NMNastaran Mansourian
Nastaran Mansourian
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nastaran Mansourian has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Farah Torkamani Azar
Faculty of Electrical Engineering, Shahid Beheshti University, Tehran, Iran
2 shared publications - Hung Cao
Department of Electrical Engineering and Computer Science, University of California, Irvine, CA 92697, USA
2 shared publications - Sadaf Sarafan
Department of Electrical Engineering and Computer Science, University of California Irvine, Irvine, CA 92697, USA
2 shared publications Tadesse Ghirmai
1 shared publication- Tadesse Ghirmai
Division of Engineering and Mathematics, University of Washington, Bothell, USA
1 shared publication
Latest Publications
- 8 February 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (2) , 563-573
Fetal QRS extraction from single-channel abdominal ECG using adaptive improved permutation entropy
Fetal electrocardiogram (fECG) monitoring is crucial for assessing fetal condition during pregnancy. However, current fECG extraction algorithms are not suitable for wearable devices due to their high computational cost and multi-channel signal requirement. The paper introduces a novel and efficient algorithm called Adaptive Improved Permutation Entropy (AIPE), which can extract fetal QRS from a single-channel abdominal ECG (aECG). The proposed algorithm is robust and computationally efficient, making it a reliable and effective solution for wearable devices. To evaluate the performance of the proposed algorithm, we utilized our clinical data obtained from a pilot study with 10 subjects, each recording lasting 20 min. Additionally, data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations were simulated. The proposed methodology demonstrates an average positive predictive value (\(+P\)) of 91.0227%, sensitivity (Se) of 90.4726%, and F1 score of 90.6525% from the PhysioNet 2013 Challenge bank, outperforming other methods. The results suggest that AIPE could enable continuous home-based monitoring of unborn babies, even when mothers are not engaging in any hard physical activities.- 8 February 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (2) , 563-573
Fetal QRS extraction from single-channel abdominal ECG using adaptive improved permutation entropy
Fetal electrocardiogram (fECG) monitoring is crucial for assessing fetal condition during pregnancy. However, current fECG extraction algorithms are not suitable for wearable devices due to their high computational cost and multi-channel signal requirement. The paper introduces a novel and efficient algorithm called Adaptive Improved Permutation Entropy (AIPE), which can extract fetal QRS from a single-channel abdominal ECG (aECG). The proposed algorithm is robust and computationally efficient, making it a reliable and effective solution for wearable devices. To evaluate the performance of the proposed algorithm, we utilized our clinical data obtained from a pilot study with 10 subjects, each recording lasting 20 min. Additionally, data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations were simulated. The proposed methodology demonstrates an average positive predictive value (\(+P\)) of 91.0227%, sensitivity (Se) of 90.4726%, and F1 score of 90.6525% from the PhysioNet 2013 Challenge bank, outperforming other methods. The results suggest that AIPE could enable continuous home-based monitoring of unborn babies, even when mothers are not engaging in any hard physical activities.- 13 October 2022
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 80
Novel QRS detection based on the Adaptive Improved Permutation Entropy
- 13 October 2022
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 80
Novel QRS detection based on the Adaptive Improved Permutation Entropy