Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sebastiaan Eckhardt Dulfer has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Anthony Ray Absalom

    Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands

    5 shared publications
  • G. Drost

    Department of Neurosurgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands; Department of Neurology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands

    5 shared publications
  • Fiete Lange

    Amyloidosis Center of Expertise, University Medical Center Groningen, 9700 RB Groningen, The Netherlands

    4 shared publications
  • Rob J. M. Groen

    Department of Neurology, University Medical Center Groningen, Groningen, The Netherlands

    4 shared publications
  • C. Faber

    Department of Orthopedics, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands

    3 shared publications
  • F. H. Wapstra

    Department of Orthopedics, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands

    3 shared publications

Latest Publications

  • Open Access

    The Association of Physiological and Pharmacological Anesthetic Parameters With Motor-Evoked Potentials: A Multivariable Longitudinal Mixed Model Analysis

    by Sebastiaan Eckhardt Dulfer, Henk Groen, Robertus J. M. Groen, Anthony R. Absalom, Marko M. Sahinovic, Gea Drost

    BACKGROUND: During spinal surgery, the motor tracts can be monitored using muscle-recorded transcranial electrical stimulation motor-evoked potentials (mTc-MEPs). We aimed to investigate the association of anesthetic and physiological parameters with mTc-MEPs. METHODS: Intraoperative mTc-MEP amplitudes, mTc-MEP area under the curves (AUC), and anesthetic and physiological measurements were collected retrospectively from the records of 108 consecutive patients undergoing elective spinal surgery. Pharmacological parameters of interest included propofol and opioid concentration, ketamine and noradrenaline infusion rates. Physiological parameters recorded included mean arterial pressure (MAP), bispectral index (BIS), heart rate, hemoglobin O 2 saturation, temperature, and Et co 2 . A forward selection procedure was performed using multivariable mixed model analysis. RESULTS: Data from 75 (69.4%) patients were included. MAP and BIS were significantly associated with mTc-MEP amplitude ( P < .001). mTc-MEP amplitudes increased by 6.6% (95% confidence interval [CI], 2.7%–10.4%) per 10 mm Hg increase in MAP and by 2.79% (CI, 2.26%–3.32%) for every unit increase in BIS. MAP ( P < .001), BIS ( P < .001), heart rate ( P = .01), and temperature ( P = .02) were significantly associated with mTc-MEP AUC. The AUC increased by 7.5% (CI, 3.3%–11.7%) per 10 mm Hg increase of MAP, by 2.98% (CI, 2.41%–3.54%) per unit increase in BIS, and by 0.68% (CI, 0.13%–1.23%) per beat per minute increase in heart rate. mTc-MEP AUC decreased by 21.4% (CI, −38.11% to −3.98%) per degree increase in temperature. CONCLUSIONS: MAP, BIS, heart rate, and temperature were significantly associated with mTc-MEP amplitude and/or AUC. Maintenance of BIS and MAP at the high normal values may attenuate anesthetic effects on mTc-MEPs.


  • Reply to “Review on MEP monitoring disregarding D-wave references”

    by S.E. Dulfer, M.C. Gadella, M.M. Sahinovic, F. Lange, A.R. Absalom, R.J.M. Groen, A. Szelényi, G. Drost

  • Open Access

    Stimulation parameters for motor evoked potentials during intraoperative spinal cord monitoring. A systematic review

    by S.E. Dulfer, M.C. Gadella, M.M. Sahinovic, F. Lange, A.R. Absalom, R.J.M. Groen, A. Szelényi, G. Drost


  • Open Access

    Use of NEedle Versus suRFACE Recording Electrodes for Detection of Intraoperative Motor Warnings: A Non-Inferiority Trial. The NERFACE Study Part II

    by Sebastiaan E. Dulfer, Maria C. Gadella, Katalin Tamási, Anthony R. Absalom, Fiete Lange, Carola H. M. Scholtens-Henzen, Christopher Faber, Frits H. Wapstra, Rob J. M. Groen, Marko M. Sahinovic, et al.

    In the NERFACE study part I, the characteristics of muscle transcranial electrical stimulation motor evoked potentials (mTc-MEPs) recorded from the tibialis anterior (TA) muscles with surface and subcutaneous needle electrodes were compared. The aim of this study (NERFACE part II) was to investigate whether the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes in detecting mTc-MEP warnings during spinal cord monitoring. mTc-MEPs were simultaneously recorded from TA muscles with surface and subcutaneous needle electrodes. Monitoring outcomes (no warning, reversible warning, irreversible warning, complete loss of mTc-MEP amplitude) and neurological outcomes (no, transient, or permanent new motor deficits) were collected. The non-inferiority margin was 5%. In total, 210 (86.8%) out of 242 consecutive patients were included. There was a perfect agreement between both recording electrode types for the detection of mTc-MEP warnings. For both electrode types, the proportion of patients with a warning was 0.12 (25/210) (difference, 0.0% (one-sided 95% CI, 0.014)), indicating non-inferiority of the surface electrode. Moreover, reversible warnings for both electrode types were never followed by permanent new motor deficits, whereas among the 10 patients with irreversible warnings or complete loss of amplitude, more than half developed transient or permanent new motor deficits. In conclusion, the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes for the detection of mTc-MEP warnings recorded over the TA muscles.


  • Open Access

    Comparing Motor-Evoked Potential Characteristics of NEedle versus suRFACE Recording Electrodes during Spinal Cord Monitoring—The NERFACE Study Part I

    by Maria C. Gadella, Sebastiaan E. Dulfer, Anthony R. Absalom, Fiete Lange, Carola H. M. Scholtens-Henzen, Rob J. M. Groen, Frits H. Wapstra, Christopher Faber, Katalin Tamási, Marko M. Sahinovic, et al.

    Muscle-recorded transcranial electrical stimulation motor-evoked potentials (mTc-MEPs) are used to assess the spinal cord integrity. They are commonly recorded with subcutaneous needle or surface electrodes, but the different characteristics of mTc-MEP signals recorded with the two types of electrodes have not been formally compared yet. In this study, mTc-MEPs were simultaneously recorded from the tibialis anterior (TA) muscles using surface and subcutaneous needle electrodes in 242 consecutive patients. Elicitability, motor thresholds, amplitude, area under the curve (AUC), signal-to-noise ratio (SNR), and the variability between mTc-MEP amplitudes were compared. Whereas amplitude and AUC were significantly higher in subcutaneous needle recordings (p < 0.01), motor thresholds and elicitability were similar for surface and subcutaneous needle recordings. Moreover, the SNRs were >2 in more than 99.5% of the surface and subcutaneous needle recordings, and the variability between consecutive amplitudes was not significantly different between the two recording electrode types (p = 0.34). Surface electrodes appear to be a good alternative to needle electrodes for spinal cord monitoring. They are non-invasive, can record signals at similar threshold intensities, have adequately high SNRs, and record signals with equivalent variability. Whether surface electrodes are non-inferior to subcutaneous needle electrodes in detecting motor warnings is investigated in part II of the NERFACE study.


  • Open Access

    Feasibility and optimal choice of stimulation parameters for supramaximal stimulation of motor evoked potentials

    by S. E. Dulfer, F. Lange, M. M. Sahinovic, F. H. Wapstra, A. R. Absalom, C. Faber, R. J.M. Groen, G. Drost

    Purpose: The aim was to investigate the feasibility and optimal stimulation parameters for supramaximal stimulation of muscle recorded transcranial electrical stimulation motor evoked potentials (mTc-MEP). Methods: Forty-seven consecutive patients that underwent scoliosis surgery were included. First, the feasibility of supramaximal stimulation was assessed for two settings (setting 1: pulse duration 0.075ms, interstimulus interval (ISI) 1.5ms; setting 2: pulse duration 0.300ms, ISI 3ms). Thereafter, three mTc-MEP parameters were considered for both settings; (1) elicitability, (2) amplitude, and (3) if supramaximal stimulation was achieved with ≥ 20 V below maximum output. Finally, ISIs (1ms–4ms) were optimized for setting 1. Results: Nine patients (19.15%) were excluded. Of the remaining patients, supramaximal stimulation was achieved in all patients for setting 1, and in 26 (68.42%) for setting 2. In one patient, mTc-MEPs were elicitable in more muscles for setting (1) Amplitudes were not significantly different. Stimulation voltage could be increased ≥ 20 V in all 38 patients for setting 1 and in 10 (38.46%) for setting (2) Optimal ISI’s differed widely. Conclusion: We recommend using setting 1 when monitoring mTc-MEPs with supramaximal stimulation, after which an individualized ISI optimization can be performed. Moreover, when using supramaximal stimulation, short ISI’s (i.e. 1ms or 1.5ms) can be the optimal ISI for obtaining the highest mTc-MEP amplitude.


  • Open Access

    The influence of depth of anesthesia and blood pressure on muscle recorded motor evoked potentials in spinal surgery. A prospective observational study protocol

    by Sebastiaan E. Dulfer, M. M. Sahinovic, F. Lange, F. H. Wapstra, D. Postmus, A. R. E. Potgieser, C. Faber, R. J. M. Groen, A. R. Absalom, G. Drost

    For high-risk spinal surgeries, intraoperative neurophysiological monitoring (IONM) is used to detect and prevent intraoperative neurological injury. The motor tracts are monitored by recording and analyzing muscle transcranial electrical stimulation motor evoked potentials (mTc-MEPs). A mTc-MEP amplitude decrease of 50–80% is the most common warning criterion for possible neurological injury. However, these warning criteria often result in false positive warnings. False positives may be caused by inadequate depth of anesthesia and blood pressure on mTc-MEP amplitudes. The aim of this paper is to validate the study protocol in which the goal is to investigate the effects of depth of anesthesia (part 1) and blood pressure (part 2) on mTc-MEPs. Per part, 25 patients will be included. In order to investigate the effects of depth of anesthesia, a processed electroencephalogram (pEEG) monitor will be used. At pEEG values of 30, 40 and 50, mTc-MEP measurements will be performed. To examine the effect of blood pressure on mTc-MEPs the mean arterial pressure will be elevated from 60 to 100 mmHg during which mTc-MEP measurements will be performed. We hypothesize that by understanding the effects of depth of anesthesia and blood pressure on mTc-MEPs, the mTc-MEP monitoring can be interpreted more reliably. This may contribute to fewer false positive warnings. By performing this study after induction and prior to incision, this protocol provides a unique opportunity to study the effects of depths of anesthesia and blood pressure on mTc-MEPs alone with as little confounders as possible.Trial registration numberNL7772.


  • Open Access

    Intraoperative neurophysiological monitoring during scoliosis surgery in patients with Duchenne muscular dystrophy

    by S. E. Dulfer, F. Lange, F. H. Wapstra, A. R. E. Potgieser, J. P. Valk, A. R. Absalom, R. J. M. Groen, C. Faber, G. Drost

    Purpose: Little is known about the reliability and value of intraoperative neurophysiological monitoring (IONM) in patients with Duchenne muscular dystrophy (DMD) undergoing scoliosis correction surgery. The aim of this study was to investigate the feasibility of IONM and the cortical excitability in these patients. Methods: Fifteen patients with DMD and scoliosis and 15 patients with adolescent idiopathic scoliosis (AIS) underwent scoliosis correction surgery with the use of IONM. IONM consisted of transcranial electrical stimulation motor evoked potential (Tc-MEP) and somatosensory evoked potential (SSEP) monitoring. The highest Tc-MEP amplitudes were collected to test the feasibility. Preoperative compound muscle action potentials (CMAPs) and transcranial magnetic stimulation (TMS)-MEPs were recorded to test the cortical excitability. SSEPs were scored as elicitable or not elicitable. Results: Tc-MEP amplitudes were significantly lower in the DMD group for both the gastrocnemius and tibialis anterior muscles. However, the abductor hallucis muscle had similar amplitudes in both the DMD as the AIS group. TMS/CMAP and Tc-MEP/CMAP ratios were similar in the DMD and AIS group (P = 0.126 and P = 0.792 respectively). Conclusions: Tc-MEP and SSEP monitoring is feasible, particularly when Tc-MEPs are recorded from the abductor hallucis muscle in patients with DMD. Similar TMS/CMAP and Tc-MEP/CMAP ratios show that there were no differences observed in cortical excitability between the groups. IONM seems a feasible and valuable neurophysiological tool to signal possible surgically induced damage to the spinal cord during scoliosis correction surgery in patients with DMD.