Zhongxue Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhongxue Chang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Guobing Song
10 shared publications- Guobing Song
School of Electrical Engineering, Xian Jiaotong University, Xian, China
8 shared publications - Chenhao Zhang
School of Electrical Engineering, Xian Jiaotong University, Xian, China
6 shared publications Weibin Tan
6 shared publications- Jifei Yan
School of Electrical Engineering Xi'an Jiaotong University Xi'an Shaanxi China
4 shared publications - Huan Li
Xi'an Jiaotong University
3 shared publications
Latest Publications
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (4) , 2760-2776
A Single-Ended Whole-Line Protection for Active Distribution Networks Using Constructed Resonant Boundary Element
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (4) , 2760-2776
A Single-Ended Whole-Line Protection for Active Distribution Networks Using Constructed Resonant Boundary Element
- 5 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 260
A sequential reclosing strategy for distribution lines with permanent fault identification capability
- 5 June 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 260
A sequential reclosing strategy for distribution lines with permanent fault identification capability
- 26 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3729-3744
A Setting-Free Single-Ended Fault Detection Method for Multiterminal DC Systems Based on Active Boundary Control
The increasing integration of power electronic equipment into modern power systems has led to the gradual weakening or elimination of boundary components, posing significant challenges for single-ended whole-line fault identification. To address this issue, this paper employs coordinated active boundary control and signal injection control during the fault steady-state to enhance fault characteristics and establish series-connected boundary properties. A fault analysis is established using modal network modeling for both pole-to-ground (P2G) and pole-to-pole (P2P) faults. The results demonstrate that the injected characteristic frequency current magnitude at the protection point increases or remains unchanged in the case of internal faults, while it decreases under external faults. Based on this, a novel single-ended setting-free protection criterion is proposed, which is independent of system parameters, simulations, and complex calculations. Its performance is validated on a multi-terminal hybrid HVDC transmission system. Simulation and experimental results confirm that the method achieves whole-line fault identification under fault resistances up to 500 Ω, noise levels up to 20 dB, and parameter variations, demonstrating high robustness and reliability even in weak or non-boundary scenarios.
- 26 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3729-3744
A Setting-Free Single-Ended Fault Detection Method for Multiterminal DC Systems Based on Active Boundary Control
The increasing integration of power electronic equipment into modern power systems has led to the gradual weakening or elimination of boundary components, posing significant challenges for single-ended whole-line fault identification. To address this issue, this paper employs coordinated active boundary control and signal injection control during the fault steady-state to enhance fault characteristics and establish series-connected boundary properties. A fault analysis is established using modal network modeling for both pole-to-ground (P2G) and pole-to-pole (P2P) faults. The results demonstrate that the injected characteristic frequency current magnitude at the protection point increases or remains unchanged in the case of internal faults, while it decreases under external faults. Based on this, a novel single-ended setting-free protection criterion is proposed, which is independent of system parameters, simulations, and complex calculations. Its performance is validated on a multi-terminal hybrid HVDC transmission system. Simulation and experimental results confirm that the method achieves whole-line fault identification under fault resistances up to 500 Ω, noise levels up to 20 dB, and parameter variations, demonstrating high robustness and reliability even in weak or non-boundary scenarios.
- Open Access
- 14 February 2026
- Published by Wiley
Permanent Fault Identification Scheme for Distribution Feeders Using Detection-Based Reclosing
To mitigate secondary damage caused by reclosing a distribution line with a permanent fault, a highly sensitive fault property identification scheme using detection-based reclosing is proposed in this paper. Firstly, the analytical model for single-phase detection-based reclosing in distribution networks is established to reveal the differences between transient and permanent faults. Given that the equivalent fault resistance of permanent ground faults differs significantly from the insulation resistance of transient faults, an equivalent fault resistance calculation method is proposed to improve the sensitivity of fault property identification. Furthermore, to reduce the impact of fault resistance and load capacity on phase-to-phase fault property identification sensitivity, a permanent fault identification method utilizing the phase-to-phase impedance ratio is proposed. Finally, a comprehensive detection-based reclosing scheme is developed. Validation results based on PSCAD simulations and RTDS closed-loop tests demonstrate that the proposed scheme exhibits both wide applicability across various scenarios and high sensitivity.
- 14 February 2026
- Published by Wiley
Open AccessPermanent Fault Identification Scheme for Distribution Feeders Using Detection-Based Reclosing
To mitigate secondary damage caused by reclosing a distribution line with a permanent fault, a highly sensitive fault property identification scheme using detection-based reclosing is proposed in this paper. Firstly, the analytical model for single-phase detection-based reclosing in distribution networks is established to reveal the differences between transient and permanent faults. Given that the equivalent fault resistance of permanent ground faults differs significantly from the insulation resistance of transient faults, an equivalent fault resistance calculation method is proposed to improve the sensitivity of fault property identification. Furthermore, to reduce the impact of fault resistance and load capacity on phase-to-phase fault property identification sensitivity, a permanent fault identification method utilizing the phase-to-phase impedance ratio is proposed. Finally, a comprehensive detection-based reclosing scheme is developed. Validation results based on PSCAD simulations and RTDS closed-loop tests demonstrate that the proposed scheme exhibits both wide applicability across various scenarios and high sensitivity.
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Permanent Fault Identification Scheme for Distribution Feeders Using Detection‐Based Reclosing
To mitigate secondary damage caused by reclosing a distribution line with a permanent fault, a highly sensitive fault property identification scheme using detection‐based reclosing is proposed in this paper. Firstly, the analytical model for single‐phase detection‐based reclosing in distribution networks is established to reveal the differences between transient and permanent faults. Given that the equivalent fault resistance of permanent ground faults differs significantly from the insulation resistance of transient faults, an equivalent fault resistance calculation method is proposed to improve the sensitivity of fault property identification. Furthermore, to reduce the impact of fault resistance and load capacity on phase‐to‐phase fault property identification sensitivity, a permanent fault identification method utilizing the line voltage ratio is proposed. Finally, a comprehensive detection‐based reclosing scheme is developed. Validation results based on PSCAD simulations and RTDS closed‐loop tests demonstrate that the proposed scheme exhibits both wide applicability across various scenarios and high sensitivity.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1)
Open AccessPermanent Fault Identification Scheme for Distribution Feeders Using Detection‐Based Reclosing
To mitigate secondary damage caused by reclosing a distribution line with a permanent fault, a highly sensitive fault property identification scheme using detection‐based reclosing is proposed in this paper. Firstly, the analytical model for single‐phase detection‐based reclosing in distribution networks is established to reveal the differences between transient and permanent faults. Given that the equivalent fault resistance of permanent ground faults differs significantly from the insulation resistance of transient faults, an equivalent fault resistance calculation method is proposed to improve the sensitivity of fault property identification. Furthermore, to reduce the impact of fault resistance and load capacity on phase‐to‐phase fault property identification sensitivity, a permanent fault identification method utilizing the line voltage ratio is proposed. Finally, a comprehensive detection‐based reclosing scheme is developed. Validation results based on PSCAD simulations and RTDS closed‐loop tests demonstrate that the proposed scheme exhibits both wide applicability across various scenarios and high sensitivity.
- 30 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (1) , 187-199
A Single-Ended Fault Detection Method Based on Active Boundary Control in Weak or Non-Boundary Scenarios
With the improvement of power electronic equipment, boundary components are gradually weakened or even eliminated, making it difficult to realize fault identification across the whole line solely based on single-ended electrical characteristics. Therefore, this paper introduces the concept of active boundaries, leveraging the high controllability of power electronic equipment to develop virtual diversion and suppression controls. These controls can help to amplify the differences between internal and external faults, effectively mitigating protection dead zones at the terminal of the line. Additionally, using the refraction coefficient as an indicator, the influence of equivalent resistance, inductance, and capacitance parameters of the converter is analyzed. Building on this, the energy ratio of high to low frequency band criterion considering frequency information is proposed to achieve single-ended whole-line protection in power electronic systems. The proposed scheme is validated using a multi-terminal hybrid HVDC transmission system model. Simulation results demonstrate that even in weak or non-boundary scenarios, the scheme can accurately identify faults across the whole line without relying on communication or coordination with other protection schemes, while maintaining high sensitivity and reliability.
- 30 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 41 (1) , 187-199
A Single-Ended Fault Detection Method Based on Active Boundary Control in Weak or Non-Boundary Scenarios
With the improvement of power electronic equipment, boundary components are gradually weakened or even eliminated, making it difficult to realize fault identification across the whole line solely based on single-ended electrical characteristics. Therefore, this paper introduces the concept of active boundaries, leveraging the high controllability of power electronic equipment to develop virtual diversion and suppression controls. These controls can help to amplify the differences between internal and external faults, effectively mitigating protection dead zones at the terminal of the line. Additionally, using the refraction coefficient as an indicator, the influence of equivalent resistance, inductance, and capacitance parameters of the converter is analyzed. Building on this, the energy ratio of high to low frequency band criterion considering frequency information is proposed to achieve single-ended whole-line protection in power electronic systems. The proposed scheme is validated using a multi-terminal hybrid HVDC transmission system model. Simulation results demonstrate that even in weak or non-boundary scenarios, the scheme can accurately identify faults across the whole line without relying on communication or coordination with other protection schemes, while maintaining high sensitivity and reliability.
- 12 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (3) , 5242-5250
Phase Current Based Fault Section Location for Single-Phase Grounding Fault in Non-Effectively Grounded Distribution Network
A novel single-phase grounding (SPG) fault detection and location methods in non-effectively grounded distribution network based on fault component of phase current is proposed in this paper. First, the fault component networks are built and transient characteristics of the fault components of phase current under SPG fault are analyzed based on the Karrenbauer Transformation. Then the SPG fault detection method based on the correlation coefficient of fault component of phase current measured by adjacent intelligent electronic devices (IEDs) is proposed and the section location methods based on intelligent distributed feeder automation mode and centralized feeder automation mode is proposed respectively. Finally, the proposed method is validated by simulation based on PSCAD and fault recording data. Results show that the proposed methods are feasible. Compared to zero-sequence voltage and current based SPG fault detection methods, the proposed method does not need zero-sequence current transformer and potential transformer. Besides, the proposed method can select the faulty phase automatically without using voltage signals.
- 12 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (3) , 5242-5250
Phase Current Based Fault Section Location for Single-Phase Grounding Fault in Non-Effectively Grounded Distribution Network
A novel single-phase grounding (SPG) fault detection and location methods in non-effectively grounded distribution network based on fault component of phase current is proposed in this paper. First, the fault component networks are built and transient characteristics of the fault components of phase current under SPG fault are analyzed based on the Karrenbauer Transformation. Then the SPG fault detection method based on the correlation coefficient of fault component of phase current measured by adjacent intelligent electronic devices (IEDs) is proposed and the section location methods based on intelligent distributed feeder automation mode and centralized feeder automation mode is proposed respectively. Finally, the proposed method is validated by simulation based on PSCAD and fault recording data. Results show that the proposed methods are feasible. Compared to zero-sequence voltage and current based SPG fault detection methods, the proposed method does not need zero-sequence current transformer and potential transformer. Besides, the proposed method can select the faulty phase automatically without using voltage signals.
- 25 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (5) , 2603-2615
Fault Location Method for MMC-HVDC Systems Based on Numerical Laplace Transform
Fault location plays a pivotal role in expediting the restoration of systems after faults. However, the necessity for rapid fault isolation in multi-terminal direct current (MTDC) systems dictates that only a few milliseconds of data are available for fault location. Therefore, accurately determining the fault location using an extreme short data window presents a challenge. To address this challenge, a frequency domain fault location method that utilizes data from both ends of lines is proposed. This method accurately considers frequency-dependent and distributed characteristics of line parameters and relies on data collected within 3 ms following a fault occurrence. Initially, the fault location equation is derived. Then, the numerical Laplace transform (NLT) method is introduced to solve this equation, from which the explicit expression for fault distance is obtained. Lastly, the comprehensive fault location scheme is outlined. Numerical simulations demonstrate that this method can accurately locate faults and exhibit good robustness against fault impedance. Additionally, the method features a reduced computational burden, higher accuracy, and stronger noise immunity compared to existing methods.
- 25 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (5) , 2603-2615
Fault Location Method for MMC-HVDC Systems Based on Numerical Laplace Transform
Fault location plays a pivotal role in expediting the restoration of systems after faults. However, the necessity for rapid fault isolation in multi-terminal direct current (MTDC) systems dictates that only a few milliseconds of data are available for fault location. Therefore, accurately determining the fault location using an extreme short data window presents a challenge. To address this challenge, a frequency domain fault location method that utilizes data from both ends of lines is proposed. This method accurately considers frequency-dependent and distributed characteristics of line parameters and relies on data collected within 3 ms following a fault occurrence. Initially, the fault location equation is derived. Then, the numerical Laplace transform (NLT) method is introduced to solve this equation, from which the explicit expression for fault distance is obtained. Lastly, the comprehensive fault location scheme is outlined. Numerical simulations demonstrate that this method can accurately locate faults and exhibit good robustness against fault impedance. Additionally, the method features a reduced computational burden, higher accuracy, and stronger noise immunity compared to existing methods.
- 12 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Frequency-Domain Fault Location Method for Underground Cables in MMC-HVdc Systems
Accurate fault location with a short data window is crucial and challenging for cable faults in the modular multilevel converter high voltage direct current (MMC-HVDC) system. Aiming at this issue, this paper proposes a frequency-domain fault location method, which accurately and comprehensively addresses the frequency dependency and unbalance of the parameter matrices without any approximation while considering the distributed parameters. Firstly, the frequency-domain decoupling is analyzed for DC cables with the metallic sheath and armor grounded at two terminals. Secondly, a method is proposed to calculate the voltage distribution along the cable using voltages and currents at one side of the cable based on the numerical Laplace transform (NLT). Subsequently, the cable parameter calculation method suitable for the NLT is presented, and a multi-round iterative algorithm for voltage distribution calculation is proposed. Ultimately, the complete fault location scheme is presented. Extensive simulations validate that the proposed method can achieve fault location with minor errors using a 20 kHz sampling rate and a 4 ms data window. Besides, high accuracy is maintained even under the influence of large fault impedance and noise. Compared to existing methods, the approach exhibits lower fault location error while requiring less computational complexity.
- 12 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Frequency-Domain Fault Location Method for Underground Cables in MMC-HVdc Systems
Accurate fault location with a short data window is crucial and challenging for cable faults in the modular multilevel converter high voltage direct current (MMC-HVDC) system. Aiming at this issue, this paper proposes a frequency-domain fault location method, which accurately and comprehensively addresses the frequency dependency and unbalance of the parameter matrices without any approximation while considering the distributed parameters. Firstly, the frequency-domain decoupling is analyzed for DC cables with the metallic sheath and armor grounded at two terminals. Secondly, a method is proposed to calculate the voltage distribution along the cable using voltages and currents at one side of the cable based on the numerical Laplace transform (NLT). Subsequently, the cable parameter calculation method suitable for the NLT is presented, and a multi-round iterative algorithm for voltage distribution calculation is proposed. Ultimately, the complete fault location scheme is presented. Extensive simulations validate that the proposed method can achieve fault location with minor errors using a 20 kHz sampling rate and a 4 ms data window. Besides, high accuracy is maintained even under the influence of large fault impedance and noise. Compared to existing methods, the approach exhibits lower fault location error while requiring less computational complexity.
- Open Access
- 8 April 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (8) , 1611-1623
A high speed and sensitive protection for distribution network with DGs using ferrite rings as line boundary
There exist problems of hard coordination and threshold setting as well as low sensitivity in overcurrent relay due to the bidirectional and small fault current when distributed generators are integrated into the distribution network. This paper introduces ferrite rings (FRs) to act as boundaries of distribution feeders, and a peak time of voltage traveling wave‐based protection is proposed. The characteristics of FRs are analyzed and their feasibility as line boundary is validated. The fault characteristics of internal and external faults are analyzed when FRs are installed at both ends of the protected feeder. The results show that the peak time of the voltage travelling wave of the internal fault is far smaller than that of the external faults. According to the difference, the fault detection method and the protection scheme are proposed. Simulations in PSCAD and experiment validate that the proposed protection principle can reliably distinguish between internal and external faults. Besides, the proposed protection scheme has higher sensitivity compared to ROCOV‐based protection.
- 8 April 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (8) , 1611-1623
Open AccessA high speed and sensitive protection for distribution network with DGs using ferrite rings as line boundary
There exist problems of hard coordination and threshold setting as well as low sensitivity in overcurrent relay due to the bidirectional and small fault current when distributed generators are integrated into the distribution network. This paper introduces ferrite rings (FRs) to act as boundaries of distribution feeders, and a peak time of voltage traveling wave‐based protection is proposed. The characteristics of FRs are analyzed and their feasibility as line boundary is validated. The fault characteristics of internal and external faults are analyzed when FRs are installed at both ends of the protected feeder. The results show that the peak time of the voltage travelling wave of the internal fault is far smaller than that of the external faults. According to the difference, the fault detection method and the protection scheme are proposed. Simulations in PSCAD and experiment validate that the proposed protection principle can reliably distinguish between internal and external faults. Besides, the proposed protection scheme has higher sensitivity compared to ROCOV‐based protection.