteristics of the load bus are minimized based on a new proposed objective function. Subject to technical and practical limitations of the IEEE 519 standard, an optimization problem is defined to achieve an optimal filter design that can increase the system power quality. The effectiveness of the proposed method is proved by comparison with the recent previously published methods. The results show the effectiveness of the proposed approach using the AOA in finding the minimum power losses and the harmonic content of frequency-dependent components. Eventually, the current study confirmed that the suggested objective function minimizes power losses of fundamental and harmonic order harmonics in non-sinusoidal systems.
Open AccessOptimal Design of C-Type Filter in Harmonics Polluted Distribution Systems
This paper aims to find the optimal size of parameters of a C-type filter in a non-sinusoidal system using a new optimization method called the Archimedes optimization algorithm (AOA). The inductance and capacitance values of the filter are acquired in which the power loss in the Thevenin resistor and the power loss characteristics of the load bus are minimized based on a new proposed objective function. Subject to technical and practical limitations of the IEEE 519 standard, an optimization problem is defined to achieve an optimal filter design that can increase the system power quality. The effectiveness of the proposed method is proved by comparison with the recent previously published methods. The results show the effectiveness of the proposed approach using the AOA in finding the minimum power losses and the harmonic content of frequency-dependent components. Eventually, the current study confirmed that the suggested objective function minimizes power losses of fundamental and harmonic order harmonics in non-sinusoidal systems.
- 31 March 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 102 (3) , 521-530
Modeling of Gapless MOSA at Low Current Region Considering Harmonic Content of Operating Voltage
- 31 March 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 102 (3) , 521-530
Modeling of Gapless MOSA at Low Current Region Considering Harmonic Content of Operating Voltage