Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Elie Saghbiny has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Approche multimodale pour sécuriser le placement des vis pédiculaires

    by Elie Saghbiny

    Introduction : La pose de vis pédiculaires est une étape critique en chirurgie rachidienne, en particulier dans le traitement des scolioses sévères. Malgré l'évolution des techniques d'imagerie et de navigation, le risque de brèche corticale et de complications neurologiques persiste. Cette thèse s'inscrit dans le projet européen FAROS et propose une approche multimodale de sécurisation, combinant des signaux biomécaniques et des algorithmes de détection, afin d'augmenter la précision et la sécurité du geste opératoire. Matériels et Méthodes : Des expérimentations ont été réalisées à l'ISIR (Sorbonne Université) en collaboration avec l'AP-HP et plusieurs partenaires européens. Deux modalités de détection de brèches ont été étudiées : le couple de perçage (torque) et la conductivité électrique, mesurés en temps réel pendant des forages effectués sur des vertèbres porcines (ex vivo et in vivo). Un bras robotique (KUKA LBR Med) a été utilisé pour standardiser les trajectoires de forage. Plusieurs algorithmes ont été développés pour analyser les signaux, dont un algorithme bayésien breveté. Des tests de recalage par palpation (manuelle et automatique) ont également été menés pour estimer les points d'entrée sans imagerie peropératoire. Résultats : L'analyse du couple a permis de détecter des brèches de manière anticipée dans 38,75 % des cas avec une précision moyenne de 2,14 mm. L'utilisation du signal de conductivité électrique a donné un taux de détection anticipée de 25 %, avec une précision moyenne de 0,59 mm. En combinant les deux signaux, la performance globale s'est améliorée avec un taux de détection supérieur à 70 % et une réduction significative des faux positifs. Le recalage par palpation a permis un positionnement précis avec une erreur inférieure à 1,5 mm dans la majorité des cas. Les expériences in vivo ont confirmé la faisabilité de la méthode, y compris en présence des mouvements respiratoires simulés. Discussion et Conclusion : L'approche multimodale proposée améliore la détection précoce des brèches lors du vissage pédiculaire et offre une alternative prometteuse aux systèmes de navigation par imagerie, notamment dans les contextes où l'exposition aux rayonnements doit être minimisée. L'intégration de signaux mécaniques et électriques, associée à des algorithmes d'analyse temps réel, permet une assistance robotique intelligente et sécurisée. La combinaison de détection et de recalage sans image ouvre des perspectives vers une chirurgie autonome plus fiable. Les résultats expérimentaux valident la pertinence de cette stratégie, qui pourrait être étendue à d'autres champs de la chirurgie orthopédique.

  • Open Access

    Do Patient-Specific Guides accurately correct lower limb deformities in children? Preliminary outcomes

    by Virginie Nguyen-Khac, Anne-Laure Simon, Brice Ilharreborde, Laurent Gajny, Franck Fitoussi, Alexandra Alves, Raphael Vialle, Elie Saghbini, Manon Bachy


  • Injury epidemiology related to personal mobility devices in the pediatric population

    by Lorie Bellity, Alain Masquelet, Elie Saghbini, Helena Guerra, Romain Guedj, Frank Fitoussi


  • Breach Detection in Spine Surgery Based on Cutting Torque

    by E. Saghbiny, L. Leblanc, A. Harlé, C. Bobbio, R. Vialle, G. Morel, B. Tamadazte

    The accurate placement of pedicle screws is crucial for various spinal interventions, demanding precise geometric alignment while carrying inherent risks. Studies show that the rate of complications can reach up to 18% in case of imprecise placement of pedicle screws. To enhance the precision and safety of pedicle screw placement, we have developed a robotic system equipped with several sensors and paired with a breach detection algorithm capable of identifying potential breaches in the spinal canal. The breach detection algorithm was conceptualized through an analysis of the cutting torque of the drill system. An ex-vivo experiment was conducted to assess the effectiveness of the developed robotic solution and breach detection algorithm. The data (e.g., cutting torque, position, velocity, etc.) used during the validation were collected by drilling 80 pedicles in fresh porcine vertebrae. The results demonstrated that the proposed algorithm could predict breaches in 96.42% of cases, i.e., the distance between the detected point (drilling stop) and the point of the breach is within 2 mm. In a single instance, the detection occurred earlier than anticipated due to the trajectory being oriented significantly medially, resulting in an initial interaction with the cortical bone at an earlier point.


  • Digital vs Conventional OSCE in Orthopedic Surgery: A Feasibility Cross-Sectional Study

    by Tristan Langlais, Raphaël Pietton, Adeline Cambon-Binder, Fleur Cohen, Raphaël Vialle, Elie Saghbiny, Manon Bachy, Laura Marie-Hardy

  • Automatic Spinal Canal Breach Detection During Pedicle Screw Placement

    by L. Leblanc, E. Saghbini, J. Da Silva, A. Harlé, S. Vafadar, T. Chandanson, R. Vialle, G. Morel, B. Tamadazte

    Precise pedicle screw placement is imperative for a range of spinal procedures demanding exact geometric alignment while also carrying inherent risks. The literature reports a complication rate in the case of screw mispositioning of up to 18%. To increase the accuracy of pedicle screw placement, we developed a robotic setup and a breach detection algorithm that could detect a possible perforation of the spinal canal. The robotic setup includes a robotic arm, a drilling system, and specific sensors, e.g., electrical conductivity at the drill bit's tip. The breach detection algorithm consists of a Bayesian-based method providing online and real-time analysis of the electrical conductivity signal to predict a breach. The robotic setup and the perforation detection algorithm were assessed in two ex-vivo experiments. First, data collection was performed by drilling 80 fresh pig vertebrae pedicles, followed by precise data labeling by a surgeon. The evaluation of the proposed algorithm was conducted numerically. Finally, the assessment was performed online by automatically drilling into pedicles in conditions similar to the operating room. The results demonstrated that the algorithm could predict perforations and prevent the robotic setup from going through in 100% of 24 drilled vertebrae. Results demonstrate that using electrical conductivity combined with a robotic setup allows the detection of imminent perforations of the spinal canal during pedicle drilling. This was the first study to evaluate spinal canal perforation detection during ex-vivo pig pedicle drilling.


  • Open Access

    Protocol for Electrical Conductivity Signal Collection and Processing in Scoliosis Surgery

    by Elie Saghbiny, Jimmy Da Silva, Celia Chaimi, Thibault Chandanson, Raphael Vialle

    Introduction. Pedicle screw placement is a common procedure in spinal surgery. The misplacement rate with lateral and medial cortical perforation is 511. Several techniques are used to decrease this rate. Many studies proved that electrical conductivity increases accuracy during pedicle screw placement but no study has interpreted conductivity values. Methods. The data are collected from patients operated for scoliosis in a single university hospital. After the posterior surgical approach is made, each pedicle is prepared classically. Instead of the classic curved pedicle probe, the surgeon uses a probe with the same shape that measures the conductivity at its tip. Conductivity values are recorded through a Bluetooth application. Each pedicle trajectory is then qualified after manual palpation with a feeler. A trajectory is qualified as optimal when palpation shows a bone tunnel without any breach, breached when there was a breach, and a modification of the probe direction was needed. A trajectory that does not meet the abovementioned definitions is excluded from the statistical analysis. Results. 21 patients with 457 pedicles are recorded. The average age of the population is 14.71±1.86years. 17 patients (81) have idiopathic adolescent scoliosis. One patient has Rett syndrome, one has hypotonia, one has cerebral palsy, and one has congenital malformation. The depth of the instrument is measured semiautomatically. This technique is validated when compared with the manual technique using the BlandAltman agreement method (mean differences=0.279mm, upper limit=2.2mm, and lower limit=2.7mm) and Deming regression (slope=1.06±0.004). Conclusion. This study establishes a protocol to collect electrical conductivity signals in spine surgery with synchronization to the depth of the instrument. Real-time conductivity signal feedback alerts the surgeon of a probable breach in the spinal canal, so he can change the direction of the pedicle aim.