Alison Subiantoro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alison Subiantoro has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Kim Tiow Ooi
8 shared publicationsK.T. Ooi
5 shared publications- Ali Naseri
Iranian Central Oil Field Company, Tehran, Iran
3 shared publications - Stuart E. Norris
The University of Auckland
3 shared publications Anarghya Ananda Murthy
Department of Mechanical Engineering, The University of Auckland, Auckland, New Zealand
2 shared publications- Kim Tiow Ooi
Nanyang Technological University
2 shared publications
Latest Publications
- Open Access
Impact of the Lubricant on a Modified Revolving Vane Expander (M-RVE) in an Organic Rankine Cycle System
The expansion device is the critical component of micro-to-small scale organic Rankine cycle (ORC) systems, substantially affecting system efficiency and cost. Low isentropic efficiency and lubrication requirements are the main issues associated with using volumetric expanders in ORC systems. Despite lubrication contributing to reducing internal leakages in an expander, it may compromise the performance of the ORC system by adversely affecting the evaporator’s thermal capacity. This study tests a recently developed and modified revolving vane expander (M-RVE) in a micro-scale ORC test rig by implementing an adjustable oil mass flow rate. The impact of the lubricant oil on the performance of the M-RVE prototype is investigated within a wide range of oil circulation rates (OCR). The results demonstrate a negligible improvement in the filling factor for OCRs higher than 1%. Moreover, the shaft power is not considerably sensitive to OCR, while the calculated isentropic efficiency of the expander improves with OCR. Furthermore, the impact of the lubricant oil on the performance of the evaporator is studied, assuming the exact OCR as the expander and measured temperature and pressure similar to the pure refrigerant for the lubricant-refrigerant mixture in the evaporator. The study shows that the evaporator capacity is penalized with OCR, especially for values higher than 1%. Hence, an OCR of about 1% is a good compromise, and it can be used as a guideline for designing revolving vane expanders for micro-scale ORC systems without a dedicated lubricant oil circuit.
Open AccessImpact of the Lubricant on a Modified Revolving Vane Expander (M-RVE) in an Organic Rankine Cycle System
The expansion device is the critical component of micro-to-small scale organic Rankine cycle (ORC) systems, substantially affecting system efficiency and cost. Low isentropic efficiency and lubrication requirements are the main issues associated with using volumetric expanders in ORC systems. Despite lubrication contributing to reducing internal leakages in an expander, it may compromise the performance of the ORC system by adversely affecting the evaporator’s thermal capacity. This study tests a recently developed and modified revolving vane expander (M-RVE) in a micro-scale ORC test rig by implementing an adjustable oil mass flow rate. The impact of the lubricant oil on the performance of the M-RVE prototype is investigated within a wide range of oil circulation rates (OCR). The results demonstrate a negligible improvement in the filling factor for OCRs higher than 1%. Moreover, the shaft power is not considerably sensitive to OCR, while the calculated isentropic efficiency of the expander improves with OCR. Furthermore, the impact of the lubricant oil on the performance of the evaporator is studied, assuming the exact OCR as the expander and measured temperature and pressure similar to the pure refrigerant for the lubricant-refrigerant mixture in the evaporator. The study shows that the evaporator capacity is penalized with OCR, especially for values higher than 1%. Hence, an OCR of about 1% is a good compromise, and it can be used as a guideline for designing revolving vane expanders for micro-scale ORC systems without a dedicated lubricant oil circuit.
- 1 January 2022
- Published by Elsevier in Energy Conversion and Management
- Vol. 252, 114997
Theoretical modelling and experimental investigation of the modified revolving vane expander (M-RVE)
- 1 January 2022
- Published by Elsevier in Energy Conversion and Management
- Vol. 252, 114997
Theoretical modelling and experimental investigation of the modified revolving vane expander (M-RVE)
- 7 October 2021
- Published by Taylor & Francis in Drying Technology
- Vol. 41 (2) , 190-201
Experimental study of the potential use of an expander for atmospheric freeze-drying
Atmospheric freeze-drying (AFD) is a promising technique that is increasingly popular in drying applications. In this study, a novel method to generate the cold and dry air suitable for AFD applications using an expander is proposed. The concept is simple, able to simultaneously cool and dehumidify air, control the discharged air pressure, and provides the potential for energy saving. An idealized theoretical model to simulate the process was developed. Experiments were conducted at various pressure and speed conditions. The study shows that the expander's maximum volumetric and isentropic efficiencies were 27.2% and 21.8%, respectively. Observation of the internal chamber pressures was able to explain the relatively low isentropic efficiency. The maximum power output and expander efficiency were 56 W and 42.7%, respectively. The expander was able to cool the air to below 0 °C, and the lowest measured outlet air temperature was −8.7 °C. The outlet air relative humidity was between 3.6% to 4.7%. The measured dehumidification effectiveness was between 79.8% to 93.1%. The study shows that the concept is promising, and the expander was able to generate the required air conditions suitable for AFD applications.
- 7 October 2021
- Published by Taylor & Francis in Drying Technology
- Vol. 41 (2) , 190-201
Experimental study of the potential use of an expander for atmospheric freeze-drying
Atmospheric freeze-drying (AFD) is a promising technique that is increasingly popular in drying applications. In this study, a novel method to generate the cold and dry air suitable for AFD applications using an expander is proposed. The concept is simple, able to simultaneously cool and dehumidify air, control the discharged air pressure, and provides the potential for energy saving. An idealized theoretical model to simulate the process was developed. Experiments were conducted at various pressure and speed conditions. The study shows that the expander's maximum volumetric and isentropic efficiencies were 27.2% and 21.8%, respectively. Observation of the internal chamber pressures was able to explain the relatively low isentropic efficiency. The maximum power output and expander efficiency were 56 W and 42.7%, respectively. The expander was able to cool the air to below 0 °C, and the lowest measured outlet air temperature was −8.7 °C. The outlet air relative humidity was between 3.6% to 4.7%. The measured dehumidification effectiveness was between 79.8% to 93.1%. The study shows that the concept is promising, and the expander was able to generate the required air conditions suitable for AFD applications.
- 9 April 2021
- Published by ASME International in Journal of Fluids Engineering
- Vol. 143 (7)
Experimental Investigation of Leakage in the Modified Revolving Vane Expander
This study focuses on the leakage characteristics of a modified revolving vane expander (M-RVE) using both static and dynamic leakage analysis. The no-expansion scenario showed a maximum volumetric efficiency of 18.7% was achieved at 5.5 bar(g) suction pressure, showing the severity of internal leakages. The blocker angle study demonstrated the importance of the correct opening-angle selection to avoid under or over-expansion. The maximum volumetric efficiencies for opening angles of 94 deg and 145 deg were 2.8% and 8.3%, respectively, at suction and discharge pressures of 6.5 bar(g) and 1 atm, respectively. The static leakage test demonstrated that the M-RVE housing was properly sealed, and the observed leakage in the dynamic test was mostly due to internal leakages. The results showed that the leakages through the radial clearance, endface, and vane side gaps make up 54%, 33%, and 8.5% of the overall leakage. Comparison between the theoretical and experimental data of the leakages through the radial clearance gap showed significant deviations at higher suction pressures. The reasons are thought to be due to the shafts' tilt, and the cylinder and rotor head deflections. It is believed that the deflection of the shaft created new leakage paths or changed the geometry of the current paths.
- 9 April 2021
- Published by ASME International in Journal of Fluids Engineering
- Vol. 143 (7)
Experimental Investigation of Leakage in the Modified Revolving Vane Expander
This study focuses on the leakage characteristics of a modified revolving vane expander (M-RVE) using both static and dynamic leakage analysis. The no-expansion scenario showed a maximum volumetric efficiency of 18.7% was achieved at 5.5 bar(g) suction pressure, showing the severity of internal leakages. The blocker angle study demonstrated the importance of the correct opening-angle selection to avoid under or over-expansion. The maximum volumetric efficiencies for opening angles of 94 deg and 145 deg were 2.8% and 8.3%, respectively, at suction and discharge pressures of 6.5 bar(g) and 1 atm, respectively. The static leakage test demonstrated that the M-RVE housing was properly sealed, and the observed leakage in the dynamic test was mostly due to internal leakages. The results showed that the leakages through the radial clearance, endface, and vane side gaps make up 54%, 33%, and 8.5% of the overall leakage. Comparison between the theoretical and experimental data of the leakages through the radial clearance gap showed significant deviations at higher suction pressures. The reasons are thought to be due to the shafts' tilt, and the cylinder and rotor head deflections. It is believed that the deflection of the shaft created new leakage paths or changed the geometry of the current paths.
- Open Access
Torque Characteristics of the Revolving Vane Air Expander
The use of compressed air as an alternative source of clean energy requires an air expander to extract work. A new design, known as the revolving vane mechanism, has been proposed in an effort to develop high efficiency rotary machines. This paper provides an in-depth analysis by including the vibration characteristics of the revolving vane air expander to evaluate the steady-state operating output torque. A generic model for describing the revolving vane rotational vibration is first derived and subsequently modified to describe the prototype tested. Measurements show that the output torque is bimodal; arising from a tolerance gap between the vane and its slot during fabrication. This effect was found to be less pronounced at high operating speeds. The model is found to be in good agreement with the measured output torques. Further analysis with the validated model showed that extracting shaft work from the cylinder would result in better performance.
Open AccessTorque Characteristics of the Revolving Vane Air Expander
The use of compressed air as an alternative source of clean energy requires an air expander to extract work. A new design, known as the revolving vane mechanism, has been proposed in an effort to develop high efficiency rotary machines. This paper provides an in-depth analysis by including the vibration characteristics of the revolving vane air expander to evaluate the steady-state operating output torque. A generic model for describing the revolving vane rotational vibration is first derived and subsequently modified to describe the prototype tested. Measurements show that the output torque is bimodal; arising from a tolerance gap between the vane and its slot during fabrication. This effect was found to be less pronounced at high operating speeds. The model is found to be in good agreement with the measured output torques. Further analysis with the validated model showed that extracting shaft work from the cylinder would result in better performance.
- 1 December 2019
- Published by Elsevier in International Journal of Engineering Science
- Vol. 145
Investigation of electroosmotically induced pressure gradient in rectangular capillaries
- 1 December 2019
- Published by Elsevier in International Journal of Engineering Science
- Vol. 145
Investigation of electroosmotically induced pressure gradient in rectangular capillaries
- Open Access
Thermo-Economic Analysis of A Geothermal Binary Power Plant in Indonesia—A Pre-Feasibility Case Study of the Wayang Windu Site
Indonesia has a predicted geothermal potential of 29 GWe, which is the biggest in the world. With this potential, the government has the ambitious target to generate as much as 7 GWe of electricity in 2025 from geothermal energy. However, the installed capacity of geothermal power plant in Indonesia until 2019 is only 1.9 GWe. Enhancements in already-installed geothermal power plants with a binary power plant can be considered to achieve the 2025 target. In this research, a thermo-economic analysis is carried out to assess the feasibility of binary power systems to enhance the existing geothermal power plants in Indonesia. The Wayang Windu site is selected as the case study. Three working fluids, i.e., n-Pentane, isopentane, and R245fa, are compared. Two different optimization objectives are considered and compared. First, the thermal efficiency is optimized to maximize the thermodynamic performance. In the second scenario, the heat exchanger area is optimized to maximize the economic performance. Analysis of the economic profitability variables, namely the payback period and internal rate of return, shows that optimizing the heat exchangers gives better economic results when compared to optimizing the thermal efficiency. The results also show that the type of working fluid significantly affects both the thermal efficiency and economic profitability of the binary power plant. Moreover, n-Pentane has the most preferred thermo-economic performance for the geothermal conditions at Wayang Windu with the smallest payback period of 13 years and the highest internal rate of return of 11.28%.
Open AccessThermo-Economic Analysis of A Geothermal Binary Power Plant in Indonesia—A Pre-Feasibility Case Study of the Wayang Windu Site
Indonesia has a predicted geothermal potential of 29 GWe, which is the biggest in the world. With this potential, the government has the ambitious target to generate as much as 7 GWe of electricity in 2025 from geothermal energy. However, the installed capacity of geothermal power plant in Indonesia until 2019 is only 1.9 GWe. Enhancements in already-installed geothermal power plants with a binary power plant can be considered to achieve the 2025 target. In this research, a thermo-economic analysis is carried out to assess the feasibility of binary power systems to enhance the existing geothermal power plants in Indonesia. The Wayang Windu site is selected as the case study. Three working fluids, i.e., n-Pentane, isopentane, and R245fa, are compared. Two different optimization objectives are considered and compared. First, the thermal efficiency is optimized to maximize the thermodynamic performance. In the second scenario, the heat exchanger area is optimized to maximize the economic performance. Analysis of the economic profitability variables, namely the payback period and internal rate of return, shows that optimizing the heat exchangers gives better economic results when compared to optimizing the thermal efficiency. The results also show that the type of working fluid significantly affects both the thermal efficiency and economic profitability of the binary power plant. Moreover, n-Pentane has the most preferred thermo-economic performance for the geothermal conditions at Wayang Windu with the smallest payback period of 13 years and the highest internal rate of return of 11.28%.
- 1 October 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 106, 427-446
A review on expanders and their performance in vapour compression refrigeration systems
- 1 October 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 106, 427-446
A review on expanders and their performance in vapour compression refrigeration systems
- 27 September 2018
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (2) , 177-188
Feasibility analysis of the hybrid dehumidifier–air conditioner technology for small-scale household applications in the tropics
Household air conditioners (ACs) with cooling capacities of less than 6 kW are popular in the tropics but are highly energy intensive because of the humid ambient condition. The hybrid dehumidifier–AC concept was studied here to improve the energy efficiency of such systems. Feasibility of the concept was investigated by looking at the design complexity, expected performance, and economic aspects. From the design analysis, it was concluded that small desiccant wheels are most practical for portable and window ACs, while no dehumidification concept was found ideal for split-type room ACs. Performance of the system was benchmarked with data from a 6.4 m2 room under tropical ambient conditions with air change rates of 1–4 changes per hour. It was found that an average load reduction of up to 8.1% was obtainable. The corresponding potential power saving was 9.4%. The performance data were then used for the economic analysis. It was found that the hybrid system is financially attractive mostly when cooling capacity, usage rate, and electricity price are high. Furthermore, the system should have a cooling capacity of at least 4 kW and 4 air changes per hour to be financially justifiable, particularly in places with low electricity prices.
- 27 September 2018
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 25 (2) , 177-188
Feasibility analysis of the hybrid dehumidifier–air conditioner technology for small-scale household applications in the tropics
Household air conditioners (ACs) with cooling capacities of less than 6 kW are popular in the tropics but are highly energy intensive because of the humid ambient condition. The hybrid dehumidifier–AC concept was studied here to improve the energy efficiency of such systems. Feasibility of the concept was investigated by looking at the design complexity, expected performance, and economic aspects. From the design analysis, it was concluded that small desiccant wheels are most practical for portable and window ACs, while no dehumidification concept was found ideal for split-type room ACs. Performance of the system was benchmarked with data from a 6.4 m2 room under tropical ambient conditions with air change rates of 1–4 changes per hour. It was found that an average load reduction of up to 8.1% was obtainable. The corresponding potential power saving was 9.4%. The performance data were then used for the economic analysis. It was found that the hybrid system is financially attractive mostly when cooling capacity, usage rate, and electricity price are high. Furthermore, the system should have a cooling capacity of at least 4 kW and 4 air changes per hour to be financially justifiable, particularly in places with low electricity prices.