Jiamin Kong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiamin Kong has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Kai Zhou
College of Electrical Engineering, Sichuan University, Chengdu, China
2 shared publications- Kai Zhou
College of Electrical Engineering, Sichuan University, Chengdu, China
2 shared publications Qi Zhao
2 shared publications- Yidong Chen
College of Electrical Engineering, Sichuan University, Chengdu, China
2 shared publications - Guangya Zhu
College of Electrical Engineering, Sichuan University, Chengdu, China
1 shared publication - Kangle Li
School of Electrical Engineering and Information, Sichuan University, No. 24 Yihuan Road, Chengdu 610065, China
1 shared publication
Latest Publications
- 9 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (2) , 883-891
A Novel Condition Assessment Method for Corrugated Aluminum Sheathed XLPE Cables Based on Evolved Gas Analysis
Condition assessment is significant to the maintenance management of high-voltage cross-linked polyethylene (XLPE) power cables. This paper presents a condition assessment method for corrugated aluminum sheathed cables based on evolved gas analysis. First, simultaneous thermogravimetric and mass spectrometric analyses of the pyrolysis of each cable material were conducted to characterize the gas generation caused by thermal faults. Simulated experiments were designed to investigate gas generation caused by electrical faults. The results show that different cable faults (low and high-temperature pyrolysis of semiconductors, insulation, and buffer materials; low and high energy discharge activity across insulation materials and electrochemical corrosion of the buffer material) show distinct gas generation characteristics. Based on the evolved gases, a method of identifying faults from the key gas concentration is proposed in this study. Moreover, gas transport within the corrugated aluminum sheathed cable with a buffer layer was analyzed, based on which a gas sampling method for cables with a buffer layer is proposed. Finally, the developed method was validated by practical applications. The proposed method is comparable to conducting a blood test on a human body in that it can help discover various incipient cable faults. The fundamentals and data interpretation methods are adaptable to all XLPE cables.
- 9 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (2) , 883-891
A Novel Condition Assessment Method for Corrugated Aluminum Sheathed XLPE Cables Based on Evolved Gas Analysis
Condition assessment is significant to the maintenance management of high-voltage cross-linked polyethylene (XLPE) power cables. This paper presents a condition assessment method for corrugated aluminum sheathed cables based on evolved gas analysis. First, simultaneous thermogravimetric and mass spectrometric analyses of the pyrolysis of each cable material were conducted to characterize the gas generation caused by thermal faults. Simulated experiments were designed to investigate gas generation caused by electrical faults. The results show that different cable faults (low and high-temperature pyrolysis of semiconductors, insulation, and buffer materials; low and high energy discharge activity across insulation materials and electrochemical corrosion of the buffer material) show distinct gas generation characteristics. Based on the evolved gases, a method of identifying faults from the key gas concentration is proposed in this study. Moreover, gas transport within the corrugated aluminum sheathed cable with a buffer layer was analyzed, based on which a gas sampling method for cables with a buffer layer is proposed. Finally, the developed method was validated by practical applications. The proposed method is comparable to conducting a blood test on a human body in that it can help discover various incipient cable faults. The fundamentals and data interpretation methods are adaptable to all XLPE cables.
- 3 June 2022
- Published by Elsevier in Engineering Failure Analysis
- Vol. 139
AC corrosion analysis of the buffer layer in HV corrugated-aluminum sheathed power cables
- 3 June 2022
- Published by Elsevier in Engineering Failure Analysis
- Vol. 139
AC corrosion analysis of the buffer layer in HV corrugated-aluminum sheathed power cables
- Open Access
- 25 November 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 7 (2) , 260-268
Hydrogen evolution and electromigration in the corrosion of aluminium metal sheath inside high‐voltage cables
The urgent need for power transmission is the reason for leading research on the safer operation of high‐voltage cables. These high‐voltage cables are emerging as an efficient technology for underground power transmission. However, the electrochemical corrosion of aluminium (Al) metal sheaths in these cables is a common and challenging degradation process. Herein, the corrosion mechanisms and electrochemical analysis are investigated by using scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), electrochemical impedance spectroscopy (EIS) and laboratory‐designed electrochemical characterisation techniques. In the corrosion experiments, the authors evaluated the corrosion rate by measuring the release rate of hydrogen gas and explored the different roles of sodium polyacrylate (NaPA) during the corrosion process. It is found that the complexation reactions between NaPA and Al inhibited corrosion while increased the resistance of the buffer layer. The proposed mechanisms of corrosion in this study can improve the lifespan and sustainability of high‐voltage power transmission.
- 25 November 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 7 (2) , 260-268
Open AccessHydrogen evolution and electromigration in the corrosion of aluminium metal sheath inside high‐voltage cables
The urgent need for power transmission is the reason for leading research on the safer operation of high‐voltage cables. These high‐voltage cables are emerging as an efficient technology for underground power transmission. However, the electrochemical corrosion of aluminium (Al) metal sheaths in these cables is a common and challenging degradation process. Herein, the corrosion mechanisms and electrochemical analysis are investigated by using scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), electrochemical impedance spectroscopy (EIS) and laboratory‐designed electrochemical characterisation techniques. In the corrosion experiments, the authors evaluated the corrosion rate by measuring the release rate of hydrogen gas and explored the different roles of sodium polyacrylate (NaPA) during the corrosion process. It is found that the complexation reactions between NaPA and Al inhibited corrosion while increased the resistance of the buffer layer. The proposed mechanisms of corrosion in this study can improve the lifespan and sustainability of high‐voltage power transmission.
- Open Access
Inhibition of Rejuvenation Liquid on Trees in XLPE Cables under Switching Impulse Voltages
In this paper, the inhibitory effect of preinjected rejuvenation liquid on trees in cross-linked polyethylene (XLPE) cables was investigated. Experimental samples were prepared by inserting needles into XLPE samples, and many equally-spaced holes existed in the outer semiconductive layer. All cable samples were divided into two groups. One sample group was treated with rejuvenation liquid, while the other group was the control group. A tree accelerated aging system was used to obtain trees in the XLPE cable samples. During the aging experiment, an impulse voltage was applied to the samples repeatedly. The micromorphologies of the two groups were observed. Based on the micromorphologies, two parameters were determined: the initiation rate of electrical trees and the average length of trees. Furthermore, the electric field distribution was simulated to analyze the initiation of electrical trees. The results indicate that an electrical tree is much harder to initiate in the pretreated XLPE cables than in the untreated cables. This phenomenon is likely attributed to the dielectrophoretic forces in the pretreated cables. Moreover, rejuvenation liquid deposited in XLPE causes a substantial reduction in the Maxwell stress of molecular chains. Rejuvenation liquid inhibits electrical tree initiation and water tree growth to a great extent.
Open AccessInhibition of Rejuvenation Liquid on Trees in XLPE Cables under Switching Impulse Voltages
In this paper, the inhibitory effect of preinjected rejuvenation liquid on trees in cross-linked polyethylene (XLPE) cables was investigated. Experimental samples were prepared by inserting needles into XLPE samples, and many equally-spaced holes existed in the outer semiconductive layer. All cable samples were divided into two groups. One sample group was treated with rejuvenation liquid, while the other group was the control group. A tree accelerated aging system was used to obtain trees in the XLPE cable samples. During the aging experiment, an impulse voltage was applied to the samples repeatedly. The micromorphologies of the two groups were observed. Based on the micromorphologies, two parameters were determined: the initiation rate of electrical trees and the average length of trees. Furthermore, the electric field distribution was simulated to analyze the initiation of electrical trees. The results indicate that an electrical tree is much harder to initiate in the pretreated XLPE cables than in the untreated cables. This phenomenon is likely attributed to the dielectrophoretic forces in the pretreated cables. Moreover, rejuvenation liquid deposited in XLPE causes a substantial reduction in the Maxwell stress of molecular chains. Rejuvenation liquid inhibits electrical tree initiation and water tree growth to a great extent.