Young Gun Heo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Young Gun Heo has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Byoung Chul Kim
Department of Chemical Engineering, Dong-A University, Pusan 604-714, Korea
1 shared publication - Yong Kweon Suh
Department of Mechanical Engineering, Dong-A University, 840 Hadan-dong, Saha-gu, Busan 604-714, Republic of Korea
1 shared publication - Young Han Kim
Dept. of Industrial Chemistry, Pukyong National University, Busan, Korea
1 shared publication
Latest Publications
- Open Access
Detection of Simulated Defect Using IR Temperature Sensors and One Point Heating
Infrared temperature sensors, simple device for temperature measurement, have been modified for the measurement of temperature distribution on the metal surface in a way of nondestructive detection of defects of the object. In this study, the IR sensor system is utilized for the defect detection in a cylinder with one point heating, and the performance of the system is examined with an aluminum cylinder having a simulated defect. In addition, a 3-D conduction equation is numerically solved to compare the computed temperature profile with the measured one. The experimental outcome indicates that the defect detection is readily available with the proposed device and the point heating is practical for the applications of the defect detection. It is also found that the measured temperature distribution is comparable to the computed result from the conduction equation.
Open AccessDetection of Simulated Defect Using IR Temperature Sensors and One Point Heating
Infrared temperature sensors, simple device for temperature measurement, have been modified for the measurement of temperature distribution on the metal surface in a way of nondestructive detection of defects of the object. In this study, the IR sensor system is utilized for the defect detection in a cylinder with one point heating, and the performance of the system is examined with an aluminum cylinder having a simulated defect. In addition, a 3-D conduction equation is numerically solved to compare the computed temperature profile with the measured one. The experimental outcome indicates that the defect detection is readily available with the proposed device and the point heating is practical for the applications of the defect detection. It is also found that the measured temperature distribution is comparable to the computed result from the conduction equation.