Byoung Chul Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Byoung Chul Kim has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Young Han Kim
Dept. of Industrial Chemistry, Pukyong National University, Busan, Korea
4 shared publications - Yong Kweon Suh
Department of Mechanical Engineering, Dong-A University, 840 Hadan-dong, Saha-gu, Busan 604-714, Republic of Korea
2 shared publications Hyun Woog Kang
Department of Chemical Engineering, Dong-A University, Pusan 604-714, Korea
1 shared publication- Takuji Yamamoto
Department of Chemical Engineering and Materials Science, Graduate School of Engineering, University of Hyogo, Himeji, Japan
1 shared publication - Young Gun Heo
Department of Mechanical Engineering, Dong-A University, 840 Hadan-dong, Saha-gu, Pusan, 604-714 Korea
1 shared publication
Latest Publications
- Open Access
In-Line Measurement of Water Content in Ethanol Using a PVA-Coated Quartz Crystal Microbalance
An in-line device for measuring the water content in ethanol was developed using a polyvinyl alcohol (PVA)-coated quartz crystal microbalance. Bio-ethanol is widely used as the replacement of gasoline, and its water content is a key component of its specifications. When the PVA-coated quartz crystal microbalance is contacted with ethanol containing a small amount of water, the water is absorbed into the PVA increasing the load on the microbalance surface to cause a frequency drop. The determination performance of the PVA-coated microbalance is examined by measuring the frequency decreases in ethanol containing 2% to 10% water while the ethanol flows through the measurement device. The measurements indicates that the higher water content is the more the frequency reduction is, though some deviation in the measurements is observed. This indicates that the frequency measurement of an unknown concentration of water in ethanol can be used to determine the water content in ethanol. The PVA coating is examined by microscopy and FTIR (Fourier transform infrared) spectroscopy.
Open AccessIn-Line Measurement of Water Content in Ethanol Using a PVA-Coated Quartz Crystal Microbalance
An in-line device for measuring the water content in ethanol was developed using a polyvinyl alcohol (PVA)-coated quartz crystal microbalance. Bio-ethanol is widely used as the replacement of gasoline, and its water content is a key component of its specifications. When the PVA-coated quartz crystal microbalance is contacted with ethanol containing a small amount of water, the water is absorbed into the PVA increasing the load on the microbalance surface to cause a frequency drop. The determination performance of the PVA-coated microbalance is examined by measuring the frequency decreases in ethanol containing 2% to 10% water while the ethanol flows through the measurement device. The measurements indicates that the higher water content is the more the frequency reduction is, though some deviation in the measurements is observed. This indicates that the frequency measurement of an unknown concentration of water in ethanol can be used to determine the water content in ethanol. The PVA coating is examined by microscopy and FTIR (Fourier transform infrared) spectroscopy.
- Open Access
Determination of Viscoelastic Property in Polyethylene Crystallization Using a Quartz Crystal Resonator
A new generalized relationship between the viscoelastic properties of an overlayer placed on the electrode interface of a quartz crystal resonator and its resonant characteristic is developed from the mechanics of the quartz movement. The relationship is used to estimate the viscoelastic properties from the experimentally measured resonant characteristic. It is utilized in the estimation of viscosity and elastic shear modulus of a polyethylene overlayer during its crystallization. The measurements are compared with the viscosity and elastic shear modulus of a polyethylene melt measured using a rheometer. It is found that the development of this study is useful in the determination of viscoelastic property of polymer materials by measuring the resonant frequency and conductance of the polymer overlayer placed on the resonator electrode.
Open AccessDetermination of Viscoelastic Property in Polyethylene Crystallization Using a Quartz Crystal Resonator
A new generalized relationship between the viscoelastic properties of an overlayer placed on the electrode interface of a quartz crystal resonator and its resonant characteristic is developed from the mechanics of the quartz movement. The relationship is used to estimate the viscoelastic properties from the experimentally measured resonant characteristic. It is utilized in the estimation of viscosity and elastic shear modulus of a polyethylene overlayer during its crystallization. The measurements are compared with the viscosity and elastic shear modulus of a polyethylene melt measured using a rheometer. It is found that the development of this study is useful in the determination of viscoelastic property of polymer materials by measuring the resonant frequency and conductance of the polymer overlayer placed on the resonator electrode.
- Open Access
Detection of Simulated Defect Using IR Temperature Sensors and One Point Heating
Infrared temperature sensors, simple device for temperature measurement, have been modified for the measurement of temperature distribution on the metal surface in a way of nondestructive detection of defects of the object. In this study, the IR sensor system is utilized for the defect detection in a cylinder with one point heating, and the performance of the system is examined with an aluminum cylinder having a simulated defect. In addition, a 3-D conduction equation is numerically solved to compare the computed temperature profile with the measured one. The experimental outcome indicates that the defect detection is readily available with the proposed device and the point heating is practical for the applications of the defect detection. It is also found that the measured temperature distribution is comparable to the computed result from the conduction equation.
Open AccessDetection of Simulated Defect Using IR Temperature Sensors and One Point Heating
Infrared temperature sensors, simple device for temperature measurement, have been modified for the measurement of temperature distribution on the metal surface in a way of nondestructive detection of defects of the object. In this study, the IR sensor system is utilized for the defect detection in a cylinder with one point heating, and the performance of the system is examined with an aluminum cylinder having a simulated defect. In addition, a 3-D conduction equation is numerically solved to compare the computed temperature profile with the measured one. The experimental outcome indicates that the defect detection is readily available with the proposed device and the point heating is practical for the applications of the defect detection. It is also found that the measured temperature distribution is comparable to the computed result from the conduction equation.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4684-4687
Measurement of Algae Population for Red-Tide Prediction
The most important effects on algae multiplication are coming from maintaining the growth environment such as necessary nutrients and proper temperature, but it is difficult to adjust for every species individually. In this study, therefore, the environment is obtained using the local water where target organisms live, and their growth is promoted by raising the water temperature. A sensor to count the organism population is developed here. Because the early stage of a sudden increase of the algae population is detected using the sensor, it is available to predict the sudden increase of algae, a source of red tide
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4684-4687
Measurement of Algae Population for Red-Tide Prediction
The most important effects on algae multiplication are coming from maintaining the growth environment such as necessary nutrients and proper temperature, but it is difficult to adjust for every species individually. In this study, therefore, the environment is obtained using the local water where target organisms live, and their growth is promoted by raising the water temperature. A sensor to count the organism population is developed here. Because the early stage of a sudden increase of the algae population is detected using the sensor, it is available to predict the sudden increase of algae, a source of red tide