Guillaume Morel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Guillaume Morel has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Florian Richer
CNRS UMR7222, INSERM U1150, Institute of Intelligent Systems and Robotics, Sorbonne Universit, Paris, France
3 shared publications- Marie-Aude Vitrani
UMR 7222, ISIR, Sorbonne Universités UPMC Univ. Paris 06, Paris, France.
3 shared publications - Nathanaël Jarrassé
CNRS, INSERM, Institute for Intelligent Systems and Robotics (ISIR), Sorbonne Université, Paris, France
3 shared publications - A. Harlé
ISIR, UMR 7222 Sorbonne University, CNRS, U1150 INSERM, Paris, France
2 shared publications - Brahim Tamadazte
Institut des Systèmes Intelligents et de Robotique (ISIR)
2 shared publications - Elie Saghbiny
Sorbonne University - Armand Trousseau Hospital, AP-HP, 26 avenue du Docteur-Arnold-Netter, 75012 Paris, France
2 shared publications
Latest Publications
- 11 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 1084-1092
Breach Detection in Spine Surgery Based on Cutting Torque
The accurate placement of pedicle screws is crucial for various spinal interventions, demanding precise geometric alignment while carrying inherent risks. Studies show that the rate of complications can reach up to 18% in case of imprecise placement of pedicle screws. To enhance the precision and safety of pedicle screw placement, we have developed a robotic system equipped with several sensors and paired with a breach detection algorithm capable of identifying potential breaches in the spinal canal. The breach detection algorithm was conceptualized through an analysis of the cutting torque of the drill system. An ex-vivo experiment was conducted to assess the effectiveness of the developed robotic solution and breach detection algorithm. The data (e.g., cutting torque, position, velocity, etc.) used during the validation were collected by drilling 80 pedicles in fresh porcine vertebrae. The results demonstrated that the proposed algorithm could predict breaches in 96.42% of cases, i.e., the distance between the detected point (drilling stop) and the point of the breach is within 2 mm. In a single instance, the detection occurred earlier than anticipated due to the trajectory being oriented significantly medially, resulting in an initial interaction with the cortical bone at an earlier point.
- 11 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 1084-1092
Breach Detection in Spine Surgery Based on Cutting Torque
The accurate placement of pedicle screws is crucial for various spinal interventions, demanding precise geometric alignment while carrying inherent risks. Studies show that the rate of complications can reach up to 18% in case of imprecise placement of pedicle screws. To enhance the precision and safety of pedicle screw placement, we have developed a robotic system equipped with several sensors and paired with a breach detection algorithm capable of identifying potential breaches in the spinal canal. The breach detection algorithm was conceptualized through an analysis of the cutting torque of the drill system. An ex-vivo experiment was conducted to assess the effectiveness of the developed robotic solution and breach detection algorithm. The data (e.g., cutting torque, position, velocity, etc.) used during the validation were collected by drilling 80 pedicles in fresh porcine vertebrae. The results demonstrated that the proposed algorithm could predict breaches in 96.42% of cases, i.e., the distance between the detected point (drilling stop) and the point of the breach is within 2 mm. In a single instance, the detection occurred earlier than anticipated due to the trajectory being oriented significantly medially, resulting in an initial interaction with the cortical bone at an earlier point.
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (2) , 1915-1922
Automatic Spinal Canal Breach Detection During Pedicle Screw Placement
Precise pedicle screw placement is imperative for a range of spinal procedures demanding exact geometric alignment while also carrying inherent risks. The literature reports a complication rate in the case of screw mispositioning of up to 18%. To increase the accuracy of pedicle screw placement, we developed a robotic setup and a breach detection algorithm that could detect a possible perforation of the spinal canal. The robotic setup includes a robotic arm, a drilling system, and specific sensors, e.g., electrical conductivity at the drill bit's tip. The breach detection algorithm consists of a Bayesian-based method providing online and real-time analysis of the electrical conductivity signal to predict a breach. The robotic setup and the perforation detection algorithm were assessed in two ex-vivo experiments. First, data collection was performed by drilling 80 fresh pig vertebrae pedicles, followed by precise data labeling by a surgeon. The evaluation of the proposed algorithm was conducted numerically. Finally, the assessment was performed online by automatically drilling into pedicles in conditions similar to the operating room. The results demonstrated that the algorithm could predict perforations and prevent the robotic setup from going through in 100% of 24 drilled vertebrae. Results demonstrate that using electrical conductivity combined with a robotic setup allows the detection of imminent perforations of the spinal canal during pedicle drilling. This was the first study to evaluate spinal canal perforation detection during ex-vivo pig pedicle drilling.
- 4 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (2) , 1915-1922
Automatic Spinal Canal Breach Detection During Pedicle Screw Placement
Precise pedicle screw placement is imperative for a range of spinal procedures demanding exact geometric alignment while also carrying inherent risks. The literature reports a complication rate in the case of screw mispositioning of up to 18%. To increase the accuracy of pedicle screw placement, we developed a robotic setup and a breach detection algorithm that could detect a possible perforation of the spinal canal. The robotic setup includes a robotic arm, a drilling system, and specific sensors, e.g., electrical conductivity at the drill bit's tip. The breach detection algorithm consists of a Bayesian-based method providing online and real-time analysis of the electrical conductivity signal to predict a breach. The robotic setup and the perforation detection algorithm were assessed in two ex-vivo experiments. First, data collection was performed by drilling 80 fresh pig vertebrae pedicles, followed by precise data labeling by a surgeon. The evaluation of the proposed algorithm was conducted numerically. Finally, the assessment was performed online by automatically drilling into pedicles in conditions similar to the operating room. The results demonstrated that the algorithm could predict perforations and prevent the robotic setup from going through in 100% of 24 drilled vertebrae. Results demonstrate that using electrical conductivity combined with a robotic setup allows the detection of imminent perforations of the spinal canal during pedicle drilling. This was the first study to evaluate spinal canal perforation detection during ex-vivo pig pedicle drilling.
- Open Access
- 24 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 1745-1754
Simultaneous Control of 2DOF Upper-Limb Prosthesis With Body Compensations-Based Control: A Multiple Cases Study
Controlling several joints simultaneously is a common feature of natural arm movements. Robotic prostheses shall offer this possibility to their wearer. Yet, existing approaches to control a robotic upper-limb prosthesis from myoelectric interfaces do not satisfactorily respond to this need: standard methods provide sequential joint-by-joint motion control only; advanced pattern recognition-based approaches allow the control of a limited subset of synchronized multi-joint movements and remain complex to set up. In this paper, we exploit a control method of an upper-limb prosthesis based on body motion measurement called Compensations Cancellation Control (CCC). It offers a straightforward simultaneous control of the intermediate joints, namely the wrist and the elbow. Four transhumeral amputated participants performed the Refined Rolyan Clothespin Test with an experimental prosthesis alternatively running CCC and conventional joint-by-joint myoelectric control. Task performance, joint motions, body compensations and cognitive load were assessed. This experiment shows that CCC restores simultaneity between prosthetic joints while maintaining the level of performance of conventional myoelectric control (used on a daily basis by three participants), without increasing compensatory motions nor cognitive load.
- 24 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 1745-1754
Open AccessSimultaneous Control of 2DOF Upper-Limb Prosthesis With Body Compensations-Based Control: A Multiple Cases Study
Controlling several joints simultaneously is a common feature of natural arm movements. Robotic prostheses shall offer this possibility to their wearer. Yet, existing approaches to control a robotic upper-limb prosthesis from myoelectric interfaces do not satisfactorily respond to this need: standard methods provide sequential joint-by-joint motion control only; advanced pattern recognition-based approaches allow the control of a limited subset of synchronized multi-joint movements and remain complex to set up. In this paper, we exploit a control method of an upper-limb prosthesis based on body motion measurement called Compensations Cancellation Control (CCC). It offers a straightforward simultaneous control of the intermediate joints, namely the wrist and the elbow. Four transhumeral amputated participants performed the Refined Rolyan Clothespin Test with an experimental prosthesis alternatively running CCC and conventional joint-by-joint myoelectric control. Task performance, joint motions, body compensations and cognitive load were assessed. This experiment shows that CCC restores simultaneity between prosthetic joints while maintaining the level of performance of conventional myoelectric control (used on a daily basis by three participants), without increasing compensatory motions nor cognitive load.
- Open Access
- 30 May 2022
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 18 (5) , e2416
The stability investigation of variable viscosity control in the human‐robot interaction
Background: For many co‐manipulative applications, variable damping is a valuable feature provided by robots. One approach is implementing a high viscosity at low velocities and a low viscosity at high velocities. This, however, is proven to have the possibility to alter human natural motion performance.Methods: We show that the distortion is caused by the viscosity drop resulting in robot's resistance to motion. To address this, a method for stably achieving the desired behaviour is presented. It involves leveraging a first‐order linear filter to slow the viscosity variation down.Results: The proposition is supported by a theoretical analysis using a robotic model. Meanwhile, the user performance in human‐robot experiments gets significantly improved, showing the practical efficiency in real applications.Conclusions: This paper discusses the variable viscosity control in the context of co‐manipulation. An instability problem and its solution were theoretically shown and experimentally evidenced through human‐robot experiments.
- 30 May 2022
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 18 (5) , e2416
Open AccessThe stability investigation of variable viscosity control in the human‐robot interaction
Background: For many co‐manipulative applications, variable damping is a valuable feature provided by robots. One approach is implementing a high viscosity at low velocities and a low viscosity at high velocities. This, however, is proven to have the possibility to alter human natural motion performance.Methods: We show that the distortion is caused by the viscosity drop resulting in robot's resistance to motion. To address this, a method for stably achieving the desired behaviour is presented. It involves leveraging a first‐order linear filter to slow the viscosity variation down.Results: The proposition is supported by a theoretical analysis using a robotic model. Meanwhile, the user performance in human‐robot experiments gets significantly improved, showing the practical efficiency in real applications.Conclusions: This paper discusses the variable viscosity control in the context of co‐manipulation. An instability problem and its solution were theoretically shown and experimentally evidenced through human‐robot experiments.
- 30 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (1) , 230-240
Closing the Loop Between Body Compensations and Upper Limb Prosthetic Movements: A Feasibility Study
To control the robotic joints of an upper limb prosthesis, most existing approaches rely on decoding the user motor intention from electrophysiological signals produced by the subject, and then executing the desired movement. This suffers from important limitations and requires extended training, particularly when a large number of prosthetic joints have to be controlled. Even when they master the control of their prosthesis, many amputees underuse the prosthetic mobility to the benefit of compensatory body movements, whose generation is less expensive and more natural from a cognitive point of view. Indeed, with an arm prosthesis, hand movements result from a combination of human and robotic joint motions. We propose in this article to use these compensatory motions as an error signal to servo the robotic controller. This approach thus creates a coupling between body compensations and prosthetic movements. To study the feasibility of such a coupling, the concept is tested with ten able-bodied subjects wearing an emulated elbow prosthesis and one congenital arm amputee. The results validate the concept, which allows naive subjects to control the prosthetic joint with no or very short training period.
- 30 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (1) , 230-240
Closing the Loop Between Body Compensations and Upper Limb Prosthetic Movements: A Feasibility Study
To control the robotic joints of an upper limb prosthesis, most existing approaches rely on decoding the user motor intention from electrophysiological signals produced by the subject, and then executing the desired movement. This suffers from important limitations and requires extended training, particularly when a large number of prosthetic joints have to be controlled. Even when they master the control of their prosthesis, many amputees underuse the prosthetic mobility to the benefit of compensatory body movements, whose generation is less expensive and more natural from a cognitive point of view. Indeed, with an arm prosthesis, hand movements result from a combination of human and robotic joint motions. We propose in this article to use these compensatory motions as an error signal to servo the robotic controller. This approach thus creates a coupling between body compensations and prosthetic movements. To study the feasibility of such a coupling, the concept is tested with ten able-bodied subjects wearing an emulated elbow prosthesis and one congenital arm amputee. The results validate the concept, which allows naive subjects to control the prosthetic joint with no or very short training period.
- 19 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 2 (2) , 236-247
Using Generic Upper-Body Movement Strategies in a Free Walking Setting to Detect Gait Initiation Intention in a Lower-Limb Exoskeleton
In recent years, lower-limb exoskeletons have been marketed to become a possible alternative to wheelchairs for people with walking impairments or paralysis. However, most assistive exoskeletons rely on constraining control strategies based on remote controls or torso tilting events. One approach to build more intuitive control interfaces would be to exploit knowledge on human motor control, and the coordination between upper and lower limb movements during gait events, such as the anticipatory postural adjustments that precede gait initiation. In this study, it was hypothesized that generic trunk and arm movements preceding gait in a free walking setting in able-bodied users can still be retrieved while wearing an assistive lower-limb exoskeleton that constrains their leg movements. This was evaluated on a group of eight unimpaired participants, and analysis of upper-body wearable IMU signals showed similarity of postural adjustments between the free and exoskeleton-constrained settings. Additionally, a classification architecture showed that the walking state of the robot can be correctly triggered based on free-walking data gathered from all participants with an accuracy rate of 95%. This suggests that interlimb coordination still exists in a constrained setting, and could pave the road towards the elaboration of more natural controls for assistive lower-limb exoskeletons.
- 19 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 2 (2) , 236-247
Using Generic Upper-Body Movement Strategies in a Free Walking Setting to Detect Gait Initiation Intention in a Lower-Limb Exoskeleton
In recent years, lower-limb exoskeletons have been marketed to become a possible alternative to wheelchairs for people with walking impairments or paralysis. However, most assistive exoskeletons rely on constraining control strategies based on remote controls or torso tilting events. One approach to build more intuitive control interfaces would be to exploit knowledge on human motor control, and the coordination between upper and lower limb movements during gait events, such as the anticipatory postural adjustments that precede gait initiation. In this study, it was hypothesized that generic trunk and arm movements preceding gait in a free walking setting in able-bodied users can still be retrieved while wearing an assistive lower-limb exoskeleton that constrains their leg movements. This was evaluated on a group of eight unimpaired participants, and analysis of upper-body wearable IMU signals showed similarity of postural adjustments between the free and exoskeleton-constrained settings. Additionally, a classification architecture showed that the walking state of the robot can be correctly triggered based on free-walking data gathered from all participants with an accuracy rate of 95%. This suggests that interlimb coordination still exists in a constrained setting, and could pave the road towards the elaboration of more natural controls for assistive lower-limb exoskeletons.
- 27 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 3 (3) , 2071-2078
Leveraging the Fulcrum Point in Robotic Minimally Invasive Surgery
In robotic minimally invasive surgery, the incision point acts as a fulcrum around which the surgical instrument pivots. The fulcrum point has been the topic of much research. Mechanisms have been invented to enforce instrument motion about such a fulcrum. Other systems establish a fulcrum through coordinated control of their joints. For laparoscopists, the fulcrum point is an obstacle to overcome through a lot of training. For robots, it is a hurdle requiring careful consideration. In this letter, new estimation methods are proposed to exploit the properties of a fulcrum and turn its presence into an advantage. This letter starts by presenting a novel fulcrum estimation method that is robust against measurement noise and quantization effects. A general fulcrum refinement method is proposed next. This method can be used as add-on to ameliorate alternative estimation approaches. It is shown how the fulcrum can also be leveraged to get accurate, high-bandwidth estimates of the instrument tip. The quality with which the instrument tip is estimated has a large impact on the performance of advanced guidance schemes, such as haptic virtual walls. User tests are included, demonstrating substantially improved guidance thanks to the algorithms presented in this work.
- 27 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 3 (3) , 2071-2078
Leveraging the Fulcrum Point in Robotic Minimally Invasive Surgery
In robotic minimally invasive surgery, the incision point acts as a fulcrum around which the surgical instrument pivots. The fulcrum point has been the topic of much research. Mechanisms have been invented to enforce instrument motion about such a fulcrum. Other systems establish a fulcrum through coordinated control of their joints. For laparoscopists, the fulcrum point is an obstacle to overcome through a lot of training. For robots, it is a hurdle requiring careful consideration. In this letter, new estimation methods are proposed to exploit the properties of a fulcrum and turn its presence into an advantage. This letter starts by presenting a novel fulcrum estimation method that is robust against measurement noise and quantization effects. A general fulcrum refinement method is proposed next. This method can be used as add-on to ameliorate alternative estimation approaches. It is shown how the fulcrum can also be leveraged to get accurate, high-bandwidth estimates of the instrument tip. The quality with which the instrument tip is estimated has a large impact on the performance of advanced guidance schemes, such as haptic virtual walls. User tests are included, demonstrating substantially improved guidance thanks to the algorithms presented in this work.
- 29 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 33 (1) , 114-123
Applying Virtual Fixtures to the Distal End of a Minimally Invasive Surgery Instrument
The comanipulation paradigm, in which a user and a robot simultaneously hold a tool, allows for gesture guidance. In particular, virtual fixtures, which are geometrical constraints imposed to the tool by the robot, have received great interest in the domain of surgical applications. So far, this concept has been implemented in the context of open surgery. This paper explores the application of virtual fixtures for minimally invasive surgery, in which the tool is inserted in the patient through a fulcrum. Here, a key issue is to return to the surgeon forces that are virtually applied at the instrument distal tip, while the robot is physically attached to the instrument proximal handle. To this aim, two approaches are investigated. A first approach consists of applying a full wrench at the proximal end of the instrument that is equal to the wrench constituted by a pure force applied to the instrument's distal tip. A second approach consists of applying a pure force to the instrument proximal end, thanks to a lever model about the fulcrum. The two approaches are compared through experiments, during which naive subjects blindly perform virtual object palpation and robot-guided movements. During experiments, indicators involving motion and force analysis are computed. The user capacity to distinguish between several virtual objects is evaluated as well. Although drastically different, the two approaches provide assistance with a similar level of efficiency.
- 29 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 33 (1) , 114-123
Applying Virtual Fixtures to the Distal End of a Minimally Invasive Surgery Instrument
The comanipulation paradigm, in which a user and a robot simultaneously hold a tool, allows for gesture guidance. In particular, virtual fixtures, which are geometrical constraints imposed to the tool by the robot, have received great interest in the domain of surgical applications. So far, this concept has been implemented in the context of open surgery. This paper explores the application of virtual fixtures for minimally invasive surgery, in which the tool is inserted in the patient through a fulcrum. Here, a key issue is to return to the surgeon forces that are virtually applied at the instrument distal tip, while the robot is physically attached to the instrument proximal handle. To this aim, two approaches are investigated. A first approach consists of applying a full wrench at the proximal end of the instrument that is equal to the wrench constituted by a pure force applied to the instrument's distal tip. A second approach consists of applying a pure force to the instrument proximal end, thanks to a lever model about the fulcrum. The two approaches are compared through experiments, during which naive subjects blindly perform virtual object palpation and robot-guided movements. During experiments, indicators involving motion and force analysis are computed. The user capacity to distinguish between several virtual objects is evaluated as well. Although drastically different, the two approaches provide assistance with a similar level of efficiency.
- 12 April 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (6) , 1153-1161
Prostate biopsies assisted by comanipulated probe-holder: first in man
A comanipulator for assisting endorectal prostate biopsies is evaluated through a first-in-man clinical trial. This lightweight system, based on conventional robotic components, possesses six degrees of freedom. It uses three electric motors and three brakes. It features a free mode, where its low friction and inertia allow for natural manipulation of the probe and a locked mode, exhibiting both a very low stiffness and a high steady-state precision. Clinical trials focusing on the free mode and the locked mode of the robot are presented. The objective was to evaluate the practical usability and performance of the robot during clinical procedures. A research protocol for a prospective randomized clinical trial has been designed. Its specific goal was to compare the accuracy of biopsies performed with and without the assistance of the comanipulator. The accuracy is compared between biopsies performed with and without the assistance of the comanipulator, across the 10 first patients included in the trial. Results show a statistically significant increase in the precision.
- 12 April 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (6) , 1153-1161
Prostate biopsies assisted by comanipulated probe-holder: first in man
A comanipulator for assisting endorectal prostate biopsies is evaluated through a first-in-man clinical trial. This lightweight system, based on conventional robotic components, possesses six degrees of freedom. It uses three electric motors and three brakes. It features a free mode, where its low friction and inertia allow for natural manipulation of the probe and a locked mode, exhibiting both a very low stiffness and a high steady-state precision. Clinical trials focusing on the free mode and the locked mode of the robot are presented. The objective was to evaluate the practical usability and performance of the robot during clinical procedures. A research protocol for a prospective randomized clinical trial has been designed. Its specific goal was to compare the accuracy of biopsies performed with and without the assistance of the comanipulator. The accuracy is compared between biopsies performed with and without the assistance of the comanipulator, across the 10 first patients included in the trial. Results show a statistically significant increase in the precision.
- 25 June 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 10 (12) , 1893-1903
Robot guidance of an ultrasound probe toward a 3D region of interest detected through X-ray mammography
International audiencePurpose: This research is situated in the context of breast cancer detection where the standard procedure is the succession of an initial mammography (MX) examination and a supplementary Ultrasound (US) scan. One major difficulty of this procedure results from the fact that breast geometry changes between both examinations due to different patient's positions. The proposed system facilitates this combined examination by keeping the breast geometry and by adding a US probe guidance robot to the mammography system. Methods: A co-manipulation system is set up where the robot and user simultaneously manipulate the probe towards the target previously localized in MX images. Calibration procedures and robot control are detailed. Results: A test protocol was presented to conduct two tests that are both related to the medical application. The first tests aims at evaluating robot guidance for localizing a lesion which was previously defined in the X-ray images. The second tests aims at quantifying robot influence when scanning a target lesion. The studied task consists of a pointing/scanning exercise, where the US beam intersects a breast lesion. Conclusions: The experiments show a significant increase in examination quality when using robot guidance as compared to the non-assisted examination
- 25 June 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 10 (12) , 1893-1903
Robot guidance of an ultrasound probe toward a 3D region of interest detected through X-ray mammography
International audiencePurpose: This research is situated in the context of breast cancer detection where the standard procedure is the succession of an initial mammography (MX) examination and a supplementary Ultrasound (US) scan. One major difficulty of this procedure results from the fact that breast geometry changes between both examinations due to different patient's positions. The proposed system facilitates this combined examination by keeping the breast geometry and by adding a US probe guidance robot to the mammography system. Methods: A co-manipulation system is set up where the robot and user simultaneously manipulate the probe towards the target previously localized in MX images. Calibration procedures and robot control are detailed. Results: A test protocol was presented to conduct two tests that are both related to the medical application. The first tests aims at evaluating robot guidance for localizing a lesion which was previously defined in the X-ray images. The second tests aims at quantifying robot influence when scanning a target lesion. The studied task consists of a pointing/scanning exercise, where the US beam intersects a breast lesion. Conclusions: The experiments show a significant increase in examination quality when using robot guidance as compared to the non-assisted examination