Tommy Ao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tommy Ao has a total of 159 co-authors. Here are the top co-authors by number of shared publications:
Albuquerque Sandia National Laboratories (Snl-Nm)
17 shared publications- James Matthew Doyle Lane
Sandia National Laboratories
7 shared publications - Marcus David Knudson
Sandia National Laboratories
7 shared publications - Matthias Geissel
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
7 shared publications - Nathan Parnell Brown
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
7 shared publications Office of Defense Science
7 shared publications
Latest Publications
- 1 May 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (5)
A detailed description of quantitative x-ray spectroscopy using single hit CCD cameras
Deep-depletion charge-coupled device (CCD) cameras can be used as x-ray spectrometers if the flux is limited to significantly less than one photon per pixel. The charge that is created by the absorbed photon is proportional to the x-ray energy, and consequently, the histogram of the CCD-sensor readout (in the limit of no noise and large pixel size) is a strictly linear spectrum. If the quantum efficiency of the detector, the attenuation of x-rays from the source to the detector, and the overall geometry of the setup are known, one can also calculate the absolute flux for a given photon energy from the source. We describe the efficient use of a commercial deep-depletion CCD camera as an absolutely calibrated x-ray spectrometer for the determination of laser-to-x-ray conversion efficiencies with the Z-Petawatt and Z-Beamlet lasers [P. Rambo et al., Proc. SPIE 10014, 100140Z (2016)] at Sandia National Laboratories. We explain procedures to reverse intrinsic degradations of x-ray induced pixel brightness and to mitigate external noise, and we identify spectral artifacts that are generated inside the detector.
- 1 May 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (5)
A detailed description of quantitative x-ray spectroscopy using single hit CCD cameras
Deep-depletion charge-coupled device (CCD) cameras can be used as x-ray spectrometers if the flux is limited to significantly less than one photon per pixel. The charge that is created by the absorbed photon is proportional to the x-ray energy, and consequently, the histogram of the CCD-sensor readout (in the limit of no noise and large pixel size) is a strictly linear spectrum. If the quantum efficiency of the detector, the attenuation of x-rays from the source to the detector, and the overall geometry of the setup are known, one can also calculate the absolute flux for a given photon energy from the source. We describe the efficient use of a commercial deep-depletion CCD camera as an absolutely calibrated x-ray spectrometer for the determination of laser-to-x-ray conversion efficiencies with the Z-Petawatt and Z-Beamlet lasers [P. Rambo et al., Proc. SPIE 10014, 100140Z (2016)] at Sandia National Laboratories. We explain procedures to reverse intrinsic degradations of x-ray induced pixel brightness and to mitigate external noise, and we identify spectral artifacts that are generated inside the detector.
- Open Access
- 12 January 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (2)
Accessing terapascal pressures on two-stage light-gas guns for high-energy-density research
We present pressure amplifiers that have been developed to enable the study of material behavior at terapascal (TPa) pressures using two-stage light-gas gun (2SLGG) facilities. When impacted by a hyper-velocity projectile, Mach reflections within the pressure amplifier eventually merge to form a Mach stem, generating a planar output shock that greatly exceeds the initial drive. Validation experiments demonstrated that peak pressures of 0.6 and 1.073 TPa were achieved in quartz samples for two different amplifier designs. These pressures represent an approximately fivefold increase over the sample pressures typically attainable at 2SLGG facilities. The temporal and spatial uniformity of the pressure drive is suitable for high-precision equation-of-state measurements of materials relative to a shock standard. This work greatly extends the capabilities of 2SLGG facilities and opens new avenues of study in high-energy-density physics using these drivers.
- 12 January 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (2)
Open AccessAccessing terapascal pressures on two-stage light-gas guns for high-energy-density research
We present pressure amplifiers that have been developed to enable the study of material behavior at terapascal (TPa) pressures using two-stage light-gas gun (2SLGG) facilities. When impacted by a hyper-velocity projectile, Mach reflections within the pressure amplifier eventually merge to form a Mach stem, generating a planar output shock that greatly exceeds the initial drive. Validation experiments demonstrated that peak pressures of 0.6 and 1.073 TPa were achieved in quartz samples for two different amplifier designs. These pressures represent an approximately fivefold increase over the sample pressures typically attainable at 2SLGG facilities. The temporal and spatial uniformity of the pressure drive is suitable for high-precision equation-of-state measurements of materials relative to a shock standard. This work greatly extends the capabilities of 2SLGG facilities and opens new avenues of study in high-energy-density physics using these drivers.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
A Bayesian approach to time-domain photonic Doppler velocimetry analysis
Photonic Doppler velocimetry (PDV) is an established technique for measuring the velocities of fast-moving surfaces in high-energy-density experiments. In the standard approach to PDV analysis, the short-time Fourier transform (STFT) is used to generate a spectrogram from which the velocity history of the target is inferred. The user chooses the form, duration, and separation of the window function. Here, we present a Bayesian approach to infer the velocity directly from the PDV oscilloscope trace, without using the spectrogram for analysis. This is clearly a difficult inference problem due to the highly periodic nature of the data, but we find that with carefully chosen prior distributions for the model parameters, we can accurately recover the injected velocity from synthetic data. We validate this method using PDV data collected at the STAR two-stage light gas gun at Sandia National Laboratories, recovering shock-front velocities in quartz that are consistent with those inferred using the STFT-based approach and are interpolated across regions of low signal-to-noise data. Although this method does not rely on the same user choices as the STFT, we caution that it can be prone to misspecification if the chosen model is not sufficient to capture the velocity behavior. Analysis using posterior predictive checks can be used to establish whether a better model is required, although more complex models come with additional computational cost, often taking more than several hours to converge when sampling the Bayesian posterior. We, therefore, recommend it be viewed as a complementary method to that of the STFT-based approach.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
A Bayesian approach to time-domain photonic Doppler velocimetry analysis
Photonic Doppler velocimetry (PDV) is an established technique for measuring the velocities of fast-moving surfaces in high-energy-density experiments. In the standard approach to PDV analysis, the short-time Fourier transform (STFT) is used to generate a spectrogram from which the velocity history of the target is inferred. The user chooses the form, duration, and separation of the window function. Here, we present a Bayesian approach to infer the velocity directly from the PDV oscilloscope trace, without using the spectrogram for analysis. This is clearly a difficult inference problem due to the highly periodic nature of the data, but we find that with carefully chosen prior distributions for the model parameters, we can accurately recover the injected velocity from synthetic data. We validate this method using PDV data collected at the STAR two-stage light gas gun at Sandia National Laboratories, recovering shock-front velocities in quartz that are consistent with those inferred using the STFT-based approach and are interpolated across regions of low signal-to-noise data. Although this method does not rely on the same user choices as the STFT, we caution that it can be prone to misspecification if the chosen model is not sufficient to capture the velocity behavior. Analysis using posterior predictive checks can be used to establish whether a better model is required, although more complex models come with additional computational cost, often taking more than several hours to converge when sampling the Bayesian posterior. We, therefore, recommend it be viewed as a complementary method to that of the STFT-based approach.
- Open Access
- 1 June 2025
- Published by Office of Scientific and Technical Information (OSTI)
Accessing multi-terapascal pressures on two-stage gas guns and pulsed power drivers.
- 1 June 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessAccessing multi-terapascal pressures on two-stage gas guns and pulsed power drivers.
- Open Access
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Genetic algorithm-based geometry calibration for dynamic compression x-ray diffraction experiments
An important component of dynamic compression x-ray diffraction (XRD) experiment analysis is geometry calibration: proper data interpretation requires knowledge of the precise detector position and orientation and, if the experiment involves a single-crystal sample, knowledge of the lattice orientation. The determination of these parameters in the arbitrary three-dimensional (3D) scattering geometries often present in dynamic compression facilities is challenging, as the associated optimization problem can be highly nonlinear, nonsmooth, and discontinuous. We present a genetic algorithm-based approach for performing dynamic compression XRD calibrations that overcomes these obstacles. We provide details regarding the image processing, algorithm implementation, and open-source software deployment and demonstrate the capability of the approach to calibrate the detector and crystal parameters in 3D geometries. Notably, we demonstrate the solver’s capacity to find the crystal orientation without a priori rotation constraints.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Open AccessGenetic algorithm-based geometry calibration for dynamic compression x-ray diffraction experiments
An important component of dynamic compression x-ray diffraction (XRD) experiment analysis is geometry calibration: proper data interpretation requires knowledge of the precise detector position and orientation and, if the experiment involves a single-crystal sample, knowledge of the lattice orientation. The determination of these parameters in the arbitrary three-dimensional (3D) scattering geometries often present in dynamic compression facilities is challenging, as the associated optimization problem can be highly nonlinear, nonsmooth, and discontinuous. We present a genetic algorithm-based approach for performing dynamic compression XRD calibrations that overcomes these obstacles. We provide details regarding the image processing, algorithm implementation, and open-source software deployment and demonstrate the capability of the approach to calibrate the detector and crystal parameters in 3D geometries. Notably, we demonstrate the solver’s capacity to find the crystal orientation without a priori rotation constraints.