Johanna Pattison-Granberg
Research Subjects
Research Interests
Johanna Pattison-Granberg has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Annika Petersson
Clinical Chemistry and Transfusion Medicine, Växjö Central Hospital, Växjö, Sweden
2 shared publications Karl Olsson
Department of Clinical Microbiology, Blekinge County Hospital, Karlskrona, Sweden
2 shared publications- Kim Ekblom
Department of Medical Biosciences, Clinical Chemistry, Umeå University, Umeå, Sweden (Drs Mickelsson, Stefansson, Ekblom, Hultdin); Department of Research and Development, Region Kronoberg, Växjö, Sweden (Dr Ekblom)
2 shared publications - Oskar Ekelund
Clinical Microbiology, Växjö Hospital, Växjö, Sweden
2 shared publications - Sofia Somajo
Department of Clinical Microbiology, Blekinge County Hospital, Karlskrona, Sweden
2 shared publications
Latest Publications
- 29 May 2021
- Published by Taylor & Francis in Infectious Diseases
- Vol. 53 (10) , 805-810
High-throughput immunoassays for SARS-CoV-2 – considerable differences in performance when comparing three methods
The recently launched high-throughput assays for detecting antibodies against SARS-CoV-2 has contributed to the managing strategies for the COVID-19 pandemic. This study aimed to investigate the pe...
- 29 May 2021
- Published by Taylor & Francis in Infectious Diseases
- Vol. 53 (10) , 805-810
High-throughput immunoassays for SARS-CoV-2 – considerable differences in performance when comparing three methods
The recently launched high-throughput assays for detecting antibodies against SARS-CoV-2 has contributed to the managing strategies for the COVID-19 pandemic. This study aimed to investigate the pe...
- Open Access
High-throughput immunoassays for SARS-CoV-2 – considerable differences in performance when comparing three methods
Background: The recently launched high-throughput assays for the detection of antibodies against SARS-CoV-2 may change the managing strategies for the COVID-19 pandemic. This study aimed at investigating the performance of three high-throughput assays and one rapid lateral flow test relative to the recommended criteria defined by regulatory authorities. Methods: A total of 133 samples, including 100 pre-pandemic samples, 20 samples from SARS-CoV-2 RT-PCR positive individuals, and 13 potentially cross-reactive samples were analysed with SARS-CoV-2 IgG (Abbott), Elecsys Anti-SARS-CoV-2 (Roche), LIAISON SARS-CoV-2 S1/S2 IgG (DiaSorin) and 2019-nCOV IgG/IgM Rapid Test (Dynamiker Biotechnology Co). Results: All assays performed with a high level of specificity; however, only Abbott reached 100% (95% CI 96.3-100). The pre-pandemic samples analysed with Roche, DiaSorin and Dynamiker Biotechnology resulted in two to three false-positive results per method (specificity 96.9-98.0%). Sensitivity differed more between the assays, Roche exhibiting the highest sensitivity (100%, CI 83.9-100). The corresponding figures for Abbott, DiaSorin and Dynamiker Biotechnology were 85.0%, 77.8% and 75.0%, respectively. Conclusions: The results of the evaluated SARS-CoV-2 assays vary considerably as well as their ability to fulfil the performance criteria proposed by regulatory authorities. Introduction into clinical use in low-prevalent settings, should therefore, be made with caution.
Open AccessHigh-throughput immunoassays for SARS-CoV-2 – considerable differences in performance when comparing three methods
Background: The recently launched high-throughput assays for the detection of antibodies against SARS-CoV-2 may change the managing strategies for the COVID-19 pandemic. This study aimed at investigating the performance of three high-throughput assays and one rapid lateral flow test relative to the recommended criteria defined by regulatory authorities. Methods: A total of 133 samples, including 100 pre-pandemic samples, 20 samples from SARS-CoV-2 RT-PCR positive individuals, and 13 potentially cross-reactive samples were analysed with SARS-CoV-2 IgG (Abbott), Elecsys Anti-SARS-CoV-2 (Roche), LIAISON SARS-CoV-2 S1/S2 IgG (DiaSorin) and 2019-nCOV IgG/IgM Rapid Test (Dynamiker Biotechnology Co). Results: All assays performed with a high level of specificity; however, only Abbott reached 100% (95% CI 96.3-100). The pre-pandemic samples analysed with Roche, DiaSorin and Dynamiker Biotechnology resulted in two to three false-positive results per method (specificity 96.9-98.0%). Sensitivity differed more between the assays, Roche exhibiting the highest sensitivity (100%, CI 83.9-100). The corresponding figures for Abbott, DiaSorin and Dynamiker Biotechnology were 85.0%, 77.8% and 75.0%, respectively. Conclusions: The results of the evaluated SARS-CoV-2 assays vary considerably as well as their ability to fulfil the performance criteria proposed by regulatory authorities. Introduction into clinical use in low-prevalent settings, should therefore, be made with caution.