YCYidong Chen

Yidong Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yidong Chen has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enhancing Inhibition of Electrical Treeing in XLPE Cables Based on the Targeted Movement of Rejuvenation Fluid Induced by Electric Field

    by Yaping Wu, Kai Zhou, Siyan Lin, Zikang Wang, Yidong Chen, Guangya Zhu, Yao Fu

    In this study, the inhibition effect of electrical treeing is investigated in a cross-linked polyethylene (XLPE) cable under the targeted movement of rejuvenation fluid induced by an electric field. First, the fluid concentration around the defects is characterized by Fourier transform infrared spectroscopy (FTIR) under different voltages, application durations, and application temperatures. These results show that with increasing applied voltage, application duration and temperature, the fluid concentration around the defects increases nonlinearly. Next, the electrical treeing features of samples with and without electric field induction show that the tree initiation voltage increases and the tree accumulated damage decreases for the samples with electric field induction. By analyzing the changes in the molecular chain structure of the XLPE under different influencing factors, it is found that with applied voltage and duration increase and application temperature decreases, the methyl groups increase and the methylene groups decrease, the diffusion channel of fluid is expanded. Finally, it is proposed that the dielectrophoretic (DEP) force, changes in molecular chain structure, and molecular thermal motion determine the behaviors of the targeted movement of fluid in insulation. The fluid concentration around the defects increases after the targeted movement of fluid, and the electrical treeing inhibition effect is enhanced.


  • AC corrosion analysis of the buffer layer in HV corrugated-aluminum sheathed power cables

    by Jiamin Kong, Kai Zhou, Pengfei Meng, Qi Zhao, Yaping Wu, Xianchen Ren, Yidong Chen


  • Open Access

    Morphology evolution and breakdown mechanism of cross‐linked polyethylene (XLPE)–silicone rubber (SiR) interface induced by silicone grease diffusion

    by Zerui Li, Kai Zhou, Pengfei Meng, Hao Yuan, Zikang Wang, Yidong Chen, Yuan Li, Guangya Zhu

    Silicone grease (SG) is used for lubrication during cable accessory installation and can penetrate into the silicone rubber (SiR), leading to properties deterioration of the SiR. In this study, the effects of SG on the breakdown characteristics of the cross‐linked polyethylene (XLPE)–SiR interface are investigated. First, the variation of the XLPE–SiR interface breakdown voltage with SG coating time is experimentally explored. The interface breakdown voltage significantly increases after SG is applied, remains stable for coating times of up to approximately 144 h and then rapidly decreases; the minimum interface breakdown voltage is lower than that without the SG coating. Next, the effects of SG on the chemical composition and surface topography of the SiR are examined by infrared spectroscopy and optical profilometry, respectively. The SG penetration does not change the functional groups of the SiR but significantly increases its surface roughness. Finally, the interface electric‐field distribution after coating with SG is analysed by finite‐element simulation, revealing that the residual SG at the interface distorts the interface electric field after a long coating time. The increase in the SiR surface roughness caused by SG diffusion and the interface electric‐field distortion caused by the residual SG together lead to the decrease of the interface breakdown voltage.


  • Open Access

    Hydrogen evolution and electromigration in the corrosion of aluminium metal sheath inside high‐voltage cables

    by Yidong Chen, Kai Zhou, Jiamin Kong, Shakeel Akram, Xiancheng Ren, Xiaoshan Zhang, Yuan Li, Qi Zhao

    The urgent need for power transmission is the reason for leading research on the safer operation of high‐voltage cables. These high‐voltage cables are emerging as an efficient technology for underground power transmission. However, the electrochemical corrosion of aluminium (Al) metal sheaths in these cables is a common and challenging degradation process. Herein, the corrosion mechanisms and electrochemical analysis are investigated by using scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), electrochemical impedance spectroscopy (EIS) and laboratory‐designed electrochemical characterisation techniques. In the corrosion experiments, the authors evaluated the corrosion rate by measuring the release rate of hydrogen gas and explored the different roles of sodium polyacrylate (NaPA) during the corrosion process. It is found that the complexation reactions between NaPA and Al inhibited corrosion while increased the resistance of the buffer layer. The proposed mechanisms of corrosion in this study can improve the lifespan and sustainability of high‐voltage power transmission.


  • Insulating polysiloxane coating for XLPE‐Si‐rubber interfaces with high long‐term stability

    by Yidong Chen, Kai Zhou, Xiancheng Ren, Shijia Chen, Zerui Li

    Cable joints play an important role in the power supply systems, but at the same time, they greatly contribute to the majority of direct failures. Weak parts of the cable lines, especially for the solid‐solid interfaces in joints, attract much attention and are investigated by researchers worldwide. High‐voltage power transmission in electrical grids requires reliable and durable dielectric coatings for the interface insulation. The breakdown caused by local electric field enhancement is a gradual damaging process that leads to structural degradation and an increase of electrical conduction of dielectric materials, and ultimately, it results in catastrophic failure of the cable joints. Here, we demonstrate that the coating of silicone gel instead of silicone grease enables the improvements of tangential AC (alternating current) BDS (breakdown strength) and long‐term stability in the interfaces of joints. Under the pressure of Si‐rubber (silicone rubber) cold‐shrinkable cable accessories, the silicone gel almost did not lose, which improved the insulating stability of the interfaces. Our method allows us to fill the XLPE‐Si‐rubber (cross‐linked polyethylene and silicone rubber interfaces with silicone gel instead of silicone grease), which could reduce the risks of the power outage caused by cable joint faults.