Ana Paula Maran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ana Paula Maran has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Denise Carpena Coitinho Dal Molin
Universidade Federal do Rio Grande do Sul
3 shared publications - Maria Fernanda Fávero Menna Barreto
Universidade Federal do Rio Grande do Sul, Brasil
3 shared publications - João Ricardo Masuero
Universidade Federal do Rio Grande do Sul
2 shared publications - Rafaela Falcão Socoloski
Universidade Federal de Santa Maria
2 shared publications - Abrahão Bernardo Rohden
Universidade Regional de Blumenau, Brasil
1 shared publication - Angela Borges Masuero
Universidade Federal do Rio Grande do Sul
1 shared publication
Latest Publications
- Open Access
- 8 November 2024
- Published by Universidade Federal de Santa Maria in Ciência e Natura
- Vol. 46 (esp. 3) , e87077
Utilização da água proveniente de aparelhos de ar condicionado para fins não potáveis: estimativa do volume gerado
Cada vez mais aparelhos de ar condicionado são utilizados em edificações de uso comercial e residencial. É de conhecimento que a utilização desses aparelhos provoca a condensação de água gerando um gotejamento que, geralmente, é conectado ao sistema de esgotamento, sendo desprezada ou até mesmo negligenciada, ocasionando manifestações patológicas nas edificações e em seu entorno. Além disso, a escassez de água também é cada vez um problema mais recorrente, devido às épocas de seca e, sendo assim, todo o aproveitamento de recursos hídricos possível deve ser realizado. O presente trabalho tem por objetivo analisar a quantidade de água condensada por um aparelho de ar condicionado localizado no Campus de Cachoeira do Sul da Universidade Federal de Santa Maria e verificar possíveis relações com a temperatura e umidade do ar. Para isso foram feitos testes de uma hora de funcionamento em um aparelho localizado em uma sala de aula da Universidade, nos quais foram medidos parâmetros como temperaturas e umidades do ar, externas e internas à sala de aula e o volume de água gerado ao final. Foi verificado que a quantidade de água gerada é significativa, com média de 1662 ml, sendo a maior quantidade gerada em um período de uma hora com temperatura e umidade alta e menor quantidade em dia com os mesmos parâmetros significantemente inferiores.
- 8 November 2024
- Published by Universidade Federal de Santa Maria in Ciência e Natura
- Vol. 46 (esp. 3) , e87077
Open AccessUtilização da água proveniente de aparelhos de ar condicionado para fins não potáveis: estimativa do volume gerado
Cada vez mais aparelhos de ar condicionado são utilizados em edificações de uso comercial e residencial. É de conhecimento que a utilização desses aparelhos provoca a condensação de água gerando um gotejamento que, geralmente, é conectado ao sistema de esgotamento, sendo desprezada ou até mesmo negligenciada, ocasionando manifestações patológicas nas edificações e em seu entorno. Além disso, a escassez de água também é cada vez um problema mais recorrente, devido às épocas de seca e, sendo assim, todo o aproveitamento de recursos hídricos possível deve ser realizado. O presente trabalho tem por objetivo analisar a quantidade de água condensada por um aparelho de ar condicionado localizado no Campus de Cachoeira do Sul da Universidade Federal de Santa Maria e verificar possíveis relações com a temperatura e umidade do ar. Para isso foram feitos testes de uma hora de funcionamento em um aparelho localizado em uma sala de aula da Universidade, nos quais foram medidos parâmetros como temperaturas e umidades do ar, externas e internas à sala de aula e o volume de água gerado ao final. Foi verificado que a quantidade de água gerada é significativa, com média de 1662 ml, sendo a maior quantidade gerada em um período de uma hora com temperatura e umidade alta e menor quantidade em dia com os mesmos parâmetros significantemente inferiores.
- Open Access
- 8 November 2024
- Published by Universidade Federal de Santa Maria in Ciência e Natura
- Vol. 46 (esp. 3) , e87082
Mapeamento de manifestações patológicas em fachada de edificação com revestimento de argamassa na Universidade Federal de Santa Maria - Campus Cachoeira do Sul
A exposição das fachadas com revestimento em argamassa aos agentes climáticos pode resultar no desenvolvimento de manifestações patológicas. A fachada, por sua vez, faz parte do sistema de vedação vertical externo, com função fundamental não apenas estética, mas também como proteção contra intempéries, barreira acústica e térmica para o interior do edifício. Ressalta-se que a deterioração do revestimento de argamassa envolve fatores físicos, mecânicos, químicos e biológicos, exigindo especificações detalhadas de projeto, considerando as condições locais de exposição de cada fachada da edificação. O objetivo deste trabalho foi a análise da fachada da edificação D1 da Universidade Federal de Santa Maria, campus Cachoeira do Sul, através de parte do método de mensuração da degradação (MMD). Como resultado destaca-se a fachada sul com maior extensão de manifestações patológicas, seguida pelas fachadas leste e norte, sendo a fachada oeste com menor área danificada. Entre as manifestações presentes, destacam-se as fissuras como a mais predominante em todas as orientações cardeais. Dentro deste contexto, este trabalho ressalta a necessidade de compreender os processos de degradação ao longo do tempo para garantir o desempenho dos revestimentos de fachada, planos de manutenção e consequentemente, a durabilidade da edificação.
- 8 November 2024
- Published by Universidade Federal de Santa Maria in Ciência e Natura
- Vol. 46 (esp. 3) , e87082
Open AccessMapeamento de manifestações patológicas em fachada de edificação com revestimento de argamassa na Universidade Federal de Santa Maria - Campus Cachoeira do Sul
A exposição das fachadas com revestimento em argamassa aos agentes climáticos pode resultar no desenvolvimento de manifestações patológicas. A fachada, por sua vez, faz parte do sistema de vedação vertical externo, com função fundamental não apenas estética, mas também como proteção contra intempéries, barreira acústica e térmica para o interior do edifício. Ressalta-se que a deterioração do revestimento de argamassa envolve fatores físicos, mecânicos, químicos e biológicos, exigindo especificações detalhadas de projeto, considerando as condições locais de exposição de cada fachada da edificação. O objetivo deste trabalho foi a análise da fachada da edificação D1 da Universidade Federal de Santa Maria, campus Cachoeira do Sul, através de parte do método de mensuração da degradação (MMD). Como resultado destaca-se a fachada sul com maior extensão de manifestações patológicas, seguida pelas fachadas leste e norte, sendo a fachada oeste com menor área danificada. Entre as manifestações presentes, destacam-se as fissuras como a mais predominante em todas as orientações cardeais. Dentro deste contexto, este trabalho ressalta a necessidade de compreender os processos de degradação ao longo do tempo para garantir o desempenho dos revestimentos de fachada, planos de manutenção e consequentemente, a durabilidade da edificação.
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 15 (2)
Computational and experimental simulation to analyze loss in concrete cover by reinforcement deformation in solid slabs
Adequate cover thickness contributes to the correct performance of reinforced concrete structures. Spacers are recommended in standards to maintain a concrete cover; however, many regulations do not provide sufficient guidelines for their use, resulting in poor construction. A research program was developed for solid slabs through computational and experimental simulations to minimize errors in the cover by assessing different reinforcement bar diameters and spacer distribution, considering realistic element construction and standards, combining theory with practice. The results show that the use of spacers does not guarantee the design cover for some reinforcement bar diameters, as 4.2 and 5.0 mm, and regardless of the spacer distribution configuration assessed, these meshes undergo permanent deformation, thereby damaging the cover and consequently impact structural performance. Meshes of 6.3 and 8.0 mm diameters present deformation within the cover tolerance. Therefore, it is preferable to choose bigger diameters and larger mesh spacing to guarantee the projected cover, contributing to the correct performance of the structures, solving one of the major problems in this type of construction.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 15 (2)
Open AccessComputational and experimental simulation to analyze loss in concrete cover by reinforcement deformation in solid slabs
Adequate cover thickness contributes to the correct performance of reinforced concrete structures. Spacers are recommended in standards to maintain a concrete cover; however, many regulations do not provide sufficient guidelines for their use, resulting in poor construction. A research program was developed for solid slabs through computational and experimental simulations to minimize errors in the cover by assessing different reinforcement bar diameters and spacer distribution, considering realistic element construction and standards, combining theory with practice. The results show that the use of spacers does not guarantee the design cover for some reinforcement bar diameters, as 4.2 and 5.0 mm, and regardless of the spacer distribution configuration assessed, these meshes undergo permanent deformation, thereby damaging the cover and consequently impact structural performance. Meshes of 6.3 and 8.0 mm diameters present deformation within the cover tolerance. Therefore, it is preferable to choose bigger diameters and larger mesh spacing to guarantee the projected cover, contributing to the correct performance of the structures, solving one of the major problems in this type of construction.
- Open Access
- 1 July 2020
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 20 (3) , 671-686
Influência da distribuição de espaçadores no cobrimento e na vida útil de lajes maciças
Resumo Para estruturas de concreto armado, a proteção das armaduras é fator fundamental para atingir o desempenho, e isso se dá através da qualidade do concreto e da espessura do cobrimento. Pesquisas apontam negligências quanto à especificação do cobrimento e a ineficácia dos procedimentos de execução. Como resultado, espessuras inadequadas são cada vez mais recorrentes. A falta de clareza das normas de execução quanto à distribuição dos espaçadores para obtenção do cobrimento projetado contribui para o agravamento da situação. Esta pesquisa consiste em um estudo de caso com diferentes distribuições entre espaçadores para a armadura positiva em lajes (padrão de obra e espaçamentos controlados de 20 cm, 40 cm, 60 cm e 80 cm). Tem-se como objetivo comparar as espessuras de cobrimento antes e depois da concretagem, associá-las à vida útil normativa e avaliar se as normas de projeto e execução são suficientes para auxiliar na obtenção do cobrimento. Constatou-se que o cobrimento mínimo para garantir a vida útil de projeto não é totalmente alcançado, porém o controle de execução e um método de disposição dos espaçadores influenciam significativamente a obtenção do cobrimento, sendo a distribuição entre espaçadores de 40 cm a que obteve melhor desempenho entre os espaçamentos avaliados.
- 1 July 2020
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 20 (3) , 671-686
Open AccessInfluência da distribuição de espaçadores no cobrimento e na vida útil de lajes maciças
Resumo Para estruturas de concreto armado, a proteção das armaduras é fator fundamental para atingir o desempenho, e isso se dá através da qualidade do concreto e da espessura do cobrimento. Pesquisas apontam negligências quanto à especificação do cobrimento e a ineficácia dos procedimentos de execução. Como resultado, espessuras inadequadas são cada vez mais recorrentes. A falta de clareza das normas de execução quanto à distribuição dos espaçadores para obtenção do cobrimento projetado contribui para o agravamento da situação. Esta pesquisa consiste em um estudo de caso com diferentes distribuições entre espaçadores para a armadura positiva em lajes (padrão de obra e espaçamentos controlados de 20 cm, 40 cm, 60 cm e 80 cm). Tem-se como objetivo comparar as espessuras de cobrimento antes e depois da concretagem, associá-las à vida útil normativa e avaliar se as normas de projeto e execução são suficientes para auxiliar na obtenção do cobrimento. Constatou-se que o cobrimento mínimo para garantir a vida útil de projeto não é totalmente alcançado, porém o controle de execução e um método de disposição dos espaçadores influenciam significativamente a obtenção do cobrimento, sendo a distribuição entre espaçadores de 40 cm a que obteve melhor desempenho entre os espaçamentos avaliados.
- Open Access
- 1 October 2015
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 8 (5) , 625-643
Assessment of cover to reinforcement in slabs using different spacer and tying distances
Given that the durability of structures is directly related to the thickness of the cover to reinforcement, it is essential to ensure minimum cover is achieved when building a structure. However, studies show that this is not always the case. One of the reasons for the this problem is the lack of indication, in structural projects, of the positioning of spacers. This situation is compounded by the lack of standards and regulations on the use of spacers (i.e. minimum quantities and required layout). This study assesses three different spacer distances and two different tying distances in order to examine the influence of these factors in the cover to reinforcement. To achieve so, three slabs were prepared in situ using different arrangements. After demoulding, cover thickness was determined using a digital covermeter. It was observed that the factors investigated have a significant influence in the final cover.
- 1 October 2015
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 8 (5) , 625-643
Open AccessAssessment of cover to reinforcement in slabs using different spacer and tying distances
Given that the durability of structures is directly related to the thickness of the cover to reinforcement, it is essential to ensure minimum cover is achieved when building a structure. However, studies show that this is not always the case. One of the reasons for the this problem is the lack of indication, in structural projects, of the positioning of spacers. This situation is compounded by the lack of standards and regulations on the use of spacers (i.e. minimum quantities and required layout). This study assesses three different spacer distances and two different tying distances in order to examine the influence of these factors in the cover to reinforcement. To achieve so, three slabs were prepared in situ using different arrangements. After demoulding, cover thickness was determined using a digital covermeter. It was observed that the factors investigated have a significant influence in the final cover.