Kristoffer Larsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kristoffer Larsen has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Amalia Peix
Sección de Medicina Nuclear, Instituto de Cardiología y Cirugía Cardiovascular, La Habana, Cuba
6 shared publications - Diana Paez
International Atomic Energy Agency
6 shared publications - Weihua Zhou
Michigan Technological University
6 shared publications - Qiuying Sha
Michigan Technological University, USA
5 shared publications - Zhuo He
Department of Applied Computing, Michigan Technological University, Houghton, USA
5 shared publications - Claudio Tinoco Mesquita
Universidade Federal Fluminense
4 shared publications
Latest Publications
- 19 September 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (3) , 2290-2308
A New Method of Modeling the Multi-stage Decision-Making Process of CRT Using Machine Learning with Uncertainty Quantification
Current machine learning-based (ML) models usually attempt to utilize all available patient data to predict patient outcomes while ignoring the associated cost and time for data acquisition. The purpose of this study is to create a multi-stage ML model to predict cardiac resynchronization therapy (CRT) response for heart failure (HF) patients. This model exploits uncertainty quantification to recommend additional collection of single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) variables if baseline clinical variables and features from electrocardiogram (ECG) are not sufficient. Two hundred eighteen patients who underwent rest-gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6 ± 1 month follow-up. A multi-stage ML model was created by combining two ensemble models: Ensemble 1 was trained with clinical variables and ECG; Ensemble 2 included Ensemble 1 plus SPECT MPI features. Uncertainty quantification from Ensemble 1 allowed for multi-stage decision-making to determine if the acquisition of SPECT data for a patient is necessary. The performance of the multi-stage model was compared with that of Ensemble models 1 and 2. The response rate for CRT was 55.5% (n = 121) with overall male gender 61.0% (n = 133), an average age of 62.0 ± 11.8, and LVEF of 27.7 ± 11.0. The multi-stage model performed similarly to Ensemble 2 (which utilized the additional SPECT data) with AUC of 0.75 vs. 0.77, accuracy of 0.71 vs. 0.69, sensitivity of 0.70 vs. 0.72, and specificity 0.72 vs. 0.65, respectively. However, the multi-stage model only required SPECT MPI data for 52.7% of the patients across all folds. By using rule-based logic stemming from uncertainty quantification, the multi-stage model was able to reduce the need for additional SPECT MPI data acquisition without significantly sacrificing performance.
- 19 September 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (3) , 2290-2308
A New Method of Modeling the Multi-stage Decision-Making Process of CRT Using Machine Learning with Uncertainty Quantification
Current machine learning-based (ML) models usually attempt to utilize all available patient data to predict patient outcomes while ignoring the associated cost and time for data acquisition. The purpose of this study is to create a multi-stage ML model to predict cardiac resynchronization therapy (CRT) response for heart failure (HF) patients. This model exploits uncertainty quantification to recommend additional collection of single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) variables if baseline clinical variables and features from electrocardiogram (ECG) are not sufficient. Two hundred eighteen patients who underwent rest-gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6 ± 1 month follow-up. A multi-stage ML model was created by combining two ensemble models: Ensemble 1 was trained with clinical variables and ECG; Ensemble 2 included Ensemble 1 plus SPECT MPI features. Uncertainty quantification from Ensemble 1 allowed for multi-stage decision-making to determine if the acquisition of SPECT data for a patient is necessary. The performance of the multi-stage model was compared with that of Ensemble models 1 and 2. The response rate for CRT was 55.5% (n = 121) with overall male gender 61.0% (n = 133), an average age of 62.0 ± 11.8, and LVEF of 27.7 ± 11.0. The multi-stage model performed similarly to Ensemble 2 (which utilized the additional SPECT data) with AUC of 0.75 vs. 0.77, accuracy of 0.71 vs. 0.69, sensitivity of 0.70 vs. 0.72, and specificity 0.72 vs. 0.65, respectively. However, the multi-stage model only required SPECT MPI data for 52.7% of the patients across all folds. By using rule-based logic stemming from uncertainty quantification, the multi-stage model was able to reduce the need for additional SPECT MPI data acquisition without significantly sacrificing performance.
- 20 February 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (6) , 4029-4045
A New Method Using Deep Learning to Predict the Response to Cardiac Resynchronization Therapy
Clinical parameters measured from gated single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) have value in predicting cardiac resynchronization therapy (CRT) patient outcomes, but still show limitations. The purpose of this study is to combine clinical variables, features from electrocardiogram (ECG), and parameters from assessment of cardiac function with polar maps from gated SPECT MPI through deep learning (DL) to predict CRT response. A total of 218 patients who underwent rest-gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6-month follow-up. A DL model was constructed by combining a pre-trained VGG16 model and a multilayer perceptron. Two modalities of data were input to the model: polar map images from SPECT MPI and tabular data from clinical features, ECG parameters, and SPECT-MPI-derived parameters. Gradient-weighted class activation mapping (Grad-CAM) was applied to the VGG16 model to provide explainability for the polar maps. For comparison, four machine learning (ML) models were trained using only the tabular features. Modeling was performed on 218 patients who underwent CRT implantation with a response rate of 55.5% (n = 121). The DL model demonstrated average AUC (0.83), accuracy (0.73), sensitivity (0.76), and specificity (0.69) surpassing ML models and guideline criteria. Guideline recommendations achieved accuracy (0.53), sensitivity (0.75), and specificity (0.26). The DL model trended towards improvement over the ML models, showcasing the additional predictive benefit of utilizing SPECT MPI polar maps. Incorporating additional patient data directly in the form of medical imagery can improve CRT response prediction.
- 20 February 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (6) , 4029-4045
A New Method Using Deep Learning to Predict the Response to Cardiac Resynchronization Therapy
Clinical parameters measured from gated single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) have value in predicting cardiac resynchronization therapy (CRT) patient outcomes, but still show limitations. The purpose of this study is to combine clinical variables, features from electrocardiogram (ECG), and parameters from assessment of cardiac function with polar maps from gated SPECT MPI through deep learning (DL) to predict CRT response. A total of 218 patients who underwent rest-gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6-month follow-up. A DL model was constructed by combining a pre-trained VGG16 model and a multilayer perceptron. Two modalities of data were input to the model: polar map images from SPECT MPI and tabular data from clinical features, ECG parameters, and SPECT-MPI-derived parameters. Gradient-weighted class activation mapping (Grad-CAM) was applied to the VGG16 model to provide explainability for the polar maps. For comparison, four machine learning (ML) models were trained using only the tabular features. Modeling was performed on 218 patients who underwent CRT implantation with a response rate of 55.5% (n = 121). The DL model demonstrated average AUC (0.83), accuracy (0.73), sensitivity (0.76), and specificity (0.69) surpassing ML models and guideline criteria. Guideline recommendations achieved accuracy (0.53), sensitivity (0.75), and specificity (0.26). The DL model trended towards improvement over the ML models, showcasing the additional predictive benefit of utilizing SPECT MPI polar maps. Incorporating additional patient data directly in the form of medical imagery can improve CRT response prediction.
- Open Access
A new method of modeling the multi-stage decision-making process of CRT using machine learning with uncertainty quantification
Aims. The purpose of this study is to create a multi-stage machine learning model to predict cardiac resynchronization therapy (CRT) response for heart failure (HF) patients. This model exploits uncertainty quantification to recommend additional collection of single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) variables if baseline clinical variables and features from electrocardiogram (ECG) are not sufficient. Methods. 218 patients who underwent rest-gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6+-1 month follow-up. A multi-stage ML model was created by combining two ensemble models: Ensemble 1 was trained with clinical variables and ECG; Ensemble 2 included Ensemble 1 plus SPECT MPI features. Uncertainty quantification from Ensemble 1 allowed for multi-stage decision-making to determine if the acquisition of SPECT data for a patient is necessary. The performance of the multi-stage model was compared with that of Ensemble models 1 and 2. Results. The response rate for CRT was 55.5% (n = 121) with overall male gender 61.0% (n = 133), an average age of 62.0+-11.8, and LVEF of 27.7+-11.0. The multi-stage model performed similarly to Ensemble 2 (which utilized the additional SPECT data) with AUC of 0.75 vs. 0.77, accuracy of 0.71 vs. 0.69, sensitivity of 0.70 vs. 0.72, and specificity 0.72 vs. 0.65, respectively. However, the multi-stage model only required SPECT MPI data for 52.7% of the patients across all folds. Conclusions. By using rule-based logic stemming from uncertainty quantification, the multi-stage model was able to reduce the need for additional SPECT MPI data acquisition without sacrificing performance.
Open AccessA new method of modeling the multi-stage decision-making process of CRT using machine learning with uncertainty quantification
Aims. The purpose of this study is to create a multi-stage machine learning model to predict cardiac resynchronization therapy (CRT) response for heart failure (HF) patients. This model exploits uncertainty quantification to recommend additional collection of single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) variables if baseline clinical variables and features from electrocardiogram (ECG) are not sufficient. Methods. 218 patients who underwent rest-gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6+-1 month follow-up. A multi-stage ML model was created by combining two ensemble models: Ensemble 1 was trained with clinical variables and ECG; Ensemble 2 included Ensemble 1 plus SPECT MPI features. Uncertainty quantification from Ensemble 1 allowed for multi-stage decision-making to determine if the acquisition of SPECT data for a patient is necessary. The performance of the multi-stage model was compared with that of Ensemble models 1 and 2. Results. The response rate for CRT was 55.5% (n = 121) with overall male gender 61.0% (n = 133), an average age of 62.0+-11.8, and LVEF of 27.7+-11.0. The multi-stage model performed similarly to Ensemble 2 (which utilized the additional SPECT data) with AUC of 0.75 vs. 0.77, accuracy of 0.71 vs. 0.69, sensitivity of 0.70 vs. 0.72, and specificity 0.72 vs. 0.65, respectively. However, the multi-stage model only required SPECT MPI data for 52.7% of the patients across all folds. Conclusions. By using rule-based logic stemming from uncertainty quantification, the multi-stage model was able to reduce the need for additional SPECT MPI data acquisition without sacrificing performance.
- 17 May 2023
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 50 (10) , 3022-3033
A machine learning method integrating ECG and gated SPECT for cardiac resynchronization therapy decision support
Purpose Cardiac resynchronization therapy (CRT) has been established as an important therapy for heart failure. Mechanical dyssynchrony has the potential to predict responders to CRT. The aim of this study was to report the development and the validation of machine learning models which integrate ECG, gated SPECT MPI (GMPS), and clinical variables to predict patients’ response to CRT. Methods This analysis included 153 patients who met criteria for CRT from a prospective cohort study. The variables were used to model predictive methods for CRT. Patients were classified as “responders” for an increase of LVEF ≥ 5% at follow-up. In a second analysis, patients were classified as “super-responders” for an increase of LVEF ≥ 15%. For ML, variable selection was applied, and Prediction Analysis of Microarrays (PAM) approach was used to model response while Naïve Bayes (NB) was used to model super-response. These ML models were compared to models obtained with guideline variables. Results PAM had AUC of 0.80 against 0.72 of partial least squares-discriminant analysis with guideline variables (p = 0.52). The sensitivity (0.86) and specificity (0.75) were better than for guideline alone, sensitivity (0.75) and specificity (0.24). Neural network with guideline variables was better than NB (AUC = 0.93 vs. 0.87) however without statistical significance (p = 0.48). Its sensitivity and specificity (1.0 and 0.75, respectively) were better than guideline alone (0.78 and 0.25, respectively). Conclusions Compared to guideline criteria, ML methods trended toward improved CRT response and super-response prediction. GMPS was central in the acquisition of most parameters. Further studies are needed to validate the models.
- 17 May 2023
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 50 (10) , 3022-3033
A machine learning method integrating ECG and gated SPECT for cardiac resynchronization therapy decision support
Purpose Cardiac resynchronization therapy (CRT) has been established as an important therapy for heart failure. Mechanical dyssynchrony has the potential to predict responders to CRT. The aim of this study was to report the development and the validation of machine learning models which integrate ECG, gated SPECT MPI (GMPS), and clinical variables to predict patients’ response to CRT. Methods This analysis included 153 patients who met criteria for CRT from a prospective cohort study. The variables were used to model predictive methods for CRT. Patients were classified as “responders” for an increase of LVEF ≥ 5% at follow-up. In a second analysis, patients were classified as “super-responders” for an increase of LVEF ≥ 15%. For ML, variable selection was applied, and Prediction Analysis of Microarrays (PAM) approach was used to model response while Naïve Bayes (NB) was used to model super-response. These ML models were compared to models obtained with guideline variables. Results PAM had AUC of 0.80 against 0.72 of partial least squares-discriminant analysis with guideline variables (p = 0.52). The sensitivity (0.86) and specificity (0.75) were better than for guideline alone, sensitivity (0.75) and specificity (0.24). Neural network with guideline variables was better than NB (AUC = 0.93 vs. 0.87) however without statistical significance (p = 0.48). Its sensitivity and specificity (1.0 and 0.75, respectively) were better than guideline alone (0.78 and 0.25, respectively). Conclusions Compared to guideline criteria, ML methods trended toward improved CRT response and super-response prediction. GMPS was central in the acquisition of most parameters. Further studies are needed to validate the models.
- Open Access
A new method using deep learning to predict the response to cardiac resynchronization therapy
Background. Clinical parameters measured from gated single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) have value in predicting cardiac resynchronization therapy (CRT) patient outcomes, but still show limitations. The purpose of this study is to combine clinical variables, features from electrocardiogram (ECG), and parameters from assessment of cardiac function with polarmaps from gated SPECT MPI through deep learning (DL) to predict CRT response. Methods. 218 patients who underwent rest gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6-month follow up. A DL model was constructed by combining a pre-trained VGG16 module and a multilayer perceptron. Two modalities of data were input to the model: polarmap images from SPECT MPI and tabular data from clinical features and ECG parameters. Gradient-weighted Class Activation Mapping (Grad-CAM) was applied to the VGG16 module to provide explainability for the polarmaps. For comparison, four machine learning (ML) models were trained using only the tabular features. Results. Modeling was performed on 218 patients who underwent CRT implantation with a response rate of 55.5% (n = 121). The DL model demonstrated average AUC (0.83), accuracy (0.73), sensitivity (0.76), and specificity (0.69) surpassing the ML models and guideline criteria. Guideline recommendations presented accuracy (0.53), sensitivity (0.75), and specificity (0.26). Conclusions. The DL model outperformed the ML models, showcasing the additional predictive benefit of utilizing SPECT MPI polarmaps. Incorporating additional patient data directly in the form of medical imagery can improve CRT response prediction.
Open AccessA new method using deep learning to predict the response to cardiac resynchronization therapy
Background. Clinical parameters measured from gated single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) have value in predicting cardiac resynchronization therapy (CRT) patient outcomes, but still show limitations. The purpose of this study is to combine clinical variables, features from electrocardiogram (ECG), and parameters from assessment of cardiac function with polarmaps from gated SPECT MPI through deep learning (DL) to predict CRT response. Methods. 218 patients who underwent rest gated SPECT MPI were enrolled in this study. CRT response was defined as an increase in left ventricular ejection fraction (LVEF) > 5% at a 6-month follow up. A DL model was constructed by combining a pre-trained VGG16 module and a multilayer perceptron. Two modalities of data were input to the model: polarmap images from SPECT MPI and tabular data from clinical features and ECG parameters. Gradient-weighted Class Activation Mapping (Grad-CAM) was applied to the VGG16 module to provide explainability for the polarmaps. For comparison, four machine learning (ML) models were trained using only the tabular features. Results. Modeling was performed on 218 patients who underwent CRT implantation with a response rate of 55.5% (n = 121). The DL model demonstrated average AUC (0.83), accuracy (0.73), sensitivity (0.76), and specificity (0.69) surpassing the ML models and guideline criteria. Guideline recommendations presented accuracy (0.53), sensitivity (0.75), and specificity (0.26). Conclusions. The DL model outperformed the ML models, showcasing the additional predictive benefit of utilizing SPECT MPI polarmaps. Incorporating additional patient data directly in the form of medical imagery can improve CRT response prediction.
- Open Access
A new method using machine learning to integrate ECG and gated SPECT MPI for Cardiac Resynchronization Therapy Decision Support on behalf of the VISION-CRT
Cardiac resynchronization therapy (CRT) has been established as an important therapy for heart failure. Mechanical dyssynchrony has the potential to predict responders to CRT. The aim of this study was to report the development and the validation of machine learning (ML) models which integrates ECG, gated SPECT MPI (GMPS) and clinical variables to predict patients' response to CRT. This analysis included 153 patients who met criteria for CRT from a prospective cohort study. The variables were used to modeling predictive methods for CRT. Patients were classified as responders for an increase of LVEF>=5% at follow-up. In a second analysis, patients were classified super-responders for increase of LVEF>=15%. For ML, variable selection was applied, and Prediction Analysis of Microarrays (PAM) approach was used for response modeling while Naive Bayes (NB) was used for super-response. They were compared to models obtained with guideline variables. PAM had AUC of 0.80 against 0.71 of logistic regression with guideline variables (p = 0.47). The sensitivity (0.86) and specificity (0.75) were better than for guideline alone, sensitivity (0.72) and specificity (0.22). Neural network with guideline variables outperformed NB (AUC = 0.87 vs 0.86; p = 0.88). Its sensitivity and specificity (1.0 and 0.75, respectively) was better than guideline alone (0.40 and 0.06, respectively). Compared to guideline criteria, ML methods trended towards improved CRT response and super-response prediction. GMPS had a central role in the acquisition of most parameters. Further studies are needed to validate the models.
Open AccessA new method using machine learning to integrate ECG and gated SPECT MPI for Cardiac Resynchronization Therapy Decision Support on behalf of the VISION-CRT
Cardiac resynchronization therapy (CRT) has been established as an important therapy for heart failure. Mechanical dyssynchrony has the potential to predict responders to CRT. The aim of this study was to report the development and the validation of machine learning (ML) models which integrates ECG, gated SPECT MPI (GMPS) and clinical variables to predict patients' response to CRT. This analysis included 153 patients who met criteria for CRT from a prospective cohort study. The variables were used to modeling predictive methods for CRT. Patients were classified as responders for an increase of LVEF>=5% at follow-up. In a second analysis, patients were classified super-responders for increase of LVEF>=15%. For ML, variable selection was applied, and Prediction Analysis of Microarrays (PAM) approach was used for response modeling while Naive Bayes (NB) was used for super-response. They were compared to models obtained with guideline variables. PAM had AUC of 0.80 against 0.71 of logistic regression with guideline variables (p = 0.47). The sensitivity (0.86) and specificity (0.75) were better than for guideline alone, sensitivity (0.72) and specificity (0.22). Neural network with guideline variables outperformed NB (AUC = 0.87 vs 0.86; p = 0.88). Its sensitivity and specificity (1.0 and 0.75, respectively) was better than guideline alone (0.40 and 0.06, respectively). Compared to guideline criteria, ML methods trended towards improved CRT response and super-response prediction. GMPS had a central role in the acquisition of most parameters. Further studies are needed to validate the models.