Zafer Ortatepe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zafer Ortatepe has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Ahmet Karaarslan
The Department of Electrical and Electronics Engineering Ankara Yıldırım Beyazıt University Ankara Turkey
3 shared publications- Sadık Özdemir
Pamukkale Universitesi
3 shared publications - Ahmet Karaarslan
Yildirim Beyazit University
2 shared publications - Eren Özlü
Pamukkale Universitesi
1 shared publication - Fatih Süleyman Taşkincan
Ankara Yildirim Beyazit University
1 shared publication Hüseyin Akgül
The Department of Automotive Engineering Pamukkale University Denizli Turkey
1 shared publication
Latest Publications
- 30 September 2026
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 14 (3) , 1313-1326
Three-Level Boost Converter-Based Single-Phase Five-Level T-Type Inverter
This study proposes a cascaded power conversion structure composed of a three-level DC-DC boost converter and a single-phase five-level T-type inverter to address the high performance and power quality demands of renewable energy systems. The integrated topology is designed to overcome the limitations of conventional two-level architectures by combining high voltage gain with reduced voltage stress on power switches and minimized total harmonic distortion (THD). The paper presents a comprehensive mathematical model and a robust control strategy, utilizing decoupled loops for total DC-link voltage regulation and neutral-point balancing, alongside a synchronous reference frame current controller for the inverter stage. Simulation studies conducted in the MATLAB/Simulink environment validate the operational characteristics of the proposed system. The results demonstrate that the boost stage maintains a stable symmetric DC link voltage of 350𝑉𝑑𝑐 (∓175𝑉𝑑𝑐). Furthermore, the T-type inverter generates a five-level output waveform with a THD as low as 1.22% under steady-state conditions and 1.01% under dynamic loading, compliant with IEEE 519 standards. This confirms the system capability to reduce voltage stress on switches by 50% while ensuring high-quality power delivery.
- 30 September 2026
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 14 (3) , 1313-1326
Three-Level Boost Converter-Based Single-Phase Five-Level T-Type Inverter
This study proposes a cascaded power conversion structure composed of a three-level DC-DC boost converter and a single-phase five-level T-type inverter to address the high performance and power quality demands of renewable energy systems. The integrated topology is designed to overcome the limitations of conventional two-level architectures by combining high voltage gain with reduced voltage stress on power switches and minimized total harmonic distortion (THD). The paper presents a comprehensive mathematical model and a robust control strategy, utilizing decoupled loops for total DC-link voltage regulation and neutral-point balancing, alongside a synchronous reference frame current controller for the inverter stage. Simulation studies conducted in the MATLAB/Simulink environment validate the operational characteristics of the proposed system. The results demonstrate that the boost stage maintains a stable symmetric DC link voltage of 350𝑉𝑑𝑐 (∓175𝑉𝑑𝑐). Furthermore, the T-type inverter generates a five-level output waveform with a THD as low as 1.22% under steady-state conditions and 1.01% under dynamic loading, compliant with IEEE 519 standards. This confirms the system capability to reduce voltage stress on switches by 50% while ensuring high-quality power delivery.
- 31 March 2026
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 13 (1) , 419-433
A Computationally Efficient Sequential RLS Estimator for PMSM Parameters: Algorithm Design and Experimental Verification
Accurate knowledge of electrical parameters is crucial for high-performance field oriented control (FOC) of permanent magnet synchronous motors (PMSMs). However, parameters vary significantly due to thermal effects and magnetic saturation. This study proposes a computationally efficient sequential recursive least squares (SRLS) algorithm for real-time parameter identification. Unlike conventional methods, proposed approach decouples the d- and q-axis dynamics to reduce the matrix operation complexity. Identification is achieved under persistent excitation provided by the active torque current (i_q) and the standard FOC scheme at a 20 kHz sampling frequency. Experimental validation is conducted on a 500 W motor operating within a speed range of 200–1000 RPM under constant load conditions at room temperature. Results show that the SRLS algorithm achieves a relative estimation error of 2.59 % for resistance and less than 5% for inductance. The proposed algorithm executes in only 26.5µs on an STM32F427 microcontroller, resulting in a 53% CPU load, which represents a 43% reduction in computational burden compared to the standard RLS method.
- 31 March 2026
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 13 (1) , 419-433
A Computationally Efficient Sequential RLS Estimator for PMSM Parameters: Algorithm Design and Experimental Verification
Accurate knowledge of electrical parameters is crucial for high-performance field oriented control (FOC) of permanent magnet synchronous motors (PMSMs). However, parameters vary significantly due to thermal effects and magnetic saturation. This study proposes a computationally efficient sequential recursive least squares (SRLS) algorithm for real-time parameter identification. Unlike conventional methods, proposed approach decouples the d- and q-axis dynamics to reduce the matrix operation complexity. Identification is achieved under persistent excitation provided by the active torque current (i_q) and the standard FOC scheme at a 20 kHz sampling frequency. Experimental validation is conducted on a 500 W motor operating within a speed range of 200–1000 RPM under constant load conditions at room temperature. Results show that the SRLS algorithm achieves a relative estimation error of 2.59 % for resistance and less than 5% for inductance. The proposed algorithm executes in only 26.5µs on an STM32F427 microcontroller, resulting in a 53% CPU load, which represents a 43% reduction in computational burden compared to the standard RLS method.
- Open Access
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 184194-184206
Third Harmonic Rejection-Based PFC Improvement for Single-Stage Flyback Converter
This study introduces a novel method for improving power factor (PF) and minimizing total harmonic distortion (THD) in single-stage critical conduction mode (CRM) flyback power factor correction (PFC) converters. The proposed approach utilizes a third harmonic rejection-based variable on-time control (THR-VOT) technique. By extracting the third harmonic component from the input voltage waveform, the method significantly enhances the sinusoidal nature of the input current, resulting in both a higher PF and a reduction in THD. The effectiveness and practical applicability of the proposed method are validated through theoretical analysis and experimental implementation on a 100 W CRM flyback PFC prototype controlled by an STM32F427 microcontroller. The experimental results reveal significant improvements in energy efficiency, verifying the method’s robustness. This control approach also stands out for its simplicity and cost-efficiency, making it a viable solution for active PFC in single-stage converters.
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 184194-184206
Open AccessThird Harmonic Rejection-Based PFC Improvement for Single-Stage Flyback Converter
This study introduces a novel method for improving power factor (PF) and minimizing total harmonic distortion (THD) in single-stage critical conduction mode (CRM) flyback power factor correction (PFC) converters. The proposed approach utilizes a third harmonic rejection-based variable on-time control (THR-VOT) technique. By extracting the third harmonic component from the input voltage waveform, the method significantly enhances the sinusoidal nature of the input current, resulting in both a higher PF and a reduction in THD. The effectiveness and practical applicability of the proposed method are validated through theoretical analysis and experimental implementation on a 100 W CRM flyback PFC prototype controlled by an STM32F427 microcontroller. The experimental results reveal significant improvements in energy efficiency, verifying the method’s robustness. This control approach also stands out for its simplicity and cost-efficiency, making it a viable solution for active PFC in single-stage converters.
- 19 August 2025
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 54 (4) , 2074-2089
Design of a Single‐Phase Quasi‐Z‐Source Asymmetric Cascaded Half‐Bridge Multilevel Inverter
In this paper, a single‐phase quasi‐z‐source asymmetric cascaded half‐bridge multilevel inverter (qZS‐ACHBMLI) is proposed, featuring a novel control scheme to achieve desired AC output voltage levels. The proposed inverter has a modular design, allowing for easy extension of output voltage levels by adding additional power modules. Unlike other multilevel inverters (MLIs), the proposed topology is designed as a half‐bridge, so it is possible to generate an AC output voltage at the desired voltage level with a minimum number of switches. This reduces the size, cost, and complexity of the circuit. Besides, the proposed control algorithm enables the generation of negative voltage levels with a half‐bridge polarity changer circuit. However, in the negative half cycle, the output voltage drops to zero as the polarity changer circuit provides a shoot‐through (ST) condition to increase the output voltage. The robustness of the proposed topology and control method is validated through experimental results obtained from a 500 W, five‐level qZS‐ACHBMLI prototype, controlled by a 32‐bit NUCLEO‐F401RE microcontroller. The experimental findings demonstrate a significant improvement in energy efficiency compared with competing topologies.
- 19 August 2025
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 54 (4) , 2074-2089
Design of a Single‐Phase Quasi‐Z‐Source Asymmetric Cascaded Half‐Bridge Multilevel Inverter
In this paper, a single‐phase quasi‐z‐source asymmetric cascaded half‐bridge multilevel inverter (qZS‐ACHBMLI) is proposed, featuring a novel control scheme to achieve desired AC output voltage levels. The proposed inverter has a modular design, allowing for easy extension of output voltage levels by adding additional power modules. Unlike other multilevel inverters (MLIs), the proposed topology is designed as a half‐bridge, so it is possible to generate an AC output voltage at the desired voltage level with a minimum number of switches. This reduces the size, cost, and complexity of the circuit. Besides, the proposed control algorithm enables the generation of negative voltage levels with a half‐bridge polarity changer circuit. However, in the negative half cycle, the output voltage drops to zero as the polarity changer circuit provides a shoot‐through (ST) condition to increase the output voltage. The robustness of the proposed topology and control method is validated through experimental results obtained from a 500 W, five‐level qZS‐ACHBMLI prototype, controlled by a 32‐bit NUCLEO‐F401RE microcontroller. The experimental findings demonstrate a significant improvement in energy efficiency compared with competing topologies.
- Open Access
- 30 September 2024
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 11 (3) , 563-576
Super Twisting Sliding Mode Control of Four-Phase Interleaved Boost Converter
This paper presents a novel control method that integrates super-twisting sliding mode (STSM) voltage control with proportional-integral (PI) current control for a four-phase interleaved boost converter (IBC) in fuel cell applications. The STSM control, employed in the outer voltage loop, provides robust voltage regulation by generating precise reference currents for each phase. The conventional PI control in the inner current loop utilizes these reference currents to generate pulse width modulation (PWM) signals for each phase. The effectiveness of the proposed control strategy is evaluated through comprehensive simulation studies in MATLAB/Simulink, demonstrating an improvement in dynamic performance and enhanced robustness compared to conventional methods. Quantitative analysis shows that the output voltage quickly rises to the reference voltage within approximately 0.25 seconds in the proposed STSM-PI control method and improves transient response by 16 times compared to the conventional PI-PI method. This integrated STSM-PI control strategy offers significant advancements in reliability and efficiency making it a promising solution for high-performance fuel cell power systems.
- 30 September 2024
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 11 (3) , 563-576
Open AccessSuper Twisting Sliding Mode Control of Four-Phase Interleaved Boost Converter
This paper presents a novel control method that integrates super-twisting sliding mode (STSM) voltage control with proportional-integral (PI) current control for a four-phase interleaved boost converter (IBC) in fuel cell applications. The STSM control, employed in the outer voltage loop, provides robust voltage regulation by generating precise reference currents for each phase. The conventional PI control in the inner current loop utilizes these reference currents to generate pulse width modulation (PWM) signals for each phase. The effectiveness of the proposed control strategy is evaluated through comprehensive simulation studies in MATLAB/Simulink, demonstrating an improvement in dynamic performance and enhanced robustness compared to conventional methods. Quantitative analysis shows that the output voltage quickly rises to the reference voltage within approximately 0.25 seconds in the proposed STSM-PI control method and improves transient response by 16 times compared to the conventional PI-PI method. This integrated STSM-PI control strategy offers significant advancements in reliability and efficiency making it a promising solution for high-performance fuel cell power systems.
- 2 February 2024
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 52 (8) , 3756-3773
Coupled inductor‐based buck power factor correction (PFC) converter with soft switching
Summary: In this study, couple inductor‐based buck power factor correction (PFC) converter is designed to mitigate dead zones of the converter. To minimize switching losses, all switches are controlled using a soft switching method, eliminating the need for snubber circuits. The circuit is controlled by an analog UC3843 pulse width modulation (PWM) integrated circuit (IC), providing natural PFC capability, which simplifies control and offers advantages in terms of size and cost compared to conventional ones. Simulation studies and prototype implementation are carried out to evaluate performance of the topology. The converter operates within a voltage range of 90–280 Vrms and has a power rating of 150 W. The results from both simulation and experimental analyses indicate that power factor (PF) of the circuit exceeds 98% and total harmonic distortion (THD) of the input current is found to be below 5% under various input voltage and load conditions. Furthermore, proposed topology demonstrated high efficiency, with measurements of 93% at full load and 95.6% at half load under 220 Vrms input voltage and 80 Vdc output voltage conditions. Outcomes highlight that the proposed topology achieves pure sinusoidal input current and exhibits competitive performance compared to other topologies used in the industry.
- 2 February 2024
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 52 (8) , 3756-3773
Coupled inductor‐based buck power factor correction (PFC) converter with soft switching
Summary: In this study, couple inductor‐based buck power factor correction (PFC) converter is designed to mitigate dead zones of the converter. To minimize switching losses, all switches are controlled using a soft switching method, eliminating the need for snubber circuits. The circuit is controlled by an analog UC3843 pulse width modulation (PWM) integrated circuit (IC), providing natural PFC capability, which simplifies control and offers advantages in terms of size and cost compared to conventional ones. Simulation studies and prototype implementation are carried out to evaluate performance of the topology. The converter operates within a voltage range of 90–280 Vrms and has a power rating of 150 W. The results from both simulation and experimental analyses indicate that power factor (PF) of the circuit exceeds 98% and total harmonic distortion (THD) of the input current is found to be below 5% under various input voltage and load conditions. Furthermore, proposed topology demonstrated high efficiency, with measurements of 93% at full load and 95.6% at half load under 220 Vrms input voltage and 80 Vdc output voltage conditions. Outcomes highlight that the proposed topology achieves pure sinusoidal input current and exhibits competitive performance compared to other topologies used in the industry.
- 28 December 2023
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 11 (4) , 1232-1243
A Comparison of Digital Constant On-Time and Variable On-Time Control in Buck/Buck-Boost PFC Converter
This study compares two frequently used control strategies in the context of completely digitally controlled critical conduction mode (CRM) buck/buck-boost converters, namely constant on-time (COT) and variable on-time (VOT). The aim of this research is to compare and assess the performance of different control systems in terms of power factor (PF) and total harmonic distortion (THD). The COT control technique employs a fixed on-time period for each switching cycle, resulting in a predictable and straightforward control scheme. On the other hand, VOT control dynamically adapts the on-time period based on the input and output voltage conditions, offering potential advantages in terms of load regulation and stability. The analysis results provide valuable insights into the strengths and limitations of each control technique. Additionally, the dynamic behavior of the converters under various operating conditions is investigated, shedding light on the stability and robustness aspects of each control scheme. The study is conducted using a fully digital setup and evaluated in Matlab/Simulink environment. The findings show that VOT control outperforms COT in terms of THD and PF under steady-state conditions. These findings offer valuable guidance for selecting the appropriate control technique for PFC converters, depending on specific requirements of their applications.
- 28 December 2023
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 11 (4) , 1232-1243
A Comparison of Digital Constant On-Time and Variable On-Time Control in Buck/Buck-Boost PFC Converter
This study compares two frequently used control strategies in the context of completely digitally controlled critical conduction mode (CRM) buck/buck-boost converters, namely constant on-time (COT) and variable on-time (VOT). The aim of this research is to compare and assess the performance of different control systems in terms of power factor (PF) and total harmonic distortion (THD). The COT control technique employs a fixed on-time period for each switching cycle, resulting in a predictable and straightforward control scheme. On the other hand, VOT control dynamically adapts the on-time period based on the input and output voltage conditions, offering potential advantages in terms of load regulation and stability. The analysis results provide valuable insights into the strengths and limitations of each control technique. Additionally, the dynamic behavior of the converters under various operating conditions is investigated, shedding light on the stability and robustness aspects of each control scheme. The study is conducted using a fully digital setup and evaluated in Matlab/Simulink environment. The findings show that VOT control outperforms COT in terms of THD and PF under steady-state conditions. These findings offer valuable guidance for selecting the appropriate control technique for PFC converters, depending on specific requirements of their applications.
- 29 September 2023
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 10 (3) , 286-300
Genetic Algorithm based PID Tuning Software Design and Implementation for a DC Motor Control System
This study presents the software and implementation for proportional-integral-derivative (PID) tuning of a DC motor control system using genetic algorithm (GA). The PID parameters for a specific control structure are optimized using GA in the proposed tuning procedure. Also, integral time absolute error (ITAE) is used as a fitness function to optimize the parameters. The robustness of the control system is compared with conventional mathematical method. Simulations are carried out in MATLAB/Simulink to compare the results of a DC motor control system. Simulation results show that in terms of overshoot, steady-state error, and settling time, GA-based PID tuning approach performed better than conventional method. Additionally, a sensitivity analysis is performed to evaluate how robust the proposed approach is to parameter variations. The analysis shows that compared to the conventional method, the GA-based PID tuning algorithm is more adaptable to variations in system parameters.
- 29 September 2023
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 10 (3) , 286-300
Genetic Algorithm based PID Tuning Software Design and Implementation for a DC Motor Control System
This study presents the software and implementation for proportional-integral-derivative (PID) tuning of a DC motor control system using genetic algorithm (GA). The PID parameters for a specific control structure are optimized using GA in the proposed tuning procedure. Also, integral time absolute error (ITAE) is used as a fitness function to optimize the parameters. The robustness of the control system is compared with conventional mathematical method. Simulations are carried out in MATLAB/Simulink to compare the results of a DC motor control system. Simulation results show that in terms of overshoot, steady-state error, and settling time, GA-based PID tuning approach performed better than conventional method. Additionally, a sensitivity analysis is performed to evaluate how robust the proposed approach is to parameter variations. The analysis shows that compared to the conventional method, the GA-based PID tuning algorithm is more adaptable to variations in system parameters.
- Open Access
- 27 June 2023
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 10 (2) , 206-221
A Control Scheme for a Quasi-Z Source Three-Phase Inverter
This paper presents a novel control scheme for a three-phase quasi-z source inverter (qZSI) using a capacitor voltage and input current-based sinusoidal pulse width modulation (SPWM) technique. The proposed scheme combines the advantages of both qZSI and SPWM techniques to achieve improved performance. The SPWM technique utilizes a sinusoidal modulation signal, which is compared with a high-frequency triangular carrier wave and two shoot-through (ST) references to determine the switching states for the three-phase qZSI. The positive and negative ST references are obtained from the capacitor voltages and input current, allowing for control of the DC bus voltage and ST states of the inverter. Additionally, the proposed control scheme generates the three-phase modulation signal through decoupling control in the dq reference frame. The detailed analysis of the control scheme includes its operating principle, transient state, steady-state responses, and the effects of parameter variations. Simulation studies are conducted using MATLAB/Simulink to assess the performance of the three-phase qZSI under the proposed control scheme. The simulation results demonstrate the effectiveness of the control scheme in terms of output voltage quality, DC bus voltage control, and robustness against reference variations. Overall, the proposed capacitor voltage and input current-based SPWM control scheme for the three-phase qZSI shows promising performance improvements and robustness, as confirmed through comprehensive simulation studies.
- 27 June 2023
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 10 (2) , 206-221
Open AccessA Control Scheme for a Quasi-Z Source Three-Phase Inverter
This paper presents a novel control scheme for a three-phase quasi-z source inverter (qZSI) using a capacitor voltage and input current-based sinusoidal pulse width modulation (SPWM) technique. The proposed scheme combines the advantages of both qZSI and SPWM techniques to achieve improved performance. The SPWM technique utilizes a sinusoidal modulation signal, which is compared with a high-frequency triangular carrier wave and two shoot-through (ST) references to determine the switching states for the three-phase qZSI. The positive and negative ST references are obtained from the capacitor voltages and input current, allowing for control of the DC bus voltage and ST states of the inverter. Additionally, the proposed control scheme generates the three-phase modulation signal through decoupling control in the dq reference frame. The detailed analysis of the control scheme includes its operating principle, transient state, steady-state responses, and the effects of parameter variations. Simulation studies are conducted using MATLAB/Simulink to assess the performance of the three-phase qZSI under the proposed control scheme. The simulation results demonstrate the effectiveness of the control scheme in terms of output voltage quality, DC bus voltage control, and robustness against reference variations. Overall, the proposed capacitor voltage and input current-based SPWM control scheme for the three-phase qZSI shows promising performance improvements and robustness, as confirmed through comprehensive simulation studies.
- Open Access
- 23 June 2023
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 11 (2) , 464-474
The Implementation of Internal Mode Control Method to SEPIC Converter for Battery Charging Systems
In this paper, internal model control (IMC) method, which is a model-based approach that offers more robust and better reference tracking capability than conventional controllers for the unstable process, is applied to the SEPIC converter used in battery charging system for military applications. When a system is not based on a plant model, it is possible to encounter some problems such as dead time and non-linearity in controlling of the system. The purpose of the SEPIC topology is to eliminate the disadvantage of other topologies such as Buck-Boost and Cúk converters that are used for similar applications in reversing the output voltage. In addition, a great amount of voltage and current stress on a component causes the power board to overheat in such converters and requires additional cooling equipment. These problems are not encountered in SEPIC topology. Also, this topology provides high efficiency, step-up/step-down voltage conversion, and excellent transient state response over a wide range. The performance of IMC method applied on SEPIC converter is detailed analyzed in terms of simulation studies that are obtained by using MATLAB/Simulink and experimental studies.
- 23 June 2023
- Published by Gazi Universitesi Fen Bilimleri Dergisi Part C: Tasarim ve Teknoloji in Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji
- Vol. 11 (2) , 464-474
Open AccessThe Implementation of Internal Mode Control Method to SEPIC Converter for Battery Charging Systems
In this paper, internal model control (IMC) method, which is a model-based approach that offers more robust and better reference tracking capability than conventional controllers for the unstable process, is applied to the SEPIC converter used in battery charging system for military applications. When a system is not based on a plant model, it is possible to encounter some problems such as dead time and non-linearity in controlling of the system. The purpose of the SEPIC topology is to eliminate the disadvantage of other topologies such as Buck-Boost and Cúk converters that are used for similar applications in reversing the output voltage. In addition, a great amount of voltage and current stress on a component causes the power board to overheat in such converters and requires additional cooling equipment. These problems are not encountered in SEPIC topology. Also, this topology provides high efficiency, step-up/step-down voltage conversion, and excellent transient state response over a wide range. The performance of IMC method applied on SEPIC converter is detailed analyzed in terms of simulation studies that are obtained by using MATLAB/Simulink and experimental studies.