    Gadolinium oxide nanoparticles as a multimodal contrast enhancement agent for pre-clinical proton imaging

    by Matthias Würl, Grigory Liubchenko, Guyue Hu, Katrin Schnürle, Sebastian Meyer, Jonathan Bortfeldt, Guillaume Landry, Lukas Käsmann, Kirsten Lauber, Carlos Granja, et al.

    Orthotopic tumor models in pre-clinical translational research are becoming increasingly popular, raising the demands on accurate tumor localization prior to irradiation. This task remains challenging both in x-ray and proton computed tomography (xCT and pCT, respectively), due to the limited contrast of tumor tissue compared to the surrounding tissue. We investigate the feasibility of gadolinium oxide nanoparticles as a multimodal contrast enhancement agent for both imaging modalities. We performed proton radiographies at the experimental room of the Trento Proton Therapy Center using a MiniPIX-Timepix detector and dispersions of gadolinium oxide nanoparticles in sunflower oil with mass fractions up to 8wt%. To determine the minimum nanoparticle concentration required for the detectability of small structures, pCT images of a cylindrical water phantom with cavities of varying gadolinium oxide concentration were simulated using a dedicated FLUKA Monte Carlo framework. These findings are complemented by simulating pCT at dose levels from 80 mGy to 320 mGy of artificially modified murine xCT data, mimicking different levels of gadolinium oxide accumulation inside a fictitious tumor volume. To compare the results obtained for proton imaging to x-ray imaging, cone-beam CT images of a cylindrical PMMA phantom with cavities of dispersions of oil and gadolinium oxide nanoparticles with mass fractions up to 8wt% were acquired at a commercial pre-clinical irradiation setup. For proton radiography, considerable contrast enhancement was found for a mass fraction of 4wt%. Slightly lower values were found for the simulated pCT images at imaging doses below 200 mGy. In contrast, full detectability of small gadolinium oxide loaded structures in xCT at comparable imaging dose is already achieved for 0.5wt%. Achieving such concentrations required for pCT imaging inside a tumor volume in in-vivo experiments may be challenging, yet it might be feasible using different targeting and/or injection strategies.


  • Open Access

    On the robustness of multilateration of ionoacoustic signals for localization of the Bragg peak at pre-clinical proton beam energies in water

    by Ronaldo Kalunga, Hans-Peter Wieser, Pratik Dash, Matthias Würl, Marco Riboldi, Jörg Schreiber, Walter Assmann, Katia Parodi, Julie Lascaud

    Objectives. The energy deposited in a medium by a pulsed proton beam results in the emission of thermoacoustic waves, also called ionoacoustics (IA). The proton beam stopping position (Bragg peak) can be retrieved from a time-of-flight analysis (ToF) of IA signals acquired at different sensor locations (multilateration). This work aimed to assess the robustness of multilateration methods in proton beams at pre-clinical energies for the development of a small animal irradiator. Approach. The accuracy of multilateration performed using different algorithms; namely, time of arrival and time difference of arrival, was investigated in-silico for ideal point sources in the presence of realistic uncertainties on the ToF estimation and ionoacoustic signals generated by a 20 MeV pulsed proton beam stopped in a homogeneous water phantom. The localisation accuracy was further investigated experimentally based on two different measurements with pulsed monoenergetic proton beams at energies of 20 and 22 MeV. Main results. It was found that the localisation accuracy mainly depends on the position of the acoustic detectors relative to the proton beam due to spatial variation of the error on the ToF estimation. By optimally positioning the sensors to reduce the ToF error, the Bragg peak could be located in-silico with an accuracy better than 90 μm (2% error). Localisation errors going up to 1 mm were observed experimentally due to inaccurate knowledge of the sensor positions and noisy ionoacoustic signals. Significance. This study gives a first overview of the implementation of different multilateration methods for ionoacoustics-based Bragg peak localisation in two- and three-dimensions at pre-clinical energies. Different sources of uncertainty were investigated, and their impact on the localisation accuracy was quantified in-silico and experimentally.


  • Open Access

    Fabrication and characterization of a multimodal 3D printed mouse phantom for ionoacoustic quality assurance in image-guided pre-clinical proton radiation research

    by Julie Lascaud, Pratik Dash, Katrin Schnürle, Jonathan Bortfeldt, Katharina Niepel, Jessica Maas, Matthias Würl, Marie Vidal, Joël Hérault, Guillaume Landry, et al.

    Objective. Image guidance and precise irradiation are fundamental to ensure the reliability of small animal oncology studies. Accurate positioning of the animal and the in-beam monitoring of the delivered radio-therapeutic treatment necessitate several imaging modalities. In the particular context of proton therapy with a pulsed beam, information on the delivered dose can be retrieved by monitoring the thermoacoustic waves resulting from the brief and local energy deposition induced by a proton beam (ionoacoustics). The objective of this work was to fabricate a multimodal phantom (x-ray, proton, ultrasound, and ionoacoustics) allowing for sufficient imaging contrast for all the modalities. Approach. The phantom anatomical parts were extracted from mouse computed tomography scans and printed using polylactic acid (organs) and a granite/polylactic acid composite (skeleton). The anatomical pieces were encapsulated in silicone rubber to ensure long term stability. The phantom was imaged using x-ray cone-beam computed tomography, proton radiography, ultrasound imaging, and monitoring of a 20 MeV pulsed proton beam using ionoacoustics. Main results. The anatomical parts could be visualized in all the imaging modalities validating the phantom capability to be used for multimodal imaging. Ultrasound images were simulated from the x-ray cone-beam computed tomography and co-registered with ultrasound images obtained before the phantom irradiation and low-resolution ultrasound images of the mouse phantom in the irradiation position, co-registered with ionoacoustic measurements. The latter confirmed the irradiation of a tumor surrogate for which the reconstructed range was found to be in reasonable agreement with the expectation. Significance. This study reports on a realistic small animal phantom which can be used to investigate ionoacoustic range (or dose) verification together with ultrasound, x-ray, and proton imaging. The co-registration between ionoacoustic reconstructions of the impinging proton beam and x-ray imaging is assessed for the first time in a pre-clinical scenario.


  • Open Access

    A Monte Carlo feasibility study on quantitative laser-driven proton radiography

    by Matthias Würl, Chiara Gianoli, Franz Siegfried Englbrecht, Jörg Schreiber, Katia Parodi


  • Open Access

    Experimental demonstration of accurate Bragg peak localization with ionoacoustic tandem phase detection (iTPD)

    by H P Wieser, Y Huang, J Schauer, J Lascaud, M Würl, S Lehrack, D Radonic, M Vidal, J Hérault, A Chmyrov, et al.

    Accurate knowledge of the exact stopping location of ions inside the patient would allow full exploitation of their ballistic properties for patient treatment. The localized energy deposition of a pulsed particle beam induces a rapid temperature increase of the irradiated volume and leads to the emission of ionoacoustic (IA) waves. Detecting the time-of-flight (ToF) of the IA wave allows inferring information on the Bragg peak location and can henceforth be used for in-vivo range verification. A challenge for IA is the poor signal-to-noise ratio at clinically relevant doses and viable machines. We present a frequency-based measurement technique, labeled as ionoacoustic tandem phase detection (iTPD) utilizing lock-in amplifiers. The phase shift of the IA signal to a reference signal is measured to derive the ToF. Experimental IA measurements with a 3.5 MHz lead zirconate titanate (PZT) transducer and lock-in amplifiers were performed in water using 22 MeV proton bursts. A digital iTPD was performed in-silico at clinical dose levels on experimental data obtained from a clinical facility and secondly, on simulations emulating a heterogeneous geometry. For the experimental setup using 22 MeV protons, a localization accuracy and precision obtained through iTPD deviates from a time-based reference analysis by less than 15 μm. Several methodological aspects were investigated experimentally in systematic manner. Lastly, iTPD was evaluated in-silico for clinical beam energies indicating that iTPD is in reach of sub-mm accuracy for fractionated doses < 5 Gy. iTPD can be used to accurately measure the ToF of IA signals online via its phase shift in frequency domain. An application of iTPD to the clinical scenario using a single pulsed beam is feasible but requires further development to reach <1 Gy detection capabilities.


  • Open Access

    Investigating the accuracy of co-registered ionoacoustic and ultrasound images in pulsed proton beams

    by Julie Lascaud, Pratik Dash, Hans-Peter Wieser, Ronaldo Kalunga, Matthias Würl, Walter Assmann, Katia Parodi

    The sharp spatial and temporal dose gradients of pulsed ion beams result in an acoustic emission (ionoacoustics), which can be used to reconstruct the dose distribution from measurements at different positions. The accuracy of range verification from ionoacoustic images measured with an ultrasound linear array configuration is investigated both theoretically and experimentally for monoenergetic proton beams at energies relevant for pre-clinical studies (20 and 22 MeV). The influence of the linear sensor array arrangement (length up to 4 cm and number of elements from 5 to 200) and medium properties on the range estimation accuracy are assessed using time-reversal reconstruction. We show that for an ideal homogeneous case, the ionoacoustic images enable a range verification with a relative error lower than 0.1%, however, with limited lateral dose accuracy. Similar results were obtained experimentally by irradiating a water phantom and taking into account the spatial impulse response (geometry) of the acoustic detector during the reconstruction of pressures obtained by moving laterally a single-element transducer to mimic a linear array configuration. Finally, co-registered ionoacoustic and ultrasound images were investigated using silicone inserts immersed in the water phantom across the proton beam axis. By accounting for the sensor response and speed of sound variations (deduced from co-registration with ultrasound images) the accuracy is improved to a few tens of micrometers (relative error less than to 0.5%), confirming the promise of ongoing developments for ionoacoustic range verification in pre-clinical and clinical proton therapy applications.


  • Open Access

    A feasibility study of zebrafish embryo irradiation with laser-accelerated protons

    by Thomas F. Rösch, Zoltán Szabó, Daniel Haffa, Jianhui Bin, Szilvia Brunner, Franz S. Englbrecht, Anna A. Friedl, Ying Gao, Jens Hartmann, Peter Hilz, et al.

    The development from single shot basic laser plasma interaction research toward experiments in which repetition rated laser-driven ion sources can be applied requires technological improvements. For example, in the case of radio-biological experiments, irradiation duration and reproducible controlled conditions are important for performing studies with a large number of samples. We present important technological advancements of recent years at the ATLAS 300 laser in Garching near Munich since our last radiation biology experiment. Improvements range from target positioning over proton transport and diagnostics to specimen handling. Exemplarily, we show the current capabilities by performing an application oriented experiment employing the zebrafish embryo model as a living vertebrate organism for laser-driven proton irradiation. The size, intensity, and energy of the laser-driven proton bunches resulted in evaluable partial body changes in the small (in vivo biological experiments, in particular the need for accurate, spatially resolved single bunch dosimetry and image guidance.


  • Open Access

    Experimental studies with two novel silicon detectors for the development of time-of-flight spectrometry of laser-accelerated proton beams

    by M Würl, S Reinhardt, A Rosenfeld, M Petasecca, M Lerch, L Tran, S Karsch, W Assmann, J Schreiber, K Parodi

    Laser-accelerated proton beams exhibit remarkably different beam characteristics as compared to conventionally accelerated ion beams. About 105 to 107 particles per MeV and msr are accelerated quasi-instantaneously within about 1 ps. The resulting energy spectrum typically shows an exponentially decaying distribution. Our planned approach to determine the energy spectrum of the particles generated in each pulse is to exploit the time-of-flight (TOF) difference of protons with different kinetic energies at 1 m distance from the laser-target interaction. This requires fast and sensitive detectors. We therefore tested two prototype silicon detectors, developed at the Centre for Medical Radiation Physics at the University of Wollongong with a current amplifier, regarding their suitability for TOF-spectrometry in terms of sensitivity and timing properties. For the latter, we illuminated the detectors with short laser pulses, measured the signal current and compared it to the signal of a fast photodiode. The comparison revealed that the timing properties of both prototypes are not yet sufficient for our purpose. In contrast, our results regarding the detectors' sensitivity are promising. The lowest detectable proton flux at 10 MeV was found to be 25 protons per ns on the detector. With this sensitivity and with a smaller pixelation of the detectors, the timing properties can be improved for new prototypes, making them potential candidates for TOF-spectrometry of laser-accelerated particle beams.

  • Dosimetric impact of the low-dose envelope of scanned proton beams at a ProBeam facility: comparison of measurements with TPS and MC calculations

    by M Würl, F Englbrecht, K Parodi, M Hillbrand

    Due to the low-dose envelope of scanned proton beams, the dose output depends on the size of the irradiated field or volume. While this field size dependence has already been extensively investigated by measurements and Monte Carlo (MC) simulations for single pencil beams or monoenergetic fields, reports on the relevance of this effect for analytical dose calculation models are limited. Previous studies on this topic only exist for specific beamline designs. However, the amount of large-angle scattered primary and long-range secondary particles and thus the relevance of the low-dose envelope can considerably be influenced by the particular design of the treatment nozzle. In this work, we therefore addressed the field size dependence of the dose output at the commercially available ProBeam® beamline, which is being built in several facilities worldwide. We compared treatment planning dose calculations with ionization chamber (IC) measurements and MC simulations, using an experimentally validated FLUKA MC model of the scanning beamline. To this aim, monoenergetic square fields of three energies, as well as spherical target volumes were studied, including the investigation on the influence of the lateral spot spacing on the field size dependence. For the spherical target volumes, MC as well as analytical dose calculation were found in excellent agreement with the measurements in the center of the spread-out Bragg peak. In the plateau region, the treatment planning system (TPS) tended to overestimate the dose compared to MC calculations and IC measurements by up to almost 5% for the smallest investigated sphere and for small monoenergetic square fields. Narrower spot spacing slightly enhanced the field size dependence of the dose output. The deviations in the plateau dose were found to go in the clinically safe direction, i.e. the actual deposited dose outside the target was found to be lower than predicted by the TPS. Thus, the moderate overestimation of dose to normal tissue by the TPS is likely to result in no severe consequences in clinical cases, even for the most critical cases of small target volumes.


  • Open Access

    Red Supergiant Stars as Cosmic Abundance Probes: II. NLTE Effects in J-band Silicon Lines

    by Maria Bergemann, Rolf-Peter Kudritzki, Matthias Wueurl, Bertrand Plez, Ben Davies, Zach Gazak

    Medium resolution J-band spectroscopy of individual red supergiant stars is a promising tool to investigate the chemical composition of the young stellar population in star forming galaxies. As a continuation of recent work on iron and titanium, detailed non-LTE calculations are presented to investigate the influence of NLTE on the formation of silicon lines in the J-band spectra of red supergiants. Substantial effects are found resulting in significantly stronger absorption lines of neutral silicon in non-LTE. As a consequence, silicon abundances determined in non-LTE are significantly smaller than in LTE with the non-LTE abundance corrections varying smoothly between -0.4 dex to -0.1 dex for effective temperatures between 3400K to 4400K. The effects are largest at low metallicity. The physical reasons behind the non-LTE effects and the consequences for extragalactic J-band abundance studies are discussed.