Renata P. A. Balvedi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Renata P. A. Balvedi has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ana Graci Brito Madurro
Institute of Biotechnology, Federal University of Uberlândia, Uberlândia, Brazil
2 shared publications - Ana C. H. Castro
Institute of Genetics and Biochemistry, Federal University of Uberlândia, Uberlândia 38400-902, Brazil
1 shared publication J.M. Madurro
Federal University of Uberlândia, Institute of Chemistry, Av. João Naves de Ávila 2121, Uberlândia, MG, Brasil
1 shared publication- João Marcos Madurro
Institute of Chemistry, Federal University of Uberlândia, Uberlândia, Brazil
1 shared publication L.P. Caetano
Federal University of Uberlândia, Institute of Genetics and Biochemistry, Av. Pará 1729, Uberlândia, MG, Brasil
1 shared publication
Latest Publications
- 1 November 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 85, 226-231
Use of 3,3',5,5' tetramethylbenzidine as new electrochemical indicator of DNA hybridization and its application in genossensor
- 1 November 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 85, 226-231
Use of 3,3',5,5' tetramethylbenzidine as new electrochemical indicator of DNA hybridization and its application in genossensor
- Open Access
- 21 May 2014
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 15 (5) , 9051-9066
Detection of a Specific Biomarker for Epstein-Barr Virus Using a Polymer-Based Genosensor
This paper describes methodology for direct and indirect detections of a specific oligonucleotide for Epstein-Barr virus (EBV) using electrochemical techniques. The sequence of oligonucleotide probe (EBV1) revealed a high sequence identity (100%) with the EBV genome. For the development of the genosensor, EBV1 was grafted to the platform sensitized with poly(4-aminothiophenol). After that, the hybridization reaction was carried out with the complementary target (EBV2) on the modified electrode surface using ethidium bromide as DNA intercalator. The oxidation peak currents of ethidium bromide increased linearly with the values of the concentration of the complementary sequences in the range from 3.78 to 756 µmol·L−1. In nonstringent experimental conditions, this genosensor can detect 17.32 nmol·L−1 (three independent experiments) of oligonucleotide target, discriminating between complementary and non-complementary oligonucleotides, as well as differentiating one-base mismatch, as required for detection of genetic diseases caused by point mutations. The biosensor also displayed high specificity to the EBV target with elimination of interference from mix (alanine, glucose, uric acid, ascorbic acid, bovine serum albumin (BSA), glutamate and glycine) and good stability (120 days). In addition, it was possible to observe differences between hybridized and non-hybridized surfaces through atomic force microscopy.
- 21 May 2014
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 15 (5) , 9051-9066
Open AccessDetection of a Specific Biomarker for Epstein-Barr Virus Using a Polymer-Based Genosensor
This paper describes methodology for direct and indirect detections of a specific oligonucleotide for Epstein-Barr virus (EBV) using electrochemical techniques. The sequence of oligonucleotide probe (EBV1) revealed a high sequence identity (100%) with the EBV genome. For the development of the genosensor, EBV1 was grafted to the platform sensitized with poly(4-aminothiophenol). After that, the hybridization reaction was carried out with the complementary target (EBV2) on the modified electrode surface using ethidium bromide as DNA intercalator. The oxidation peak currents of ethidium bromide increased linearly with the values of the concentration of the complementary sequences in the range from 3.78 to 756 µmol·L−1. In nonstringent experimental conditions, this genosensor can detect 17.32 nmol·L−1 (three independent experiments) of oligonucleotide target, discriminating between complementary and non-complementary oligonucleotides, as well as differentiating one-base mismatch, as required for detection of genetic diseases caused by point mutations. The biosensor also displayed high specificity to the EBV target with elimination of interference from mix (alanine, glucose, uric acid, ascorbic acid, bovine serum albumin (BSA), glutamate and glycine) and good stability (120 days). In addition, it was possible to observe differences between hybridized and non-hybridized surfaces through atomic force microscopy.