ABAnandaroop Bhattacharya

Anandaroop Bhattacharya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anandaroop Bhattacharya has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Pore-Scale Water–Oil Interfacial Dynamics in Oil-Wet Porous Media

    by Ankit Chourasia, Nikhil V. Giri, Carolyn L. Ren, Sushanta K. Mitra, Anandaroop Bhattacharya

    The reservoir-on-a-chip (RoC) concept, built upon a microfluidics platform, enables real-time visualization of pore-scale flow dynamics, offering a distinct advantage over traditional core flooding. However, most RoC studies rely on idealized pore throat network models generated via Delaunay triangulation, which may not fully capture realistic flow behavior and volume-averaged metrics. This study benchmarks such networks against two alternatives─a physical rock network and an image-extracted pore network, by comparing flow dynamics, saturation evolution, and the volume averaged properties across all three configurations. The physical rock network was derived from Micronit Microtechnologies’ enhanced oil recovery chips. Two additional mathematical pore networks were constructed to simplify geometry: (i) an extracted pore network, derived directly from the physical rock network, and (ii) a statistical pore network, using the same pore locations and dimensions, while connecting throats were generated via Delaunay triangulation. All networks were simulated in COMSOL Multiphysics using the Navier–Stokes–Cahn–Hilliard system of equations to investigate pore-scale multiphase flow behavior and displacement dynamics. Numerical modeling reveals that the invading nonwetting fluid follows path of least resistance through the network, exhibiting both piston-like and concurrent displacement mechanisms. The model captures displacement instabilities characteristic of invasion percolation, along with pore-scale phenomena such as viscous fingering, and snap-off events, including Roof snap-off, Haines jumps, and fluid trapping. A trade-off analysis reveals that the physical rock network provides the most realistic representation of pore-level flow and volume-averaged properties, including recovery factor, Buckley–Leverett saturation history, and relative permeability curves, but requires an inordinately long time to converge. The statistically generated network accelerated convergence by 13 times but overestimated recovery by approximately 23% due to its idealized geometry and enhanced connectivity. The extracted pore network, reconstructed from the image data, achieved a practical balance by retaining key structural features while enabling faster simulation runtimes with minimal loss of accuracy in capturing displacement and saturation trends. These findings emphasize the importance of network selection and demonstrate the utility of the extracted network for scalable, physically grounded multiphase flow modeling.

  • Numerical investigation of plated and disc blower performance and its optimization for portable computing device applications

    by Amit Kumar, Ratul Mali, Abhilasha Niyogi, Srinivas Rao Konakalla, Mark MacDonald, Anandaroop Bhattacharya

    Thermal management of mobile computing devices plays an important role in the performance and reliability of their electronic components. Centrifugal blowers are the most commonly used system-level cooling solution for these devices. In this paper, novel designs of centrifugal blowers called Plated Blowers (PB) and Disc Blowers (DB) are proposed for cooling laptop computers, where the conventional rotor blades are replaced by a new design either comprising of circular sheet metal as a rotor with punched holes and residual hanging chads or discrete blades formed along the disc beside each hole that works to displaces air. It had a similar working principle as Volumetric Resistance Blower (VRB), where the porous disc is replaced by randomly distributed small structures across a circular plate which moves the air within the blower. A numerical study was conducted on these designs to determine the flow rates under an operational angular speed of 6000 RPM. The results showed that both PB and DB designs can outperform the traditional blade fan design as well as the VRB in terms of air volume flow rate at isorpm conditions(not necessarily iso-acoustic). Like VRB which has a porous rotor, the newly discussed designs are also expected to offer a significant acoustic advantage over traditional bladed blowers, which can enable an increase in overall platform power in these mobile computing systems.

  • MACHINE LEARNING MODELS FOR PREDICTING ELECTRICAL AND THERMAL BEHAVIOR IN HIGH-CAPACITY LITHIUM-ION BATTERIES

    by Tuhin Maitra, Amit Patra, Anandaroop Bhattacharya

    The rising prominence of EVs has substantially increased the demand for high-capacity, rechargeable Li-ion batteries, necessitating advanced BMS to ensure reliable and optimized operational performance. Central to BMS functionality is the precise modeling of Li-ion battery behavior, particularly their thermal and electrical dynamics. Given the substantial variance in the nominal capacity of Li-ion pouch cells used in commercial EV battery packs, accurate estimation of heat generation in these cells is crucial for designing an effective battery thermal management system. Traditional BMS applications have typically relied on simplistic equivalent circuit models, which often fail to capture complex thermal behaviors. The advent of cloud-based BMS platforms has introduced the possibility of leveraging machine learning (ML) models, promising enhanced accuracy and reliability. This study examines the efficacy of four distinct sequential cascaded multi-stage ML regression models in predicting the depth of discharge and heat generation responses of Li-ion cells. Experimental trials were conducted on a prismatic 20-Ah Li-ion battery, subjected to cyclic loading under varying ambient temperatures and C-rates. Heat flux and surface temperature readings were diligently gathered, forming the cornerstone for model development and validation. Utilizing Python's Scikit-learn library, different models were trained and evaluated against the experimental dataset, with the coefficient of determination (R2) employed as the performance metric. Among these models, the random forest-based approach demonstrated exceptional proficiency, achieving an R2 score of 0.9994. This result underscores its superiority in accurately capturing the complex thermal and electrical dynamics of Li-ion batteries under diverse operating conditions. The findings highlight the potential of ML-driven approaches to transform BMS design, enabling a more nuanced and accurate understanding of battery behavior, thereby paving the way for safer and more efficient EV battery systems.


  • COOLING ENHANCEMENT THROUGH DC IONIC WIND UNDER NATURAL CONVECTION SENSITIVITY TO ELECTRODE SPACING AND ORIENTATION

    by Saravanan Venkatesh, Amit Kumar, Saurav Pramanik, Sanjay Vijayaraghavan, Krishnendu Saha, Anandaroop Bhattacharya

    Ionic wind is an effective technique to enhance natural convection cooling, as it can generate flow with minimum moving parts and power consumption. This paper presents an experimental investigation of ionic wind for heat transfer enhancement for an aluminium heat sink under natural convection. Experiments were performed at different orientations of the aluminium heat sink to determine the relative impact of buoyancy and EHD driven heat transfer. Tests were conducted for different electrode spacing ranging between 5 mm to 15 mm subjected to 5.64 kV corona voltage and considering three different sets of emitters having varied number of electrodes. Vertical orientation of fin yielded maximum advantage in cooling from ionic wind. The enhancement was significantly affected by the number of electrodes in the emitter and electrode spacing. There exists an optimum electrode number and spacing where the enhancement was found to be maximum. For the present study, it was found to be 10 nos. and 10-mm respectively. The results showed that ionic wind can help reduce the thermal resistance by a factor of up to 2.34 compared to natural convection for vertical arrangement. In case of inclined orientation, results suggested existence of an optimal angle for maximum cooling in presence of ionic wind, where the reduction in thermal resistance was up to a factor of 1.6. The increase in corona voltage from 5.64 kV to 7.05 kV, for optimum spacing, caused the enhancement to increase from 2.34 to 3.09 for 10 number of needle electrodes.


  • Experimental Analysis on Reliability of Needle Electrodes in Ionic Wind

    by Sambhav Prashit Kaphle, Anandaroop Bhattacharya

    Electrohydrodynamic (EHD) cooling has gained prominence in recent years as a solid-state cooling technology due to lack of moving parts, low power consumption, silent operation and superior thermal performance over passive cooling techniques. A common embodiment of such a cooling arrangement involves needles and finned heat sink acting as emitter and collector electrodes respectively to generate ionic wind. One of the major factors that affect the reliability of these air movers is the degradation of the needles over time. In this research, we have experimentally investigated the reliability of stainless-steel needles and characterized its performance over 60 cycles of operation. The results show considerable reduction in heat transfer as evidenced from the increase heat source temperature or thermal resistance. The cooling enhancement due to DC ionic wind dropped from a factor of 2.6 to 2.05. The surface of the needles was examined under a microscope and found to undergo oxidation, wear out and micro pitting when subjected to such repeated operations under high voltage. The degradation in thermal performance could be correlated to the change in the surface finish of the needles. The results point to the importance of ensuring reliability of DC ionic winds produced under Corona discharge for cooling of electronic devices.

  • Open Access

    On Professor Roop Mahajan's 80th Birthday

    by Anandaroop Bhattacharya, Gurpreet Singh