Fiete Lange
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fiete Lange has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Anthony Ray Absalom
Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
5 shared publications - Gea Drost
Department of Neurosurgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
5 shared publications - Maria C. Gadella
Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
4 shared publications - Rob J. M. Groen
Department of Neurology, University Medical Center Groningen, Groningen, The Netherlands
4 shared publications - Sebastiaan Eckhardt Dulfer
Department of Neurosurgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
4 shared publications - Katalin Tamási
Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
3 shared publications
Latest Publications
- Open Access
- 4 March 2026
- Published by Elsevier in Clinical Neurophysiology
- Vol. 186, 2111726
Characteristics and effects of depth of anaesthesia on late motor responses
- 4 March 2026
- Published by Elsevier in Clinical Neurophysiology
- Vol. 186, 2111726
Open AccessCharacteristics and effects of depth of anaesthesia on late motor responses
- Open Access
- 28 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (5) , 1862
Exploratory Evaluation of the Predictive Value of Serum Neurofilament Light Chain for Autonomic Neuropathy in Hereditary Transthyretin Amyloidosis
Background/Objectives: Serum neurofilament light chain (sNfL) is a biomarker for peripheral neuropathy as sNfL correlates with polyneuropathy severity in hereditary transthyretin (ATTRv) amyloidosis. It is unclear whether sNfL also correlates with autonomic neuropathy (ANP). In this exploratory study, we aimed to evaluate the value of sNfL as marker for ANP in patients with ATTRv amyloidosis. Methods: sNfL was measured retrospectively in 10 pathogenic transthyretin gene variant (TTRv) carriers and 28 patients with ATTRv amyloidosis. All 38 individuals underwent a comprehensive evaluation for ANP. Results: Individuals with ANP had a higher median sNfL level compared to those without ANP (p < 0.001). In univariable logistic regression analysis, age-adjusted sNfL status (normal versus abnormal for age) was associated with sex, ANP, and peripheral neuropathy. In multivariable logistic regression analysis, only peripheral neuropathy significantly predicted age-adjusted sNfL status (normal versus abnormal for age), and no signal was detected for ANP. Receiver operating characteristic analysis showed a considerable area under the curve for ANP. However, the confidence interval was wide for both analyses and only four cases with isolated ANP were included. Conclusions: Therefore, in this exploratory cohort, sNfL could not be identified as a marker for ANP, and larger studies are needed to clarify its value.
- 28 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (5) , 1862
Open AccessExploratory Evaluation of the Predictive Value of Serum Neurofilament Light Chain for Autonomic Neuropathy in Hereditary Transthyretin Amyloidosis
Background/Objectives: Serum neurofilament light chain (sNfL) is a biomarker for peripheral neuropathy as sNfL correlates with polyneuropathy severity in hereditary transthyretin (ATTRv) amyloidosis. It is unclear whether sNfL also correlates with autonomic neuropathy (ANP). In this exploratory study, we aimed to evaluate the value of sNfL as marker for ANP in patients with ATTRv amyloidosis. Methods: sNfL was measured retrospectively in 10 pathogenic transthyretin gene variant (TTRv) carriers and 28 patients with ATTRv amyloidosis. All 38 individuals underwent a comprehensive evaluation for ANP. Results: Individuals with ANP had a higher median sNfL level compared to those without ANP (p < 0.001). In univariable logistic regression analysis, age-adjusted sNfL status (normal versus abnormal for age) was associated with sex, ANP, and peripheral neuropathy. In multivariable logistic regression analysis, only peripheral neuropathy significantly predicted age-adjusted sNfL status (normal versus abnormal for age), and no signal was detected for ANP. Receiver operating characteristic analysis showed a considerable area under the curve for ANP. However, the confidence interval was wide for both analyses and only four cases with isolated ANP were included. Conclusions: Therefore, in this exploratory cohort, sNfL could not be identified as a marker for ANP, and larger studies are needed to clarify its value.
- Open Access
- 14 November 2025
- Published by MDPI AG in Preprints.org
Serum Neurofilament Light Chain Is Not an Independent Predictor of Autonomic Neuropathy in Hereditary Transthyretin Amyloidosis
Serum neurofilament light chain (sNfL) is a biomarker for peripheral neuropathy as sNfL correlates with polyneuropathy severity in hereditary transthyretin (ATTRv) amyloidosis. It is unclear whether sNfL also correlates with autonomic neuropathy. In this study, we aimed to predict the presence of autonomic neuropathy in patients with ATTRv amyloidosis based on sNfL levels. sNfL was measured retrospectively in 10 pathogenic transthyretin gene variant (TTRv) carriers and 28 patients with ATTRv amyloidosis. All 38 individuals underwent a comprehensive evaluation for autonomic neuropathy. Individuals with autonomic neuropathy had a higher median sNfL level compared to those without autonomic neuropathy (p< 0.001). In univariable logistic regression analysis, age-adjusted sNfL status (normal versus abnormal for age) was associated with sex, autonomic neuropathy, and peripheral neuropathy. In multivariable logistic regression analysis, only peripheral neuropathy remained the independent predictor of age-adjusted sNfL status (normal versus abnormal for age). Abnormal age-adjusted sNfL status was associated with autonomic neuropathy, but only peripheral neuropathy independently predicted abnormal sNfL status in TTRv carriers and ATTRv amyloidosis patients.
- 14 November 2025
- Published by MDPI AG in Preprints.org
Open AccessSerum Neurofilament Light Chain Is Not an Independent Predictor of Autonomic Neuropathy in Hereditary Transthyretin Amyloidosis
Serum neurofilament light chain (sNfL) is a biomarker for peripheral neuropathy as sNfL correlates with polyneuropathy severity in hereditary transthyretin (ATTRv) amyloidosis. It is unclear whether sNfL also correlates with autonomic neuropathy. In this study, we aimed to predict the presence of autonomic neuropathy in patients with ATTRv amyloidosis based on sNfL levels. sNfL was measured retrospectively in 10 pathogenic transthyretin gene variant (TTRv) carriers and 28 patients with ATTRv amyloidosis. All 38 individuals underwent a comprehensive evaluation for autonomic neuropathy. Individuals with autonomic neuropathy had a higher median sNfL level compared to those without autonomic neuropathy (p< 0.001). In univariable logistic regression analysis, age-adjusted sNfL status (normal versus abnormal for age) was associated with sex, autonomic neuropathy, and peripheral neuropathy. In multivariable logistic regression analysis, only peripheral neuropathy remained the independent predictor of age-adjusted sNfL status (normal versus abnormal for age). Abnormal age-adjusted sNfL status was associated with autonomic neuropathy, but only peripheral neuropathy independently predicted abnormal sNfL status in TTRv carriers and ATTRv amyloidosis patients.
- 15 May 2023
- Published by Elsevier in Clinical Neurophysiology
- Vol. 152, 114
Reply to “Review on MEP monitoring disregarding D-wave references”
- 15 May 2023
- Published by Elsevier in Clinical Neurophysiology
- Vol. 152, 114
Reply to “Review on MEP monitoring disregarding D-wave references”
- Open Access
- 3 March 2023
- Published by Elsevier in Clinical Neurophysiology
- Vol. 149, 70-80
Stimulation parameters for motor evoked potentials during intraoperative spinal cord monitoring. A systematic review
- 3 March 2023
- Published by Elsevier in Clinical Neurophysiology
- Vol. 149, 70-80
Open AccessStimulation parameters for motor evoked potentials during intraoperative spinal cord monitoring. A systematic review
- Open Access
- 22 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (5) , 1753
Use of NEedle Versus suRFACE Recording Electrodes for Detection of Intraoperative Motor Warnings: A Non-Inferiority Trial. The NERFACE Study Part II
In the NERFACE study part I, the characteristics of muscle transcranial electrical stimulation motor evoked potentials (mTc-MEPs) recorded from the tibialis anterior (TA) muscles with surface and subcutaneous needle electrodes were compared. The aim of this study (NERFACE part II) was to investigate whether the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes in detecting mTc-MEP warnings during spinal cord monitoring. mTc-MEPs were simultaneously recorded from TA muscles with surface and subcutaneous needle electrodes. Monitoring outcomes (no warning, reversible warning, irreversible warning, complete loss of mTc-MEP amplitude) and neurological outcomes (no, transient, or permanent new motor deficits) were collected. The non-inferiority margin was 5%. In total, 210 (86.8%) out of 242 consecutive patients were included. There was a perfect agreement between both recording electrode types for the detection of mTc-MEP warnings. For both electrode types, the proportion of patients with a warning was 0.12 (25/210) (difference, 0.0% (one-sided 95% CI, 0.014)), indicating non-inferiority of the surface electrode. Moreover, reversible warnings for both electrode types were never followed by permanent new motor deficits, whereas among the 10 patients with irreversible warnings or complete loss of amplitude, more than half developed transient or permanent new motor deficits. In conclusion, the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes for the detection of mTc-MEP warnings recorded over the TA muscles.
- 22 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (5) , 1753
Open AccessUse of NEedle Versus suRFACE Recording Electrodes for Detection of Intraoperative Motor Warnings: A Non-Inferiority Trial. The NERFACE Study Part II
In the NERFACE study part I, the characteristics of muscle transcranial electrical stimulation motor evoked potentials (mTc-MEPs) recorded from the tibialis anterior (TA) muscles with surface and subcutaneous needle electrodes were compared. The aim of this study (NERFACE part II) was to investigate whether the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes in detecting mTc-MEP warnings during spinal cord monitoring. mTc-MEPs were simultaneously recorded from TA muscles with surface and subcutaneous needle electrodes. Monitoring outcomes (no warning, reversible warning, irreversible warning, complete loss of mTc-MEP amplitude) and neurological outcomes (no, transient, or permanent new motor deficits) were collected. The non-inferiority margin was 5%. In total, 210 (86.8%) out of 242 consecutive patients were included. There was a perfect agreement between both recording electrode types for the detection of mTc-MEP warnings. For both electrode types, the proportion of patients with a warning was 0.12 (25/210) (difference, 0.0% (one-sided 95% CI, 0.014)), indicating non-inferiority of the surface electrode. Moreover, reversible warnings for both electrode types were never followed by permanent new motor deficits, whereas among the 10 patients with irreversible warnings or complete loss of amplitude, more than half developed transient or permanent new motor deficits. In conclusion, the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes for the detection of mTc-MEP warnings recorded over the TA muscles.
- Open Access
- 10 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1404
Comparing Motor-Evoked Potential Characteristics of NEedle versus suRFACE Recording Electrodes during Spinal Cord Monitoring—The NERFACE Study Part I
Muscle-recorded transcranial electrical stimulation motor-evoked potentials (mTc-MEPs) are used to assess the spinal cord integrity. They are commonly recorded with subcutaneous needle or surface electrodes, but the different characteristics of mTc-MEP signals recorded with the two types of electrodes have not been formally compared yet. In this study, mTc-MEPs were simultaneously recorded from the tibialis anterior (TA) muscles using surface and subcutaneous needle electrodes in 242 consecutive patients. Elicitability, motor thresholds, amplitude, area under the curve (AUC), signal-to-noise ratio (SNR), and the variability between mTc-MEP amplitudes were compared. Whereas amplitude and AUC were significantly higher in subcutaneous needle recordings (p < 0.01), motor thresholds and elicitability were similar for surface and subcutaneous needle recordings. Moreover, the SNRs were >2 in more than 99.5% of the surface and subcutaneous needle recordings, and the variability between consecutive amplitudes was not significantly different between the two recording electrode types (p = 0.34). Surface electrodes appear to be a good alternative to needle electrodes for spinal cord monitoring. They are non-invasive, can record signals at similar threshold intensities, have adequately high SNRs, and record signals with equivalent variability. Whether surface electrodes are non-inferior to subcutaneous needle electrodes in detecting motor warnings is investigated in part II of the NERFACE study.
- 10 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1404
Open AccessComparing Motor-Evoked Potential Characteristics of NEedle versus suRFACE Recording Electrodes during Spinal Cord Monitoring—The NERFACE Study Part I
Muscle-recorded transcranial electrical stimulation motor-evoked potentials (mTc-MEPs) are used to assess the spinal cord integrity. They are commonly recorded with subcutaneous needle or surface electrodes, but the different characteristics of mTc-MEP signals recorded with the two types of electrodes have not been formally compared yet. In this study, mTc-MEPs were simultaneously recorded from the tibialis anterior (TA) muscles using surface and subcutaneous needle electrodes in 242 consecutive patients. Elicitability, motor thresholds, amplitude, area under the curve (AUC), signal-to-noise ratio (SNR), and the variability between mTc-MEP amplitudes were compared. Whereas amplitude and AUC were significantly higher in subcutaneous needle recordings (p < 0.01), motor thresholds and elicitability were similar for surface and subcutaneous needle recordings. Moreover, the SNRs were >2 in more than 99.5% of the surface and subcutaneous needle recordings, and the variability between consecutive amplitudes was not significantly different between the two recording electrode types (p = 0.34). Surface electrodes appear to be a good alternative to needle electrodes for spinal cord monitoring. They are non-invasive, can record signals at similar threshold intensities, have adequately high SNRs, and record signals with equivalent variability. Whether surface electrodes are non-inferior to subcutaneous needle electrodes in detecting motor warnings is investigated in part II of the NERFACE study.
- Open Access
- 26 October 2022
- Published by Elsevier in Clinical Parkinsonism & Related Disorders
- Vol. 7, 100170
Measuring saccades in patients with Niemann-Pick type C: A comparison between video-oculography and a novel eye tracking test based on continuous psychophysics
- 26 October 2022
- Published by Elsevier in Clinical Parkinsonism & Related Disorders
- Vol. 7, 100170
Open AccessMeasuring saccades in patients with Niemann-Pick type C: A comparison between video-oculography and a novel eye tracking test based on continuous psychophysics
- 1 January 2017
- Published by Elsevier in Clinical Neurophysiology
- Vol. 128 (1) , 253-259
Myoclonus subtypes in tertiary referral center. Cortical myoclonus and functional jerks are common
- 1 January 2017
- Published by Elsevier in Clinical Neurophysiology
- Vol. 128 (1) , 253-259
Myoclonus subtypes in tertiary referral center. Cortical myoclonus and functional jerks are common