David Kashy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Kashy has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Probir K. Ghoshal
Jefferson Lab, Newport News, VA, USA
10 shared publications - Ruben J. Fair
Jefferson Lab, Newport News, VA, USA
10 shared publications - Renuka Rajput-Ghoshal
Jefferson Lab, Newport News, VA, USA
7 shared publications - Eric Sun
Jefferson Lab, Newport News, VA, USA
5 shared publications - Michael P. Dion
Jefferson Lab, Newport News, VA, USA
3 shared publications - Sandesh Gopinath
Jefferson Lab, Newport News, VA, USA
3 shared publications
Latest Publications
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Assembly of the MOLLER Toroidal Magnets at Jefferson Lab
The MOLLER experiment at the Thomas Jefferson National Accelerator Facility (JLab) aims to precisely measure the weak interaction between electrons. This experiment leverages the 12 GeV electron beam and will run for three years. A crucial component of MOLLER is a system of five uniquely shaped water-cooled toroidal magnets. These magnets, possessing seven-fold symmetry, are designed to focus particles by separating electrons scattered off hydrogen in a liquid hydrogen target. The five magnets separate electrons scattered off electrons (Møller scattering) and protons (elastic e-p scattering) within target into approximately circular rings at the detector. This paper presents the assembly process for these five toroidal magnets, detailing critical steps including pin insertion, epoxy application, soldering and brazing, coil assembly, and alignment, all performed to meet stringent magnet specifications. Additionally, it discusses challenges encountered during construction and highlights lessons learned, offering insights for future magnet development projects.
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Assembly of the MOLLER Toroidal Magnets at Jefferson Lab
The MOLLER experiment at the Thomas Jefferson National Accelerator Facility (JLab) aims to precisely measure the weak interaction between electrons. This experiment leverages the 12 GeV electron beam and will run for three years. A crucial component of MOLLER is a system of five uniquely shaped water-cooled toroidal magnets. These magnets, possessing seven-fold symmetry, are designed to focus particles by separating electrons scattered off hydrogen in a liquid hydrogen target. The five magnets separate electrons scattered off electrons (Møller scattering) and protons (elastic e-p scattering) within target into approximately circular rings at the detector. This paper presents the assembly process for these five toroidal magnets, detailing critical steps including pin insertion, epoxy application, soldering and brazing, coil assembly, and alignment, all performed to meet stringent magnet specifications. Additionally, it discusses challenges encountered during construction and highlights lessons learned, offering insights for future magnet development projects.
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab
The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The “Measurement of Lepton-Lepton Electroweak Reaction” (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. The magnetic field generated by the Spectrometer is needed to separate the incident beam electrons that scatter from target electrons (Moller scattering) from the protons due to elastic e-p scattering within a liquid hydrogen target. This paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields
- 7 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab
The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The “Measurement of Lepton-Lepton Electroweak Reaction” (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. The magnetic field generated by the Spectrometer is needed to separate the incident beam electrons that scatter from target electrons (Moller scattering) from the protons due to elastic e-p scattering within a liquid hydrogen target. This paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (4) , 869-875
MOLLER Spectrometer Magnet Design With Measured Mechanical Properties of Irradiated S2-Glass Reinforced Cyanate Ester Resin at Elevated Temperature
The aim of this study was to retire the risk of maintaining the integrity of S2-glass reinforced CTD-403 (a cyanate ester resin) that is exposed to radiation and elevated temperature over the life of the MOLLER experiment in experimental Hall A at Jefferson Lab. In this paper, the shear strength and flexural modulus of irradiated S2-glass reinforced CTD-403 specimens were measured at 65 °C (the magnets are to operate at less than 65 °C) under two scenarios: vacuum and gaseous nitrogen. The testing method is the Short-Beam Shear (SBS) test according to ASTM D2344. The specimens were exposed to neutrons and gamma-rays up to 124 MGy. The results show that specimens have excellent resistance against radiation, only 23% degradation of apparent shear strength with 124 MGy at 65 °C under vacuum. At the highest dose areas of the coils tungsten plates are used to reduce the radiation dose to the resin system. The conclusion is that S2-glass reinforced CTD-403 is well suited for electrical insulation of MOLLER magnets.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (4) , 869-875
MOLLER Spectrometer Magnet Design With Measured Mechanical Properties of Irradiated S2-Glass Reinforced Cyanate Ester Resin at Elevated Temperature
The aim of this study was to retire the risk of maintaining the integrity of S2-glass reinforced CTD-403 (a cyanate ester resin) that is exposed to radiation and elevated temperature over the life of the MOLLER experiment in experimental Hall A at Jefferson Lab. In this paper, the shear strength and flexural modulus of irradiated S2-glass reinforced CTD-403 specimens were measured at 65 °C (the magnets are to operate at less than 65 °C) under two scenarios: vacuum and gaseous nitrogen. The testing method is the Short-Beam Shear (SBS) test according to ASTM D2344. The specimens were exposed to neutrons and gamma-rays up to 124 MGy. The results show that specimens have excellent resistance against radiation, only 23% degradation of apparent shear strength with 124 MGy at 65 °C under vacuum. At the highest dose areas of the coils tungsten plates are used to reduce the radiation dose to the resin system. The conclusion is that S2-glass reinforced CTD-403 is well suited for electrical insulation of MOLLER magnets.
- 30 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab
The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). This article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.
- 30 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab
The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). This article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.
- 7 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Comparison of Multi-Scale Nonlinear and Conventional Linear Methods for Stress Analysis of Nb3Sn Superconducting Magnets
This is an extension of the work on a multi-scale nonlinear procedure that demonstrated how to conduct nonlinear stress analysis of Nb 3 Sn superconducting accelerator magnets. The nonlinear procedure uses measured stress-strain curves of annealed copper, Nb 3 Sn strands and coil samples as inputs, which reduces the number of assumptions made for material properties—key uncertainties of any engineering analysis. The results from nonlinear analysis, semi-nonlinear analysis, and linear analysis of the same QFFB2 Nb 3 Sn quadrupole magnet under the same temperature and loads, were compared and discussed. The comparison illustrates that nonlinear stress analysis is significantly more accurate than other methods. As the superconducting coil block is a complex, composite material, it would be inadequate to assume the whole coil block to be linear, either isotropic or orthotropic. It is imperative to conduct nonlinear analysis by simulating the superconducting coil to the level of detail of the individual cables and individual strands. The nonlinear stress analysis procedure can be used to simulate not only Nb 3 Sn magnets, but also NbTi and HTS magnets.
- 7 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Comparison of Multi-Scale Nonlinear and Conventional Linear Methods for Stress Analysis of Nb3Sn Superconducting Magnets
This is an extension of the work on a multi-scale nonlinear procedure that demonstrated how to conduct nonlinear stress analysis of Nb 3 Sn superconducting accelerator magnets. The nonlinear procedure uses measured stress-strain curves of annealed copper, Nb 3 Sn strands and coil samples as inputs, which reduces the number of assumptions made for material properties—key uncertainties of any engineering analysis. The results from nonlinear analysis, semi-nonlinear analysis, and linear analysis of the same QFFB2 Nb 3 Sn quadrupole magnet under the same temperature and loads, were compared and discussed. The comparison illustrates that nonlinear stress analysis is significantly more accurate than other methods. As the superconducting coil block is a complex, composite material, it would be inadequate to assume the whole coil block to be linear, either isotropic or orthotropic. It is imperative to conduct nonlinear analysis by simulating the superconducting coil to the level of detail of the individual cables and individual strands. The nonlinear stress analysis procedure can be used to simulate not only Nb 3 Sn magnets, but also NbTi and HTS magnets.
- 9 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (8) , 1-11
General Failure Modes and Effects Analysis for Accelerator and Detector Magnet Design at JLab
The aim of this study is to develop a risk management procedure which could be applied to the magnet design process, for both superconducting and normal magnets at the Jefferson Laboratory (JLab). This procedure allowed us to identify the key risks at each of the critical phases of design and propose procedures, tests, and checks to mitigate each risk. In this paper we present a qualitative and quantitative risk management procedure com-monly referred to a "Failure Modes and Effects Analysis". As part of this procedure, we calculated a Risk Priority Number (RPN) for each activity of the process, identified the most critical activities and proposed mitigation activities which in turn result-ed in a revised RPN. Another benefit of this procedure was the identification of appropriate "Control and hold" points within the design process which allowed one to review and approve a particular outcome before proceeding to the next sequential activity.
- 9 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (8) , 1-11
General Failure Modes and Effects Analysis for Accelerator and Detector Magnet Design at JLab
The aim of this study is to develop a risk management procedure which could be applied to the magnet design process, for both superconducting and normal magnets at the Jefferson Laboratory (JLab). This procedure allowed us to identify the key risks at each of the critical phases of design and propose procedures, tests, and checks to mitigate each risk. In this paper we present a qualitative and quantitative risk management procedure com-monly referred to a "Failure Modes and Effects Analysis". As part of this procedure, we calculated a Risk Priority Number (RPN) for each activity of the process, identified the most critical activities and proposed mitigation activities which in turn result-ed in a revised RPN. Another benefit of this procedure was the identification of appropriate "Control and hold" points within the design process which allowed one to review and approve a particular outcome before proceeding to the next sequential activity.
- 22 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Interactions Observed Between Torus and Solenoid Superconducting Magnets at JLab
The Jefferson Lab 12 GeV Upgrade of Experimental End Station Hall B required a new detector system that would be more sensitive to forward going particles and able to handle higher luminosity. This new detector is CLAS12 and includes two superconducting iron-free magnets — a torus and an actively-shielded solenoid. The torus magnet consists of 6-trapezoidal racetrack-type coils while the solenoid is an actively shielded 5 T magnet. The torus and the solenoid are located in close proximity to one another and are surrounded by sensitive particle detectors. The torus and solenoid, operating at 3770 A and 2416 A respectively, were commissioned successfully and are operating normally. This paper presents observed electromagnetic interactions which include induced static mechanical loads and inductive coupling as well as a summary of some of the cryogenic interactions and how they are mitigated.
- 22 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (4) , 1-5
Interactions Observed Between Torus and Solenoid Superconducting Magnets at JLab
The Jefferson Lab 12 GeV Upgrade of Experimental End Station Hall B required a new detector system that would be more sensitive to forward going particles and able to handle higher luminosity. This new detector is CLAS12 and includes two superconducting iron-free magnets — a torus and an actively-shielded solenoid. The torus magnet consists of 6-trapezoidal racetrack-type coils while the solenoid is an actively shielded 5 T magnet. The torus and the solenoid are located in close proximity to one another and are surrounded by sensitive particle detectors. The torus and solenoid, operating at 3770 A and 2416 A respectively, were commissioned successfully and are operating normally. This paper presents observed electromagnetic interactions which include induced static mechanical loads and inductive coupling as well as a summary of some of the cryogenic interactions and how they are mitigated.
- 1 April 2020
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 959, 163425
The CLAS12 forward electromagnetic calorimeter
- 1 April 2020
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 959, 163425
The CLAS12 forward electromagnetic calorimeter
- 25 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (1) , 1-11
Preliminary Design Study of a Fast-Ramping Magnet for Preconcept Design of an Electron–Ion Collider at Jefferson Lab
The Jefferson Lab Electron Ion Collider (JLEIC) is a proposed new machine for nuclear physics research. The all new ion accelerator and collider complex will consist of two collider rings with a unique figure-of-eight layout to deliver a high degree of polarization in both beams. As part of the pre-concept design for the booster ring system, a fast ramping 3-Tesla Super-Ferric dipole magnet was proposed utilizing a superconducting Cable-in-Conduit-Conductor (CICC) design to wind the coils which will be built by Texas A&M University. Due to the design of the CICC with respect to the amount of stabilizer and the internal cooling mechanism employed, temperature rise of the coils during a quench event is much more rapid than for more conventional magnets. It is thus imperative that the magnet's stored energy is dissipated externally to the windings to avoid overheating the CICC and to provide adequate protection during a quench. This paper presents a preliminary design study, including AC effects inside the coils and associated risks with the aim of providing guidance for the design of the full protection system for such a magnet.
- 25 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 30 (1) , 1-11
Preliminary Design Study of a Fast-Ramping Magnet for Preconcept Design of an Electron–Ion Collider at Jefferson Lab
The Jefferson Lab Electron Ion Collider (JLEIC) is a proposed new machine for nuclear physics research. The all new ion accelerator and collider complex will consist of two collider rings with a unique figure-of-eight layout to deliver a high degree of polarization in both beams. As part of the pre-concept design for the booster ring system, a fast ramping 3-Tesla Super-Ferric dipole magnet was proposed utilizing a superconducting Cable-in-Conduit-Conductor (CICC) design to wind the coils which will be built by Texas A&M University. Due to the design of the CICC with respect to the amount of stabilizer and the internal cooling mechanism employed, temperature rise of the coils during a quench event is much more rapid than for more conventional magnets. It is thus imperative that the magnet's stored energy is dissipated externally to the windings to avoid overheating the CICC and to provide adequate protection during a quench. This paper presents a preliminary design study, including AC effects inside the coils and associated risks with the aim of providing guidance for the design of the full protection system for such a magnet.
- 4 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (4) , 1-10
Magnetic Field Mapping of the CLAS12 Torus—A Comparative Study Between the Engineering Model and Measurements at JLab
This paper provides an overview of the magnetic field measurement and subsequent electromagnetic re-modeling of the CLAS12 torus during the commissioning of the magnet in the fall of 2016. The CLAS12 detector in Hall B is part of the 12 GeV Accelerator Upgrade project at Jefferson Lab. The torus magnet allows precise determination of particle momenta within a cone ~ (5 $_0$ × 4 $^{0}$ ) in the forward direction. The ability to do this requires we know the fB.dl of the torus to within an accuracy of 0.5 % or better. To achieve this, an accurate model of the field along the particle paths is required. The TOSCA code is used to generate a full 3D simulation of the magnetic envelope of the magnet as designed. Experimentally the actual magnetic field within the magnet was surveyed to confirm the model design and to measure the deviation from the ideal case. The magnetic field deviations are attributed to manufacturing variability and assembly tolerances. A final model was created with allowances for these deviations guided by the survey data to create a more precise field integral model which greatly improves momentum resolution capability allowing it to deliver the required specifications.- 4 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (4) , 1-10
Magnetic Field Mapping of the CLAS12 Torus—A Comparative Study Between the Engineering Model and Measurements at JLab
This paper provides an overview of the magnetic field measurement and subsequent electromagnetic re-modeling of the CLAS12 torus during the commissioning of the magnet in the fall of 2016. The CLAS12 detector in Hall B is part of the 12 GeV Accelerator Upgrade project at Jefferson Lab. The torus magnet allows precise determination of particle momenta within a cone ~ (5 $_0$ × 4 $^{0}$ ) in the forward direction. The ability to do this requires we know the fB.dl of the torus to within an accuracy of 0.5 % or better. To achieve this, an accurate model of the field along the particle paths is required. The TOSCA code is used to generate a full 3D simulation of the magnetic envelope of the magnet as designed. Experimentally the actual magnetic field within the magnet was surveyed to confirm the model design and to measure the deviation from the ideal case. The magnetic field deviations are attributed to manufacturing variability and assembly tolerances. A final model was created with allowances for these deviations guided by the survey data to create a more precise field integral model which greatly improves momentum resolution capability allowing it to deliver the required specifications.