Sofia Somajo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sofia Somajo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Oskar Ekelund
Clinical Microbiology, Växjö Hospital, Växjö, Sweden
3 shared publications - Annika Petersson
Clinical Chemistry and Transfusion Medicine, Växjö Central Hospital, Växjö, Sweden
2 shared publications - Johanna Pattison-Granberg
Department of Clinical Chemistry and Transfusion Medicine, Växjö Central Hospital, Växjö, Sweden
2 shared publications Karl Olsson
Department of Clinical Microbiology, Blekinge County Hospital, Karlskrona, Sweden
2 shared publications- Kim Ekblom
Department of Medical Biosciences, Clinical Chemistry, Umeå University, Umeå, Sweden (Drs Mickelsson, Stefansson, Ekblom, Hultdin); Department of Research and Development, Region Kronoberg, Växjö, Sweden (Dr Ekblom)
2 shared publications Frida Nilsson
Department of Clinical Microbiology, Region Kronoberg , Växjö/Karlskrona , Sweden
1 shared publication
Latest Publications
- Open Access
- 9 February 2024
- Published by Oxford University Press (OUP) in Journal of Antimicrobial Chemotherapy
- Vol. 79 (4) , 815-819
Detection of antimicrobial resistance in Neisseria gonorrhoeae isolates using flow cytometry—proof of concept for seven clinically relevant antimicrobials
Antimicrobial resistance in Neisseria gonorrhoeae compromises gonorrhoea treatment and rapid antimicrobial susceptibility testing (AST) would be valuable. We have developed a rapid and accurate flow cytometry method (FCM) for AST of gonococci. The 2016 WHO gonococcal reference strains, and WHO Q, R and S (n = 17) were tested against seven clinically relevant antibiotics (ceftriaxone, cefixime, azithromycin, spectinomycin, ciprofloxacin, tetracycline and gentamicin). After 4.5 h incubation of inoculated broth, the fluorescent dye Syto™ 9 was added, followed by FCM analysis. After gating, the relative remaining population of gonococci, compared with unexposed growth control samples, was plotted against antimicrobial concentration, followed by non-linear curve regression analysis. Furthermore, the response at one single concentration/tested antibiotic was evaluated with the intention to use as a screening test for detection of resistant gonococci. A dose-dependent response was seen in susceptible isolates for all tested antimicrobials. There was a clear separation between susceptible/WT and resistant/non-WT isolates for ceftriaxone, cefixime, spectinomycin, ciprofloxacin and tetracycline. In contrast, for azithromycin, only high-level-resistant isolates were distinguished, while resistant isolates with MICs of 4 mg/L were indistinguishable from WT (MIC ≤ 1 mg/L) isolates. For gentamicin, all tested 17 isolates were WT and FCM analysis resulted in uniform dose–response curves. Using a single antibiotic concentration and a 50% remaining cell population cut-off, the overall sensitivity and specificity for resistance detection were 93% and 99%, respectively. By providing results in <5 h for gonococcal isolates, FCM-based AST can become a rapid screening method for antimicrobial resistance or antimicrobial susceptibility in gonococci.
- 9 February 2024
- Published by Oxford University Press (OUP) in Journal of Antimicrobial Chemotherapy
- Vol. 79 (4) , 815-819
Open AccessDetection of antimicrobial resistance in Neisseria gonorrhoeae isolates using flow cytometry—proof of concept for seven clinically relevant antimicrobials
Antimicrobial resistance in Neisseria gonorrhoeae compromises gonorrhoea treatment and rapid antimicrobial susceptibility testing (AST) would be valuable. We have developed a rapid and accurate flow cytometry method (FCM) for AST of gonococci. The 2016 WHO gonococcal reference strains, and WHO Q, R and S (n = 17) were tested against seven clinically relevant antibiotics (ceftriaxone, cefixime, azithromycin, spectinomycin, ciprofloxacin, tetracycline and gentamicin). After 4.5 h incubation of inoculated broth, the fluorescent dye Syto™ 9 was added, followed by FCM analysis. After gating, the relative remaining population of gonococci, compared with unexposed growth control samples, was plotted against antimicrobial concentration, followed by non-linear curve regression analysis. Furthermore, the response at one single concentration/tested antibiotic was evaluated with the intention to use as a screening test for detection of resistant gonococci. A dose-dependent response was seen in susceptible isolates for all tested antimicrobials. There was a clear separation between susceptible/WT and resistant/non-WT isolates for ceftriaxone, cefixime, spectinomycin, ciprofloxacin and tetracycline. In contrast, for azithromycin, only high-level-resistant isolates were distinguished, while resistant isolates with MICs of 4 mg/L were indistinguishable from WT (MIC ≤ 1 mg/L) isolates. For gentamicin, all tested 17 isolates were WT and FCM analysis resulted in uniform dose–response curves. Using a single antibiotic concentration and a 50% remaining cell population cut-off, the overall sensitivity and specificity for resistance detection were 93% and 99%, respectively. By providing results in <5 h for gonococcal isolates, FCM-based AST can become a rapid screening method for antimicrobial resistance or antimicrobial susceptibility in gonococci.
- Open Access
- 3 September 2021
- Published by Oxford University Press (OUP) in Journal of Antimicrobial Chemotherapy
- Vol. 76 (12) , 3183-3191
Rapid high-resolution detection of colistin resistance in Gram-negative bacteria using flow cytometry: a comparison with broth microdilution, a commercial screening test and WGS
Background: Even though both EUCAST and CLSI consider broth microdilution (BMD) as the reference method for antimicrobial susceptibility testing (AST) of colistin, the method exhibits potential flaws related to properties of the colistin molecule. Objectives: To develop a flow cytometry method (FCM) for colistin AST and to validate it against BMD, a commercial screening test and WGS. Methods: Colistin-mediated loss of membrane integrity in Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa and Acinetobacter spp. was detected with the fluorescent probe YoPro-1 by FCM. An international collection of 65 resistant and 109 susceptible isolates were analysed and the colistin concentration required to reach the EC50 was compared with the BMD MIC and the presence of genotypic resistance markers. Results: The overall FCM sensitivity and specificity for colistin resistance was 89% and 94%, with E. coli > K. pneumoniae > P. aeruginosa, whereas the performance for Acinetobacter spp. was poor. All tested E. coli were correctly categorized. Three K. pneumoniae isolates with genotypic findings consistent with colistin resistance were detected by FCM but not BMD. Compared with BMD, FCM delivered AST results with a 75% reduction of time. Conclusions: Here, we present a rapid FCM-based AST assay for qualitative and quantitative testing of colistin resistance in E. coli and K. pneumoniae. The assay revealed probable chromosomal colistin resistance in K. pneumoniae that was not detected by BMD. If confirmed, these results question the reliability of BMD for colistin testing.
- 3 September 2021
- Published by Oxford University Press (OUP) in Journal of Antimicrobial Chemotherapy
- Vol. 76 (12) , 3183-3191
Open AccessRapid high-resolution detection of colistin resistance in Gram-negative bacteria using flow cytometry: a comparison with broth microdilution, a commercial screening test and WGS
Background: Even though both EUCAST and CLSI consider broth microdilution (BMD) as the reference method for antimicrobial susceptibility testing (AST) of colistin, the method exhibits potential flaws related to properties of the colistin molecule. Objectives: To develop a flow cytometry method (FCM) for colistin AST and to validate it against BMD, a commercial screening test and WGS. Methods: Colistin-mediated loss of membrane integrity in Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa and Acinetobacter spp. was detected with the fluorescent probe YoPro-1 by FCM. An international collection of 65 resistant and 109 susceptible isolates were analysed and the colistin concentration required to reach the EC50 was compared with the BMD MIC and the presence of genotypic resistance markers. Results: The overall FCM sensitivity and specificity for colistin resistance was 89% and 94%, with E. coli > K. pneumoniae > P. aeruginosa, whereas the performance for Acinetobacter spp. was poor. All tested E. coli were correctly categorized. Three K. pneumoniae isolates with genotypic findings consistent with colistin resistance were detected by FCM but not BMD. Compared with BMD, FCM delivered AST results with a 75% reduction of time. Conclusions: Here, we present a rapid FCM-based AST assay for qualitative and quantitative testing of colistin resistance in E. coli and K. pneumoniae. The assay revealed probable chromosomal colistin resistance in K. pneumoniae that was not detected by BMD. If confirmed, these results question the reliability of BMD for colistin testing.
- 29 May 2021
- Published by Taylor & Francis in Infectious Diseases
- Vol. 53 (10) , 805-810
High-throughput immunoassays for SARS-CoV-2 – considerable differences in performance when comparing three methods
The recently launched high-throughput assays for detecting antibodies against SARS-CoV-2 has contributed to the managing strategies for the COVID-19 pandemic. This study aimed to investigate the pe...
- 29 May 2021
- Published by Taylor & Francis in Infectious Diseases
- Vol. 53 (10) , 805-810
High-throughput immunoassays for SARS-CoV-2 – considerable differences in performance when comparing three methods
The recently launched high-throughput assays for detecting antibodies against SARS-CoV-2 has contributed to the managing strategies for the COVID-19 pandemic. This study aimed to investigate the pe...
- Open Access
High-throughput immunoassays for SARS-CoV-2 – considerable differences in performance when comparing three methods
Background: The recently launched high-throughput assays for the detection of antibodies against SARS-CoV-2 may change the managing strategies for the COVID-19 pandemic. This study aimed at investigating the performance of three high-throughput assays and one rapid lateral flow test relative to the recommended criteria defined by regulatory authorities. Methods: A total of 133 samples, including 100 pre-pandemic samples, 20 samples from SARS-CoV-2 RT-PCR positive individuals, and 13 potentially cross-reactive samples were analysed with SARS-CoV-2 IgG (Abbott), Elecsys Anti-SARS-CoV-2 (Roche), LIAISON SARS-CoV-2 S1/S2 IgG (DiaSorin) and 2019-nCOV IgG/IgM Rapid Test (Dynamiker Biotechnology Co). Results: All assays performed with a high level of specificity; however, only Abbott reached 100% (95% CI 96.3-100). The pre-pandemic samples analysed with Roche, DiaSorin and Dynamiker Biotechnology resulted in two to three false-positive results per method (specificity 96.9-98.0%). Sensitivity differed more between the assays, Roche exhibiting the highest sensitivity (100%, CI 83.9-100). The corresponding figures for Abbott, DiaSorin and Dynamiker Biotechnology were 85.0%, 77.8% and 75.0%, respectively. Conclusions: The results of the evaluated SARS-CoV-2 assays vary considerably as well as their ability to fulfil the performance criteria proposed by regulatory authorities. Introduction into clinical use in low-prevalent settings, should therefore, be made with caution.
Open AccessHigh-throughput immunoassays for SARS-CoV-2 – considerable differences in performance when comparing three methods
Background: The recently launched high-throughput assays for the detection of antibodies against SARS-CoV-2 may change the managing strategies for the COVID-19 pandemic. This study aimed at investigating the performance of three high-throughput assays and one rapid lateral flow test relative to the recommended criteria defined by regulatory authorities. Methods: A total of 133 samples, including 100 pre-pandemic samples, 20 samples from SARS-CoV-2 RT-PCR positive individuals, and 13 potentially cross-reactive samples were analysed with SARS-CoV-2 IgG (Abbott), Elecsys Anti-SARS-CoV-2 (Roche), LIAISON SARS-CoV-2 S1/S2 IgG (DiaSorin) and 2019-nCOV IgG/IgM Rapid Test (Dynamiker Biotechnology Co). Results: All assays performed with a high level of specificity; however, only Abbott reached 100% (95% CI 96.3-100). The pre-pandemic samples analysed with Roche, DiaSorin and Dynamiker Biotechnology resulted in two to three false-positive results per method (specificity 96.9-98.0%). Sensitivity differed more between the assays, Roche exhibiting the highest sensitivity (100%, CI 83.9-100). The corresponding figures for Abbott, DiaSorin and Dynamiker Biotechnology were 85.0%, 77.8% and 75.0%, respectively. Conclusions: The results of the evaluated SARS-CoV-2 assays vary considerably as well as their ability to fulfil the performance criteria proposed by regulatory authorities. Introduction into clinical use in low-prevalent settings, should therefore, be made with caution.