Saghi Sadoughi
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Saghi Sadoughi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Galateia J. Kazakia
Department of Radiology and Biomedical Imaging, University of California , San Francisco, CA 94158
2 shared publications Aditya Subramanian
Bone Quality Research Lab, Department of Radiology and Biomedical Imaging University of California San Francisco CA USA
1 shared publication- Aditya Subramanian
Bone Quality Research Lab , Department of Radiology and Biomedical Imaging San Francisco, 185 Berry St., Suite 350, San Francisco, CA 94107, United States
1 shared publication Andrew J Burghardt
Bone Quality Research Lab, Department of Radiology and Biomedical Imaging University of California San Francisco CA USA
1 shared publication- Andrew J. Burghardt
Department of Radiology and Biomedical Imaging, University of California San Francisco , San Francisco, CA 94158
1 shared publication - Anne L. Schafer
Department of Epidemiology and Biostatistics University of California San Francisco CA USA
1 shared publication
Latest Publications
- Open Access
- 27 August 2024
- Published by Oxford University Press (OUP) in JBMR Plus
- Vol. 8 (10) , ziae116
HR-pQCT cross-calibration using standard vs. Laplace-Hamming binarization approach
High-resolution peripheral quantitative computed tomography (HR-pQCT) has emerged as a powerful imaging technique for characterizing bone microarchitecture in the human peripheral skeleton. The second-generation HR-pQCT scanner provides improved spatial resolution and a shorter scan time. However, the transition from the first-generation (XCTI) to second-generation HR-pQCT scanners (XCTII) poses challenges for longitudinal studies, multi-center trials, and comparison to historical data. Cross-calibration, an established approach for determining relationships between measurements obtained from different devices, can bridge this gap and enable the utilization and comparison of legacy data. The goal of this study was to establish cross-calibration equations to estimate XCTII measurements from XCTI data, using both the standard and Laplace-Hamming (LH) binarization approaches. Thirty-six volunteers (26–85 yr) were recruited and their radii and tibiae were scanned on both XCTI and XCTII scanners. XCTI images were analyzed using the manufacturer’s standard protocol. XCTII images were analyzed twice: using the manufacturer’s standard protocol and the LH segmentation approach previously developed and validated by our team. Linear regression analysis was used to establish cross-calibration equations. Results demonstrated strong correlations between XCTI and XCTII density and geometry outcomes. For most microstructural outcomes, although there were considerable differences in absolute values, correlations between measurements obtained from different scanners were strong, allowing for accurate cross-calibration estimations. For some microstructural outcomes with a higher sensitivity to spatial resolution (eg, trabecular thickness, cortical pore diameter), XCTII standard protocol resulted in poor correlations between the scanners, while our LH approach improved these correlations and decreased the difference in absolute values and the proportional bias for other measurements. For these reasons and due to the improved accuracy of our LH approach compared with the standard approach, as established in our previous study, we propose that investigators should use the LH approach for analyzing XCTII scans, particularly when comparing to XCTI data.
- 27 August 2024
- Published by Oxford University Press (OUP) in JBMR Plus
- Vol. 8 (10) , ziae116
Open AccessHR-pQCT cross-calibration using standard vs. Laplace-Hamming binarization approach
High-resolution peripheral quantitative computed tomography (HR-pQCT) has emerged as a powerful imaging technique for characterizing bone microarchitecture in the human peripheral skeleton. The second-generation HR-pQCT scanner provides improved spatial resolution and a shorter scan time. However, the transition from the first-generation (XCTI) to second-generation HR-pQCT scanners (XCTII) poses challenges for longitudinal studies, multi-center trials, and comparison to historical data. Cross-calibration, an established approach for determining relationships between measurements obtained from different devices, can bridge this gap and enable the utilization and comparison of legacy data. The goal of this study was to establish cross-calibration equations to estimate XCTII measurements from XCTI data, using both the standard and Laplace-Hamming (LH) binarization approaches. Thirty-six volunteers (26–85 yr) were recruited and their radii and tibiae were scanned on both XCTI and XCTII scanners. XCTI images were analyzed using the manufacturer’s standard protocol. XCTII images were analyzed twice: using the manufacturer’s standard protocol and the LH segmentation approach previously developed and validated by our team. Linear regression analysis was used to establish cross-calibration equations. Results demonstrated strong correlations between XCTI and XCTII density and geometry outcomes. For most microstructural outcomes, although there were considerable differences in absolute values, correlations between measurements obtained from different scanners were strong, allowing for accurate cross-calibration estimations. For some microstructural outcomes with a higher sensitivity to spatial resolution (eg, trabecular thickness, cortical pore diameter), XCTII standard protocol resulted in poor correlations between the scanners, while our LH approach improved these correlations and decreased the difference in absolute values and the proportional bias for other measurements. For these reasons and due to the improved accuracy of our LH approach compared with the standard approach, as established in our previous study, we propose that investigators should use the LH approach for analyzing XCTII scans, particularly when comparing to XCTI data.
- Open Access
- 13 May 2023
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 38 (7) , 1006-1014
A Laplace–Hamming Binarization Approach for Second‐Generation HR‐pQCT Rescues Fine Feature Segmentation
Although second‐generation high‐resolution peripheral quantitative computed tomography (XCTII) provides the highest‐resolution in vivo bone microstructure assessment, the manufacturer's standard image processing protocol omits fine features in both trabecular and cortical compartments. To optimize fine structure segmentation, we implemented a binarization approach based on a Laplace–Hamming (LH) segmentation and documented the reproducibility and accuracy of XCTII structure segmentation using both the standard Gaussian‐based binarization and the proposed LH segmentation approach. To evaluate reproducibility, 20 volunteers (9 women, 11 men; aged 23–75 years) were recruited, and three repeat scans of the radii and tibias were acquired using the manufacturer's standard in vivo protocol. To evaluate accuracy, cadaveric structure phantoms (14 radii, 6 tibias) were scanned on XCTII using the same standard in vivo protocol and on μCT at 24.5 μm resolution. XCTII images were analyzed twice—first, with the manufacturer's standard patient evaluation protocol and, second, with the proposed LH segmentation approach. The LH approach rescued fine features evident in the grayscale images but omitted or overrepresented (thickened) by the standard approach. The LH approach significantly reduced error in trabecular volume fraction (BV/TV) and thickness (Tb.Th) compared with the standard approach; however, higher error was introduced for trabecular separation (Tb.Sp). The LH approach improved the correlation between XCTII and μCT for cortical porosity (Ct.Po) and significantly reduced error in cortical pore diameter (Ct.Po.Dm) compared with the standard approach. The LH approach resulted in improved precision compared with the standard approach for BV/TV, Tb.Th, Ct.Po, and Ct.Po.Dm at the radius and for Ct.Po at the tibia. Our results suggest that the proposed LH approach produces substantially improved binary masks, reduces proportional bias, and provides greater accuracy and reproducibility in important outcome metrics, all due to more accurate segmentation of the fine features in both trabecular and cortical compartments. © 2023 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).
- 13 May 2023
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 38 (7) , 1006-1014
Open AccessA Laplace–Hamming Binarization Approach for Second‐Generation HR‐pQCT Rescues Fine Feature Segmentation
Although second‐generation high‐resolution peripheral quantitative computed tomography (XCTII) provides the highest‐resolution in vivo bone microstructure assessment, the manufacturer's standard image processing protocol omits fine features in both trabecular and cortical compartments. To optimize fine structure segmentation, we implemented a binarization approach based on a Laplace–Hamming (LH) segmentation and documented the reproducibility and accuracy of XCTII structure segmentation using both the standard Gaussian‐based binarization and the proposed LH segmentation approach. To evaluate reproducibility, 20 volunteers (9 women, 11 men; aged 23–75 years) were recruited, and three repeat scans of the radii and tibias were acquired using the manufacturer's standard in vivo protocol. To evaluate accuracy, cadaveric structure phantoms (14 radii, 6 tibias) were scanned on XCTII using the same standard in vivo protocol and on μCT at 24.5 μm resolution. XCTII images were analyzed twice—first, with the manufacturer's standard patient evaluation protocol and, second, with the proposed LH segmentation approach. The LH approach rescued fine features evident in the grayscale images but omitted or overrepresented (thickened) by the standard approach. The LH approach significantly reduced error in trabecular volume fraction (BV/TV) and thickness (Tb.Th) compared with the standard approach; however, higher error was introduced for trabecular separation (Tb.Sp). The LH approach improved the correlation between XCTII and μCT for cortical porosity (Ct.Po) and significantly reduced error in cortical pore diameter (Ct.Po.Dm) compared with the standard approach. The LH approach resulted in improved precision compared with the standard approach for BV/TV, Tb.Th, Ct.Po, and Ct.Po.Dm at the radius and for Ct.Po at the tibia. Our results suggest that the proposed LH approach produces substantially improved binary masks, reduces proportional bias, and provides greater accuracy and reproducibility in important outcome metrics, all due to more accurate segmentation of the fine features in both trabecular and cortical compartments. © 2023 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).
- Open Access
- 8 February 2022
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 37 (4) , 753-763
Cortical Bone Loss Following Gastric Bypass Surgery Is Not Primarily Endocortical
Roux-en Y gastric bypass (RYGB) surgery is an effective treatment for obesity; however, it may negatively impact skeletal health by increasing fracture risk. This increase may be the result not only of decreased bone mineral density, but also of changes in bone microstructure, for example increased cortical porosity. Increased tibial and radial cortical porosity of patients undergoing RYGB surgery has been observed as early as six months postoperatively; however, local microstructural changes and associated biological mechanisms driving this increase remain unclear. To provide insight, we studied the spatial distribution of cortical porosity in 42 women and men (age: 46±12 years) following RYGB surgery. Distal tibiae and radii were evaluated with HR-pQCT preoperatively and at 12 months postoperatively. Laminar analysis was used to determine cortical pore number and size within the endosteal, midcortical, and periosteal layers of the cortex. Paired t-tests were used to compare baseline versus follow-up porosity parameters in each layer. Mixed models were used to compare longitudinal changes in laminar analysis outcomes between layers. We found that the midcortical (0.927±0.607 mm-2 to 1.069±0.654 mm-2, p=0.004; 0.439±0.293 mm-2 to 0.509±0.343 mm-2, p=0.03) and periosteal (0.642±0.412 mm-2 to 0.843±0.452 mm-2, p-2 to 0.230±0.160 mm-2, p=0.003) layers underwent the greatest increases in porosity over the 12-month period at the distal tibia and radius, respectively. The endosteal layer, which had the greatest porosity at baseline, did not undergo significant porosity increase over the same period (1.234±0.402 mm-2 to 1.259±0.413 mm-2, p=0.49; 0.584±0.290 mm-2 to 0.620±0.299 mm-2, p=0.35) at the distal tibia and radius, respectively. An alternative baseline-mapping approach for endosteal boundary definition confirmed that cortical bone loss was not primarily endosteal. These findings indicate that increases in cortical porosity happen in regions distant from the endosteal surface, suggesting that the underlying mechanism driving the increase in cortical porosity is not merely endosteal trabecularization.
- 8 February 2022
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 37 (4) , 753-763
Open AccessCortical Bone Loss Following Gastric Bypass Surgery Is Not Primarily Endocortical
Roux-en Y gastric bypass (RYGB) surgery is an effective treatment for obesity; however, it may negatively impact skeletal health by increasing fracture risk. This increase may be the result not only of decreased bone mineral density, but also of changes in bone microstructure, for example increased cortical porosity. Increased tibial and radial cortical porosity of patients undergoing RYGB surgery has been observed as early as six months postoperatively; however, local microstructural changes and associated biological mechanisms driving this increase remain unclear. To provide insight, we studied the spatial distribution of cortical porosity in 42 women and men (age: 46±12 years) following RYGB surgery. Distal tibiae and radii were evaluated with HR-pQCT preoperatively and at 12 months postoperatively. Laminar analysis was used to determine cortical pore number and size within the endosteal, midcortical, and periosteal layers of the cortex. Paired t-tests were used to compare baseline versus follow-up porosity parameters in each layer. Mixed models were used to compare longitudinal changes in laminar analysis outcomes between layers. We found that the midcortical (0.927±0.607 mm-2 to 1.069±0.654 mm-2, p=0.004; 0.439±0.293 mm-2 to 0.509±0.343 mm-2, p=0.03) and periosteal (0.642±0.412 mm-2 to 0.843±0.452 mm-2, p-2 to 0.230±0.160 mm-2, p=0.003) layers underwent the greatest increases in porosity over the 12-month period at the distal tibia and radius, respectively. The endosteal layer, which had the greatest porosity at baseline, did not undergo significant porosity increase over the same period (1.234±0.402 mm-2 to 1.259±0.413 mm-2, p=0.49; 0.584±0.290 mm-2 to 0.620±0.299 mm-2, p=0.35) at the distal tibia and radius, respectively. An alternative baseline-mapping approach for endosteal boundary definition confirmed that cortical bone loss was not primarily endosteal. These findings indicate that increases in cortical porosity happen in regions distant from the endosteal surface, suggesting that the underlying mechanism driving the increase in cortical porosity is not merely endosteal trabecularization.