JKJulie A. Kiland

Julie A. Kiland

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Julie A. Kiland has a total of 29 co-authors. Here are the top co-authors by number of shared publications:

  • Gillian J. McLellan

    Surgical Sciences University of Wisconsin‐Madison Madison Wisconsin USA

    6 shared publications
  • Kazuya Oikawa

    Surgical Sciences, School of Veterinary Medicine University of Wisconsin‐Madison Madison Wisconsin USA

    4 shared publications
  • Hannah E. Walleck

    Department of Ophthalmology and Visual Sciences, School of Medicine and Public Health University of Wisconsin–Madison Madison Wisconsin USA

    2 shared publications
  • Hannah M. Terhaar

    Department of Surgical Sciences, School of Veterinary Medicine University of Wisconsin–Madison Madison Wisconsin USA

    2 shared publications
  • Jacob P. Nilles

    Department of Surgical Sciences, School of Veterinary Medicine University of Wisconsin‐Madison Madison Wisconsin USA

    2 shared publications
  • Kevin C. Snyder

    Department of Surgical Sciences, School of Veterinary Medicine University of Wisconsin‐Madison Madison Wisconsin USA

    2 shared publications

Latest Publications

  • Open Access

    Topical Omidenepag Isopropyl Lowers Intraocular Pressure in Normal and Glaucomatous Cats: A Pilot Study

    by Kazuya Oikawa, Julie A. Kiland, Hayden G. Zaluckyj, Anjali Rai, Virginia Mathu, Gillian J. McLellan

    Purpose: To evaluate the effects of topical prostaglandin E2 receptor 2 (EP2) agonist, omidenepag isopropyl (OMDI), on intraocular pressure (IOP) and pupil diameter (PD) in normal cats and cats with feline congenital glaucoma (FCG). Animals Studied: Ten FCG cats and 8 normal cats. Methods: In this prospective, randomized, placebo‐controlled, masked pilot study, normal and FCG cats received one drop of 0.002% OMDI ophthalmic solution in one eye and artificial tears in the contralateral eye. IOP and PD were measured by a masked observer at baseline and at multiple time points up to 32–36 h post‐administration. Results: Topical 0.002% OMDI significantly lowered IOP compared to controls in both normal and FCG cats. In normal cats, the effect was significant up to 12 h after instillation, with a maximal reduction from baseline of 7.3 mmHg (43.5%). In FCG cats, the effect was significant from 2 to 8 h after instillation, with a maximal reduction from baseline of 16.7 mmHg (60.2%). No significant effect on pupil diameter or signs of ocular irritation was observed in either group. Conclusions: A single topical drop of 0.002% OMDI significantly lowers IOP in normal and FCG cats without inducing miosis. Our findings support that topical selective EP2 agonists may be a promising therapeutic option for feline glaucoma and provide information relevant to dosing intervals for future studies.


  • Open Access

    Imaging Canine Post‐Trabecular Aqueous Outflow Pathways: Effect of Acute Intraocular Pressure Elevation in Normal Eyes

    by Odalys Torné, Jacob P. Nilles, Andrew L. Smith, Kevin C. Snyder, Kazuya Oikawa, Julie A. Kiland, Mary R. Telle, Mark Banghart, Gillian J. McLellan

    Purpose: To investigate the relationship between increased intraocular pressure (IOP) and the structure of the post‐trabecular aqueous outflow tract of dogs. Methods: Ex vivo aqueous angiography (AA) and anterior segment optical coherence tomography (OCT) were performed concurrently in 19 normal canine eyes, following cannulation and intracameral infusion of 2.5% fluorescein and/or indocyanine green (ICG) after maintaining eyes at physiologic IOP (10–25 mmHg) for 30 min and/or elevated IOP (55–68 mmHg) for 30 or 120 min. Scleral lumen heights (SLH) of vascular profiles in OCT scans were measured by Image J, and values analyzed in linear regression models. In a subset of 10 eyes, each quadrant was subjectively characterized as being either a high‐flow or low‐flow region based on angiographic signal intensity at 2 or 10 min post‐tracer infusion. Results: Segmental AA outflow signal correlated with lumens seen on OCT scleral line scans in healthy canine eyes at physiologic IOP. These lumens were also observed at elevated IOP but appeared collapsed in profile. After both 30 and 120 min of IOP elevation, SLH was significantly reduced ( p < 0.0001). Large vessels tended to collapse more than small vessels after IOP elevation. Conclusion: Acute IOP elevation resulted in a significant reduction in SLH in healthy canine eyes, and the number of AA determined high flow regions was reduced. Future studies to understand the nature and timing of this pressure‐dependent change in the post‐trabecular outflow pathway in glaucomatous eyes, including its potential reversibility, will be crucial in developing novel diagnostic tools and treatments for canine glaucoma.


  • Open Access

    Comparison of Rebound and Applanation Tonometry in Eyes With Focal Corneal Edema

    by Julie A. Kiland, Hannah M. Terhaar, Hannah E. Walleck, Nickolas Chen, Odalys Torné, Kazuya Oikawa, Tina Wahl, Gillian J. McLellan

    Objective: To determine the effect of corneal edema on intraocular pressure (IOP) readings and their accuracy and precision when obtained with handheld rebound and applanation tonometers. Animals and Procedures: IOP readings from areas of focal corneal edema were compared to those from clear cornea in 10 eyes of 7 glaucomatous cats in vivo using TONOVET Plus (TVP) and TONOVET (TV01) rebound, and Tono‐Pen Vet (TP) applanation tonometers. Four different feline eyes with focal corneal edema were cannulated ex vivo and tonometry readings obtained from clear and edematous cornea at set manometric IOPs from 5 to 70 mmHg. Results: Rebound tonometry values were 4.0 ± 5.5 (SD) mmHg lower, and TP values were 13.0 ± 5.9 (SD) mmHg higher in regions of edema versus clear cornea in the same eye ( p = 0.0075). Relative to manometry, TVP and TV01 accuracy and precision were acceptable for clear cornea readings but were negatively impacted by corneal edema. TP‐derived readings grossly underestimated high IOPs relative to manometry in both clear and edematous feline cornea and were significantly less accurate than rebound tonometers in clear cornea ( p = 0.03). All tonometers were less precise in edematous cornea; the TP was significantly less precise than the TV01 ( p = 0.0419). Conclusions: Although IOP values obtained with the TVP and TV01 tend to be less accurate and precise in edematous versus clear cornea, rebound tonometry is impacted by corneal edema to a lesser degree than applanation tonometry. In patients with corneal edema, IOP measurements should be obtained from clear corneal regions when possible.


  • Open Access

    Effects of 0.024% latanoprostene bunod on intraocular pressure and pupil diameter in normal cats and cats with congenital glaucoma

    by Vanessa Y. Yang, J. Seth Eaton, Julie A. Kiland, Kelly E. Koch, Kazuya Oikawa, Scott J. Hetzel, Gillian J. McLellan

    Objective: To evaluate the effects of latanoprostene bunod on intraocular pressure (IOP) and pupil diameter (PD) in normal cats and cats with feline congenital glaucoma (FCG). Animals Studied: Five normal and 5 FCG cats. Procedures: This masked, controlled crossover study comprised a 1‐day Pre‐treatment phase followed by two 10‐day Treatment phases, each followed by a 10‐day Recovery phase. During treatment, all cats received twice daily 0.005% latanoprost (LAT) or 0.024% latanoprostene bunod (LBN) in a randomized eye. Following Recovery, the same eye was treated with the opposite drug. Contralateral eyes served as saline‐treated controls. Intraocular pressure and PD measurements were performed three times daily during all study phases. Data were analyzed via constrained longitudinal data analysis models. Results: Neither drug significantly reduced IOP in normal cats. In FCG cats, statistically significant reductions in mean (95% CI) IOP were observed relative to controls 4 h after LAT and LBN treatment (−5.5 mmHg [−8.4, −2.5], p < .001, −7.2 mmHg [−10.2, −4.3], p < .001, respectively). These differences represented 28.4% and 37.9% IOP reductions, respectively. Mean IOP reduction after 4 h was significantly greater with LBN treatment compared to LAT (−1.8 mmHg [−3.2, −0.4], p = .012). However, these IOP reductions were not considered clinically significant. Both drugs similarly reduced PD in normal and FCG cats. Conclusions: Transient IOP reduction was observed after topical administration of LAT and LBN in FCG cats; and mean IOP difference was statistically significantly greater in LBN‐treated eyes. However, the apparent enhanced hypotensive effect of LBN is not clinically significant.


  • Open Access

    Comparison of theTONOVETPlus®, TonoVet®, and Tono‐Pen Vet™ tonometers in normal cats and cats with glaucoma

    by Julie A. Kiland, Hannah M. Terhaar, Hannah E. Walleck, Nickolas Chen, Kyle McDaniel, Gillian J. McLellan

    Objectives: To determine the accuracy, precision, and clinical applicability of the ICare® TONOVET Plus (TVP) in cats.Animals and Procedures: IOP readings obtained with the TVP were compared to values obtained concurrently with the original TONOVET (TV01) and Tono‐Pen Vet™ (TP) in 12 normal cats (24 eyes) and 8 glaucomatousLTBP2‐mutant cats (13 eyes) in vivo. Reproducibility of TVP readings was also assessed for three observers in the above cats. The anterior chambers of five different normal cat eyes were cannulated ex vivo. IOP was measured with the TVP, TV01, and TP at manometric IOPs ranging from 5 to 70 mmHg. Data were analyzed by linear regression, ANOVA and Bland–Altman plots. ANOVA was used to assess reproducibility of TVP readings obtained by different observers and an ANCOVA model controlled for variation of individual cats.p < .05 was considered significant.Results: TVP values strongly correlated with TV01 values (y = 1.045x + 1.443,R2 = .9667). The TP significantly underestimated IOP relative to the TVP and TV01, particularly at high IOP. IOP values obtained by 1 observer were significantly higher (~1 mmHg average) compared to the other 2 observers via ANCOVA analysis (p = .0006479 andp = .0203). Relative to manometry, the TVP and TV01 were significantly more accurate (p < .0001) and precise (p < .0070) than the TP in ex vivo eyes.Conclusions: IOP readings obtained with the TVP and TV01 are broadly interchangeable between models and between observers, but subtle differences may be important in a research context. TP readings vastly underestimate high IOP in feline glaucoma.


  • Development and validation of methods to visualize conventional aqueous outflow pathways in canine primary angle closure glaucoma

    by Mary Rebecca Telle, Kevin C. Snyder, Kazuya Oikawa, Jacob P. Nilles, Shaile Gehrke, Leandro B. C. Teixeira, Julie A. Kiland, Alex Huang, Gillian J. McLellan

    Purpose: Angle closure glaucoma (PACG) is highly prevalent in dogs and is often refractory to medical therapy. We hypothesized that pathology affecting the post‐trabecular conventional aqueous outflow pathway contributes to persistent intraocular pressure (IOP) elevation in dogs with PACG. The goal of this study was to determine the potential for aqueous angiography (AA) and optical coherence tomography (OCT) to identify abnormalities in post‐trabecular aqueous outflow pathways in canine PACG.Methods: AA and anterior segment OCT (Spectralis HRA + OCT) were performed ex vivo in 19 enucleated canine eyes (10 normal eyes and 9 irreversibly blind eyes from canine patients enucleated for management of refractory PACG). Eyes were cannulated and maintained at physiologic IOP (10–20 mmHg) prior to intracameral infusion of fluorescent tracer. OCT scleral line scans were acquired in regions of high and low perilimbal AA signal. Eyes were then perfusion fixed and cryosections prepared from 10/10 normal and 7/9 PACG eyes and immunolabeled for a vascular endothelial marker.Results: Normal canine eyes showed segmental, circumferential limbal AA signal, whereas PACG eyes showed minimal or no AA signal. AA signal correlated with scleral lumens on OCT in normal dogs, but lumens were generally absent or flattened in PACG eyes. Collapsed vascular profiles were identified in tissue sections from PACG eyes, including those in which no lumens were identified on AA and OCT.Conclusions: In canine eyes with PACG, distal aqueous outflow channels are not identifiable by AA, despite normalization of their IOP, and intra‐scleral vascular profiles are collapsed on OCT and histopathology.


  • Validation and comparison of four handheld tonometers in normal ex vivo canine eyes

    by Andrea L. Minella, Julie A. Kiland, Shawna Gloe, Gillian J. McLellan

    Objectives: To determine the accuracy and precision of the Icare®TONOVET Plus rebound tonometer and the Tono‐Pen AVIA Vet™ applanation tonometer for intraocular pressure (IOP) measurement in normal ex vivo canine eyes and comparison to earlier models of these tonometers.Animals & procedures: The anterior chambers of six normal dog eyes were cannulated ex vivo. IOP was measured with the TONOVET (TV01), TONOVET Plus, Tono‐Pen Vet™, and Tono‐Pen AVIA Vet™ at manometric IOPs ranging from 5 to 70 mm Hg. Data were analyzed by linear regression, ANOVA and Bland‐Altman plots. APvalue ≤ .05 was considered significant.Results: Intraocular pressure values obtained using the TONOVET Plus and TV01 were significantly more accurate than with the Tono‐Pen VET and Tono‐Pen AVIA Vet, particularly at higher IOPs (30‐70 mm Hg). Accuracy was not significantly different between any of the devices in the low to normal physiologic IOP range (5‐25 mm Hg). Level of precision was high for all devices, though the TONOVET Plus was more precise than the Tono‐Pen Vet in the 5‐25 mmHg range and the TV01 was more precise than the Tono‐Pen AVIA Vet over the whole IOP range.Conclusions: All devices underestimated IOP, particularly at higher pressures. Rebound tonometers were more accurate over the full range of IOP tested and in the high IOP range; however, there were no significant differences in accuracy among devices in the physiologic IOP range. All tonometers can provide clinically useful IOP readings in dogs, but rebound and applanation tonometers should not be used interchangeably.