Seyyedmeysam Seyyedbarzegar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Seyyedmeysam Seyyedbarzegar has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Mahdi Mahamed
Faculty of Electrical Engineering, Shahrood University of Technology, Shahrood 3619995161, Iran
4 shared publications - Masume Khodsuz
Faculty of Electrical and Computer Engineering University of Science and Technology of Mazandaran Behshahr Iran
3 shared publications A. Samani
Faculty of Electrical Engineering Shahrood University of Technology Shahrood Iran
2 shared publicationsA. Darabi
Department of Electrical Engineering, Shahrood University of Technology, Shahrood, Iran
1 shared publicationA. H. Mashhadzadeh
Department of Electrical Engineering, Gorgan Branch, Islamic Azad University, Gorgan, Iran
1 shared publicationArian Hoseini Nejadiyan Kooshki
Faculty of Electrical Engineering, Shahrood University of Technology, Shahrood, Iran
1 shared publication
Latest Publications
- 1 January 2026
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 39 (10) , 2407-2418
Condition Monitoring of Silicone Rubber Insulators Using Criteria Established through Wavelet Transform Analysis
- 1 January 2026
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 39 (10) , 2407-2418
Condition Monitoring of Silicone Rubber Insulators Using Criteria Established through Wavelet Transform Analysis
- Open Access
- 1 January 2026
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 39 (3) , 789-801
Proposing Surge Arrester Monitoring Indicators and Their Evaluation Using Correlation Coefficient Method: Considering the Effect of Longitudinal and Fan-shaped Type Non-uniform Pollution
Monitoring the status of surge arrester has always been considered as an important operation in the power system. In this paper, a new method has been proposed to assess indexes of metal oxide surge arrester monitoring based on correlation coefficients with environmental conditions. In this regard, the surge arrester leakage current was experimentally measured under different humidity and pollution levels for fan-shaped (D) and longitudinal (Z) contaminations. The impact of light, medium, and heavy pollution on the leakage current was examined under humidity from 60 to 90%. New indexes have been proposed with the aim of assessing the surge arrester performance, which are based on the harmonic components of the leakage current and the phase angles of the applied voltage and leakage current. The effect of the humidity and pollution level on the new and conventional indexes has been analyzed with respect to the Pearson correlation under uniform and non-uniform pollution. The results show that the correlation between the proposed indexes and humidity, pollution type, and level is greater than that of the conventional indexes. Also, the index based on the phase difference has the best performance relative to the other indexes.
- 1 January 2026
- Published by International Digital Organization for Scientific Information (IDOSI) in International Journal of Engineering
- Vol. 39 (3) , 789-801
Open AccessProposing Surge Arrester Monitoring Indicators and Their Evaluation Using Correlation Coefficient Method: Considering the Effect of Longitudinal and Fan-shaped Type Non-uniform Pollution
Monitoring the status of surge arrester has always been considered as an important operation in the power system. In this paper, a new method has been proposed to assess indexes of metal oxide surge arrester monitoring based on correlation coefficients with environmental conditions. In this regard, the surge arrester leakage current was experimentally measured under different humidity and pollution levels for fan-shaped (D) and longitudinal (Z) contaminations. The impact of light, medium, and heavy pollution on the leakage current was examined under humidity from 60 to 90%. New indexes have been proposed with the aim of assessing the surge arrester performance, which are based on the harmonic components of the leakage current and the phase angles of the applied voltage and leakage current. The effect of the humidity and pollution level on the new and conventional indexes has been analyzed with respect to the Pearson correlation under uniform and non-uniform pollution. The results show that the correlation between the proposed indexes and humidity, pollution type, and level is greater than that of the conventional indexes. Also, the index based on the phase difference has the best performance relative to the other indexes.
- Open Access
- 27 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1)
Surge arrester leakage current modeling based on pollution layer electrical conductivity estimation
The surface leakage current (LC) of metal oxide surge arresters (MOSA) is highly dependent on environmental conditions. This factor influences the modeling of MOSA leakage current as an alternative solution to laboratory tests. In this paper, a new approach to modeling the surface leakage current of MOSA based on the estimation of the electrical conductivity (EC) of the contaminated layer is presented, which provides the ability to model the surge arrester LC in different environmental conditions with high accuracy. The estimation of the EC of the polluted layer has been performed using artificial intelligence (AI) based on laboratory tests considering the effect of uniform and non-uniform pollution, humidity, pollution intensity and voltage on three types of 20 kV silicon rubber surge arresters. Mean Squared Error (MSE) and Coefficient of Determination were used for assessing the ability of AI based method in EC estimation. Finite element method (FEM)-based software has been used for surge arrester modeling. The use of the estimated electrical conductivity characteristic in the FEM model has made it possible to evaluate the effect of the internal and external currents of the MOSA on the total leakage current in different scenarios. The comparison of the results obtained from proposed model and laboratory test indicate the capability of the proposed method in estimating the EC, modeling the LC, and their generalization to cases for which laboratory test results are not available.
- 27 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1)
Open AccessSurge arrester leakage current modeling based on pollution layer electrical conductivity estimation
The surface leakage current (LC) of metal oxide surge arresters (MOSA) is highly dependent on environmental conditions. This factor influences the modeling of MOSA leakage current as an alternative solution to laboratory tests. In this paper, a new approach to modeling the surface leakage current of MOSA based on the estimation of the electrical conductivity (EC) of the contaminated layer is presented, which provides the ability to model the surge arrester LC in different environmental conditions with high accuracy. The estimation of the EC of the polluted layer has been performed using artificial intelligence (AI) based on laboratory tests considering the effect of uniform and non-uniform pollution, humidity, pollution intensity and voltage on three types of 20 kV silicon rubber surge arresters. Mean Squared Error (MSE) and Coefficient of Determination were used for assessing the ability of AI based method in EC estimation. Finite element method (FEM)-based software has been used for surge arrester modeling. The use of the estimated electrical conductivity characteristic in the FEM model has made it possible to evaluate the effect of the internal and external currents of the MOSA on the total leakage current in different scenarios. The comparison of the results obtained from proposed model and laboratory test indicate the capability of the proposed method in estimating the EC, modeling the LC, and their generalization to cases for which laboratory test results are not available.
- Open Access
- 17 September 2025
- Published by Elsevier in Results in Engineering
- Vol. 28
Electrical equivalent circuit modeling of self-shielding DC high temperature superconducting cable considering the effect of fault on its electrothermal performance
- 17 September 2025
- Published by Elsevier in Results in Engineering
- Vol. 28
Open AccessElectrical equivalent circuit modeling of self-shielding DC high temperature superconducting cable considering the effect of fault on its electrothermal performance
- Open Access
Impact of Nanoparticles on Heat Transfer Enhancement and Thermal Performance Improvement in HTS Power Transformers
Despite the numerous benefits of high-temperature superconducting (HTS) power transformers, they are highly sensitive and vulnerable from a thermal perspective, particularly under fault current conditions due to their fault current tolerance properties. Ensuring the proper operation of the cooling system can enhance the transformer’s performance during fault and overload conditions. To improve the thermal management of this transformer in both convective heat transfer and nucleate boiling conditions, utilizing liquid nitrogen (LN2) nanofluid instead of conventional LN2 is a promising solution. In this study, a two-phase Eulerian model using ANSYS Fluent software is employed to analyze the impact of different volume fractions (VFs) of Al2O3 nanoparticles with a 40 nm diameter on the cooling performance of a power HTS transformer. The numerical simulations are conducted using the Ranz–Marshal method for heat transfer and the finite element method for solving the governing equations. Nanoparticle concentrations ranging from 0 to 1% are evaluated under various fault conditions. Additionally, the influence of nanoparticles on bubble behavior is examined, partially mitigating the blockage of cooler microchannels. The simulation reveals that adding nanoparticles to the fluid reduces the temperature of the hotspot by 29% in steady state and by 34–52% under different fault currents as a result of 0–46% enhancement of nucleate boiling heat transfer, thereby improving the cooling efficiency of the transformer.
Open AccessImpact of Nanoparticles on Heat Transfer Enhancement and Thermal Performance Improvement in HTS Power Transformers
Despite the numerous benefits of high-temperature superconducting (HTS) power transformers, they are highly sensitive and vulnerable from a thermal perspective, particularly under fault current conditions due to their fault current tolerance properties. Ensuring the proper operation of the cooling system can enhance the transformer’s performance during fault and overload conditions. To improve the thermal management of this transformer in both convective heat transfer and nucleate boiling conditions, utilizing liquid nitrogen (LN2) nanofluid instead of conventional LN2 is a promising solution. In this study, a two-phase Eulerian model using ANSYS Fluent software is employed to analyze the impact of different volume fractions (VFs) of Al2O3 nanoparticles with a 40 nm diameter on the cooling performance of a power HTS transformer. The numerical simulations are conducted using the Ranz–Marshal method for heat transfer and the finite element method for solving the governing equations. Nanoparticle concentrations ranging from 0 to 1% are evaluated under various fault conditions. Additionally, the influence of nanoparticles on bubble behavior is examined, partially mitigating the blockage of cooler microchannels. The simulation reveals that adding nanoparticles to the fluid reduces the temperature of the hotspot by 29% in steady state and by 34–52% under different fault currents as a result of 0–46% enhancement of nucleate boiling heat transfer, thereby improving the cooling efficiency of the transformer.
- Open Access
- 30 January 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (5) , 1072-1089
New criteria for metal oxide surge arrester condition monitoring based on leakage current analysis: Considering non‐uniform pollution effect
The role of surge arresters is vital in power systems' protection against transient overvoltages, which can arise due to occurrences like lightning strikes or switching operations. Based on the performance of the surge arrester, assessing its condition is an essential requirement for early detection of any damage or deterioration. This article proposes innovative criteria based on the surge arresters’ leakage current analysis for the classification of uniform and non‐uniform pollution levels. The leakage current signal of clean, uniform, and non‐uniform polluted surge arresters has been examined under different contamination levels, humidity, and non‐uniformity degrees. Based on the experimental results analysis, a new criterion has been proposed for assessing the surge arrester condition, which has resulted from the fifth and first‐order harmonics ratio of resistive leakage current. Analysis of the proposed criterion demonstrates that this index has a significant correlation to the pollution level. The proposed criterion ability has been established based on random forest, support vector machine, decision tree algorithm, and multi‐layer perceptron in Python language. The obtained criterion based on experimental data in different conditions has been employed for classifier training, which can be applied in the power network for better condition monitoring of surge arresters ensuring fast and accurate outcomes.
- 30 January 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (5) , 1072-1089
Open AccessNew criteria for metal oxide surge arrester condition monitoring based on leakage current analysis: Considering non‐uniform pollution effect
The role of surge arresters is vital in power systems' protection against transient overvoltages, which can arise due to occurrences like lightning strikes or switching operations. Based on the performance of the surge arrester, assessing its condition is an essential requirement for early detection of any damage or deterioration. This article proposes innovative criteria based on the surge arresters’ leakage current analysis for the classification of uniform and non‐uniform pollution levels. The leakage current signal of clean, uniform, and non‐uniform polluted surge arresters has been examined under different contamination levels, humidity, and non‐uniformity degrees. Based on the experimental results analysis, a new criterion has been proposed for assessing the surge arrester condition, which has resulted from the fifth and first‐order harmonics ratio of resistive leakage current. Analysis of the proposed criterion demonstrates that this index has a significant correlation to the pollution level. The proposed criterion ability has been established based on random forest, support vector machine, decision tree algorithm, and multi‐layer perceptron in Python language. The obtained criterion based on experimental data in different conditions has been employed for classifier training, which can be applied in the power network for better condition monitoring of surge arresters ensuring fast and accurate outcomes.
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1547-1556
Harmonic Analysis of Metal Oxide Surge Arrester Leakage Current Considering Fan-Shaped Type Pollution Effect
This paper investigates the leakage current (LC) analysis of metal oxide surge arresters (MOSA) under both uniform and fan-shape as a non-uniform pollution conditions and at different humidity levels (H), through experimental methods. The main contribution of the paper is examining the effect of fan-shape pollution on MOSA leakage current. Increasing the degree of non-uniformity (D) decreases the MOSA leakage current and its harmonic components. The experimental results show that D has a greater impact on reducing the harmonic components of the resistive leakage current, with a lesser effect on the fifth-order harmonic (Ir5) compared to the first (Ir1) and third-order harmonics (Ir3). The first, third, and fifth-order harmonics of the resistive leakage current demonstrate an approximate linear relationship with D. Therefore, D can influence on condition monitoring criteria, potentially leading to incorrect diagnosis of the MOSA condition. For instance, variation of pollution from uniform to D = 0.75 causes a two-fold decrease in the Ir3/Ir5 criterion.
- 15 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (3) , 1547-1556
Harmonic Analysis of Metal Oxide Surge Arrester Leakage Current Considering Fan-Shaped Type Pollution Effect
This paper investigates the leakage current (LC) analysis of metal oxide surge arresters (MOSA) under both uniform and fan-shape as a non-uniform pollution conditions and at different humidity levels (H), through experimental methods. The main contribution of the paper is examining the effect of fan-shape pollution on MOSA leakage current. Increasing the degree of non-uniformity (D) decreases the MOSA leakage current and its harmonic components. The experimental results show that D has a greater impact on reducing the harmonic components of the resistive leakage current, with a lesser effect on the fifth-order harmonic (Ir5) compared to the first (Ir1) and third-order harmonics (Ir3). The first, third, and fifth-order harmonics of the resistive leakage current demonstrate an approximate linear relationship with D. Therefore, D can influence on condition monitoring criteria, potentially leading to incorrect diagnosis of the MOSA condition. For instance, variation of pollution from uniform to D = 0.75 causes a two-fold decrease in the Ir3/Ir5 criterion.