Jifei Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jifei Yan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Chenhao Zhang
School of Electrical Engineering, Xian Jiaotong University, Xian, China
7 shared publications - Guobing Song
School of Electrical Engineering, Xian Jiaotong University, Xian, China
7 shared publications Guobing Song
5 shared publications- Xiaoping Gao
School of Electrical Engineering, Xian Jiaotong University, Xian, China
5 shared publications - Zhongxue Chang
School of Electrical Engineering, Xian Jiaotong University, Xian, Shaanxi, China
4 shared publications Zhongxue Chang
3 shared publications
Latest Publications
- 9 October 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
A single-ended fault location method based on active boundary control for multi-terminal flexible DC grids
- 9 October 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
A single-ended fault location method based on active boundary control for multi-terminal flexible DC grids
- 17 September 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Line-model consistency based pilot protection for renewable energy lines
- 17 September 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Line-model consistency based pilot protection for renewable energy lines
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (4) , 2760-2776
A Single-Ended Whole-Line Protection for Active Distribution Networks Using Constructed Resonant Boundary Element
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (4) , 2760-2776
A Single-Ended Whole-Line Protection for Active Distribution Networks Using Constructed Resonant Boundary Element
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70436
Unsynchronized Two‐Terminal Transmission Line Fault Location Method Based on Traveling‐Wave Attenuation
In transmission lines, fault‐induced traveling waves (TWs) carry fault‐location information through both propagation delay and amplitude attenuation. Conventional two‐terminal TW‐based fault‐location methods commonly exploit the propagation delay of fault‐induced TWs to estimate the fault distance. However, the performance of such methods usually depends on precise time synchronization and accurate wavefront identification, and may be degraded by Global Positioning System (GPS) timing errors, wavefront distortion, and noise interference. To address this problem, this paper proposes an unsynchronized two‐terminal fault location method based on TW amplitude attenuation, in which the propagation relationship between the two terminal responses is established in the frequency domain. Vector fitting is then used to approximate the propagation function, which is further converted into a time‐domain recursive convolution model. The fault distance is determined by identifying the location at which the calculated terminal response best matches the measured TW signal. Simulation results demonstrate that the proposed method achieves high location accuracy and good robustness under various fault locations, fault types, transition resistances, noise levels, and sampling frequencies.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70436
Open AccessUnsynchronized Two‐Terminal Transmission Line Fault Location Method Based on Traveling‐Wave Attenuation
In transmission lines, fault‐induced traveling waves (TWs) carry fault‐location information through both propagation delay and amplitude attenuation. Conventional two‐terminal TW‐based fault‐location methods commonly exploit the propagation delay of fault‐induced TWs to estimate the fault distance. However, the performance of such methods usually depends on precise time synchronization and accurate wavefront identification, and may be degraded by Global Positioning System (GPS) timing errors, wavefront distortion, and noise interference. To address this problem, this paper proposes an unsynchronized two‐terminal fault location method based on TW amplitude attenuation, in which the propagation relationship between the two terminal responses is established in the frequency domain. Vector fitting is then used to approximate the propagation function, which is further converted into a time‐domain recursive convolution model. The fault distance is determined by identifying the location at which the calculated terminal response best matches the measured TW signal. Simulation results demonstrate that the proposed method achieves high location accuracy and good robustness under various fault locations, fault types, transition resistances, noise levels, and sampling frequencies.
- 16 September 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 251
A Frequency-domain pilot protection method considering instrument transformer characteristics
- 16 September 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 251
A Frequency-domain pilot protection method considering instrument transformer characteristics
- 6 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (2) , 1143-1157
Single-Ended Remote Backup Protection Based on Fault Distance Factor of Traveling Wavefront
Zone III distance protection has long operating time and its sensitivity decreases significantly in renewable energy scenarios. In this paper, novel single-ended remote backup protection is proposed based on fault location information contained in traveling wavefront. Firstly, it is demonstrated that the fault distance factor of traveling wavefront is effective in reflecting location of fault in both radial and meshed topologies. Then fault distance-operating time inverse-time characteristic is designed based on fault distance factor, realizing spontaneous sequencing of operating time between the relays at higher and lower zones. This inverse-time characteristic is only determined by location of fault and not influenced by operation mode, control strategy, fault type, fault resistance, etc. A robust algorithm is proposed to efficiently extract the fault distance factor, ensuring protection reliability. Resetting criterions are designed to re-check the existence of fault, avoiding leapfrog tripping and maloperation confronting disturbances. The setting of proposed protection is simple, without the need to update the threshold value according to the system status. Verifications have demonstrated that the proposed protection can be self-adaptive to flexible operation mode of renewable energy transmission system and different topologies. The proposed method also demonstrates high tolerance to fault resistance and noise while maintaining fast operating speed.
- 6 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (2) , 1143-1157
Single-Ended Remote Backup Protection Based on Fault Distance Factor of Traveling Wavefront
Zone III distance protection has long operating time and its sensitivity decreases significantly in renewable energy scenarios. In this paper, novel single-ended remote backup protection is proposed based on fault location information contained in traveling wavefront. Firstly, it is demonstrated that the fault distance factor of traveling wavefront is effective in reflecting location of fault in both radial and meshed topologies. Then fault distance-operating time inverse-time characteristic is designed based on fault distance factor, realizing spontaneous sequencing of operating time between the relays at higher and lower zones. This inverse-time characteristic is only determined by location of fault and not influenced by operation mode, control strategy, fault type, fault resistance, etc. A robust algorithm is proposed to efficiently extract the fault distance factor, ensuring protection reliability. Resetting criterions are designed to re-check the existence of fault, avoiding leapfrog tripping and maloperation confronting disturbances. The setting of proposed protection is simple, without the need to update the threshold value according to the system status. Verifications have demonstrated that the proposed protection can be self-adaptive to flexible operation mode of renewable energy transmission system and different topologies. The proposed method also demonstrates high tolerance to fault resistance and noise while maintaining fast operating speed.
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (1) , 273-286
A Novel Directional Pilot Protection of Submarine Cables for Low Frequency Transmission System With Offshore Wind Power
Low frequency transmission system (LFTS) has become a competitive method for long-distance offshore wind power transmission. However, traditional protections based on the fundamental frequency phasor may have poor performance since both ends of submarine cables connect with power electronic devices. First, the adaptability of traditional protections is analyzed. It is found that fault characteristics are weakened by typical control strategies. To enhance the characteristic difference between internal and external faults, an impedance construction method for grid-side converter (GSC) and modular multilevel matrix converter (M3C) is proposed. Then this paper proposes a directional pilot protection. For asymmetrical faults, the angle of negative-sequence impedance of GSC and M3C is determined by references of current loop controller. For symmetrical faults, adjusting coefficients of current loop reference in GSC helps the protection perform well under high-resistance faults. Building the sequence networks under different fault types, a phase selection method based on voltage magnitude is proposed. Finally, simulation tests are conducted in PSCAD/EMTDC, and the results demonstrate that the proposed impedance construction method can provide effective support for fault identification and the proposed protection performs well under various fault scenarios.
- 7 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (1) , 273-286
A Novel Directional Pilot Protection of Submarine Cables for Low Frequency Transmission System With Offshore Wind Power
Low frequency transmission system (LFTS) has become a competitive method for long-distance offshore wind power transmission. However, traditional protections based on the fundamental frequency phasor may have poor performance since both ends of submarine cables connect with power electronic devices. First, the adaptability of traditional protections is analyzed. It is found that fault characteristics are weakened by typical control strategies. To enhance the characteristic difference between internal and external faults, an impedance construction method for grid-side converter (GSC) and modular multilevel matrix converter (M3C) is proposed. Then this paper proposes a directional pilot protection. For asymmetrical faults, the angle of negative-sequence impedance of GSC and M3C is determined by references of current loop controller. For symmetrical faults, adjusting coefficients of current loop reference in GSC helps the protection perform well under high-resistance faults. Building the sequence networks under different fault types, a phase selection method based on voltage magnitude is proposed. Finally, simulation tests are conducted in PSCAD/EMTDC, and the results demonstrate that the proposed impedance construction method can provide effective support for fault identification and the proposed protection performs well under various fault scenarios.
- 25 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (5) , 2603-2615
Fault Location Method for MMC-HVDC Systems Based on Numerical Laplace Transform
Fault location plays a pivotal role in expediting the restoration of systems after faults. However, the necessity for rapid fault isolation in multi-terminal direct current (MTDC) systems dictates that only a few milliseconds of data are available for fault location. Therefore, accurately determining the fault location using an extreme short data window presents a challenge. To address this challenge, a frequency domain fault location method that utilizes data from both ends of lines is proposed. This method accurately considers frequency-dependent and distributed characteristics of line parameters and relies on data collected within 3 ms following a fault occurrence. Initially, the fault location equation is derived. Then, the numerical Laplace transform (NLT) method is introduced to solve this equation, from which the explicit expression for fault distance is obtained. Lastly, the comprehensive fault location scheme is outlined. Numerical simulations demonstrate that this method can accurately locate faults and exhibit good robustness against fault impedance. Additionally, the method features a reduced computational burden, higher accuracy, and stronger noise immunity compared to existing methods.
- 25 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (5) , 2603-2615
Fault Location Method for MMC-HVDC Systems Based on Numerical Laplace Transform
Fault location plays a pivotal role in expediting the restoration of systems after faults. However, the necessity for rapid fault isolation in multi-terminal direct current (MTDC) systems dictates that only a few milliseconds of data are available for fault location. Therefore, accurately determining the fault location using an extreme short data window presents a challenge. To address this challenge, a frequency domain fault location method that utilizes data from both ends of lines is proposed. This method accurately considers frequency-dependent and distributed characteristics of line parameters and relies on data collected within 3 ms following a fault occurrence. Initially, the fault location equation is derived. Then, the numerical Laplace transform (NLT) method is introduced to solve this equation, from which the explicit expression for fault distance is obtained. Lastly, the comprehensive fault location scheme is outlined. Numerical simulations demonstrate that this method can accurately locate faults and exhibit good robustness against fault impedance. Additionally, the method features a reduced computational burden, higher accuracy, and stronger noise immunity compared to existing methods.
- 12 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Frequency-Domain Fault Location Method for Underground Cables in MMC-HVdc Systems
Accurate fault location with a short data window is crucial and challenging for cable faults in the modular multilevel converter high voltage direct current (MMC-HVDC) system. Aiming at this issue, this paper proposes a frequency-domain fault location method, which accurately and comprehensively addresses the frequency dependency and unbalance of the parameter matrices without any approximation while considering the distributed parameters. Firstly, the frequency-domain decoupling is analyzed for DC cables with the metallic sheath and armor grounded at two terminals. Secondly, a method is proposed to calculate the voltage distribution along the cable using voltages and currents at one side of the cable based on the numerical Laplace transform (NLT). Subsequently, the cable parameter calculation method suitable for the NLT is presented, and a multi-round iterative algorithm for voltage distribution calculation is proposed. Ultimately, the complete fault location scheme is presented. Extensive simulations validate that the proposed method can achieve fault location with minor errors using a 20 kHz sampling rate and a 4 ms data window. Besides, high accuracy is maintained even under the influence of large fault impedance and noise. Compared to existing methods, the approach exhibits lower fault location error while requiring less computational complexity.
- 12 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Frequency-Domain Fault Location Method for Underground Cables in MMC-HVdc Systems
Accurate fault location with a short data window is crucial and challenging for cable faults in the modular multilevel converter high voltage direct current (MMC-HVDC) system. Aiming at this issue, this paper proposes a frequency-domain fault location method, which accurately and comprehensively addresses the frequency dependency and unbalance of the parameter matrices without any approximation while considering the distributed parameters. Firstly, the frequency-domain decoupling is analyzed for DC cables with the metallic sheath and armor grounded at two terminals. Secondly, a method is proposed to calculate the voltage distribution along the cable using voltages and currents at one side of the cable based on the numerical Laplace transform (NLT). Subsequently, the cable parameter calculation method suitable for the NLT is presented, and a multi-round iterative algorithm for voltage distribution calculation is proposed. Ultimately, the complete fault location scheme is presented. Extensive simulations validate that the proposed method can achieve fault location with minor errors using a 20 kHz sampling rate and a 4 ms data window. Besides, high accuracy is maintained even under the influence of large fault impedance and noise. Compared to existing methods, the approach exhibits lower fault location error while requiring less computational complexity.