Nathan Parnell Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nathan Parnell Brown has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- James Matthew Doyle Lane
Sandia National Laboratories
7 shared publications - Marcus David Knudson
Sandia National Laboratories
7 shared publications - Tommy Ao
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
7 shared publications Albuquerque Sandia National Laboratories (Snl-Nm)
5 shared publicationsUsdoe National Nuclear Security Administration (Nnsa)
5 shared publications- David Montes de Oca Zapiain
Sandia National Laboratories
4 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , E09002
Erratum: Erratum: DENNIS: a design and analysis tool for dynamic material x-ray diffraction experiments
- 1 September 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (09) , E09002
Open AccessErratum: Erratum: DENNIS: a design and analysis tool for dynamic material x-ray diffraction experiments
- Open Access
- 1 July 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (07) , E07001
Erratum: DENNIS: a design and analysis tool for dynamic material x-ray diffraction experiments
- 1 July 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (07) , E07001
Open AccessErratum: DENNIS: a design and analysis tool for dynamic material x-ray diffraction experiments
- 30 December 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (2) , 273-276
Application of deep learning to single-shot gas-phase laser-induced breakdown spectroscopy
Single-shot fs laser-induced breakdown spectroscopy (LIBS) has the potential to capture ns-scale electrode desorption phenomena in pulsed power fusion drivers. However, the successful implementation of the diagnostic for this purpose is challenging, as it requires interpreting single-shot measurements collected from low-density gas mixtures. In this work, we demonstrate the efficacy of a Bayesian-optimized convolutional neural network (CNN) to interpret these measurements. We generated 256 distinct measurement conditions at relevant gas pressures ranging from 80–530 mTorr by mixing 100–250 sccm H 2 and 50–200 sccm CH 4 in increments of 10 sccm. Despite the considerable overlap between signals separated by 20 sccm, the CNN is able to predict the H 2 flow rate with a root-mean-square error (RMSE) of 15.9 sccm and the CH 4 flow rate with an RMSE of 12.0 sccm. The average relative prediction error is <9% for each gas and largely remains below or near 10%.
- 30 December 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 51 (2) , 273-276
Application of deep learning to single-shot gas-phase laser-induced breakdown spectroscopy
Single-shot fs laser-induced breakdown spectroscopy (LIBS) has the potential to capture ns-scale electrode desorption phenomena in pulsed power fusion drivers. However, the successful implementation of the diagnostic for this purpose is challenging, as it requires interpreting single-shot measurements collected from low-density gas mixtures. In this work, we demonstrate the efficacy of a Bayesian-optimized convolutional neural network (CNN) to interpret these measurements. We generated 256 distinct measurement conditions at relevant gas pressures ranging from 80–530 mTorr by mixing 100–250 sccm H 2 and 50–200 sccm CH 4 in increments of 10 sccm. Despite the considerable overlap between signals separated by 20 sccm, the CNN is able to predict the H 2 flow rate with a root-mean-square error (RMSE) of 15.9 sccm and the CH 4 flow rate with an RMSE of 12.0 sccm. The average relative prediction error is <9% for each gas and largely remains below or near 10%.
- Open Access
- 24 September 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (12)
Single-shot femtosecond laser-induced breakdown spectroscopy in low-density gases
Single-shot fs laser-induced breakdown spectroscopy (LIBS) has been used to interrogate low-density gases of H2, CH4, CO2, and H2O ranging from 0.5×1015 to 9.1×1015 cm−3 (15–275 mTorr). Strong spectral signatures were observed above the noise baseline for each test gas at all densities considered. Unique molecular signatures were observed for both CH4 and CO2 along with atomic features for each gas. The LIBS intensity response with respect to density was determined for each species using Voigt lineshape fitting or numerical integration. Finally, the collection and analysis of LIBS spectra of composite mixtures of CH4–CO2 and CH4–H2 demonstrates that the extraction of individual densities from gas mixtures is feasible at low densities.
- 24 September 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (12)
Open AccessSingle-shot femtosecond laser-induced breakdown spectroscopy in low-density gases
Single-shot fs laser-induced breakdown spectroscopy (LIBS) has been used to interrogate low-density gases of H2, CH4, CO2, and H2O ranging from 0.5×1015 to 9.1×1015 cm−3 (15–275 mTorr). Strong spectral signatures were observed above the noise baseline for each test gas at all densities considered. Unique molecular signatures were observed for both CH4 and CO2 along with atomic features for each gas. The LIBS intensity response with respect to density was determined for each species using Voigt lineshape fitting or numerical integration. Finally, the collection and analysis of LIBS spectra of composite mixtures of CH4–CO2 and CH4–H2 demonstrates that the extraction of individual densities from gas mixtures is feasible at low densities.
- Open Access
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Genetic algorithm-based geometry calibration for dynamic compression x-ray diffraction experiments
An important component of dynamic compression x-ray diffraction (XRD) experiment analysis is geometry calibration: proper data interpretation requires knowledge of the precise detector position and orientation and, if the experiment involves a single-crystal sample, knowledge of the lattice orientation. The determination of these parameters in the arbitrary three-dimensional (3D) scattering geometries often present in dynamic compression facilities is challenging, as the associated optimization problem can be highly nonlinear, nonsmooth, and discontinuous. We present a genetic algorithm-based approach for performing dynamic compression XRD calibrations that overcomes these obstacles. We provide details regarding the image processing, algorithm implementation, and open-source software deployment and demonstrate the capability of the approach to calibrate the detector and crystal parameters in 3D geometries. Notably, we demonstrate the solver’s capacity to find the crystal orientation without a priori rotation constraints.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Open AccessGenetic algorithm-based geometry calibration for dynamic compression x-ray diffraction experiments
An important component of dynamic compression x-ray diffraction (XRD) experiment analysis is geometry calibration: proper data interpretation requires knowledge of the precise detector position and orientation and, if the experiment involves a single-crystal sample, knowledge of the lattice orientation. The determination of these parameters in the arbitrary three-dimensional (3D) scattering geometries often present in dynamic compression facilities is challenging, as the associated optimization problem can be highly nonlinear, nonsmooth, and discontinuous. We present a genetic algorithm-based approach for performing dynamic compression XRD calibrations that overcomes these obstacles. We provide details regarding the image processing, algorithm implementation, and open-source software deployment and demonstrate the capability of the approach to calibrate the detector and crystal parameters in 3D geometries. Notably, we demonstrate the solver’s capacity to find the crystal orientation without a priori rotation constraints.