MCMonique Melo Costa

Monique Melo Costa

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Monique Melo Costa has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MALDI-TOF MS Profiling and Its Contribution to Mosquito-Borne Diseases: A Systematic Review

    by Monique Melo Costa, Vincent Corbel, Refka Ben Hamouda, Lionel Almeras

    Mosquito-borne diseases are responsible for hundreds of thousands of deaths per year. The identification and control of the vectors that transmit pathogens to humans are crucial for disease prevention and management. Currently, morphological classification and molecular analyses via DNA barcoding are the standard methods used for vector identification. However, these approaches have several limitations. In the last decade, matrix-assisted laser desorption/ionization–time-of-flight mass spectrometry (MALDI-TOF MS) profiling has emerged as an innovative technology in biological sciences and is now considered as a relevant tool for the identification of pathogens and arthropods. Beyond species identification, this tool is also valuable for determining various life traits of arthropod vectors. The purpose of the present systematic review was to highlight the contribution of MALDI-TOF MS to the surveillance and control of mosquito-borne diseases. Published articles from January 2003 to August 2024 were retrieved, focusing on different aspects of mosquito life traits that could be determinants in disease transmission and vector management. The screening of the scientific literature resulted in the selection of 54 published articles that assessed MALDI-TOF MS profiling to study various mosquito biological factors, such species identification, life expectancy, gender, trophic preferences, microbiota, and insecticide resistance. Although a large majority of the selected articles focused on species identification, the present review shows that MALDI-TOF MS profiling is promising for rapidly identifying various mosquito life traits, with high-throughput capacity, reliability, and low cost. The strengths and weaknesses of this proteomic tool for vector control and surveillance are discussed.


  • Open Access

    MALDI-TOF MS profiling and its contribution to mosquito-borne diseases: a systematic review

    by Monique Melo Costa, Vincent Corbel, Refka Ben Hamouda, Lionel Almeras

    Mosquito-borne diseases are responsible for hundreds of thousands of deaths per year. The identification and control of the vectors that transmit pathogens to humans are crucial for disease prevention and management. Currently, morphological and molecular approaches are the standard methods used for vector identification, however, they present several limitations. In the last decade, matrix assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) profiling emerged as an innovative technology in Biological Sciences and is now considered as a relevant tool for the identification of pathogens and arthropods. Beyond species identification, this tool can be relevant for the determination of different life traits of arthropod vectors. The purpose of the present systematic review was to highlight the contribution of MALDI-TOF MS to the surveillance and control of mosquito-borne diseases. Published articles from January 2003 to September 2023 were retrieved, considering different aspects of mosquito life traits which could be determinant in the transmission of diseases and vector management. The screening of scientific literature resulted in the selection of 54 published articles that assessed MALDI-TOF MS profiling to study various biological factors such species identification, life expectancy, gender, trophic preferences, microbiota and insecticide resistance. Although a large majority of the selected articles focused on species identification, the present review shows that MALDI-TOF MS profiling is promising for identifying various mosquito life traits with rapidity, high throughput capacity, reliability and low cost. The strength and weakness of this proteomic tool for vector control and surveillance are discussed.


  • Open Access

    Identification of Neotropical Culex Mosquitoes by MALDI-TOF MS Profiling

    by Monique Melo Costa, Amandine Guidez, Sébastien Briolant, Stanislas Talaga, Jean Issaly, Halima Naroua, Romuald Carinci, Pascal Gaborit, Anne Lavergne, Isabelle Dusfour, et al.

    The mosquito (Diptera: Culicidae) fauna of French Guiana encompasses 242 species, of which nearly half of them belong to the genus Culex. Whereas several species of Culex are important vectors of arboviruses, only a limited number of studies focus on them due to the difficulties to morphologically identify field-caught females. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been reported as a promising method for the identification of mosquitoes. Culex females collected in French Guiana were morphologically identified and dissected. Abdomens were used for molecular identification using the COI (cytochrome oxidase 1) gene. Legs and thorax of 169 specimens belonging to 13 Culex species, (i.e., Cx. declarator, Cx. nigripalpus, Cx. quinquefasciatus, Cx. usquatus, Cx. adamesi, Cx. dunni, Cx. eastor, Cx. idottus, Cx. pedroi, Cx. phlogistus, Cx. portesi, Cx. rabanicolus and Cx. spissipes) were then submitted to MALDI-TOF MS analysis. A high intra-species reproducibility and inter-species specificity of MS spectra for each mosquito body part tested were obtained. A corroboration of the specimen identification was revealed between MALDI-TOF MS, morphological and molecular results. MALDI-TOF MS protein profiling proves to be a suitable tool for identification of neotropical Culex species and will permit the enhancement of knowledge on this highly diverse genus.


  • Open Access

    Identification of Neotropical Culex Mosquitoes by MALDI-TOF MS Profiling

    by Monique Melo Costa, Amandine Guidez, Sébastien Briolant, Stanislas Talaga, Jean Issaly, Halima Naroua, Romuald Carinci, Pascal Gaborit, Anne Lavergne, Isabelle Dusfour, et al.

    French Guiana mosquito fauna diversity encompasses 242 species, of which nearly half of them belong to Culex (Diptera: Culicidae) genus. Whereas several species from Culex genus are important vectors of arbovirus, scarce studies focus on Culex genus, notably due to the inaccurate morphological identification of field-caught females gender. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been reported as a promising method for the identification of mosquitoes. Culex females from French Guiana field were dissected based on morphological classification. Abdomens were used for molecular identification using COI (cytochrome oxydase 1) gene. Legs and thorax of 169 specimens belonging to 13 Culex species,( i.e. Cx. declarator, Cx. nigripalpus, Cx. quinquefasciatus, Cx. usquatus, Cx. adamesi, Cx. dunni, Cx. eastor, Cx. idottus, Cx. pedroi, Cx. phlogistus, Cx. portesi, Cx. rabanicolus and Cx. spissipes) were then submitted to MALDI-TOF MS analysis. A high intra-species reproducibility and inter-species specificity of MS spectra for each mosquito body part tested were noticed. A corroboration of the specimen identification was revealed between MALDI-TOF MS, morphological and molecular results. MALDI-TOF MS protein profiling proves to be a suitable tool for identification of neotropical Culex species and will permit to enhance knowledge on this highly diverse Culex mosquitoes genus.


  • Open Access

    Enhanced procedures for mosquito identification by MALDI-TOF MS

    by Roland Bamou, Monique Melo Costa, Adama Zan Diarra, Ademir Jesus Martins, Philippe Parola, Lionel Almeras

    Background: In the last decade, an innovative approach has emerged for arthropod identification based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). Increasing interest in applying the original technique for arthropod identification has led to the development of a variety of procedures for sample preparation and selection of body parts, among others. However, the absence of a consensual strategy hampers direct inter-study comparisons. Moreover, these different procedures are confusing to new users. Establishing optimized procedures and standardized protocols for mosquito identification by MALDI-TOF MS is therefore a necessity, and would notably enable the sharing of reference MS databases. Here, we assess the optimal conditions for mosquito identification using MALDI-TOF MS profiling. Methods: Three homogenization methods, two of which were manual and one automatic, were used on three distinct body parts (legs, thorax, head) of two mosquito laboratory strains, Anopheles coluzzii and Aedes aegypti, and the results evaluated. The reproducibility of MS profiles, identification rate with relevant scores and the suitability of procedures for high-throughput analyses were the main criteria for establishing optimized guidelines. Additionally, the consequences of blood-feeding and geographical origin were evaluated using both laboratory strains and field-collected mosquitoes. Results: Relevant score values for mosquito identification were obtained for all the three body parts assayed using MALDI-TOF MS profiling; however, the thorax and legs were the most suitable specimens, independently of homogenization method or species. Although the manual homogenization methods were associated with a high rate of identification on the three body parts, this homogenization mode is not adaptable to the processing of a large number of samples. Therefore, the automatic homogenization procedure was selected as the reference homogenization method. Blood-feeding status did not hamper the identification of mosquito species, despite the presence of MS peaks from original blood in the MS profiles of the three body parts tested from both species. Finally, a significant improvement in identification scores was obtained for field-collected specimens when MS spectra of species from the same geographical area were added to the database. Conclusion: The results of the current study establish guidelines for the selection of mosquito anatomic parts and modality of sample preparation (e.g. homogenization) for future specimen identification by MALDI-TOF MS profiling. These standardized operational protocols could be used as references for creating an international MS database.


  • Open Access

    Exploratory Study on Application of MALDI-TOF-MS to Detect SARS-CoV-2 Infection in Human Saliva

    by Monique Melo Costa, Hugo Martin, Bertrand Estellon, François-Xavier Dupé, Florian Saby, Nicolas Benoit, Hervé Tissot-Dupont, Matthieu Million, Bruno Pradines, Samuel Granjeaud, et al.

    SARS-CoV-2 has caused a large outbreak since its emergence in December 2019. COVID-19 diagnosis became a priority so as to isolate and treat infected individuals in order to break the contamination chain. Currently, the reference test for COVID-19 diagnosis is the molecular detection (RT-qPCR) of the virus from nasopharyngeal swab (NPS) samples. Although this sensitive and specific test remains the gold standard, it has several limitations, such as the invasive collection method, the relative high cost and the duration of the test. Moreover, the material shortage to perform tests due to the discrepancy between the high demand for tests and the production capacities puts additional constraints on RT-qPCR. Here, we propose a PCR-free method for diagnosing SARS-CoV-2 based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) profiling and machine learning (ML) models from salivary samples. Kinetic saliva samples were collected at enrollment and ten and thirty days later (D0, D10 and D30), to assess the classification performance of the ML models compared to the molecular tests performed on NPS specimens. Spectra were generated using an optimized protocol of saliva collection and successive quality control steps were developed to ensure the reliability of spectra. A total of 360 averaged spectra were included in the study. At D0, the comparison of MS spectra from SARS-CoV-2 positive patients (n = 105) with healthy healthcare controls (n = 51) revealed nine peaks that significantly distinguished the two groups. Among the five ML models tested, support vector machine with linear kernel (SVM-LK) provided the best performance on the training dataset (accuracy = 85.2%, sensitivity = 85.1%, specificity = 85.3%, F1-Score = 85.1%). The application of the SVM-LK model on independent datasets confirmed its performances with 88.9% and 80.8% of correct classification for samples collected at D0 and D30, respectively. Conversely, at D10, the proportion of correct classification had fallen to 64.3%. The analysis of saliva samples by MALDI-TOF MS and ML appears as an interesting supplementary tool for COVID-19 diagnosis, despite the mitigated results obtained for convalescent patients (D10).


  • Open Access

    Exploratory Study on Application of MALDI-TOF-MS to Detect SARS-CoV-2 Infection in Human Saliva

    by Monique Melo Costa, Hugo Martin, Bertrand Estellon, François-Xavier Dupé, Floriant Saby, Nicolas Benoit, Hervé Tissot-Dupont, Matthieu Million, Bruno Pradines, Samuel Granjeaud, et al.

    SARS-CoV-2 caused a large outbreak since its emergence in December 2019. The COVID-19 diagnosis became a priority to isolate and treat infected individuals in order to break the contamination chain. Currently, the reference test for COVID-19 diagnosis is the molecular detection (RT-qPCR) of the virus from nasopharyngeal swab (NPS) samples. Although this sensitive and specific test remains the gold standard, it has several limitations, such as the invasive collection method, the relative high cost and the duration of the test. Moreover, the material shortage to perform tests due to the discrepancy between the high demand for tests and the production capacities puts additional constraints on RT-qPCR. Here, we propose a PCR-free method for diagnosing SARS-CoV-2 based on Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) profiling and machine learning (ML) models from salivary samples. Kinetic saliva samples were collected at enrollment and ten and thirty days later (D0, D10 and D30), to assess the classification performance of the ML models compared to the molecular tests performed on NPS specimens. Spectra were generated using an optimized protocol of saliva collection and successive quality control steps were developed to ensure the reliability of spectra. A total of 360 averaged spectra were included in the study. At D0, the comparison of MS spectra from SARS-CoV-2 positive patients (n=105) with healthy healthcare controls (n=51) revealed nine peaks that significantly distinguished the two groups. Among the five ML models tested, Support Vector Machine with Linear Kernel (SVM-LK) provided the best performance on the training dataset (accuracy = 85.2 %, sensitivity = 85.1 %, specificity = 85.3 %, F1-Score = 85.1 %). The application of the SVM-LK model on independent datasets confirmed it performances with 88.9% and 80.8% of correct classification for samples collected at D0 and D30, respectively. Conversely, at D10, the proportion of correct classification fallen to 64.3%. The analysis of saliva samples by MALDI-TOF MS and ML appears as an interesting supplementary tool for COVID-19 diagnosis, despite the mitigated results obtained for convalescent patients (D10).


  • Open Access

    Mouth Washing Impaired SARS-CoV-2 Detection in Saliva

    by Monique Melo Costa, Nicolas Benoit, Hervé Tissot-Dupont, Matthieu Million, Bruno Pradines, Samuel Granjeaud, Lionel Almeras

    Background: A previous study demonstrated the performance of the Salivette® (SARSTEDT, Numbrecht, Germany) as a homogeneous saliva collection system to diagnose COVID-19 by RT-qPCR, notably for symptomatic and asymptomatic patients. However, for convalescent patients, the corroboration of molecular detection of SARS-CoV-2 in paired nasopharyngeal swabs (NPS) and saliva samples was unsatisfactory. Objectives: The aim of the present work was to assess the concordance level of SARS-CoV-2 detection between paired sampling of NPSs and saliva collected with Salivette® at two time points, with ten days of interval. Results: A total of 319 paired samples from 145 outpatients (OP) and 51 healthcare workers (HW) were collected. Unfortunately, at day ten, 73 individuals were lost to follow-up, explaining some kinetic missing data. Due to significant waiting rates at hospitals, most of the patients ate and/or drank while waiting for their turn. Consequently, mouth washing was systematically proposed prior to saliva collection. None of the HW were diagnosed as SARS-CoV-2 positive using NPS or saliva specimens at both time points (n = 95) by RT-qPCR. The virus was detected in 56.3% (n = 126/224) of the NPS samples from OP, but solely 26.8% (n = 60/224) of the paired saliva specimens. The detection of the internal cellular control, the human RNase P, in more than 98% of the saliva samples, underlined that the low sensitivity of saliva specimens (45.2%) for SARS-CoV-2 detection was not attributed to an improper saliva sample storing or RNA extraction. Conclusions: This work revealed that mouth washing decreased viral load of buccal cavity conducting to impairment of SARS-CoV-2 detection. Viral loads in saliva neo-produced appeared insufficient for molecular detection of SARS-CoV-2. At the time when saliva tests could be a rapid, simple and non-invasive strategy to assess large scale schoolchildren in France, the determination of the performance of saliva collection becomes imperative to standardize procedures.


  • Open Access

    Optimization and Standardization of Human Saliva Collection for MALDI-TOF MS

    by Monique Melo Costa, Nicolas Benoit, Florian Saby, Bruno Pradines, Samuel Granjeaud, Lionel Almeras

    SARS-CoV-2 outbreak led to unprecedented innovative scientific research to preclude the virus dissemination and limit its impact on life expectancy. Waiting for the collective immunity by vaccination, mass-testing, and isolation of positive cases remain essential. The development of a diagnosis method requiring a simple and non-invasive sampling with a quick and low-cost approach is on demand. We hypothesized that the combination of saliva specimens with MALDI-TOF MS profiling analyses could be the winning duo. Before characterizing MS saliva signatures associated with SARS-CoV-2 infection, optimization and standardization of sample collection, preparation and storage up to MS analyses appeared compulsory. In this view, successive experiments were performed on saliva from healthy healthcare workers. Specimen sampling with a roll cotton of Salivette® devices appeared the most appropriate collection mode. Saliva protein precipitation with organic buffers did not improved MS spectra profiles compared to a direct loading of samples mixed with acetonitrile/formic acid buffer onto MS plate. The assessment of sample storage conditions and duration revealed that saliva should be stored on ice until MS analysis, which should occur on the day of sampling. Kinetic collection of saliva highlighted reproducibility of saliva MS profiles over four successive days and also at two-week intervals. The intra-individual stability of saliva MS profiles should be a key factor in the future investigation for biomarkers associated with SARS-CoV-2 infection. However, the singularity of MS profiles between individuals will require the development of sophisticated bio-statistical analyses such as machine learning approaches. MALDI-TOF MS profiling of saliva could be a promising PCR-free tool for SARS-CoV-2 screening.


  • Open Access

    Identification of French Guiana anopheline mosquitoes by MALDI-TOF MS profiling using protein signatures from two body parts

    by Sébastien Briolant, Monique de Melo Costa, Christophe Nguyen, Isabelle Dusfour, Vincent Pommier de Santi, Romain Girod, Lionel Almeras

    In French Guiana, the malaria, a parasitic infection transmitted by Anopheline mosquitoes, remains a disease of public health importance. To prevent malaria transmission, the main effective way remains Anopheles control. For an effective control, accurate Anopheles species identification is indispensable to distinguish malaria vectors from non-vectors. Although, morphological and molecular methods are largely used, an innovative tool, based on protein pattern comparisons, the Matrix Assisted Laser Desorption / Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) profiling, emerged this last decade for arthropod identification. However, the limited mosquito fauna diversity of reference MS spectra remains one of the main drawback for it large usage. The aim of the present study was then to create and to share reference MS spectra for the identification of French Guiana Anopheline species. A total of eight distinct Anopheles species, among which four are malaria vectors, were collected in 6 areas. To improve Anopheles identification, two body parts, legs and thoraxes, were independently submitted to MS for the creation of respective reference MS spectra database (DB). This study underlined that double checking by MS enhanced the Anopheles identification confidence and rate of reliable classification. The sharing of this reference MS spectra DB should made easier Anopheles species monitoring in endemic malaria area to help malaria vector control or elimination programs.