Aaron Jake Merrell
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Aaron Jake Merrell has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Anton E. Bowden
Department of Mechanical Engineering, Brigham Young University, Provo, Utah
2 shared publications - David T. Fullwood
Mechanical Engineering, Brigham Young University, Provo, UT 84602, USA
2 shared publications - Matthew K. Seeley
Department of Exercise Sciences, Brigham Young University, Provo, USA
2 shared publications Alyssa Evans-Pickett
Department of Exercise Sciences, Brigham Young University , Provo, UT, USA
1 shared publication- Brian Anthony Mazzeo
Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, USA
1 shared publication - Cory N. Newton
Department of Mechanical Engineering, Brigham Young University, Provo, UT 84602, USA
1 shared publication
Latest Publications
- Open Access
Foam Pressure Mapping with Optimized Electrodes
Nano-composite piezo-responsive foam (NCPF) is an inexpensive foam that can be used to measure a static load while still providing a comfortable interface. The purpose of this study was to create a modularized foam-based pressure measurement system. A measurement system was developed that uses an interdigitated electrode applied to the NCPF. Applied pressure changes the impedance of the NCPF, which, in turn, is converted into a voltage using a voltage divider. A modular measurement system is described that uses an ATtiny 1627 microcontroller to measure the pressure at nine electrodes. The nine electrode modules are controlled by an ESP32 microcontroller that aggregates the data and wirelessly transmits the data to a tablet. The modular system was demonstrated with 1008 individual electrodes. The characterization of the electrode combined with the NCPF is presented, along with optimization of the electrode geometry.
Open AccessFoam Pressure Mapping with Optimized Electrodes
Nano-composite piezo-responsive foam (NCPF) is an inexpensive foam that can be used to measure a static load while still providing a comfortable interface. The purpose of this study was to create a modularized foam-based pressure measurement system. A measurement system was developed that uses an interdigitated electrode applied to the NCPF. Applied pressure changes the impedance of the NCPF, which, in turn, is converted into a voltage using a voltage divider. A modular measurement system is described that uses an ATtiny 1627 microcontroller to measure the pressure at nine electrodes. The nine electrode modules are controlled by an ESP32 microcontroller that aggregates the data and wirelessly transmits the data to a tablet. The modular system was demonstrated with 1008 individual electrodes. The characterization of the electrode combined with the NCPF is presented, along with optimization of the electrode geometry.
- Open Access
Dual-Sensing Piezoresponsive Foam for Dynamic and Static Loading
Polymeric foams, embedded with nano-scale conductive particles, have previously been shown to display quasi-piezoelectric (QPE) properties; i.e., they produce a voltage in response to rapid deformation. This behavior has been utilized to sense impact and vibration in foam components, such as in sports padding and vibration-isolating pads. However, a detailed characterization of the sensing behavior has not been undertaken. Furthermore, the potential for sensing quasi-static deformation in the same material has not been explored. This paper provides new insights into these self-sensing foams by characterizing voltage response vs frequency of deformation. The correlation between temperature and voltage response is also quantified. Furthermore, a new sensing functionality is observed, in the form of a piezoresistive response to quasi-static deformation. The piezoresistive characteristics are quantified for both in-plane and through-thickness resistance configurations. The new functionality greatly enhances the potential applications for the foam, for example, as insoles that can characterize ground reaction force and pressure during dynamic and/or quasi-static circumstances, or as seat cushioning that can sense pressure and impact.
Open AccessDual-Sensing Piezoresponsive Foam for Dynamic and Static Loading
Polymeric foams, embedded with nano-scale conductive particles, have previously been shown to display quasi-piezoelectric (QPE) properties; i.e., they produce a voltage in response to rapid deformation. This behavior has been utilized to sense impact and vibration in foam components, such as in sports padding and vibration-isolating pads. However, a detailed characterization of the sensing behavior has not been undertaken. Furthermore, the potential for sensing quasi-static deformation in the same material has not been explored. This paper provides new insights into these self-sensing foams by characterizing voltage response vs frequency of deformation. The correlation between temperature and voltage response is also quantified. Furthermore, a new sensing functionality is observed, in the form of a piezoresistive response to quasi-static deformation. The piezoresistive characteristics are quantified for both in-plane and through-thickness resistance configurations. The new functionality greatly enhances the potential applications for the foam, for example, as insoles that can characterize ground reaction force and pressure during dynamic and/or quasi-static circumstances, or as seat cushioning that can sense pressure and impact.
- 25 May 2020
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 38 (16) , 1844-1858
Predicting vertical ground reaction force during running using novel piezoresponsive sensors and accelerometry
Running is a common exercise with numerous health benefits. Vertical ground reaction force (vGRF) influences running injury risk and running performance. Measurement of vGRF during running is now primarily constrained to a laboratory setting. The purpose of this study was to evaluate a new approach to measuring vGRF during running. This approach can be used outside of the laboratory and involves running shoes instrumented with novel piezoresponsive sensors and a standard accelerometer. Thirty-one individuals ran at three different speeds on a force-instrumented treadmill while wearing the instrumented running shoes. vGRF was predicted using data collected from the instrumented shoes, and predicted vGRF were compared to vGRF measured via the treadmill. Per cent error of the resulting predictions varied depending upon the predicted vGRF characteristic. Per cent error was relatively low for predicted vGRF impulse (2–7%), active peak vGRF (3–7%), and ground contact time (3–6%), but relatively high for predicted vGRF load rates (22–29%). These errors should decrease with future iterations of the instrumented shoes and collection of additional data from a more diverse sample. The novel technology described herein might become a feasible way to collect large amounts of vGRF data outside of the traditional biomechanics laboratory.
- 25 May 2020
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 38 (16) , 1844-1858
Predicting vertical ground reaction force during running using novel piezoresponsive sensors and accelerometry
Running is a common exercise with numerous health benefits. Vertical ground reaction force (vGRF) influences running injury risk and running performance. Measurement of vGRF during running is now primarily constrained to a laboratory setting. The purpose of this study was to evaluate a new approach to measuring vGRF during running. This approach can be used outside of the laboratory and involves running shoes instrumented with novel piezoresponsive sensors and a standard accelerometer. Thirty-one individuals ran at three different speeds on a force-instrumented treadmill while wearing the instrumented running shoes. vGRF was predicted using data collected from the instrumented shoes, and predicted vGRF were compared to vGRF measured via the treadmill. Per cent error of the resulting predictions varied depending upon the predicted vGRF characteristic. Per cent error was relatively low for predicted vGRF impulse (2–7%), active peak vGRF (3–7%), and ground contact time (3–6%), but relatively high for predicted vGRF load rates (22–29%). These errors should decrease with future iterations of the instrumented shoes and collection of additional data from a more diverse sample. The novel technology described herein might become a feasible way to collect large amounts of vGRF data outside of the traditional biomechanics laboratory.