Seshadri Raju
Research Subjects
Research Interests
Seshadri Raju has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Arjun Jayaraj
RANE Ctr Venous & Lymphat Dis, Jackson, MS USA
11 shared publicationsPeter Neglen
8 shared publicationsPeter Neglén
7 shared publicationsRiley Kuykendall
The RANE Center, Jackson, USA
7 shared publicationsDavid Thaggard
RANE Ctr Venous & Lymphat Dis, Jackson, MS USA
5 shared publicationsTaimur Saleem
The RANE Center for Venous & Lymphatic Diseases, Jackson, MS
5 shared publications
Latest Publications
- Open Access
- 3 March 2026
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 14 (4) , 102467
Venous flow phasicity is not caused by the thoracoabdominal pump, but results from luminal deformation of the inferior vena cava caused by respiratory diaphragmatic movement
- 3 March 2026
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 14 (4) , 102467
Open AccessVenous flow phasicity is not caused by the thoracoabdominal pump, but results from luminal deformation of the inferior vena cava caused by respiratory diaphragmatic movement
- Open Access
- 6 June 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 13 (5) , 102275
Limb volumetry using an iPad-based three-dimensional scanner for assessment of edema
- 6 June 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 13 (5) , 102275
Open AccessLimb volumetry using an iPad-based three-dimensional scanner for assessment of edema
- 16 May 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 69 (5) , e275
Evaluation of the diagnostic accuracy of contrast enhanced ultrasonography in chronic iliac venous obstruction
- 16 May 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 69 (5) , e275
Evaluation of the diagnostic accuracy of contrast enhanced ultrasonography in chronic iliac venous obstruction
- Open Access
- 20 February 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 13 (3) , 102001
Evaluation of the diagnostic accuracy of contrast enhanced ultrasonography in chronic iliac venous obstruction
- 20 February 2025
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 13 (3) , 102001
Open AccessEvaluation of the diagnostic accuracy of contrast enhanced ultrasonography in chronic iliac venous obstruction
- 13 January 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 69 (1) , e21
Evaluation of the diagnostic accuracy of contrast enhanced ultrasonography in chronic iliac venous obstruction
- 13 January 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 69 (1) , e21
Evaluation of the diagnostic accuracy of contrast enhanced ultrasonography in chronic iliac venous obstruction
- Open Access
- 28 February 2024
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 12 (4) , 101861
Noninvasive measurement of ambulatory venous pressure via column interruption duration in chronic venous disease
- 28 February 2024
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 12 (4) , 101861
Open AccessNoninvasive measurement of ambulatory venous pressure via column interruption duration in chronic venous disease
- 9 November 2023
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 66 (5) , e64-e65
Inguinal intranodal lymphangiography reveals a high incidence of suprainguinal lymphatic disease in patients with leg edema undergoing stenting for symptomatic chronic iliofemoral venous obstruction
- 9 November 2023
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 66 (5) , e64-e65
Inguinal intranodal lymphangiography reveals a high incidence of suprainguinal lymphatic disease in patients with leg edema undergoing stenting for symptomatic chronic iliofemoral venous obstruction
- 11 July 2023
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 11 (6) , 1192-1201.e2
Inguinal intranodal lymphangiography reveals a high incidence of suprainguinal lymphatic disease in patients with leg edema undergoing stenting for symptomatic chronic iliofemoral venous obstruction
- 11 July 2023
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 11 (6) , 1192-1201.e2
Inguinal intranodal lymphangiography reveals a high incidence of suprainguinal lymphatic disease in patients with leg edema undergoing stenting for symptomatic chronic iliofemoral venous obstruction
- Open Access
- 23 June 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Conduit design with expanding diameter for enhanced flow
Conduits are commonly used for treating lesions in arteries and veins. The conventional stents are cylindrical in shape, which increases flow resistance with length. This study presents a design of stents and conduits where the conduit caliber expands gradually to reduce resistance while avoiding flow separation. Inflow was provided from a header tank at two different pressures (i.e., 10 and 25 mm Hg pressure) into a cylindrical or expanding conduit. The initial conduit calibers were 2-, 3-, 4-, and 5-mm and 160-, 310-, and 620-mm lengths in each case. The flow rates of expanding caliber conduits (at a rate of r4–6/cm where r is the initial conduit radius) were compared to traditional cylindrical conduits of constant radius. The expanded caliber yields a significantly increased flow of 16–55% for R4/L expansion, 9–44% for R5/L expansion, and 1–28% for R6/L expansion. Simulated flow models using computational fluid dynamics (CFD) were used to validate and expand the experimental findings. Flow separation was detected for certain simulations by flow pathlines and wall shear stress (WSS) calculations. The results showed that a caliber expansion rate of r6/cm is the optimal rate of expansion for most potential applications with minimum flow separation, lower resistance, and increased flow.
- 23 June 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Open AccessConduit design with expanding diameter for enhanced flow
Conduits are commonly used for treating lesions in arteries and veins. The conventional stents are cylindrical in shape, which increases flow resistance with length. This study presents a design of stents and conduits where the conduit caliber expands gradually to reduce resistance while avoiding flow separation. Inflow was provided from a header tank at two different pressures (i.e., 10 and 25 mm Hg pressure) into a cylindrical or expanding conduit. The initial conduit calibers were 2-, 3-, 4-, and 5-mm and 160-, 310-, and 620-mm lengths in each case. The flow rates of expanding caliber conduits (at a rate of r4–6/cm where r is the initial conduit radius) were compared to traditional cylindrical conduits of constant radius. The expanded caliber yields a significantly increased flow of 16–55% for R4/L expansion, 9–44% for R5/L expansion, and 1–28% for R6/L expansion. Simulated flow models using computational fluid dynamics (CFD) were used to validate and expand the experimental findings. Flow separation was detected for certain simulations by flow pathlines and wall shear stress (WSS) calculations. The results showed that a caliber expansion rate of r6/cm is the optimal rate of expansion for most potential applications with minimum flow separation, lower resistance, and increased flow.
- 3 March 2023
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 65 (3) , e34
Plethysmographic features of calf pump failure in chronic venous obstruction and reflux
- 3 March 2023
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 65 (3) , e34
Plethysmographic features of calf pump failure in chronic venous obstruction and reflux