HTHervé Tissot-Dupont

Hervé Tissot-Dupont

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hervé Tissot-Dupont has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Exploratory Study on Application of MALDI-TOF-MS to Detect SARS-CoV-2 Infection in Human Saliva

    by Monique Melo Costa, Hugo Martin, Bertrand Estellon, François-Xavier Dupé, Florian Saby, Nicolas Benoit, Hervé Tissot-Dupont, Matthieu Million, Bruno Pradines, Samuel Granjeaud, et al.

    SARS-CoV-2 has caused a large outbreak since its emergence in December 2019. COVID-19 diagnosis became a priority so as to isolate and treat infected individuals in order to break the contamination chain. Currently, the reference test for COVID-19 diagnosis is the molecular detection (RT-qPCR) of the virus from nasopharyngeal swab (NPS) samples. Although this sensitive and specific test remains the gold standard, it has several limitations, such as the invasive collection method, the relative high cost and the duration of the test. Moreover, the material shortage to perform tests due to the discrepancy between the high demand for tests and the production capacities puts additional constraints on RT-qPCR. Here, we propose a PCR-free method for diagnosing SARS-CoV-2 based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) profiling and machine learning (ML) models from salivary samples. Kinetic saliva samples were collected at enrollment and ten and thirty days later (D0, D10 and D30), to assess the classification performance of the ML models compared to the molecular tests performed on NPS specimens. Spectra were generated using an optimized protocol of saliva collection and successive quality control steps were developed to ensure the reliability of spectra. A total of 360 averaged spectra were included in the study. At D0, the comparison of MS spectra from SARS-CoV-2 positive patients (n = 105) with healthy healthcare controls (n = 51) revealed nine peaks that significantly distinguished the two groups. Among the five ML models tested, support vector machine with linear kernel (SVM-LK) provided the best performance on the training dataset (accuracy = 85.2%, sensitivity = 85.1%, specificity = 85.3%, F1-Score = 85.1%). The application of the SVM-LK model on independent datasets confirmed its performances with 88.9% and 80.8% of correct classification for samples collected at D0 and D30, respectively. Conversely, at D10, the proportion of correct classification had fallen to 64.3%. The analysis of saliva samples by MALDI-TOF MS and ML appears as an interesting supplementary tool for COVID-19 diagnosis, despite the mitigated results obtained for convalescent patients (D10).


  • Open Access

    Internet of Things to Explore Moment 2 of “WHO My Five Moments” for Hand Hygiene

    by Olga Florea, Jeremy Gonin, Hervé Tissot Dupont, Jean Charles Dufour, Philippe Brouqui, Sophia Boudjema

    Background: Electronic hand hygiene surveillance systems are developing and considered to be more reliable than direct observation for hand hygiene monitoring. However, none have the capability to assess compliance in complex nursing care.Materials and Methods: We combined two different technologies, a hand hygiene monitoring system (radiofrequency identification, RFID) and a nursing care recorder at the bedside, and we merge their data to assess hand hygiene performance during nursing. Nursing tasks were classified as standard task procedures or aseptic task procedures corresponding to moment 2 among the five moments for hand hygiene recommended by the WHO. All statistical analyses were performed using R, version 3.6.2. For mixed models, the package “lme4” was used.Results: From the merged database over the 2-year study period, 30,164 nursing tasks were identified for analysis, 25,633 were classified as standard task procedures, and 4,531 were classified as aseptic task procedures for nursing care. Hand disinfection with an alcohol-based solution was not detected with our system in 42.5% of all the recorded tasks, 37% of all the aseptic task procedures, and 47.1% of all the standard task procedures for nursing (p = 0.0362), indicating that WHO moment 2 was not respected in 37% of mandatory situations.Conclusion: Using a combination of different technologies, we were able to assess hand hygiene performance in the riskiest circumstances.


  • Open Access

    Exploratory Study on Application of MALDI-TOF-MS to Detect SARS-CoV-2 Infection in Human Saliva

    by Monique Melo Costa, Hugo Martin, Bertrand Estellon, François-Xavier Dupé, Floriant Saby, Nicolas Benoit, Hervé Tissot-Dupont, Matthieu Million, Bruno Pradines, Samuel Granjeaud, et al.

    SARS-CoV-2 caused a large outbreak since its emergence in December 2019. The COVID-19 diagnosis became a priority to isolate and treat infected individuals in order to break the contamination chain. Currently, the reference test for COVID-19 diagnosis is the molecular detection (RT-qPCR) of the virus from nasopharyngeal swab (NPS) samples. Although this sensitive and specific test remains the gold standard, it has several limitations, such as the invasive collection method, the relative high cost and the duration of the test. Moreover, the material shortage to perform tests due to the discrepancy between the high demand for tests and the production capacities puts additional constraints on RT-qPCR. Here, we propose a PCR-free method for diagnosing SARS-CoV-2 based on Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) profiling and machine learning (ML) models from salivary samples. Kinetic saliva samples were collected at enrollment and ten and thirty days later (D0, D10 and D30), to assess the classification performance of the ML models compared to the molecular tests performed on NPS specimens. Spectra were generated using an optimized protocol of saliva collection and successive quality control steps were developed to ensure the reliability of spectra. A total of 360 averaged spectra were included in the study. At D0, the comparison of MS spectra from SARS-CoV-2 positive patients (n=105) with healthy healthcare controls (n=51) revealed nine peaks that significantly distinguished the two groups. Among the five ML models tested, Support Vector Machine with Linear Kernel (SVM-LK) provided the best performance on the training dataset (accuracy = 85.2 %, sensitivity = 85.1 %, specificity = 85.3 %, F1-Score = 85.1 %). The application of the SVM-LK model on independent datasets confirmed it performances with 88.9% and 80.8% of correct classification for samples collected at D0 and D30, respectively. Conversely, at D10, the proportion of correct classification fallen to 64.3%. The analysis of saliva samples by MALDI-TOF MS and ML appears as an interesting supplementary tool for COVID-19 diagnosis, despite the mitigated results obtained for convalescent patients (D10).


  • Open Access

    Mouth Washing Impaired SARS-CoV-2 Detection in Saliva

    by Monique Melo Costa, Nicolas Benoit, Hervé Tissot-Dupont, Matthieu Million, Bruno Pradines, Samuel Granjeaud, Lionel Almeras

    Background: A previous study demonstrated the performance of the Salivette® (SARSTEDT, Numbrecht, Germany) as a homogeneous saliva collection system to diagnose COVID-19 by RT-qPCR, notably for symptomatic and asymptomatic patients. However, for convalescent patients, the corroboration of molecular detection of SARS-CoV-2 in paired nasopharyngeal swabs (NPS) and saliva samples was unsatisfactory. Objectives: The aim of the present work was to assess the concordance level of SARS-CoV-2 detection between paired sampling of NPSs and saliva collected with Salivette® at two time points, with ten days of interval. Results: A total of 319 paired samples from 145 outpatients (OP) and 51 healthcare workers (HW) were collected. Unfortunately, at day ten, 73 individuals were lost to follow-up, explaining some kinetic missing data. Due to significant waiting rates at hospitals, most of the patients ate and/or drank while waiting for their turn. Consequently, mouth washing was systematically proposed prior to saliva collection. None of the HW were diagnosed as SARS-CoV-2 positive using NPS or saliva specimens at both time points (n = 95) by RT-qPCR. The virus was detected in 56.3% (n = 126/224) of the NPS samples from OP, but solely 26.8% (n = 60/224) of the paired saliva specimens. The detection of the internal cellular control, the human RNase P, in more than 98% of the saliva samples, underlined that the low sensitivity of saliva specimens (45.2%) for SARS-CoV-2 detection was not attributed to an improper saliva sample storing or RNA extraction. Conclusions: This work revealed that mouth washing decreased viral load of buccal cavity conducting to impairment of SARS-CoV-2 detection. Viral loads in saliva neo-produced appeared insufficient for molecular detection of SARS-CoV-2. At the time when saliva tests could be a rapid, simple and non-invasive strategy to assess large scale schoolchildren in France, the determination of the performance of saliva collection becomes imperative to standardize procedures.