Vahid Farmehini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vahid Farmehini has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Nathan S. Swami
University of Virginia
2 shared publications - Alexandra R. Hyler
CytoRecovery, Inc., Blacksburg, VA 24060, USA
1 shared publication - Armita Salahi
Electrical & Computer Engineering, University of Virginia, 2358 Charlottesville, Virginia United States
1 shared publication - Charles P. Clark
Department of Chemistry, University of Virginia, Charlottesville, VA 22903, USA
1 shared publication - Jaka Cemazar
Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, Virginia United States 24061
1 shared publication - James P. Landers
Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
1 shared publication
Latest Publications
- 19 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (6) , 1664-1671
On-Chip Impedance for Quantifying Parasitic Voltages During AC Electrokinetic Trapping
Objective: Assessing the effectiveness of microfluidic device structures for enabling electrokinetic or acoustic trapping requires imaging of model particles within each device under the requisite force fields. To avoid the need for extensive microscopy, the use of valuable biological samples, and reliance on a trained operator to assess efficacy of trapping, we explore electrical means to identify device geometry variations that are responsible for the poor trapping. Results: Using the example of AC electrokinetic trapping over an insulated channel in a contact-less dielectrophoresis mode, we present an on-chip method to acquire impedance spectra on the microfluidic device for quantifying the parasitic voltage drops. Conclusion: Based on the parasitic voltage drops, device geometries can be designed to maximize fraction of the applied voltage that is available for dielectrophoretic manipulation and the measured on-chip impedance can rapidly inform downstream decisions on particle manipulation.
- 19 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (6) , 1664-1671
On-Chip Impedance for Quantifying Parasitic Voltages During AC Electrokinetic Trapping
Objective: Assessing the effectiveness of microfluidic device structures for enabling electrokinetic or acoustic trapping requires imaging of model particles within each device under the requisite force fields. To avoid the need for extensive microscopy, the use of valuable biological samples, and reliance on a trained operator to assess efficacy of trapping, we explore electrical means to identify device geometry variations that are responsible for the poor trapping. Results: Using the example of AC electrokinetic trapping over an insulated channel in a contact-less dielectrophoresis mode, we present an on-chip method to acquire impedance spectra on the microfluidic device for quantifying the parasitic voltage drops. Conclusion: Based on the parasitic voltage drops, device geometries can be designed to maximize fraction of the applied voltage that is available for dielectrophoretic manipulation and the measured on-chip impedance can rapidly inform downstream decisions on particle manipulation.
- Open Access
- 21 July 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (7) , 489
Real Time Electronic Feedback for Improved Acoustic Trapping of Micron-Scale Particles
Acoustic differential extraction has been previously reported as a viable alternative to the repetitive manual pipetting and centrifugation steps for isolating sperm cells from female epithelial cells in sexual assault sample evidence. However, the efficiency of sperm cell isolation can be compromised in samples containing an extremely large number of epithelial cells. When highly concentrated samples are lysed, changes to the physicochemical nature of the medium surrounding the cells impacts the acoustic frequency needed for optimal trapping. Previous work has demonstrated successful, automated adjustment of acoustic frequency to account for changes in temperature and buffer properties in various samples. Here we show that, during acoustic trapping, real-time monitoring of voltage measurements across the piezoelectric transducer correlates with sample-dependent changes in the medium. This is achieved with a wideband peak detector circuit, which identifies the resonant frequency with minimal disruption to the applied voltage. We further demonstrate that immediate, corresponding adjustments to acoustic trapping frequency provides retention of sperm cells from high epithelial cell-containing mock sexual assault samples.
- 21 July 2019
- Published by MDPI AG in Micromachines
- Vol. 10 (7) , 489
Open AccessReal Time Electronic Feedback for Improved Acoustic Trapping of Micron-Scale Particles
Acoustic differential extraction has been previously reported as a viable alternative to the repetitive manual pipetting and centrifugation steps for isolating sperm cells from female epithelial cells in sexual assault sample evidence. However, the efficiency of sperm cell isolation can be compromised in samples containing an extremely large number of epithelial cells. When highly concentrated samples are lysed, changes to the physicochemical nature of the medium surrounding the cells impacts the acoustic frequency needed for optimal trapping. Previous work has demonstrated successful, automated adjustment of acoustic frequency to account for changes in temperature and buffer properties in various samples. Here we show that, during acoustic trapping, real-time monitoring of voltage measurements across the piezoelectric transducer correlates with sample-dependent changes in the medium. This is achieved with a wideband peak detector circuit, which identifies the resonant frequency with minimal disruption to the applied voltage. We further demonstrate that immediate, corresponding adjustments to acoustic trapping frequency provides retention of sperm cells from high epithelial cell-containing mock sexual assault samples.