Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhuo He has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A New Method of Modeling the Multi-stage Decision-Making Process of CRT Using Machine Learning with Uncertainty Quantification

    by Kristoffer Larsen, Chen Zhao, Zhuo He, Joyce Keyak, Qiuying Sha, Diana Paez, Xinwei Zhang, Guang-Uei Hung, Jiangang Zou, Amalia Peix, et al.

    Current machine learning-based (ML) models usually attempt to utilize all available patient data to predict patient outcomes while ignoring the associated cost and time for data acquisition. The purpose of this study is to create a multi-stage ML model to predict cardiac resynchronization therapy (CRT) response for heart failure (HF) patients. This model exploits uncertainty quantification to recommend additional collection of single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) variables if baseline clinical variables and features from electrocardiogram (ECG) are not sufficient. Two hundred eighteen patients who underwent rest-gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6 ± 1 month follow-up. A multi-stage ML model was created by combining two ensemble models: Ensemble 1 was trained with clinical variables and ECG; Ensemble 2 included Ensemble 1 plus SPECT MPI features. Uncertainty quantification from Ensemble 1 allowed for multi-stage decision-making to determine if the acquisition of SPECT data for a patient is necessary. The performance of the multi-stage model was compared with that of Ensemble models 1 and 2. The response rate for CRT was 55.5% (n = 121) with overall male gender 61.0% (n = 133), an average age of 62.0 ± 11.8, and LVEF of 27.7 ± 11.0. The multi-stage model performed similarly to Ensemble 2 (which utilized the additional SPECT data) with AUC of 0.75 vs. 0.77, accuracy of 0.71 vs. 0.69, sensitivity of 0.70 vs. 0.72, and specificity 0.72 vs. 0.65, respectively. However, the multi-stage model only required SPECT MPI data for 52.7% of the patients across all folds. By using rule-based logic stemming from uncertainty quantification, the multi-stage model was able to reduce the need for additional SPECT MPI data acquisition without significantly sacrificing performance.


  • A New Method Using Deep Learning to Predict the Response to Cardiac Resynchronization Therapy

    by Kristoffer Larsen, Zhuo He, Fernando de A Fernandes, Xinwei Zhang, Chen Zhao, Qiuying Sha, Claudio T Mesquita, Diana Paez, Ernest V. Garcia, Jiangang Zou, et al.

    Clinical parameters measured from gated single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) have value in predicting cardiac resynchronization therapy (CRT) patient outcomes, but still show limitations. The purpose of this study is to combine clinical variables, features from electrocardiogram (ECG), and parameters from assessment of cardiac function with polar maps from gated SPECT MPI through deep learning (DL) to predict CRT response. A total of 218 patients who underwent rest-gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6-month follow-up. A DL model was constructed by combining a pre-trained VGG16 model and a multilayer perceptron. Two modalities of data were input to the model: polar map images from SPECT MPI and tabular data from clinical features, ECG parameters, and SPECT-MPI-derived parameters. Gradient-weighted class activation mapping (Grad-CAM) was applied to the VGG16 model to provide explainability for the polar maps. For comparison, four machine learning (ML) models were trained using only the tabular features. Modeling was performed on 218 patients who underwent CRT implantation with a response rate of 55.5% (n = 121). The DL model demonstrated average AUC (0.83), accuracy (0.73), sensitivity (0.76), and specificity (0.69) surpassing ML models and guideline criteria. Guideline recommendations achieved accuracy (0.53), sensitivity (0.75), and specificity (0.26). The DL model trended towards improvement over the ML models, showcasing the additional predictive benefit of utilizing SPECT MPI polar maps. Incorporating additional patient data directly in the form of medical imagery can improve CRT response prediction.


  • A machine learning method integrating ECG and gated SPECT for cardiac resynchronization therapy decision support

    by Fernando de A. Fernandes, Kristoffer Larsen, Zhuo He, Erivelton Nascimento, Amalia Peix, Qiuying Sha, Diana Paez, Ernest V. Garcia, Weihua Zhou, Claudio T. Mesquita

    Purpose Cardiac resynchronization therapy (CRT) has been established as an important therapy for heart failure. Mechanical dyssynchrony has the potential to predict responders to CRT. The aim of this study was to report the development and the validation of machine learning models which integrate ECG, gated SPECT MPI (GMPS), and clinical variables to predict patients’ response to CRT. Methods This analysis included 153 patients who met criteria for CRT from a prospective cohort study. The variables were used to model predictive methods for CRT. Patients were classified as “responders” for an increase of LVEF ≥ 5% at follow-up. In a second analysis, patients were classified as “super-responders” for an increase of LVEF ≥ 15%. For ML, variable selection was applied, and Prediction Analysis of Microarrays (PAM) approach was used to model response while Naïve Bayes (NB) was used to model super-response. These ML models were compared to models obtained with guideline variables. Results PAM had AUC of 0.80 against 0.72 of partial least squares-discriminant analysis with guideline variables (p = 0.52). The sensitivity (0.86) and specificity (0.75) were better than for guideline alone, sensitivity (0.75) and specificity (0.24). Neural network with guideline variables was better than NB (AUC = 0.93 vs. 0.87) however without statistical significance (p = 0.48). Its sensitivity and specificity (1.0 and 0.75, respectively) were better than guideline alone (0.78 and 0.25, respectively). Conclusions Compared to guideline criteria, ML methods trended toward improved CRT response and super-response prediction. GMPS was central in the acquisition of most parameters. Further studies are needed to validate the models.


  • Open Access

    A new method using deep learning to predict the response to cardiac resynchronization therapy

    by Kristoffer Larsena, Zhuo He, Chen Zhao, Xinwei Zhang, Quiying Sha, Claudio T Mesquitad, Diana Paeze, Ernest V. Garciaf, Jiangang Zou, Amalia Peix, et al.

    Background. Clinical parameters measured from gated single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) have value in predicting cardiac resynchronization therapy (CRT) patient outcomes, but still show limitations. The purpose of this study is to combine clinical variables, features from electrocardiogram (ECG), and parameters from assessment of cardiac function with polarmaps from gated SPECT MPI through deep learning (DL) to predict CRT response. Methods. 218 patients who underwent rest gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6-month follow up. A DL model was constructed by combining a pre-trained VGG16 module and a multilayer perceptron. Two modalities of data were input to the model: polarmap images from SPECT MPI and tabular data from clinical features and ECG parameters. Gradient-weighted Class Activation Mapping (Grad-CAM) was applied to the VGG16 module to provide explainability for the polarmaps. For comparison, four machine learning (ML) models were trained using only the tabular features. Results. Modeling was performed on 218 patients who underwent CRT implantation with a response rate of 55.5% (n = 121). The DL model demonstrated average AUC (0.83), accuracy (0.73), sensitivity (0.76), and specificity (0.69) surpassing the ML models and guideline criteria. Guideline recommendations presented accuracy (0.53), sensitivity (0.75), and specificity (0.26). Conclusions. The DL model outperformed the ML models, showcasing the additional predictive benefit of utilizing SPECT MPI polarmaps. Incorporating additional patient data directly in the form of medical imagery can improve CRT response prediction.

  • Open Access

    A new method using machine learning to integrate ECG and gated SPECT MPI for Cardiac Resynchronization Therapy Decision Support on behalf of the VISION-CRT

    by Fernando de A. Fernandes, Kristoffer Larsen, Zhuo He, Erivelton Nascimento, Amalia Peix, Qiuying Sha, Diana Paez, Ernest V. Garcia, Weihua Zhou, Claudio T Mesquita

    Cardiac resynchronization therapy (CRT) has been established as an important therapy for heart failure. Mechanical dyssynchrony has the potential to predict responders to CRT. The aim of this study was to report the development and the validation of machine learning (ML) models which integrates ECG, gated SPECT MPI (GMPS) and clinical variables to predict patients' response to CRT. This analysis included 153 patients who met criteria for CRT from a prospective cohort study. The variables were used to modeling predictive methods for CRT. Patients were classified as responders for an increase of LVEF>=5% at follow-up. In a second analysis, patients were classified super-responders for increase of LVEF>=15%. For ML, variable selection was applied, and Prediction Analysis of Microarrays (PAM) approach was used for response modeling while Naive Bayes (NB) was used for super-response. They were compared to models obtained with guideline variables. PAM had AUC of 0.80 against 0.71 of logistic regression with guideline variables (p = 0.47). The sensitivity (0.86) and specificity (0.75) were better than for guideline alone, sensitivity (0.72) and specificity (0.22). Neural network with guideline variables outperformed NB (AUC = 0.87 vs 0.86; p = 0.88). Its sensitivity and specificity (1.0 and 0.75, respectively) was better than guideline alone (0.40 and 0.06, respectively). Compared to guideline criteria, ML methods trended towards improved CRT response and super-response prediction. GMPS had a central role in the acquisition of most parameters. Further studies are needed to validate the models.

  • Correction to: Predictive values of left ventricular mechanical dyssynchrony for CRT response in heart failure patients with different pathophysiology

    by Zhuo He, Dianfu Li, Chang Cui, Hui-Yuan Qin, Zhongqiang Zhao, Xiaofeng Hou, Jiangang Zou, Ming-Long Chen, Cheng Wang, Weihua Zhou


  • Open Access

    3D Fusion between Fluoroscopy Angiograms and SPECT Myocardial Perfusion Images to Guide Percutaneous Coronary Intervention

    by Haipeng Tang, Robert R. Bober, Chen Zhao, Chaoyang Zhang, Huiqing Zhu, Zhuo He, Zhihui Xu, Weihua Zhou

    Background. Percutaneous coronary intervention(PCI) in stable coronary artery disease(CAD) is commonly triggered by abnormal myocardial perfusion imaging(MPI). However, due to the possibilities of multivessel disease and variability of coronary artery perfusion distribution, opportunity exists to better align anatomic stenosis with perfusion abnormalities to improve revascularization decisions. This study aims to develop a 3D multi-modality fusion approach to assist decision-making for PCI. Methods. Coronary arteries from fluoroscopic angiography(FA) were reconstructed into 3D artery anatomy. Left ventricular(LV) epicardial surface was extracted from SPECT. The 3D artery anatomy was non-rigidly fused with the LV epicardial surface. The accuracy of the 3D fusion was evaluated via both computer simulation and real patient data. For technical validation, simulated FA and MPI were integrated and then compared with the ground truth from a digital phantom. For clinical validation, FA and SPECT images were integrated and then compared with the ground truth from CT angiograms. Results. In the technical evaluation, the distance-based mismatch error between simulated fluoroscopy and phantom arteries is 1.86(SD:1.43)mm for left coronary arteries(LCA) and 2.21(SD:2.50)mm for right coronary arteries(RCA). In the clinical validation, the distance-based mismatch errors between the fluoroscopy and CT arteries were 3.84(SD:3.15)mm for LCA and 5.55(SD:3.64)mm for RCA. The presence of the corresponding fluoroscopy and CT arteries in the AHA 17-segment model agreed well with a Kappa value of 0.91(95% CI: 0.89-0.93) for LCA and 0.80(CI: 0.67-0.92) for RCA. Conclusions. Our fusion approach is technically accurate to assist PCI decision-making and is clinically feasible to be used in the catheterization laboratory. There is an opportunity to improve the decision-making and outcomes of PCI in stable CAD.

  • Open Access

    Semantic Segmentation to Extract Coronary Arteries in Invasive Coronary Angiograms

    by Chen Zhao, Robert Bober, Haipeng Tang, Jinshan Tang, Minghao Dong, Chaoyang Zhang, Zhuo He, Yu-Ping Wang, Hong-Wen Deng, Michele L. Esposito, et al.

    Coronary artery disease (CAD) is the leading cause of death worldwide, constituting more than one-fourth of global mortalities every year. Accurate semantic segmentation of each artery using invasive coronary angiography (ICA) is important for stenosis assessment and CAD diagnosis. However, due to the morphological similarity among different types of arteries, it is challenging for deep-learning-based models to generate semantic segmentation with an end-to-end approach. In this paper, we propose a multi-step semantic segmentation algorithm based on the analysis of arterial segments extracted from ICAs. The proposed algorithm firstly extracts the entire arterial binary mask (binary vascular tree) using a deep learning-based method. Then we extract the centerline of the binary vascular tree and separate it into different arterial segments. Finally, by extracting the underlying arterial topology, position and pixel features, we construct a powerful coronary artery segment classifier based on support vector machine. Each arterial segment is classified into left coronary artery (LCA), left anterior descending (LAD) and other types of arterial segments. We tested the proposed method on a dataset with 225 ICAs and achieved artery classification accuracy of 70.33%. The experimental results show the effectiveness of the proposed algorithm, which provides impressive performance for analyzing the individual arteries in ICAs.