Dejan Knez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dejan Knez has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Tomaž Vrtovec
University of Ljubljana
3 shared publicationsBoštjan Likar
University of Ljubljana
2 shared publicationsFranjo Pernuš
University of Ljubljana
2 shared publicationsJanez Mohar
Valdoltra Orthopedic Hospital
2 shared publications- Boštjan Likar
Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
1 shared publication - Franjo Pernuš
Faculty of Electrical Engineering, University of Ljubljana, Ljubljana, Slovenia
1 shared publication
Latest Publications
- Open Access
- 8 June 2020
- Published by Slovenian Society for Stereology and Quantitative Image Analysis in Image Analysis and Stereology
- Vol. 39 (2) , 101-109
Computerized three-dimensional pedicle morphometry from computed tomography images of the thoracic spine
Knowledge of pedicle morphometry is valuable for a safe and reliable pedicle screw placement. In this study, we performed and evaluated computerized pedicle morphometry measurements from preoperative computed tomography (CT) images of the thoracic spine from 26 subjects. Manual measurements of the pedicle width, height and chord length were obtained for 540 thoracic pedicles in selected cross sections of orthogonal and oblique multiplanar reconstructions (MPRs). Computerized measurements of the pedicle width, height, length, chord length, transverse angulation, sagittal angulation and cross-sectional area were obtained for the same pedicles by an automated method that is based on parametric modeling of vertebral structures in three dimensions (3D). Statistical analysis revealed that manual measurements from orthogonal MPRs were significantly different (p ≤ 0.0011) when compared to those from oblique MPRs and computerized measurement in 3D, with the respective mean absolute difference (MAD) ± standard deviation (SD) of 0.77 ± 0.56 mm and 0.74 ± 0.57 mm for the pedicle width, and 1.31 ± 1.08 mm and 1.45 ± 1.10 mm for the pedicle height. No statistically significant differences (p ≥ 0.12) were observed between manual measurements from oblique MPRs and computerized measurements in 3D, with MAD ± SD of 0.44 ± 0.35 mm, 0.56 ± 0.52 mm and 1.72 ± 1.29 mm for the pedicle width, height and chord length, respectively. The advantage of computerized measurements is that they allow the extraction of additional pedicle morphometric parameters, which are important for preoperative planning of pedicle screw placement, or can be used for population and demographic studies using larger pedicle databases.
- 8 June 2020
- Published by Slovenian Society for Stereology and Quantitative Image Analysis in Image Analysis and Stereology
- Vol. 39 (2) , 101-109
Open AccessComputerized three-dimensional pedicle morphometry from computed tomography images of the thoracic spine
Knowledge of pedicle morphometry is valuable for a safe and reliable pedicle screw placement. In this study, we performed and evaluated computerized pedicle morphometry measurements from preoperative computed tomography (CT) images of the thoracic spine from 26 subjects. Manual measurements of the pedicle width, height and chord length were obtained for 540 thoracic pedicles in selected cross sections of orthogonal and oblique multiplanar reconstructions (MPRs). Computerized measurements of the pedicle width, height, length, chord length, transverse angulation, sagittal angulation and cross-sectional area were obtained for the same pedicles by an automated method that is based on parametric modeling of vertebral structures in three dimensions (3D). Statistical analysis revealed that manual measurements from orthogonal MPRs were significantly different (p ≤ 0.0011) when compared to those from oblique MPRs and computerized measurement in 3D, with the respective mean absolute difference (MAD) ± standard deviation (SD) of 0.77 ± 0.56 mm and 0.74 ± 0.57 mm for the pedicle width, and 1.31 ± 1.08 mm and 1.45 ± 1.10 mm for the pedicle height. No statistically significant differences (p ≥ 0.12) were observed between manual measurements from oblique MPRs and computerized measurements in 3D, with MAD ± SD of 0.44 ± 0.35 mm, 0.56 ± 0.52 mm and 1.72 ± 1.29 mm for the pedicle width, height and chord length, respectively. The advantage of computerized measurements is that they allow the extraction of additional pedicle morphometric parameters, which are important for preoperative planning of pedicle screw placement, or can be used for population and demographic studies using larger pedicle databases.
- Open Access
- 15 January 2017
- Published by Slovenian Medical Association in Slovenian Medical Journal
- Vol. 85 (11-12)
Določanje velikosti in vstavitvene trajektorije pedikularnih vijakov v računalniškotomografskih (CT) slikah deformacij prsne hrbtenice: primerjava ročnega in računalniško podprtega predoperacijskega načrtovanja
Background: Vertebral fixation by pedicle screw placement is the most frequently applied fixation technique in spinal surgery. In this retrospective study we present a comparison of manual and computer-assisted preoperative planning of pedicle screw placement in three-dimensional (3D) computed tomography (CT) images of deformities in the thoracic spine. Methods: Manual planning of the pedicle screw size and trajectory was performed by two orthopedic surgeons using a dedicated software for preoperative planning of surgical procedures, while computer-assisted planning was performed by automated image processing and analysis techniques through the optimization of screw fastening strength. The size (diameter and length) and trajectory (pedicle crossing point, inclination in the sagittal plane, inclination in the axial plane) were obtained for 316 pedicle screws from 3D CT images of 17 patients with thoracic spinal deformities. Results: the analysis of pedicle screw parameters, obtained by two manual and one computer-assisted planning, indicated a statistically significant difference in the screw size (p < 0.05) and trajectory (p < 0.001). Computer-assisted planning proposed wider (p < 0.05) and longer (p < 0.001) screws with a higher (p < 0.001) normalized fastening strength. Conclusions: The comparison revealed consistency between manual and computer-assisted planning of the pedicle screw size and trajectory, except for the screw inclination in the sagittal plane, as manual planning followed more the straight-forward while computer-assisted planning followed more the anatomical insertion technique. While being faster, more repeatable and more reliable than manual planning, computer-assisted planning was also linked with a higher screw fastening strength and consequently a higher screw pull-out strength.
- 15 January 2017
- Published by Slovenian Medical Association in Slovenian Medical Journal
- Vol. 85 (11-12)
Open AccessDoločanje velikosti in vstavitvene trajektorije pedikularnih vijakov v računalniškotomografskih (CT) slikah deformacij prsne hrbtenice: primerjava ročnega in računalniško podprtega predoperacijskega načrtovanja
Background: Vertebral fixation by pedicle screw placement is the most frequently applied fixation technique in spinal surgery. In this retrospective study we present a comparison of manual and computer-assisted preoperative planning of pedicle screw placement in three-dimensional (3D) computed tomography (CT) images of deformities in the thoracic spine. Methods: Manual planning of the pedicle screw size and trajectory was performed by two orthopedic surgeons using a dedicated software for preoperative planning of surgical procedures, while computer-assisted planning was performed by automated image processing and analysis techniques through the optimization of screw fastening strength. The size (diameter and length) and trajectory (pedicle crossing point, inclination in the sagittal plane, inclination in the axial plane) were obtained for 316 pedicle screws from 3D CT images of 17 patients with thoracic spinal deformities. Results: the analysis of pedicle screw parameters, obtained by two manual and one computer-assisted planning, indicated a statistically significant difference in the screw size (p < 0.05) and trajectory (p < 0.001). Computer-assisted planning proposed wider (p < 0.05) and longer (p < 0.001) screws with a higher (p < 0.001) normalized fastening strength. Conclusions: The comparison revealed consistency between manual and computer-assisted planning of the pedicle screw size and trajectory, except for the screw inclination in the sagittal plane, as manual planning followed more the straight-forward while computer-assisted planning followed more the anatomical insertion technique. While being faster, more repeatable and more reliable than manual planning, computer-assisted planning was also linked with a higher screw fastening strength and consequently a higher screw pull-out strength.
- 1 July 2016
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 3-13
Automated Pedicle Screw Size and Trajectory Planning by Maximization of Fastening Strength
- 1 July 2016
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 3-13
Automated Pedicle Screw Size and Trajectory Planning by Maximization of Fastening Strength
- 1 January 2016
- Published by Springer Nature
- p. 105-115
Manual and Computer-Assisted Pedicle Screw Placement Plans: A Quantitative Comparison
- 1 January 2016
- Published by Springer Nature
- p. 105-115
Manual and Computer-Assisted Pedicle Screw Placement Plans: A Quantitative Comparison