JKJiamin Kong

Jiamin Kong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiamin Kong has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Novel Condition Assessment Method for Corrugated Aluminum Sheathed XLPE Cables Based on Evolved Gas Analysis

    by Jiamin Kong, Kai Zhou, Yidong Chen, Pengfei Meng, Yuan Li, Xiancheng Ren

    Condition assessment is significant to the maintenance management of high-voltage cross-linked polyethylene (XLPE) power cables. This paper presents a condition assessment method for corrugated aluminum sheathed cables based on evolved gas analysis. First, simultaneous thermogravimetric and mass spectrometric analyses of the pyrolysis of each cable material were conducted to characterize the gas generation caused by thermal faults. Simulated experiments were designed to investigate gas generation caused by electrical faults. The results show that different cable faults (low and high-temperature pyrolysis of semiconductors, insulation, and buffer materials; low and high energy discharge activity across insulation materials and electrochemical corrosion of the buffer material) show distinct gas generation characteristics. Based on the evolved gases, a method of identifying faults from the key gas concentration is proposed in this study. Moreover, gas transport within the corrugated aluminum sheathed cable with a buffer layer was analyzed, based on which a gas sampling method for cables with a buffer layer is proposed. Finally, the developed method was validated by practical applications. The proposed method is comparable to conducting a blood test on a human body in that it can help discover various incipient cable faults. The fundamentals and data interpretation methods are adaptable to all XLPE cables.


  • AC corrosion analysis of the buffer layer in HV corrugated-aluminum sheathed power cables

    by Jiamin Kong, Kai Zhou, Pengfei Meng, Qi Zhao, Yaping Wu, Xianchen Ren, Yidong Chen


  • Open Access

    Hydrogen evolution and electromigration in the corrosion of aluminium metal sheath inside high‐voltage cables

    by Yidong Chen, Kai Zhou, Jiamin Kong, Shakeel Akram, Xiancheng Ren, Xiaoshan Zhang, Yuan Li, Qi Zhao

    The urgent need for power transmission is the reason for leading research on the safer operation of high‐voltage cables. These high‐voltage cables are emerging as an efficient technology for underground power transmission. However, the electrochemical corrosion of aluminium (Al) metal sheaths in these cables is a common and challenging degradation process. Herein, the corrosion mechanisms and electrochemical analysis are investigated by using scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), electrochemical impedance spectroscopy (EIS) and laboratory‐designed electrochemical characterisation techniques. In the corrosion experiments, the authors evaluated the corrosion rate by measuring the release rate of hydrogen gas and explored the different roles of sodium polyacrylate (NaPA) during the corrosion process. It is found that the complexation reactions between NaPA and Al inhibited corrosion while increased the resistance of the buffer layer. The proposed mechanisms of corrosion in this study can improve the lifespan and sustainability of high‐voltage power transmission.


  • Open Access

    Inhibition of Rejuvenation Liquid on Trees in XLPE Cables under Switching Impulse Voltages

    by Guangya Zhu, Kai Zhou, Wei Gong, Min He, Jiaming Kong, Kangle Li

    In this paper, the inhibitory effect of preinjected rejuvenation liquid on trees in cross-linked polyethylene (XLPE) cables was investigated. Experimental samples were prepared by inserting needles into XLPE samples, and many equally-spaced holes existed in the outer semiconductive layer. All cable samples were divided into two groups. One sample group was treated with rejuvenation liquid, while the other group was the control group. A tree accelerated aging system was used to obtain trees in the XLPE cable samples. During the aging experiment, an impulse voltage was applied to the samples repeatedly. The micromorphologies of the two groups were observed. Based on the micromorphologies, two parameters were determined: the initiation rate of electrical trees and the average length of trees. Furthermore, the electric field distribution was simulated to analyze the initiation of electrical trees. The results indicate that an electrical tree is much harder to initiate in the pretreated XLPE cables than in the untreated cables. This phenomenon is likely attributed to the dielectrophoretic forces in the pretreated cables. Moreover, rejuvenation liquid deposited in XLPE causes a substantial reduction in the Maxwell stress of molecular chains. Rejuvenation liquid inhibits electrical tree initiation and water tree growth to a great extent.