Mei-Ching Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mei-Ching Chen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Carole J. Lee
University of Washington
1 shared publication - Da-Jeng Yao
Institute of NanoEngineering and MicroSystems, National Tsing Hua University, Hsinchu 30013, Taiwan
1 shared publication - Elena A. Erosheva
University of Washington
1 shared publication Hsu-Chao Hao
Institute of NanoEngineering and MicroSystems, National, Tsing Hua University, Hsichu, Taiwan
1 shared publication- Mark D. Lindner
Center for Scientific Review, National Institutes of Health, Bethesda, Maryland, United States of America
1 shared publication - Richard K. Nakamura
National Institute of Mental Health
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 5 June 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (23) , eaaz4868
NIH peer review: Criterion scores completely account for racial disparities in overall impact scores
Black-white disparities in preliminary peer review scores for NIH R01 grant applications are examined.
- 5 June 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (23) , eaaz4868
Top Cited PapersOpen AccessNIH peer review: Criterion scores completely account for racial disparities in overall impact scores
Black-white disparities in preliminary peer review scores for NIH R01 grant applications are examined.
- 1 January 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1092-1096
A chemical surface acoustic wave(SAW) sensor array for sensing different concentration of NH3
Surface acoustic wave (SAW) sensor is generally known as high-resolution mass-sensitive transducers. We developed a novel SAW sensing array based on 2 × 2 non-continuously working oscillators equipped with differently coated SAW sensors, respectively, which is used to analyze organic compound gases. The sensing array consisting of four two-port SAW resonator sensors with a fundamental frequency at 99.8 MHz was fabricated on LiNbO 3 substrate. Four different polymers were coated on the surface of sensing regions. The gas sensing array was put into 10L reaction chamber with temperature and humidity controllable environment. The frequency outputs from each sensor were used to compare with the frequency from a reference device for eliminating the environmental effects. The results suggest that frequency shift of the designed gas sensor array changes with different concentration of the target gas(NH 3 ).
- 1 January 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1092-1096
A chemical surface acoustic wave(SAW) sensor array for sensing different concentration of NH3
Surface acoustic wave (SAW) sensor is generally known as high-resolution mass-sensitive transducers. We developed a novel SAW sensing array based on 2 × 2 non-continuously working oscillators equipped with differently coated SAW sensors, respectively, which is used to analyze organic compound gases. The sensing array consisting of four two-port SAW resonator sensors with a fundamental frequency at 99.8 MHz was fabricated on LiNbO 3 substrate. Four different polymers were coated on the surface of sensing regions. The gas sensing array was put into 10L reaction chamber with temperature and humidity controllable environment. The frequency outputs from each sensor were used to compare with the frequency from a reference device for eliminating the environmental effects. The results suggest that frequency shift of the designed gas sensor array changes with different concentration of the target gas(NH 3 ).