JMJoan Carles Monllau

Joan Carles Monllau

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joan Carles Monllau has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Bone Cut Accuracy in Total Knee Arthroplasty: Do Conventional Cutting Guides Stay True to the Planned Coronal Orientation of the Components?

    by Joan Leal-Blanquet, Pedro Hinarejos, Elisenda Gimenez-Valero, Raul Torres-Claramunt, Juan Sánchez-Soler, Juan Erquicia, Sergi Gil-González, Angela Zumel-Marne, Juan Carlos Monllau

    Background: Total knee arthroplasty (TKA) has become the gold standard for the definitive treatment of knee osteoarthritis. One crucial aspect in the implantation of a TKA is the precise orientation of the femoral and tibial components. The main purpose of the present study is to assess, in patients undergoing total knee replacement, whether the difference between the planned angulation in the distal femoral cut and the angulation obtained in the postoperative radiological control is low enough to consider the conventional bone-cutting guides reliable. Methods: A retrospective study was designed with a consecutive series of patients who had undergone primary total knee arthroplasty using conventional instrumentation over one year. The authors analysed the main variable (bone cuts) while considering different variables (age, gender, surgeon, prosthesis, laterality, constraint, body mass index and alignment) to identify different patient patterns that justify the results in the main variable. Descriptive variables were analysed using the Mann–Whitney U and Kruskal–Wallis tests. Additionally, the correlation between continuous variables was explored in accordance with the Spearman correlation. Results: A total of 340 patients with a mean age of 75 ± 9.16 years were finally included in the present study. The mean absolute error of the main variable for the femoral coronal bone cut was 1.89° (SD 1.53). For the tibial coronal bone cut, it was 1.31° (SD 2.54). These values correspond to what remains after subtracting the radiological angulation obtained in the postoperative period from the planned intraoperative angulation of the distal femoral cut. No associations were observed between the main variable (the angulation of the proximal tibial cut and distal femoral cut) and the rest of variables for either the femur or tibia. Conclusion: A discrepancy between the planned angulation and the final radiological measure on the coronal plane of the femur and tibia using conventional cutting guides has been demonstrated. The degree of deviation is low enough that it probably does not affect clinical outcomes. Therefore, the use of conventional cutting guides will continue to be an appropriate tool to perform bone cuts in knee replacement surgery.


  • Open Access

    Proximal Tibiofibular Dislocation in a Closing-Wedge High Tibial Osteotomy Causes Lateral Radiological Gapping of the Knee: A Prospective Randomized Study

    by Raúl Torres-Claramunt, Juan Francisco Sánchez-Soler, Pedro Hinarejos, Aleix Sala-Pujals, Joan Leal-Blanquet, Joan Carles Monllau

    Background: To determine whether a proximal tibiofibular joint dislocation (TFJD) increases lateral compartment gapping more than a fibular head osteotomy (FHO) during a closing-wedge high tibial osteotomy (CWHTO). The second objective was to determine whether lateral compartment gapping affects clinical outcomes. Methods: A prospective randomized clinical study was carried out that included 18 patients in Group 1 (FHO) and 18 in Group 2 (TFJD). Varus-stress radiographs of all the patients with both knees at full extension and at 30° of flexion were studied pre-operatively and 12 months post-operatively. Lateral compartment gapping was measured in millimeters. The Knee Society Score (KSS) was used to assess clinical stability. Results: The difference between the pre- and post-operative measurements relative to gapping in the lateral knee compartment at 0° of knee flexion was 1.3 mm (SD 1.8) in Group 1 and 4.5 mm (SD 2.4) in Group 2 (p = 0.006). At 30° of knee flexion, this difference was 1.9 mm (SD 1.2) in Group 1 and 5.2 mm (SD 3.1) in Group 2 (p = 0.01). No differences were observed in the pre- and post-operative period relative to gapping in healthy knees. Pre-operatively, both groups presented similar KSS knee values: Group 1 with 54.7 (SD 11.7), Group 2 with 54.8 (SD 11.1) (n.s.). Post-operatively, these values were also similar: Group 1 with 93.2 (SD 7.4), Group 2 with 93.5 (SD 5.5) (n.s.). Conclusions: In patients who have undergone a CWHTO, TFJ dislocation increases knee lateral compartment gapping when compared to an FHO at 0° and 30° of knee flexion. However, this fact seems to have no repercussion on the functional status of the knees as measured with the KSS at the one-year follow-up.