Sadaf Sarafan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sadaf Sarafan has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Hung Cao
Department of Electrical Engineering and Computer Science, University of California, Irvine, CA 92697, USA
6 shared publications Tadesse Ghirmai
3 shared publications- Tadesse Ghirmai
Division of Engineering and Mathematics, University of Washington, Bothell, USA
3 shared publications Afshan Hameed
Samueli School of Engineering, UC Irvine, Irvine, CA, USA
2 shared publications- Farah Torkamani Azar
Faculty of Electrical Engineering, Shahid Beheshti University, Tehran, Iran
2 shared publications - Nastaran Mansourian
Faculty of Electrical Engineering, University of Shahid Beheshti, Tehran, Iran
2 shared publications
Latest Publications
- 8 February 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (2) , 563-573
Fetal QRS extraction from single-channel abdominal ECG using adaptive improved permutation entropy
Fetal electrocardiogram (fECG) monitoring is crucial for assessing fetal condition during pregnancy. However, current fECG extraction algorithms are not suitable for wearable devices due to their high computational cost and multi-channel signal requirement. The paper introduces a novel and efficient algorithm called Adaptive Improved Permutation Entropy (AIPE), which can extract fetal QRS from a single-channel abdominal ECG (aECG). The proposed algorithm is robust and computationally efficient, making it a reliable and effective solution for wearable devices. To evaluate the performance of the proposed algorithm, we utilized our clinical data obtained from a pilot study with 10 subjects, each recording lasting 20 min. Additionally, data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations were simulated. The proposed methodology demonstrates an average positive predictive value (\(+P\)) of 91.0227%, sensitivity (Se) of 90.4726%, and F1 score of 90.6525% from the PhysioNet 2013 Challenge bank, outperforming other methods. The results suggest that AIPE could enable continuous home-based monitoring of unborn babies, even when mothers are not engaging in any hard physical activities.- 8 February 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (2) , 563-573
Fetal QRS extraction from single-channel abdominal ECG using adaptive improved permutation entropy
Fetal electrocardiogram (fECG) monitoring is crucial for assessing fetal condition during pregnancy. However, current fECG extraction algorithms are not suitable for wearable devices due to their high computational cost and multi-channel signal requirement. The paper introduces a novel and efficient algorithm called Adaptive Improved Permutation Entropy (AIPE), which can extract fetal QRS from a single-channel abdominal ECG (aECG). The proposed algorithm is robust and computationally efficient, making it a reliable and effective solution for wearable devices. To evaluate the performance of the proposed algorithm, we utilized our clinical data obtained from a pilot study with 10 subjects, each recording lasting 20 min. Additionally, data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations were simulated. The proposed methodology demonstrates an average positive predictive value (\(+P\)) of 91.0227%, sensitivity (Se) of 90.4726%, and F1 score of 90.6525% from the PhysioNet 2013 Challenge bank, outperforming other methods. The results suggest that AIPE could enable continuous home-based monitoring of unborn babies, even when mothers are not engaging in any hard physical activities.- 13 October 2022
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 80
Novel QRS detection based on the Adaptive Improved Permutation Entropy
- 13 October 2022
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 80
Novel QRS detection based on the Adaptive Improved Permutation Entropy
- Open Access
- 4 August 2022
- Published by MDPI AG in Technologies
- Vol. 10 (4) , 91
Triple-Band Implantable Antenna Design for Biotelemetry Applications in MICS/ISM/Wi-Fi/Bluetooth Bands
Our objective is to design triple-band implantable antennas with wide bandwidths and appropriate sizes for biomedical applications. The targeted design frequencies are 400 MHz, 2.4 GHz, and the new Wi-Fi band of 5.7 GHz. Three triple-band antennas with bandwidth improvements are presented to insure all-time data connection. The proposed triple-band implantable antennas benefit from combining long-distance data transfer at lower frequency bands and a higher effective bandwidth, and high-speed communications at higher frequency bands, which will have flexibility for a variety of applications. A comprehensive explanation of the design procedure to achieve multiple-band implantable antennas is provided. Furthermore, miniaturization techniques are utilized to design antennas in compact sizes suitable for biomedical applications. In this paper, three-layer structures including skin, fat, and muscle are used for the designs, then antennas are placed in the chest, neck, head, and hand of different human voxels to compare antennas’ performance. Additionally, normal and overweight human effects on antenna performance were compared. Antennas have 2 to 6 dBi directivity for telemetry usage, and they are designed to satisfy the absorption limit for the human body to keep the Specific Absorption Rate (SAR) averaged over 1 g of tissue less than 1.6 W/kg and over 10 g of tissue less than 2 W/kg, according to IEEE standard. The antennas include fractal, meandered, and comb types with sizes of 1.4 mm × 10 mm × 10 mm, 3.04 mm × 10 mm × 17.25 mm, and 1.4 mm × 12 mm × 12 mm, respectively. The designed antenna showed an impedance bandwidth of 53 MHz to 120 MHz, 90 MHz to 320 MHz, and 300 MHz to 1200 MHz at the three bands. The meandered antenna was selected for validation of simulations, and its S parameters were measured in the equivalent liquid phantom of body tissues.
- 4 August 2022
- Published by MDPI AG in Technologies
- Vol. 10 (4) , 91
Open AccessTriple-Band Implantable Antenna Design for Biotelemetry Applications in MICS/ISM/Wi-Fi/Bluetooth Bands
Our objective is to design triple-band implantable antennas with wide bandwidths and appropriate sizes for biomedical applications. The targeted design frequencies are 400 MHz, 2.4 GHz, and the new Wi-Fi band of 5.7 GHz. Three triple-band antennas with bandwidth improvements are presented to insure all-time data connection. The proposed triple-band implantable antennas benefit from combining long-distance data transfer at lower frequency bands and a higher effective bandwidth, and high-speed communications at higher frequency bands, which will have flexibility for a variety of applications. A comprehensive explanation of the design procedure to achieve multiple-band implantable antennas is provided. Furthermore, miniaturization techniques are utilized to design antennas in compact sizes suitable for biomedical applications. In this paper, three-layer structures including skin, fat, and muscle are used for the designs, then antennas are placed in the chest, neck, head, and hand of different human voxels to compare antennas’ performance. Additionally, normal and overweight human effects on antenna performance were compared. Antennas have 2 to 6 dBi directivity for telemetry usage, and they are designed to satisfy the absorption limit for the human body to keep the Specific Absorption Rate (SAR) averaged over 1 g of tissue less than 1.6 W/kg and over 10 g of tissue less than 2 W/kg, according to IEEE standard. The antennas include fractal, meandered, and comb types with sizes of 1.4 mm × 10 mm × 10 mm, 3.04 mm × 10 mm × 17.25 mm, and 1.4 mm × 12 mm × 12 mm, respectively. The designed antenna showed an impedance bandwidth of 53 MHz to 120 MHz, 90 MHz to 320 MHz, and 300 MHz to 1200 MHz at the three bands. The meandered antenna was selected for validation of simulations, and its S parameters were measured in the equivalent liquid phantom of body tissues.
- Open Access
Fetal Electrocardiogram Extraction from the Mother’s Abdominal Signal Using the Ensemble Kalman Filter
Fetal electrocardiogram (fECG) assessment is essential throughout pregnancy to monitor the wellbeing and development of the fetus, and to possibly diagnose potential congenital heart defects. Due to the high noise incorporated in the abdominal ECG (aECG) signals, the extraction of fECG has been challenging. And it is even a lot more difficult for fECG extraction if only one channel of aECG is provided, i.e., in a compact patch device. In this paper, we propose a novel algorithm based on the Ensemble Kalman filter (EnKF) for non-invasive fECG extraction from a single-channel aECG signal. To assess the performance of the proposed algorithm, we used our own clinical data, obtained from a pilot study with 10 subjects each of 20 min recording, and data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations. The proposed methodology shows the average positive predictive value (PPV) of 97.59%, sensitivity (SE) of 96.91%, and F1-score of 97.25% from the PhysioNet 2013 Challenge bank. Our results also indicate that the proposed algorithm is reliable and effective, and it outperforms the recently proposed extended Kalman filter (EKF) based algorithm.
Open AccessFetal Electrocardiogram Extraction from the Mother’s Abdominal Signal Using the Ensemble Kalman Filter
Fetal electrocardiogram (fECG) assessment is essential throughout pregnancy to monitor the wellbeing and development of the fetus, and to possibly diagnose potential congenital heart defects. Due to the high noise incorporated in the abdominal ECG (aECG) signals, the extraction of fECG has been challenging. And it is even a lot more difficult for fECG extraction if only one channel of aECG is provided, i.e., in a compact patch device. In this paper, we propose a novel algorithm based on the Ensemble Kalman filter (EnKF) for non-invasive fECG extraction from a single-channel aECG signal. To assess the performance of the proposed algorithm, we used our own clinical data, obtained from a pilot study with 10 subjects each of 20 min recording, and data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations. The proposed methodology shows the average positive predictive value (PPV) of 97.59%, sensitivity (SE) of 96.91%, and F1-score of 97.25% from the PhysioNet 2013 Challenge bank. Our results also indicate that the proposed algorithm is reliable and effective, and it outperforms the recently proposed extended Kalman filter (EKF) based algorithm.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 7116-7119
Development of a Home-based Fetal Electrocardiogram (ECG) Monitoring System
We develop a novel wearable fetal electrocardiogram (fECG) monitoring system consisting of an abdominal patch that communicates with a smart device. The system has two main components: the fetal patch and the monitoring app. The fetal patch has electronics and recording electrodes fabricated on a hybrid flexible-rigid platform while the Android app is developed for a wide range of applications. The patch collects the abdominal ECG (aECG) signals that are sent to the smart device app via secure Bluetooth Low Energy (BLE) communication. The app software connects to a cloud server where processing and extraction algorithms are executed for real-time fECG extraction and fetal heartrate (fHR) calculation from the collected raw data. We have validated the algorithms and real-time data recordings on pregnant subjects yielding promising results. Our system has the potential to transform the currently used fetal monitoring system to an effective distanced and telematernity care.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 7116-7119
Development of a Home-based Fetal Electrocardiogram (ECG) Monitoring System
We develop a novel wearable fetal electrocardiogram (fECG) monitoring system consisting of an abdominal patch that communicates with a smart device. The system has two main components: the fetal patch and the monitoring app. The fetal patch has electronics and recording electrodes fabricated on a hybrid flexible-rigid platform while the Android app is developed for a wide range of applications. The patch collects the abdominal ECG (aECG) signals that are sent to the smart device app via secure Bluetooth Low Energy (BLE) communication. The app software connects to a cloud server where processing and extraction algorithms are executed for real-time fECG extraction and fetal heartrate (fHR) calculation from the collected raw data. We have validated the algorithms and real-time data recordings on pregnant subjects yielding promising results. Our system has the potential to transform the currently used fetal monitoring system to an effective distanced and telematernity care.
- Open Access
Fetal Electrocardiogram Extraction from the Mother’s Abdominal Signal Using the Ensemble Kalman Filter
Fetal electrocardiogram (fECG) assessment is essential throughout pregnancy to monitor the wellbeing and development of the fetus, and to possibly diagnose potential congenital heart defects. Due to the high noise incorporated in the abdominal ECG (aECG) signals, the extraction of fECG has been challenging. And it is even a lot more difficult for fECG extraction if only one channel of aECG is provided, i . e . in a compact patch device. In this paper, we propose a novel algorithm based on the Ensemble Kalman Filter (EnKF) for non-invasive fECG extraction from a single-channel aECG signal. To assess the performance of the proposed algorithm, we used our own clinical data, obtained from a pilot study with 10 subjects each of 20 min recording, and data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations. The proposed methodology shows the average positive predictive value (PPV) of 97.59%, sensitivity (SE) of 96.91%, and F1-score of 97.25% from the PhysioNet 2013 Challenge bank. Our results also indicate that the proposed algorithm is reliable and effective, and it outperforms the recently proposed Extended Kalman Filter (EKF) based algorithm.
Open AccessFetal Electrocardiogram Extraction from the Mother’s Abdominal Signal Using the Ensemble Kalman Filter
Fetal electrocardiogram (fECG) assessment is essential throughout pregnancy to monitor the wellbeing and development of the fetus, and to possibly diagnose potential congenital heart defects. Due to the high noise incorporated in the abdominal ECG (aECG) signals, the extraction of fECG has been challenging. And it is even a lot more difficult for fECG extraction if only one channel of aECG is provided, i . e . in a compact patch device. In this paper, we propose a novel algorithm based on the Ensemble Kalman Filter (EnKF) for non-invasive fECG extraction from a single-channel aECG signal. To assess the performance of the proposed algorithm, we used our own clinical data, obtained from a pilot study with 10 subjects each of 20 min recording, and data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations. The proposed methodology shows the average positive predictive value (PPV) of 97.59%, sensitivity (SE) of 96.91%, and F1-score of 97.25% from the PhysioNet 2013 Challenge bank. Our results also indicate that the proposed algorithm is reliable and effective, and it outperforms the recently proposed Extended Kalman Filter (EKF) based algorithm.
- Open Access
- 5 June 2020
- Published by MDPI AG in Technologies
- Vol. 8 (2) , 33
Investigation of Methods to Extract Fetal Electrocardiogram from the Mother’s Abdominal Signal in Practical Scenarios
Monitoring of fetal electrocardiogram (fECG) would provide useful information about fetal wellbeing as well as any abnormal development during pregnancy. Recent advances in flexible electronics and wearable technologies have enabled compact devices to acquire personal physiological signals in the home setting, including those of expectant mothers. However, the high noise level in the daily life renders long-entrenched challenges to extract fECG from the combined fetal/maternal ECG signal recorded in the abdominal area of the mother. Thus, an efficient fECG extraction scheme is a dire need. In this work, we intensively explored various extraction algorithms, including template subtraction (TS), independent component analysis (ICA), and extended Kalman filter (EKF) using the data from the PhysioNet 2013 Challenge. Furthermore, the modified data with Gaussian and motion noise added, mimicking a practical scenario, were utilized to examine the performance of algorithms. Finally, we combined different algorithms together, yielding promising results, with the best performance in the F1 score of 92.61% achieved by an algorithm combining ICA and TS. With the data modified by adding different types of noise, the combination of ICA–TS–ICA showed the highest F1 score of 85.4%. It should be noted that these combined approaches required higher computational complexity, including execution time and allocated memory compared with other methods. Owing to comprehensive examination through various evaluation metrics in different extraction algorithms, this study provides insights into the implementation and operation of state-of-the-art fetal and maternal monitoring systems in the era of mobile health.
- 5 June 2020
- Published by MDPI AG in Technologies
- Vol. 8 (2) , 33
Open AccessInvestigation of Methods to Extract Fetal Electrocardiogram from the Mother’s Abdominal Signal in Practical Scenarios
Monitoring of fetal electrocardiogram (fECG) would provide useful information about fetal wellbeing as well as any abnormal development during pregnancy. Recent advances in flexible electronics and wearable technologies have enabled compact devices to acquire personal physiological signals in the home setting, including those of expectant mothers. However, the high noise level in the daily life renders long-entrenched challenges to extract fECG from the combined fetal/maternal ECG signal recorded in the abdominal area of the mother. Thus, an efficient fECG extraction scheme is a dire need. In this work, we intensively explored various extraction algorithms, including template subtraction (TS), independent component analysis (ICA), and extended Kalman filter (EKF) using the data from the PhysioNet 2013 Challenge. Furthermore, the modified data with Gaussian and motion noise added, mimicking a practical scenario, were utilized to examine the performance of algorithms. Finally, we combined different algorithms together, yielding promising results, with the best performance in the F1 score of 92.61% achieved by an algorithm combining ICA and TS. With the data modified by adding different types of noise, the combination of ICA–TS–ICA showed the highest F1 score of 85.4%. It should be noted that these combined approaches required higher computational complexity, including execution time and allocated memory compared with other methods. Owing to comprehensive examination through various evaluation metrics in different extraction algorithms, this study provides insights into the implementation and operation of state-of-the-art fetal and maternal monitoring systems in the era of mobile health.