YWYanju Wu

Yanju Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yanju Wu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    C-undecylcalix[4]resorcinarene Langmuir–Blodgett/Porous Reduced Graphene Oxide Composite Film as a Electrochemical Sensor for the Determination of Tryptophan

    by Yanju Wu, Keyu Chen, Fei Wang

    In this study, a composite film was developed for the electrochemical sensing of tryptophan (Trp). Porous reduced graphene oxide (PrGO) was utilized as the electron transfer layer, and a C-undecylcalix[4]resorcinarene Langmuir–Blodgett (CUCR-LB) film served as the molecular recognition layer. Atomic force microscopy (AFM), transmission electron microscopy (TEM), Raman spectroscopy, scanning electron microscopy (SEM), and electrochemical experiments were employed to analyze the characteristics of the CUCR-LB/PrGO composite film. The electrochemical behavior of Trp on the CUCR-LB/PrGO composite film was investigated, revealing a Trp linear response range of 1.0 × 10−7 to 3.0 × 10−5 mol L−1 and a detection limit of 3.0 × 10−8 mol L−1. Furthermore, the developed electroanalytical method successfully determined Trp content in an amino acid injection sample. This study not only introduces a rapid and reliable electrochemical method for the determination of Trp but also presents a new strategy for constructing high-performance electrochemical sensing platforms.


  • Open Access

    C-undecylcalix[4]resorcinarene Langmuir-Blodgett/Porous Reduced Graphene Oxide Composite Film as a Electrochemical Sensor for Determination of Tryptophan

    by Yanju Wu, Keyu Chen, Song Li, Junlong Ma, Baoshan Wang, Fei Wang

    In this study, a composite film was developed for electrochemical sensing of tryptophan (Trp). Porous reduced graphene oxide (PrGO) was utilized as the electron transfer layer, and a C-undecylcalix[4] resorcinarene Langmuir-Blodgett (CUCR-LB) film served as the molecular recognition layer. Atomic force microscopy (AFM), transmission electron microscopy (TEM), Raman spectroscopy, scanning electron microscopy (SEM), and electrochemical experiments were employed to analyze the characteristics of the CUCR-LB/PrGO composite film. The electrochemical behavior of Trp on the CUCR-LB/PrGO composite film was investigated, revealing a linear response range of Trp was 1.0×10-7 to 3.0×10-5 mol L-1 and a detection limit of 3.0×10-8 mol L-1. Furthermore, the developed electroanalytical method successfully determined Trp content in an amino acid injection samples. This study not only introduces a rapid and reliable electrochemical method for determination of Trp but also presents a new strategy for constructing high-performance electrochemical sensing platforms.

  • Open Access

    3D Graphene-Nitrogen Doped Carbon Nanotubes Network Modified Electrode as Sensing Materials for the Determination of Urapidil

    by Yanju Wu, Anxing Zhou, Huimin Yang, Fei Wang, Kui Lu

    In this work, a three dimensional (3D) graphene-nitrogen doped carbon nanotubes (G-NCNTs) network was successfully fabricated on the surface of a glassy carbon (GC) electrode using the pulse potential method (PPM) in a graphene oxide-nitrogen doped carbon nanotubes (GO-NCNTs) dispersion. The morphological and characteristics of GO-NCNTs and G-NCNTs nanocomposites were investigated by atomic force microscopy (AFM), scanning electron microscopy (SEM), UV-vis spectroscopy, Raman spectroscopy, and electrochemical experiments. The 3DG-NCNTs network was applied as a new voltammetric material for the fabrication of an electrochemical platform for determination of urapidil. Systematic electrochemical tests demonstrate that the 3DG-NCNTs network modified GC electrode can effectively increase the response to the oxidation of urapidil. Under the optimum conditions, the electrochemical response was linear with urapidil concentrations in the range of 1.0 × 10−8~2.0 × 10−6 mol·L−1, while a low detection limit of 5.0 × 10−9 mol·L−1 was obtained for urapidil. Moreover, the proposed sensing platform exhibited good results for sensitivity, reproducibility, selectivity, and stability, which makes it very suitable for use as an ideal inexpensive and rapid analytical method applicable for complex drug matrices.