AMAyan Majumder

Ayan Majumder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ayan Majumder has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Exploring Nanoscale Thermal Transport with Microcalorimetric Tools

    by Yuxuan Luan, Ayan Majumder, Jian Guan, Kanishka Panda, Ratul Mali, Akshay Manoj Bhaskaran, Paiting Liu, Amar Bapat, Erek Rzendzian, Evan Fleming, et al.

    Nanoscale heat transport plays an important role in energy conversion and thermal management. Therefore, understanding how nanoscale heat transport can be tuned is critical for developing novel technologies, including cooling strategies for microelectronics and nanostructured materials and devices for high-efficiency energy conversion. To probe nanoscale thermal transport phenomena, many calorimetric tools and approaches have been developed. Specifically, suspended microcalorimeters featuring picowatt resolution have been extensively employed for measuring thermal transport in low-dimensional materials, radiative heat transfer in nanoscale gaps, and between subwavelength structures. Further, scanning calorimetric probes, combined with atomic force microscopy and scanning tunneling microscopy, have been utilized for probing atomic-scale thermal transport and near-field thermal radiation. Here, we discuss these advances in calorimetric tools and their use for studying nanoscale thermal transport. We conclude by discussing open experimental challenges and highlighting the importance of future developments in subpicowatt resolution calorimetric tools for accessing unexplored nanoscale thermal transport phenomena.

  • A cryogenic near-field thermal diode leveraging superconducting phase transitions

    by Yuxuan Luan, Shen Yan, Jian Guan, Ayan Majumder, Yuji Isshiki, Zhongyong Wang, Ratul Mali, Renwen Yu, Shanhui Fan, Edgar Meyhofer, et al.

    Control of charge and heat transport is essential for computing and thermal management technologies. Recent work with superconducting materials has shown rectified electrical supercurrents near liquid helium temperatures. However, despite large theoretical interest and expected impact on quantum technologies, no experiments have demonstrated control of nanoscale radiative heat currents at cryogenic temperatures. Here we study photon-mediated thermal transport in nanogaps between niobium and gold. Using novel scanning calorimetric probes and nanofabricated devices, we reveal a ~20-fold suppression of radiative heat transport, when niobium transitions from the metallic to the superconducting state. Taking advantage of this effect, we also demonstrate a niobium-based cryogenic thermal diode with a heat rectification ratio of 70%. The experimental techniques and advances presented here will enable studying nanoscale thermal transport in quantum materials and advancing thermal management of superconducting devices.


  • Attenuating Super-Planckian Radiative Heat Transfer in Nanoscale Structures

    by Ayan Majumder, Kanishka Panda, Rohith Mittapally, Pramod Reddy, Edgar Meyhofer

    Radiative heat transfer between nanoscale (i.e., subwavelength) structures, with dimensions smaller than the thermal wavelength, can significantly surpass the far-field blackbody limit (Thompson, D.; et al. Nature 2018). This enhanced thermal coupling, called super-Planckian radiative heat transfer, limits the performance of high-resolution calorimeters [often made of silicon nitride (SiN)] used in nanoscale thermal sensing. Here, via computational and experimental work, we show that super-Planckian coupling can be significantly attenuated by employing polymers. Our calculations show that Parylene-C (a polymer) exhibits a lower density of guided-modes and reduced absorption across the thermal spectrum, suppressing this coupling by up to 10-fold compared to SiN. Experiments performed with custom-fabricated Parylene-C and SiN devices confirm that the radiative coupling is indeed attenuated in Parylene-C. Our findings highlight how the super-Planckian coupling can be attenuated for improved performance in high-resolution calorimetry.


  • Open Access

    Anisotropic Thermal Conductivity in Imine-Linked Two-Dimensional Polymer Films Produced by Interfacial Polymerization

    by Yuxing Liang, Kiana A. Treaster, Ayan Majumder, Manoj Settipalli, Kanishka Panda, Shravan Godse, Rupam Roy, Ratul Mali, Zhongyong Wang, Yuxuan Luan, et al.

    Anisotropic thermal transport was measured in imine-linked two-dimensional polymer (2DP) films that were prepared by interfacial polymerization. Measurements of both in-plane (k∥) and cross-plane (k⊥) thermal conductivities relied on preparing free-standing 2DP films that were readily transferred for different measurement configurations. We polymerized two 2DP (Per-PDA and TAPPy-PDA) films at a liquid-liquid interface. These polycrystalline, imine-linked 2DP films are 100-200 nm in thickness and were measured by frequency domain thermoreflectance to extract k⊥ and a suspended calorimetric platform technique to evaluate k∥. We find that k∥ is larger than k⊥ in both materials at room temperature, leading to anisotropy ratios (k∥/k⊥) as high as 2.3. We attribute this behavior to the fact that the stiff, in-plane covalent bonds of 2DPs transport heat more effectively than the flexible, supramolecular cross-plane interactions. Variable-temperature measurements revealed a positive correlation between temperature and thermal conductivity, which we attribute to phonon scattering from grain boundaries and defects in the polycrystalline 2DP films. Molecular dynamics simulations of pristine crystals predict larger thermal conductivities and anisotropy ratios exceeding 7. The simulations suggest that as higher quality 2DP films become available, higher thermal conductivities and anisotropy ratios will also manifest.


  • Open Access

    A nanoscale photonic thermal transistor for sub-second heat flow switching

    by Ju Won Lim, Ayan Majumder, Rohith Mittapally, Audrey-Rose Gutierrez, Yuxuan Luan, Edgar Meyhofer, Pramod Reddy

    Control of heat flow is critical for thermal logic devices and thermal management and has been explored theoretically. However, experimental progress on active control of heat flow has been limited. Here, we describe a nanoscale radiative thermal transistor that comprises of a hot source and a cold drain (both are ~250 nm-thick silicon nitride membranes), which are analogous to the source and drain electrodes of a transistor. The source and drain are in close proximity to a vanadium oxide (VOx)-based planar gate electrode, whose dielectric properties can be adjusted by changing its temperature. We demonstrate that when the gate is located close ( < ~1 µm) to the source-drain device and undergoes a metal-insulator transition, the radiative heat transfer between the source and drain can be changed by a factor of three. More importantly, our nanomembrane-based thermal transistor features fast switching times ( ~ 500 ms as opposed to minutes for past three-terminal thermal transistors) due to its small thermal mass. Our experiments are supported by detailed calculations that highlight the mechanism of thermal modulation. We anticipate that the advances reported here will open new opportunities for designing thermal circuits or thermal logic devices for advanced thermal management.


  • The Metal–Insulator Transition in Vanadium Oxide Nanofilms Enables Microkelvin-Resolution Thermometry

    by Yuxuan Luan, Shen Yan, Kanishka Panda, Ayan Majumder, Jian Guan, Rohith Mittapally, Edgar Meyhofer, Pramod Reddy

    High-resolution thermometry is critical for probing nanoscale energy transport. Here, we demonstrate how high-resolution thermometry can be accomplished using vanadium oxide (VOx), which features a sizable temperature-dependence of its resistance at room temperature and an even stronger dependence at its metal-insulator-transition (MIT) temperature. We microfabricate VOx nanofilm-based electrical resistance thermometers that undergo a metal-insulator-transition at ∼337 K and systematically quantify their temperature-dependent resistance, noise characteristics, and temperature resolution. We show that VOx sensors can achieve, in a bandwidth of ∼16 mHz, a temperature resolution of ∼5 μK at room temperature (∼300 K) and a temperature resolution of ∼1 μK at the MIT (∼337 K) when the amplitude of temperature perturbations is in the microkelvin range, which, in contrast to larger perturbations, is found to avoid hysteric resistance responses. These results demonstrate that VOx-based thermometers offer a ∼10-50-fold improvement in resolution over widely used Pt-based thermometers.


  • Open Access

    Publisher's Note: “New insights into reservoir on chip: Numerical investigation and experimental validation” [Phys. Fluids 35, 113329 (2023)]

    by Ankit Chourasia, Ayan Majumder, Sushanta K. Mitra, Anandaroop Bhattacharya

    This article was published online on 27 November 2023 with an error in Eq. (15) and in the text below it. The equations and text appear correct below. Q A c = (

  • Numerical and Experimental Investigation of a Volumetric Resistance Blower Performance and Its Optimization for Portable Computing Device Applications

    by Amit Kumar, Ayan Majumder, Ruander Cardenas, Mark MacDonald, Anandaroop Bhattacharya

    In this paper, we present our results on a relatively new kind of blower called Volumetric Resistance Blower (VRB) for cooling of portable computing platforms like laptop computers. The VRB performance was modeled numerically and compared to traditional bladed blowers. The sources of noise, dominant in bladed blower, are absent in case of VRB, because it uses a continuous porous disk instead of discrete blades. Thus, even though at iso-rpm, VRB yielded lower flowrate, its iso-acoustic performance could be superior. Hence, further analysis was crucial to quantify the potential benefit. The acoustics experiments for bladed blower and VRB were conducted in a hemi-anechoic chamber in accordance with ECMA-74 and ECMA TR/99 standards. Iso-acoustics pressure versus volume flowrate plot for both bladed blower and VRB are compared. VRB was found to have superior performance as compared to bladed blower. The volume flowrate at open flow condition for bladed blower and VRB are comparable, but as back pressure increased the flowrate yielded by VRB kept increasing and at stagnation condition, VRB showed around 79% higher static pressure. In the second part of the work, the experimentally validated numerical model for VRB was used for numerical optimization using a design of experiments (DOE) approach and varying the geometrical parameters. Rotor distance (minimum distance from the axis of rotation of impeller to the cutwater surface) was found to be the most important parameter, and an optimum value was found. A second DOE elucidated the optimal rotor hub center location in the two-dimensional space inside the casing as when the rotor is tucked back into the casing as much as possible and when the rotor distance is above 20.15 mm. A partial P–Q curve is generated (up to 20 Pa) for optimal geometry configuration. Based on the numerical and experimental evidence, VRB is found to have the potential to replace traditional bladed design in portable computing devices. In addition, due to absence of blades, it creates lower tonal noise, giving a much more comfortable experience to the end user.


  • Open Access

    New insights into reservoir on chip: Numerical investigation and experimental validation

    by Ankit Chourasia, Ayan Majumder, Sushanta K. Mitra, Anandaroop Bhattacharya

    The present study reports a numerical investigation of oil extraction from a pore-scale perspective using water as the injection fluid. The pore network is constructed from the statistical realization of the pore space of the reservoir rock. Conceptually, the pore network model used in the study miniaturizes the porous reservoir containing oil/gas onto a microfluidic platform, capturing the actual pore-level length scale and it complex features. The validity of the numerical model is established through an experimental investigation of single-phase flow. The experimentally calculated absolute permeability based on the Darcy law shows an excellent agreement with the numerically attained value. The two-phase numerical model uses the phase field technique to track the development of the interface between the two immiscible phases, i.e., oil and water. The numerical model shows a piston-like displacement and captures interesting pore-level phenomena like snap-off and trapping. Implementing the complete network for simulation reveals the unstable nature of the flooding, which is persistent with invasion percolation. The complete network simulation reveals the discontinuous flood front with a segregated flow configuration. Two-phase experiments conducted on a polydimethylsiloxane test chip with an equivalent pore level network also showed similar flow features, thereby establishing the credibility of our two-phase simulations. The recovery factor obtained from the simulation was found to be 0.78, which is in close agreement with experimental data reported in the literature. The modified Darcy law applied to the numerical model generates relative permeability plots similar to the experimental core flooding plots reported in the literature. The numerical model presented here provides valuable insight into the oil recovery process and its implications at field scale. To the best of our knowledge, this is the first instance involving numerical analysis of the full-scale system of Reservoir on a Chip system detailing the pore-level flow dynamics.


  • Quantifying the Spatial Distribution of Radiative Heat Transfer in Subwavelength Planar Nanostructures

    by Ayan Majumder, Dakotah Thompson, Rohith Mittapally, Pramod Reddy, Edgar Meyhofer